Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹37.1 L+₹13.9 L (60.0%)Rejected-AOC PLOT NO 52 BAKSHI NAGAR JAMMU 180001 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L2 | Rejected-AOC other than lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE Rajouri PIN-900129 C/o 56 APO
REPAIR TO HT OH LINES, UG CABLES, TRANSFORMERS AND OTHER CONNECTED WORKS AT NORTH AND SOUTH ZONE OF NAUSHERA UNDER GE 862 EWS
2022_MES_544598_1
CANO-CWE/RAJ-40/2022-23
Open Tender
Support/Maintenance Service
Item Rate
180 days
Naushera AoR of GE 862 EWS
Class D Category b(ii)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹80,000
Yes
4 Nov 2022
11 Aug 2022
15 Sept 2022
11 Aug 2022
8 Sept 2022
25 Aug 2022
Amount
Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of GI earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and as directed.
Dismantling of old, unserviceable HT (PCC) concrete pole of any size with necessary demolition of concrete foundation including excavation, earth work as reqd complete all as specified and as directed.
Takig down old unserviceable HT cable any size from any position complete all as specified and directed.
HT XLPE insulated , screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade cross sectional area 95 Sq mm 3 core complete all as specified and directed.
HT XLPE insulated , screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade cross sectional area 120 Sq mm 3 core, complete all as specified and directed.
HT XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade cross sectional area 185 Sq mm 3 core complete all as specified and directed.
Taking down old unserviceable HT GOD any type and size complete all as specified and directed.
Air break isolator triple pole mechanically operated from gound mounted on insulators and steel frame including all fixing arrangement on HT pole, connection with ACSR, aluminium lugs, meggering & testing, dismantling of old unserviceable isolator for current rating upto 400 amp 11000 Volts all as specified and directed.
Taking down old unserviceable GI pipe any size / type complete all as specified and directed.
GI pipe light grade 80 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps of required size, nuts, bolts, washers etc. fixed, complete all as specified.
Excavation in trenches n. exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in any type of soil complete all as specified and as directed.
All as per item No. 12 above, but for each additional 1.5 mtr or part there of in depth beyond the first 1.5 mtr for foundation of poles complete all as specified and as directed..
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 mtr above the starting point, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm, complete all as specified and as directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work all as specified and directed.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for foundation around poles / stays etc, including necessary form work, all as specified and directed.
PCC 1:2:4 (nominal mix) type B1 using 20mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating with & including necessory form work required, complete all as specified and directed.
Supply and erecting in replacement of truely vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide primer and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing & marking pole Nos with black paint, complete all as specified and directed. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch 'A').
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as reqd. and removing the same from site complete all as specified & as directed.
Stay assembly complete with accessories and GI stay rod 20 mm dia 1900 long, stay plate 300mm x 300mm x 6mm, galvanised thimbles, 400mm long stay bow and GI nuts, washers including loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No 1 on Ser Page No 495 of MES Schedule Part-I (2009) complete all as specified and directed. Note : Stay clamp, Stay wire, excavation and earth work and concrete for stay pit shall be measured and paid separately.
Supply and straining of ACSR condutor of any size on HT over head line including necessary binding work, jumpering, maintaing proper sag as per IE Rule including cutting of tree branches around the ACSR with in area of 2 mtr dia all as specified and as directed.
All as per item No. 24 above, but restraining of old serviceable ACSR conductor of any size including maintaining proper span sag complete all as specified and directed by Engr-in-Charge.
Galvanised steel wire 3.15/4 mm dia as in contenious earth wire/guard or cradle wire made to shape hexagonal/rectangular fixed on poles for LT feeder including binding the same with new GI binding wire not less than 2 mm dia complete all as specified & as directed.
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting a side serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
Cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT/LT over head line and painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed by Engr-in-Charge.
Fixing only old serviceable cross-arms obtained from ser itm No 27 with providing new bolts, nuts and washers as reqd including painting with one coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting a side serviceable insulators for reuse in the same work & removing unserviceable insulator from site complete all as specified & as directed.
Pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for 11000 volts grade, complete all as specified & as directed.
Description all as per item No. 31 above, but fixing only old serviceable pin type insulator as obtained from item No 30 here-in-before after through visual checking and testing with HT megger all as directed by Engr-in-Charge.
Description all as per item No. 31 here-in-before, but for 33000 Volt Grade all as directed by Engr-in-Charge.
Disc type insulator, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brown or green "two in series" assembly for tension with tension clamps for conductors working pressure 11000 Volts, complete all as specified & as directed..
Disc type insulator, porcelain, vitreous 300 mm height and 300 mm dia ball and socket type, white, brown or green "two in series" assembly for tension with tension clamps for conductors working pressure 33000 Volts, complete all as specified & as directed.
All as per item No. 34 here in before but fixing only old serviceable single disc assembly as obtained from item No 30 here-in-before after thorough visual checking and testing with HT megger all as directed by Engr-in-Charge.
All as per item No. 36 here-in-before, but for 33000 Volt Grade all as directed by Engr-in-Charge.
Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 11000 volts grade, 150 mm dia 150 mm height including galvanized mild steel straps of 35 x 5 mm size, 20 mm dia insulator bolts, washers and nuts complete all as specified.
Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 33000 volts grade, 300 mm dia 300 mm height including galvanized mild steel straps, insulator bolts, washers and nuts of required size, complete all as specified.
Replacement of stay wire stranded 7/3.15mm including stay clamp and fixing arrangement complete all as specified
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 8mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
Description all as per item No above but with 32 x 6 mm strip earthing & light grade GI protection pipe 40mm.
Supply and replacement/topping up of transformer oil of dielectric strength not less than 40 KV in the transformer / Voltage stabilizer installed at site in various location under Nowshera (South and North Zone) Garrison complete all as directed .
Draining out of transformer oil from floor mounted 11/.433 KV transformer and de hydrating using centrifuzing machine till its die electric strength reach 60 KV and filling the same into transformer complete all as directed by Engr in Charge Note:- i) The contractor shall provide elect supply (DG set) for running centrifuzing machine ii) The transformer oil shall be tested with transformer oil die electric strength testing equipments before and after de hydration of the transformer oil
Material & labour for painting of transformer indoor/ outdoor on plinth/ pole mounted with one coat of synthetic enamel gray paint from compressor spray Gun after removing all dust. rust. Paint shall confirmed to IS-2032 and writing SM & MES No of size 2” long by painter with white paint as directed by EIC for following capacity of transformer ;-
a) 25 KVA to 100 KVA transformer
(b) 200 KVA to 315 KVA
Painting to old painted HT poles, 11m high with one coat of synthetic enamelled paint over two coats synthetic enamel aluminium paint including scrapping the old paid carefully to make smoothen complete and painting strips of yellow & black from foot of pole upto 5 feet each strip of 30 cm height, complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11 KV grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing in replacement lightening arrester expulsion type complete with all fittings transmission class , discharge capacity 65 kilo Amps suitable for 11000 Volts complete all as directed by Engr in Charge.
Material and labour in repair for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Material and labour in repair for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M & L for testing calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system through authorised dealer for smooth functioning and VCB should be tripped at any type of fault developed in feeders complete all as specified and directed. Note :- (a) Contracor will submit primary and secondary test record at the time of calibration of HT VCB duly signed by the technical (b) Replacemnt of unservicable item will be measured and paid separatly .
Supply and fix in replacement, testing for desired value of 1250 Amp Vaccume interupter, complete all as specified and directed. Make - Electric feild / ABB/ CG
Supply and fix in replacement, testing of AM 96 x 96 mm with MS plate with accuracy 1.00 with CT s, complete all as specified and directed. Make - Electric feild / ABB/ CG / Schneider
Supply and fix in replacement, testing of VM 96 x 96 mm with MS plate with accuracy 1.00 with CT s Make - Electric feild / ABB/ CG / Schneider.
Supply and fix in replacement,testing of Spring charging motor 80W,220V, AC/DC, complete all as specified and directed. Make - Electric feild / ABB/ CG / Schneider.
Supply and fix in replacement of LED lamp 30 V DC, complete all as specified and directed.
Supply and fix in replacement of breaker control switch as per existing type, complete all as specified and directed.
Supply and fix in replacement, testing of Master trip relay, complete all as specified and directed. Make -Ashida/ Schneider/ABB
Supply and fix in replacement of Limit switch, complete all as specified and directed. Make - Electric feild / ABB / CG / Schneider
Supply and fix in replacement of Drive insulator, complete all as specified and directed. Make - Electric feild / ABB / CG / Schneider.
Supply and fix in replacement of copper Bus bar as per existing suitable size, complete all as specified and directed.
Opening of complete 11000 volts/440 volts step down transformer outdoor/indoor type of capacity 25 KVA to 100 KVA including draining out transformer oil, removing of sludge from bottom of the tank, dismantling of core and remove HT/LT coil for replacement and re fixing new HT/LT coils including internal connections, refilling of new oil, replacement of top gasket and deficient nuts , bolts and testing complete after repairs (Note - re-winding of HT & LT coils and oil shall be measured and paid for separately). The cost of gaskets, nuts and bolts etc will be deemed to be included in this above item quoted rate .
Description all as per the description of srl item No 54 above but capacity of transformer more than 160 KVA and upto 315 KVA.
M&L for Replacement of burnt out /unserviceable transformer HT coil/winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of transformer including all insulating papers and material required for making of coil complete all as specified and as specified and directed by EIC.
M& L for Replacement of burnt out /unserviceable transformer LT coil/winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of transformer including all insulating papers and material required for making of coil complete all as specified and as specified and directed by EIC.
M &L for replacement of HT bushes with brass stud complete for transformers 11000 volts grade suitable for transformer capacity 250 A, complete all as specified and directed.
Supply & fixing in repairs of brass stem set (stud) with porcelain insulator ,rubber bush of suitable size of length for LT side terminals with brass nuts eight Nos and rubber seals of 250 Amps complete all as specified and as directed .
Supply & fixing in repairs of brass stem set (stud) with porcelain insulator ,rubber bush of suitable size of length for LT side terminals with brass nuts eight Nos and rubber seals of 400 Amps complete all as specified and as directed.
Opening the old breathing apparatus and removing the old unserviceable silica gel and refilling with new silica gel to the required level to various size of transformers at different locations, complete all as specified and directed.
M&L for replacement of unsv breather with new breather apparatus set suitable for various transformers of capacity up to 63 KVA including refilling with new silica gel to the required level to various transformers at different locations, complete all as specified and directed.
M & L for replacement of unsv breather with New breather apparatus set suitable for various transformers of capacity 100 KVA including refilling with new silica gel to the required level to various transformers at different locations, complete all as specified and directed.
M& L for replacement of unsv breather with New breather apparatus set suitable for various transformers of capacity 160 KVA to 300 KVA including refilling with new silica gel to the required level to various transformers at different locations, complete all as specified and directed.
Anti climbing device spikes type fabricated out of M.S bars ( Round , Square and flat ) including nuts, bolts, washersand welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, bigures and conventional shull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of HT 25 x 20 cm size, complete all as specified and directed.
Cutting /Trimming/ Chopping of tree trenches along the overhead lines upto 2 m from electric lines clearance on all sides of overhead lines and disposing off the cut tree/ branches site to a distance not exc. 50 m and clearing the site as directed by Engr-in-Charge.
Supply and fixing in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 sqmm, complete all as specified.
Supply and fixing in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified.
Supply and fixing in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified.
Supply and fixing in repair station class surge lightening arrester complete with all fittings transmission class , discharge capacity of maximum continuous operating voltage rating (MCOV) 7.65 KV suitable for 33000 Volts complete all as directed by Engr in Charge.(Model No- AS03N0009, Ser No 1287)
Supply and fixing in repair morestor gapless surge arrester of 30 Kva,10 KA class-2 type STN-DT complete with all fittings transmission class , discharge capacity suitable for 33000 Volts complete all as directed by Engr in Charge.
M & L RCC route/joint marker for 11/33 KV of size 800 mm x 300 mm x 120 mm for cabeling route mark including painting with white base colour and letters with black colour of size 5 mm complete all as specified and as specified and directed by EIC.
M/S Jasbir Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .