Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | Admitted-Fee/PreQual/Technical |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
PREVENTIVE MAINT AND REPAIR OF INTERNAL ELECTRIC SUPPLY, INTERNAL POINT WIRING OF MD ACCN AND INTERNAL WORK AT INS HAMLA UNDER GE (NW) BHANDUP
2025_MES_739925_1
8416/B
Open Tender
Civil Works
Item Rate
270 days
INS HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹60,000
Yes
6 Dec 2025
14 Nov 2025
13 Dec 2025
14 Nov 2025
12 Dec 2025
28 Nov 2025
14 Nov 2025 - 24 Nov 2025
Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed by Engineer In Charge.
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with all fittings, accessories, PVC junction boxes etc. with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. for the following
One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge.
Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed by Engineer In Charge.
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed by Engineer In Charge.
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed by Engineer In Charge.
One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed by Engineer In Charge.
One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge.
(g) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed by Engineer In Charge.
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge for the following
One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
Description all as per 6 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge.
One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
Note for Item Ser No 3 to 11: (i) Cutting chases for conduits and sinking's for GI metal switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department. (ii) Partially partly wiring in casing caping with all fittings accessories PVC junction boxes whereever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoated against item.
Supply and fixing Modular switch, one way 6 A, one module, 230 Volts complete all as specified and as directed by Engineer In Charge.
Supply and fixing Modular switch, one way 16 A, one module, 230 Volts complete all as specified and as directed by Engineer In Charge.
Supply and fixing Modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed by Engineer In Charge.
Supply and fixing Modular socket outlet multipurpose, 6A/16A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed by Engineer In Charge.
Supply and fixing Switch piano, flush type, polycarbonate, single pole, one way 6 Amp complete all as specified and as directed by Engineer In Charge.
Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and as directed by Engineer In Charge.
Description all as per 9 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge.
Supply and fixing in repairs Modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of
Supply and fixing 16 Amps Top Plug with Indicator complete all as specified and as directed by Engineer In Charge.
3 Module
4 Module
6 Module
8 Module
12/16 Module
Supply and fixing in repairs GI metal flush boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, suitable for mounting modular white cover plate of size
18 Module
3 Module ( Make- Legrand Cat No - 6890 08 or equivalent )
4 Module ( Make- Legrand Cat No - 6890 09 or equivalent)
6 Module ( Make- Legrand Cat No - 6890 10 or equivalent )
8 Module ( Make- Legrand Cat No - 6890 42 or equivalent )
12/16 Module ( Make- Legrand Cat No - 6890 11 or equivalent )
S & F Highly efficient LED Motion sensor Bulbs, 10 W, output of 900 lumens, cool white, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap, complete and standard warranty of manufacturer from date of purchase/ installation complete all as specified and as directed by Engineer In Charge.
18 Module ( Make- Legrand Cat No - 6890 12 or equivalent)
(a) 3 Module ( Make- Legrand Cat No - 6733 03 or equivalent)
(b) 4 Module ( Make- Legrand Cat No -6733 04 or equivalent )
(c) 6 Module ( Make- Legrand Cat No - 6733 06 or equivalent )
Note for Item Ser No 12 & 39 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated. (ii) Making good disturbed wall in cement mortar 1:3 , & with wall puti for concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department
Supply and fixing TV Co - axial Socket - 01 Module complete all as specified and as directed by Engineer In Charge. Make- Legrand Cat No- 5734 25 or Equivalent in Havells.
Supply and fixing USB Charger - 3000mA/15 Watts - Type A + C -1 Module complete all as specified and as directed by Engineer In Charge. Make- Legrand Cat No- 5716 88 or Equivalent in Havells.
Supply and fixing 3mm thick white (Hylam) sheet for electrical application to incorporate switches, sockets etc including Cutting, drilling, shaping of material to site requirement and fixing with brass cadmium screws of adequate size and length complete all as specified and as directed by Engineer In Charge.
Supply and fixing wall/ surface mounted, LED-10 W watt Power consumption, AL. Extruded Housing, Input Voltage 140 V AC - 270 V AC, 50Hz, IP 20, batten fitting complete with standard warranty of manufacturer from date of purchase/ installation complete all as specified and as directed by Engineer In Charge. Make-Havells Cat No- LHEXACP7IN1W010 or Equivalent in Philips, Jaquar. Cat No- BTI-WHT-LGLZ01X010XW
Supply and fixing Energy efficient, Twinglow 25-Watt+25-Watt Led Up-Down Batten (Warm White + Cool White), polycarbonate material, 4' Tubelight fitting, 2500 Lumen complete with standard warranty of manufacturer from date of purchase/ installation complete all as specified and as directed by Engineer In Charge. Make-Philips (Product SKU : 919515813875) or equivalent in Jaquar, crompton
Note for Item Ser No 40 & 48 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated.
Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
S & F wall surface mounted LED Wall Lamp luminaire fitting Chrome Finsh with inbuilt 6W LED round focus spot light complete all as specified and as directed by Engineer In Charge. Make :- Jaquar Cat Part No DWL-CHR-WL5048X6W or its equivalent in Philips, Orient, Crompton
SP 5 To 32 AMP
SPN 32 AMP
Supply and fixing 415V 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
SPN 40 to 63 AMP
TP 25 To 63 AMP
TPN 16 To 32 AMP
TPN 40 To 100 AMP
SPN 8 Way. (Make Legrand Cat No - 5076 11 or equivalent. ).
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar, Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed by Engineer In Charge.
SPN 4 Way. (Make Legrand Cat No - 5076 10 orequivalent.)
SPN 12 Way. (Make Legrand Cat No - 5076 12 or equivalent. ).
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar for each phase, Fully insulated & shrouded Neutral bars, Earthbar and Cable ties for Cable management, & provision for FP MCB / Isolator / RCCB / RCBO as incomer and SP MCB's as outgoing ,415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed by Engineer In Charge.
TPN 4 Way. (Make Legrand Cat No -5076 80 orequivalent.)
TPN 6 Way. (Make Legrand Cat No -5076 81 orequivalent).
Supplied and fixed Flush Mounting and Surface Mounting single pole and neutral sheet metal enclosure suitable for 240 V with neutral link, two pin, earth plug and socket plug top complete all as specified and as directed by Engineer In Charge and as directed with
One Single pole MCB upto 20 Amps
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 250 Amps rated bus bar for each phase, Fully insulated & shrouded 2 Neutral bars, 2 Earthbar and Cable ties for Cable management, & With provision for DPX³ 250 MCCB as incomer and SP/TP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed by Engineer In Charge.
VTPN 4 Way. (Make Legrand Cat No - 5077 58 orequivalent.)
Note for Item Ser No 49 & 54 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated. (ii) Making good disturbed wall in cement mortar 1:3 , & with wall puti for concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department
VTPN 8 Way. (Make Legrand Cat No - 5077 59 orequivalent).
of walls, floors as per the existing finishes complete all as specified and as directed by Engineer In Charge.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
Supply and fixing Medium duty SS 304 CABLE PERFORATED TRAYS, rust proof, in standard length of 2.5 Mtr, thickness - 3.0 mm, and height of tray 50mm complete with side SS couplers plates to connect cable trays with each other, SS couplers cable tray bends, and supporting accessories of GI (Galvanized Iron) Threaded Rods, Fasteners, with nuts, bolts, washers etc for fixing cable tray on walls or hanging with ceilings all as specified and as directed complete width of
M & L for submain wiring with approved colour coding as per IS with four single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. Note- Five run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with four single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit of suitable size including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed by Engineer In Charge. Note- Five run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed by Engineer In Charge.
Cable Tray 150mm
Note :- Supporting hanging/ wall fixing accesssories, shall be fixed at minimum length 01 Mtr span and will be measured as one length along with cable tray. Rate quoated shall deemed to be included in the unit rate quoated
Labour for taking down of unserviceable ceiling fan of any sweep and make after disconnecting cable end terninal from ceiling rose, dismantling blades and hanging serviceable fan at same location of any sweep, make by connecting cable end terminal to ceiling rose, after fixing blades at site with fan, testing for smooth running complete all as specified and as directed.
Note : Transportation to & fro involved of unserviceable ceiling fan to deposit in EM Store yard Hamla and back to site hanging serviceable fan after collecting from store is deemed to be included with unit rate.
Servicing / over hauling of ceiling fan 230 Volts of any make and sweep, along with following others repairs. a). Dismantaling of ceiling fan complete part by part carefully, testing stator coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts b) Heating & varnishing to stator coils with super quality varnish and dried out properely with external heat as ordered & directed. c) Reassembeling of ceiling fan complete with all existing serviceable parts obtained against Item 1 (a), and new parts as required / ordered by Engineer in Charge.
Note (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoated against this Item. (ii).Any unforeseen minor repair and minor parts that are not covered under Item No-86 , (a) to (c) ( Total cost less than Rs 100 ) but required to complete the repair work / smooth functioning of fan shall be deemed to be included with the unit rate. (iii) Transportation of fan to workshop for repair and back to site in EM store yard at Hamla is deemed to be included with unit rate. (iii). Rewinding of stator coils of ceiling fan , where involved shall be measured and paid separetely against relevant item of this schedule. (iv) 3 core PVC insulated and sheathed 0.75 Sqmm cable from ceiling rose to fan connector of adequate length (maximum upto 1 Mtr) and (greasing the bearing with ball bearing grease where involved) shall deemed to be included in the unit rate.
Cable Tray 200mm
Cable Tray 250 mm
Cable Tray 300mm
Ball bearing rubber sealed for bottom cover 6201 or as per existing
BLDC ceiling fans Printed Circuit Board (PCB) controller 28 Watt -32 Wattt for 5 Star rated fans of Make- Bajaj, Crompton, Havells.
Taking down chowkat or frame ( Wooden) / Steel not exc. 1.5 sq. m and removing to store complete all as specified and as directed by Engineer In Charge.
S & F Highly efficient 12 Watt, B-22 , Back up LED Bulb cool white, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap, complete and standard warranty of manufacturer from date of purchase/ installation
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
TENDERDOCUMENTS.pdf
Tender Documents • 1.82 MB
BOQ_828515.xls
BOQ • 1.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .