Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 CrAccepted-AOC 57 C STREET NO 6 WEST RAJIV NAGAR 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹15.9 Cr Quoted ₹16.9 Cr | L1 | Accepted-AOC awarded |
| 2 | L2₹18.0 CrRejected-Finance 1 20 ASAF ALI ROAD NEW DELHI 110002 | CENTRAL | DELHI | 110002 | ₹18.0 Cr | L2 | Rejected-Finance L2 hence rejected |
| 3 | L3₹18.8 CrRejected-Finance 701 702 7TH FLOOR TOWER A SIGNATURE TOWER SOUTH CITY 1 SEC 30 GURUGRAM HARYANA 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹18.8 Cr | L3 | Rejected-Finance L3 hence rejected |
| 4 | L4₹20.7 CrRejected-Finance NAI MANDI BEHAL 127028 DISTRICT BHIWANI HARYANA | BEHAL | BHIWANI | HARYANA | 127028 | ₹20.7 Cr | L4 | Rejected-Finance L4 hence rejected |
| 5 | L5₹25.5 CrRejected-Finance | ₹25.5 Cr | L5 | Rejected-Finance L5 hence rejected |
Tender Value
₹18.0 Cr
EMD Value
₹36.0 L
Closing Date
27 Dec 2022, 5:00 pmClosed
Shitij Kumar
Division - Electrical
Erection of 33/11KV substation in STP Behrampur and its associated 33KV feeder circuit line though underground cable from Sector-72 220KV HVPNL Substation, Gurugram.
2022_HRY_248305_1
20227A05EE6D 5C34 477A B4DE 7CF9E9DF6DF81838001
Open Tender
Electrical Works
870 days
Gurugram
2 documents required · 2 mandatory
₹1,000
₹36.0 L
Yes
5 Apr 2023
2 Dec 2022
28 Dec 2022
2 Dec 2022
27 Dec 2022
2 Dec 2022
Amount
11 kV Equipments : Supply , installation , testing and commissioning of 11kV 3-phase Double break Isolator alongwith line side earthswitch as per DHVBN specification.
11 kV Equipments : Supply , installation , testing and commissioning of 9kV station type perclain surgearrester w/o surge counter.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Bracing Angle made out of MS, ( ISA 50x50x6 Lg 2700mm,, Wt. 4.5 Kg/mtr.). Total Quantity 204 Nos. Weight of Each Bracing Angle = 12.15 Kgs
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Clamps for Bracing Angle and Belt Angle for D/P and F/P Structures made out of MS Flat ( Top and bottom Clamps 65x8 mm MS Flat 4.1 Kg/mtr.).. Total Quantity 816. Weight of Each Clamp = 3.69 Kgs
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Clamps for V Cross Arm, pin support chanel , Horizontal Cross Arm, Guard Chaneland Stay set made out of 75x8 mm MS Flat, (weight 4.73 Kg/mtr.), Total Quantity 1062 Nos., Weight of each Clamp = 2.53 Kgs.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Guard Chanel for S/P Fabricated out of MS ( ISMC 100 X 50 ( Lg. 1825mm, 9.2 Kg/mtr), Total Quantity 22 Nos. Weight of Each Guard angle= 16.73 Kgs.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Horizontal Cross Arm for D/P Structures made out of MS ( ISMC 100x50x6mm, 9.2 Kg/mtr.) forTension type and Suspension Type. Total Quantity Nos. 195, Weight of each Cross Arm = 24.38Kgs.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Galvanised GI Nuts, bolts and washers as required for erection of pole / line hardware
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Hardware Fittings - PG Clamps suitable for ACSR `Dog`
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Insulators - 10 KN 11 KV Pin Insulator alomg with pin with 540 mm creepage as per IS
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of 11 Meter Single PCC poles 400kg of size 415x140 mm at bottom and 200x140 mm at top as per DHVPN specifications [S/P=21 locations: D/P=4locations]
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of GSS 7/8 SWG (4mm) for earthing. Weight= 153gm/Mtr.(2393 mtrs)
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Stay set ( 20 m dia 2.5 m long with 1 No. turnbuckle( 20mm), disc insulator, chanel ISMC 100x50x6 mm 2 no. stay wire 7/3.15mm, 11 metre
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of Top Chanel for supporting Pin insulator made out of ISMC 100X50mm ( 9.2 Kgs/mtr). Total Quantity 21 Nos., Weight of each Top Chanel = 3.68 Kgs.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply of V Cross Arm for S/P fabricated out of MS,( ISMC 100x50mm, weight =9.2 Kg/mtr.). Total Quantity 22 Nos., weight of each V cross Arm= 13.34 Kgs.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole: Supply of Belt Angle made out of MS, ( ISA 50x50x6, Wt. 4.5 Kg/mtr.). Total Quantity 204 Nos. Weight of Each Belt Angle = 9.84 Kgs
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole: ACSR `Dog` Conductor for 11 KV Lines.
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Conductor and Earthwire Accessories- Mid span compression joint for ACSR Dog conductor
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply and Erection of GI earth wire 5mm for all metallics
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Line Hardware and Accessories-Danger Plate
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Supply and Erection of GI Flat size 25X6mm including fabrication for earting
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : 20 mm dia, Galvanised Rod, 2500mm long for Earthing
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Conductor and Earthwire Accessories- Repair Sleeve for ACSR Dog Conductor
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Line Hardware and Accessories- Anti climbimg device
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Line Hardware and Accessories- Phase Plate ( Set of three)
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole : Line Hardware and Accessories-Number Plate
11 KV Single and Double Circuit Line to be constructed on 11 Meter PCC pole :- Disc Insulators - 45 KN ,11 KV Disc insulators ,16mm ball and socket type with pin and Tension Fitting bolted type complete with eye bolt, hook, nuts and bolits etc. Complete Suitable for ACSR `Dog` Conductor.
11 KV Switchgear Panel 12kV, 500 MVA for 3 Secs., 1600A, indoor VCB switchgear panel with required PTs, CTs, protective relays, metering equipment, auxiliary equipment, extensible (both sides) copper busbars, complete cable termination kits as per cable sizes specified in SLD 630A Incoming (4 Nos) 630 A outgoing feeder (2 Nos) 630 A station transformer (1 No) 630 A capacitor bank (1 Nos) 1250 A Bus Coupler Panel (1 Nos) Bus PT/Bus Riser Panel (1 Nos) BPT (1 Nos) Note :*The 11 KV Switchgear board shall be compatible with SCADA system as defined in the technical specifications.
250 MM DIA HDPE Pipes for Road Crossing of cables
250 MM DIA HDPE Pipes for Road Crossing of cables.
33 KV Yard : Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.Thermo-Mechanically Treated bars of grade Fe-500D kg or more(for M-30) .
33 KV Yard :- Designing and construction of yard with 100mm thick C.C of M30 concrete after preparation of plinth( i.e compaction and filling of soil followed by 75mm M-10 concrete and so as to achieve the final plinth level which should be 0.75 meter above the existing road level of Behrampur STP.) including cable trenches , all electrical , mechanical works in accordance with approved design and drawings and all other works contingent thereto as per sizes and specification given in DNIT(Item for M-10).
33 KV Yard :- Designing and construction of yard with 100mm thick C.C of M30 concrete after preparation of plinth( i.e compaction and filling of soil followed by 75mm M-10 concrete and so as to achieve the final plinth level which should be 0.75 meter above the existing road level of Behrampur STP.) including cable trenches , all electrical , mechanical works in accordance with approved design and drawings and all other works contingent thereto as per sizes and specification given in DNIT(Item For M-30).
36 kV Equipments : Supply , installation , testing and commissioning of 33kV 3-phase Double break Isolator alongwith line side earthswitch as per DHVBN specification.
36 kV Equipments : Supply , installation , testing and commissioning of 33kV Metering Cubicle alongwith Shed as per DHVBN specification
36 kV Equipments : Supply , installation , testing and commissioning of 30kV station type perclain surgearrester alongwith surge counter.
AC Distribution Board AC 415V, 500A ,50 KA for 1 Sec cubicle type Indoor, floor mounted, auxiliary service board as per specification comprising of : 2 No. - Incoming feeders each with 400A TPN MCCB/ACB (Microprocessor Based) with O/C, S/C, E/F release. Suitable to operate from remote and all status to be taken to SCADA , 1 Nos. - Outgoing feeders with 100A TPN MCCB , 3 Nos. - Outgoing feeders with 63A TPN MCCB , 4 Nos. - Outgoing feeders with 32A TPN MCB , 4 Nos. - Outgoing feeders with 32A DP MCB ,
Air conditioning : Steel Tubular Pole , 10 Meter long ,SP45,as per IS, with 1.5 Meter high lightning spike to act as Lightning Mast., complete with base plate of 300x300x10mm MS and arrangement for fixing the spike to be erected in ground with minimum planting depth of 1/6 of pole
Air conditioning: PVC Pipe , 100mm Dia , 4 Kg/Sq.cm for Control Cable crossing
Air conditioning: Window Airconditioning for SCADA room and engineers room (capacity 1.5 TR)
Air conditioning: HDPE Pipes for Road Crossing of Control cables
Air conditioning: RCC, Hume pipes class NP2 for laying power ables under the roads: Size 300 mm dia / 250 mm Dia
Battery and Battery charger 48V DC battery charger suitable for float and Float cum boost charger as per specification and with a common DCDB comprising of : Battery Charger = 1 sets 1 No. incomer with 250A, DP DC MCCB and to terminate 2 core 50 sqmm Al.cable. 12 Nos. outgoing feeders each with 40/32 A DP rotory switch with HRC fuses as per the requirement and as per the approved drawings
Battery and Battery charger 48V DC battery charger suitable for float and Float cum boost charger as per specification and with a common DCDB comprising of : Supply of fitration industrial socket 100A mounted on support out door type IP 67
Battery and Battery charger 48V DC, 350 AH lead acid battery of plante type complete with accessories as per specification with 10% spare acid in non-returnable container (In tier arrangement)
Boundary wall:- Designing and construction of boundary wall of 33 KV substation in Behrampur STP with height shall be 1.50Mtr with RCC pillar @3Mtr C/C as per design / drawing foundation of boundary wall shall be minimum 0.90m below natural ground level.
CABLE JOINTS : Aluminum Clamp for fixing Cable in Structurefor 11kV 3Core 400 sq mm.
CABLE JOINTS : Normal Straight Through Joint suitable for 11KV, 400 sqmm X 3 Core AL Cable as per technical specification.
CABLE JOINTS : Normal Straight Through Joint suitable for 33KV, 630 sqmm X 1 Core AL Cable as per technical specification.
CABLE JOINTS: Aluminum Clamp for fixing Cable in Structure for 33kV 1Core 630 sq mm.
CABLE JOINTS: Trifoil clmap used during laying of cable (if any) for 1c x 630 sqmm cable 33kV
Cable Supports and Trays: Sheet steel (thickness 2.5 mm)Galvanised ladder and perforated type cable trays with its accessories to be laid in indoor cable trenches ( of following various sizes ).150mm and 100mm width, as per requirement for dressing , Cable Trays for Control cable dressing at Transformers : 100 x 50 mm perforated type
Cable Supports and Trays: Sheet steel (thickness 2.5 mm)Galvanised ladder and perforated type cable trays with its accessories to be laid in indoor cable trenches ( of following various sizes ).150mm and 100mm width, as per requirement for dressing , Cable Trays for Control cable dressing at Transformers: 150 x50 mm perforated type
CABLES : 12 KV Heat Shrink type termination Kit for the following size of 12 kv(E) XLPE Cables - 3 core x 400 sq.mm (Indoor type )
CABLES : 12kV XLPE (E) insulated `PVC sheathed, aluminium round wire armoured, aluminium conductor cable of the following size : 3 core x 400 sq.mm (Aluminium round wire armoured)
CABLES : 36 KV Heat Shrink type termination Kit for the following size of 33 kv(E) XLPE Cables 1Core 630 sq mm : (Indoor type )
CABLES : 36 KV Heat Shrink type termination Kit for the following size of 33 kv(E) XLPE Cables 1Core 630 sq mm- Indoor type
CABLES : 36kV XLPE (E) insulated `PVC sheathed, aluminum round wire armoured, aluminum conductor cable of the following size : 1 core 630 sqmm (Aluminum round wire armoured) for 33 KV line and Transformers
CABLES : 36kV XLPE (E) insulated `PVC sheathed, aluminum round wire armoured, aluminum conductor cable of the following size : 1 core 630 sqmm (Aluminum round wire armoured) for 33 KV line and Transformers.
CABLES : 11kV XLPE (E) insulated `PVC sheathed, steel round wire armoured, aluminium conductor cable , 3 core x 240 sq.mm (steel round wire armoured) for capacitor banks (2 Runs)
CABLES : 12kV XLPE (E) insulated `PVC sheathed, aluminium round wire armoured, aluminium conductor cable of the following size : 3 core x 400 sq.mm (Aluminium round wire armoured)
Cables : 12KV XLPE (E) insulated `PVC sheathed, steel round wire armored, aluminum conductor cable , 3 core 240 sq.mm (steel round wire armored) for 11/0.415 KV station Auxiliary transformer.
CABLES : 36 KV Heat Shrink type termination Kit for the following size of 33 kv(E) XLPE Cables 1Core 630 sq mm : (Outdoor Type)
CABLES : 12 KV Heat Shrink type termination Kit for the following size of 12 kv(E) XLPE Cables - 3 core x 400 sq.mm (Outdoor type)
CABLES : 36 KV Heat Shrink type termination Kit for the following size of 33 kv(E) XLPE Cables 1Core 630 sq mm- Outdoor type
Cables: 12 KV Heat Shrink type termination Kit for the following size of 12 kv(E) XLPE Cables 3 core x 400 sq.mm: (Indoor type)
CABLES: 12kV Heat shrink type termination kit for 12kV (E) XLPE Cables of 3 Core x 240 sq.mm size. , Indoor type
Cables: 12 KV Heat Shrink type termination Kit for the following size of 12 kv(E) XLPE Cables 3 core x 400 sq.mm: (Outdoor type).
CABLES: 12KV XLPE (E) insulated `PVC sheathed, steel round wire armoured, aluminium conductor cable , 12kV Heat shrink type termination kit for 12kV (E) XLPE Cables of , 3 Core x 240 sq.mm size , Indoor type
CABLES: 12kV Heat shrink type termination kit for 12kV (E) XLPE Cables of 3 Core x 240 sq.mm size. , Outdoor type
CABLES: 12KV XLPE (E) insulated `PVC sheathed, steel round wire armoured, aluminium conductor cable , 12kV Heat shrink type termination kit for 12kV (E) XLPE Cables of , 3 Core x 240 sq.mm size , Outdoor type
Conducting reconnoitery survey along shortest route with best proposed route of cable route including evaluation of thermal resistivity of the soil with the cable route .Excavation of trial pits as per field requirements. Preparation of cable route profile, drawing of cable laying final route alignment, marking lines and grades and recheck bill of materials / lengths of the cable for the projects.as per the directions of Engineer-in-charge at site
Conducting reconnoitery survey along shortest route with best proposed route of cable route including evaluation of thermal resistivity of the soil with the cable route .Excavation of trial pits as per field requirements. Preparation of cable route profile, drawing of cable laying final route alignment, marking lines and grades and recheck bill of materials / lengths of the cable for the projects.as per the directions of Engineer-in-charge at site.
Control room building :- Designing and construction of RCC M-25 Framed structure building confirming to national building code for building in accordance with approved design and drawings with single story building height 5.00mtr or more as required, including cable trenches , all electrical , mechanical and Sanitary works and all other works contingent thereto as per sizes and specification given in DNIT.
Design and Construction of 3.75 to 5.00 M wide internal CC Roads for complete project with embankment as required gradient with 150mm thick (1:3:6) with concrete base and 200mm thick M-25 Design Mix Concrete with Kerb and channels including construction of CC drain connecting to MPS, Supplying and installing of 8.00 Mtr. high LED solar street light at 30M c/c, Main gates, walkways, leveling etc. complete in all respect and any other work contingent thereto.
Double compression glands and terminations (including ferruling, suitable Cu Lugs to meet the system requirements) for 1100V grade PVC insulated multicore Copper stranded conductor control cables of the following sizes: Copper Control Cable , 3 core x 2.5 Sq.mm , 4 core 2.5 sq.mm , 10 core 2.5 sq.mm , 2 Core 6 sq.mm , Aluminium Power Cables , 3.5 Core x 35 sq.mm (Aluminium) , 4 Core x 10 Sq.mm ,
Earth mat for 33KV yard :- Design , supply , and erection of earth mat work which includes 16mm thick rod and 20mm thick earth electrodes in accordance with approved design and drawings including excavation and refilling of soil complete in all respect and any other work contingent thereto as per sizes and specification given in DNIT(Steel reinforcement, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more).
EARTHING AND LIGHTNING PROTECTION : Earthing riser and earthing conductor for earthing of , LT panel, Junction box, cable tray supports in trenches and switchgear/control room building etc., (50x6 GI flat).
EARTHING AND LIGHTNING PROTECTION : Earthing riser for builing spikes rod (50x6 GI flat).
EARTHING AND LIGHTNING PROTECTION : Electrolytic grade copper plate 600mmx600mmx6mm for Instrumentation and SCADA System to be provided in 4.5 mtr deep earth pit to be filled with salt and charcoal (as per standard IS).
EARTHING AND LIGHTNING PROTECTION : Main Earth mat Conductor and Risers for Main Equipments etc ( 75 x 12 mm G I flat).
EARTHING AND LIGHTNING PROTECTION : Transformer neutral earthing with 50x6mm copper flat.
EARTHING AND LIGHTNING PROTECTION : 3 Meter long, 40 mm Dia Rod electrodes in Treated pits for Lightning laid in 3 Meter earth pit.
EARTHING AND LIGHTNING PROTECTION : 40 mm Dia 3.0 Mtr GI Pipe earth electrode with treated pit.
EARTHING AND LIGHTNING PROTECTION : Electrolytic grade copper plate 600mmx600mmx6mm for transformer neutral earthing to be provided in 2.5mtr deep earth pit is to be filled with salt and charcoal (as per standard earthing Practices).
Foundation :- Steel structure for the following foundations:- Foundation of 33 KVA transformers , and all other foundations as required as per drawings and Engineer-in-charge as needed and in accordance with approved design and drawings complete in all respect and any other work contingent thereto as per sizes and specification given in DNIT(Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.Thermo-Mechanically Treated bars of grade Fe-500D kg or more( for M-30) .
Foundation :- Design and construction of RCC Grade M30 Using Concrete Mixer C.C of M30 concrete platforms for , Foundation of 33 KVA transformer , and all other foundations as required as per drawings and Engineer-in-charge , including excavation and back filling as required to the complete satisfaction of Engineer-in-charge as needed and in accordance with approved design and drawings including excavation and refilling of soil complete in all respect and any other work contingent thereto as per sizes and specification given in DNIT
Lighting : Flood light fitting with `250 W LED fixture with min 80lx/watt output and control gear for outdoor lighting to be installed on 10m SP410 Steel tubular pole complete with mounting bracket.
Lighting : Steel Tubular Poles 10M long for mounting the yard lighting complete with mounting brackets, nuts , bolts as required.
Lighting : Post top lantern with 35W LED lamp with control gear complete with necessary support pipe and bracket, conduit, wire and junction box.
Lighting: Lighting junction box for each Light suitable for out door installation comprising of 4 no. CBT M 4 type terminal connector for light connections Max size 150 x150x100mm.
LT CABLE 1.1kV XLPE insulated `PVC sheathed, GI round wire armoured, aluminium conductor cable of the following sizes: 3.5 core x 300 sq, mm for station transformer
LT CABLE 1.1kV XLPE insulated `PVC sheathed, GI round wire armoured, aluminium conductor cable of the following sizes: Termination with double compression gland and Al lugs for 3 1/2 core x 300 sq, mm cable
LT CABLE : 1.1 KV PVC insulated and sheathed, steel wire armored Aluminimum conductor cable of the following size (For AC and DC Supply) 3.5 core x 50 sq.mm, steel wire armored for outdoor Industrial Multi Socket -3 Phase.
LT CABLE : 1.1 KV PVC insulated and sheathed, steel wire armored Aluminimum conductor cable of the following size (For AC and DC Supply) , 2 core x 50 sq.mm copper cable(For Battery Charger)
LT CABLES: Double compression glands and Cu/Al lugs with sleeves for 1100V grade PVC insulated, multicore aluminium conductor auxiliary power cables of the following sizes: 2 core x 50 sq.mm copper cable.
LT CABLES: Double compression glands and Cu/Al lugs with sleeves for 1100V grade PVC insulated, multicore aluminium conductor auxiliary power cables of the following sizes: 3 1/2 core x 50 sq.mm .
LT CABLES: 1.1 KV PVC insulated and sheathed, steel armoured Aluminimum conductor cable of the following size including cable support (For AC supply and yard lighting) , 2 core x 6 sq.mm (steel Strip armoured)
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: (Copper Control Cable , 3 core 2.5 sq.mm).
LT CABLES: 1.1 KV PVC insulated and sheathed, steel armoured Aluminimum conductor cable of the following size including cable support (For AC supply and yard lighting) , 4 core x 16 sq.mm (GI round wire armoured)
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: Aluminium Power Cables for lighting and AC Power 4 Core x 10 sq.mm (Aluminium) .
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: Aluminium Power Cables for lighting and AC Power 3.5 C x 35 Sq.mm
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: Copper Control Cable , 12 core 2.5 sq.mm
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: Copper Control Cable , 19 Core 2.5 sq.mm
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: Copper Control Cable , 4 core 2.5 sq.mm
LT CABLES: 1100 V grade, PVC insulated, PVC sheathed, steel round wire armoured, stranded control cables of the following sizes: Copper Control Cable , 7 Core 2.5 sq.mm
Mics items for Substation like: `Name plate of equipment TG, LI, LA etc. (Size 9``x5`` with white base, red border and letter written in red color)`
Mics items for Substation like: 2.5kv Megger Digital (Make-Motwane)
Mics items for Substation like: 3 cells Torch
Mics items for Substation like: 5 KV Megger Digital (Make-Motwane)
Mics items for Substation like: D-Spanner Set Taparia
Mics items for Substation like: Danger board
Mics items for Substation like: Earth chain brass 12 mtr. Length
Mics items for Substation like: Earth Megger Digital (Make-Motwane)
Mics items for Substation like: First aid Box
Mics items for Substation like: HT Hand Gloves
Mics items for Substation like: Instruction board 3’x2½’ of Flex board duly printed.
Mics items for Substation like: Insulated electrical Plier Taparia
Mics items for Substation like: Maximum and tripping display board of size 5’x3’ of mica board moulded with frame duly painted and writing.
Mics items for Substation like: Pipe wrench, 12` Taparia
Mics items for Substation like: Rubber mat 1X2MtX 12MM thick suitable for 11kV/33kV di-electic strenght
Mics items for Substation like: Shock treatment chart
Mics items for Substation like: Shut down / Break down board (Bi-lingual Hindi and English)
Mics items for Substation like: Single line diagram of size 3’x2½’ on flex board, duly printed.
Mics items for Substation like: Steel Almirah, Godrej.
Mics items for Substation like: Steel cabinet, Godrej,
Mics items for Substation like: Steel office chair, Godrej,
Mics items for Substation like: Steel office table, Godrej, (4`x2.5`)
Mics items for Substation like: Steel office table, Godrej, (5`x3`)
Mics items for Substation like: Sub-station name board (Size 3`x2` of MS sheet and MS angle 45x45x5 mm, Height 1.5 mtr. Above ground level ), duly painted
Mics items for Substation like: Sundries items Cable tie, Alu lug, Copper lug and HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, cable glands for control cable.
Mics items for Substation like: Wall Clock
PANELS , 33 KV Switchgear Panel 36kV, 26.3 KA for 3 Secs., 1000A, indoor VCB switchgear panel with required PTs, CTs, protective relays, metering equipment, auxiliary equipment, extensible (both sides) with copper busbars, complete cable termination kits as per cable sizes specified in , 33kV, 630 A Line panel (2 Nos) , 5 MVA, 33/11 kV, 630 A, Transformer Panel (3 Nos plus 1Nos spare) , 33 kV, 1250 A Bus Coupler Panel (1 Nos) , 33 KV Bus PT/Bus Riser Panel (1 Nos) , The control, metering and protection sysytem shall be compatible for performing the functions as per the electrical specifications and shall be fully compatible with sustation automation /SCADA as detailed out in the specifications of bid document.
Safety equipment : Fire Extinguishers , CO2 type for Control room and Engineers room
Safety equipment : Fire Extinguishers , Dry powder chemical type 10 kg. For 250 KVA transformer
Safety equipment : Fire Extinguishers , Safety accessories such as Rubber mat Min thickness 12mm ( IS Mark/approved make), Gloves, first aid box, shock treatment chart, display boards and tool box etc.as per specification.
Safety equipment : Fire Extinguishers , CO2 type 5 Kg for switchgear room
Safety equipment : Fire Extinguishers . Dry powder chemical type 22.5 kg. For 10/12.5 MVA transformer
Structural Steel Dewatering pump (portable type) 415 V, 1 HP as per requirement.
Structural Steel , Equipment supprt structure and cable support structure
Structural Steel: For cable tray support
Substation Automation Substation Automation and SCADA system (as per the technical specification) along with local work station with necessary hardware and software and fibre optic cabling. The system shall be complete with Numerical Relay compatible with substation automation for 33 KV and 11 KV system. The numerical relays alongwith other measuring / indicating instruments shall be part of the integrated system to be mounted on the switchgear.
Supply ,installation ,testing and commissioning of 12 KV ,3.6 MVAR, capacitor bank double star connected alongwith structure and Current Limiting reactors, NCT etc.
TRANSFORMER : 100 KVA, 2 winding,Aluminum Wound, 11/0.433kV 3ph, Dyn-11, outdoor type with cable box on HV/LV sides and complete with all accessories.
TRANSFORMER : Supply , installation , testing and commissioning of 5 MVA,33/11kV, 3 Ph, `YnYn 0 , two winding , copper wound transformers, ONAN/ ONAF with OLTC. Cable box shall be provided on both HV and LV ). The transformer shall be complete with all accessories and shall be provided with termination arrangement on HV and LV side by providing extended busbars and cable termination support.Arrangement for extension of Bus bars on Trafo HV side with 65x10mm Copper Flat with 33 KV Post Insulators as per the standard practice.
HPL Electric and Power Ltd
Shyam Indus Power Solutions Private Limited
AGARWAL TRADERS
Century Infrapower Private Limited
Ganpati Infrapower Private Limited
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid