Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹10.6 L+₹1.4 L (15.6%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹10.2 L
EMD Value
₹20,300
Closing Date
1 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
PROVN OF CERTAIN MINOR (PHASE-III) WORK AT AF STN BKT
2022_MES_548289_2
8645/BKT/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹20,300
Yes
15 Dec 2022
10 Sept 2022
3 Oct 2022
10 Sept 2022
1 Oct 2022
19 Sept 2022
Amount
M&L for flame proof point wiring with two single core FRLS PVC insulated & PVC unsheathed multi stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade drawn through concealed stove enamelled steel conduit of size 20 to 25 mm with all accessories including making good the distrubed surfaces of wall with colour washing/ distemparing the surface to match the existing and one single core PVC insulated & PVC sheathed multi stranded FRLS copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete incuding cutting chessing on wall/ flour/ ceiling etc. all as specified for one light / fan point controlled by one 5/15 Amp flame proof rotary type switch complete. Make of Cable :- Havells/ Plaza/Finolex/Polycab. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex
M&L switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed by Engr-in-Charge. Make :- Sudhir / Bajaj / Flexpro / Shyam
Supply installation and testing of flame proof metalic body Exhaust fan single phase 230 volts, 50 Hz, 16 inch sweep, 1440 RPM with louvers and shutters including civil work i. e. making of hole and complete with all fixing accessories complete all as specified and directed by Engr-in-Charge. Make :- Sudhir / Bajaj / Flexpro / Shyam
S&F Flame proof and water proof multiple entry junction box in LM6 or cast iron for distribution board 4 way when MCB to be used, AC,240 volt with complete all as directed.Make :- Sudhir / Bajaj / Flexpro / Shyam
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make :- Legrand / GE / Seimens/L&T
S&F MCB DP 32 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make :- Legrand / GE / Seimens/L&T
Supply and fixing LED Light Fitting 1x16 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. Make- Sudhir/Shyam/Bajaj/Flexpro
M & L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic rigid PVC casing caping 20/25 mm dia ISI marked and its accessories ,mounting on surface of wall/ceiling /roofs etc with suitable size PVC gang boxes for mounting piano type switch /socket/fan regulator etc including one run of 1.5 Sqmm PVC insulated mutistranded copper conductor cable green in colour for continuous earthing and connected to common earth dolly for One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed.
S&F switch socket combination outlet 2 in 1, 5 pin, 5 Amps gang box type Make: Anchor/Havells/legrand
Supply installation and testing of wall mounted Air circulator 400/450 mm sweep with high speed and aerodynamically designed metalic blades/body, heavy duty, jerk free and smooth oscillation and inbuilt regulator system chord complete all as specified and directed by EIC. Make:- Havells / Usha/Bajaj
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed. Make :- Havells / Legrand / GE / Seimens
Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
Supply and install and testing hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quailty using Non CFC refrigerant Gas ecofreindely with minimum 3 star rating and EER 3.2 of capacity 1.5 TR including outdoor unit consisting of compressor, condensor coil, candensor fan with motor and indoor unit consisting of blower, fan motor , PCB for better air flow complete all as specified and approved by EIC. Make: LG / Carrier / Samsung/Blue star /Daikin Note :- (i). Cutting holes in walls/window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate . (ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate. (iii) copper piping/drain piping is included in above rate. (iv) Iron stand for fixing out door unit in wall or rooftop is included above quoted rate. .
Supply and install and testing window type Air conditioner complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quailty using Non CFC refrigerant Gas ecofreindely with minimum 3 star rating and EER 3.2 of capacity 1.5 TR consisting of compressor, condensor coil, candensor fan with motor and indoor fan motor , PCB for better air flow complete all as specified and approved by EIC. Make: LG / Carrier / Samsung/Blue star /Daikin Note :- . (i) Electrical cable required to connect to voltage stabilizer to power supply point inclusive in above rate. (ii) drain piping is included in this rate. .
Supply and install and testing window type Air conditioner complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quailty using Non CFC refrigerant Gas ecofreindely with minimum 3 star rating and EER 3.2 of capacity 2.0 TR consisting of compressor, condensor coil, candensor fan with motor and indoor fan motor , PCB for better air flow complete all as specified and approved by EIC. Make: LG / Carrier / Samsung/Blue star /Daikin Note :- . (i) Electrical cable required to connect to voltage stabilizer to power supply point inclusive in above rate. (ii) drain pipe is included in above rate. .
Supply & Fix wall mounted digital display voltage stabilizer copper winding, for automatic voltage connection single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 3 minute of capacity 4KVA. Make : Blue Bird/ V guard/ Microtek
Supply & Fix wall mounted digital display voltage stabilizer copper winding, for automatic voltage cornnection single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity 5KVA. Make : Blue Bird/ V guard/ Microtek
Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make Havells/Anchor/Legrand
M&L in repair for submain wiring with two run of single core PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm FRLS 1100 volts grade and one run of PVC insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).Make of Cable - Havells,Plaza,Polycab.Make of Conduit - AKG,Finolex,Plaza
M&L in repair for submain wiring with two run of single core PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 10 Sqmm FRLS 1100 volts grade and one run of PVC insulated unsheathed multi stranded copper conductor cable of size 10 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).Make of Cable - Havells,Plaza,Polycab.Make of Conduit - AKG,Finolex,Plaza
S&F MCB TPN 100 Amps 415 volt rupturing cap 10 ka "C" series all as specified and directed.
M& L for cutting / opening of window any type for fixing of window AC including making frame of existing window type suitable for fixing of window AC complete packing of window with wooden ply sheet after installation of AC complete all as per required at site and directed by Engr in charge.
M&L for earthing complete with galvanised steel earth plate electrote 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level( with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washes of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I including and connecting to earthing test point block made of gun metal or phosphorus bronze size 75 x 75x 25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 50 mm bore light grade GI. protection pipe (upto 7.5 m beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6mm dia bar, watering arrangement with funned and wire mesh and 40mm bore light grade G.I watering pipe, common salt and charcoal filling as per SSR Part-I necessary excavation and earth work including Earthing pit marker/identifier of steel plate of size as directed by EIC and alongwith 1 meter long medium grade GI pipe of size 15 mm dia welded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters, in different colors complete including testing on completion complete all as specified and directed. Note:- Earthing value should be in less than permissible limit on completion of work
Supply and fix single pointed air termination rod, 12 mm dia, 300mm long all as directed.
Supply and fix aluminium strip 25x 3mm complete with saddles and fixing screws forfitting the strip.
M&L for 25 mm dia GI tubing light grade including cutting of desired lenth and suitable size of PCC block for fixing of GI tube complete all as directed
S&F Sheet metal enclosure 8 way double door distribution board when MCB to be used SPN 8 way 240 volt sheet complete all as specified and direct
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multi stranded copper conductor cable of size 2.5 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid metallic surface conduit of suitable size 20 /25 mm on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate
Supply and fixing LED highbay Light Fitting complete of capacity 120 watt in new generation energy saving environmental friendly long life integral industrial with pressure dia cast alluminium housing IP 65 protection impact resistance 240 volt 50 hz anodised alluminium reflector including all fixing accessories i.e. adjustable bracket clamp made out of flat iron of size 40x5 mm thick nut and bolts complete all as specified nd direced make- Havells/surya/Philips
M&L for manual boring underground of 100 mm dia upto 30 mtr depth below ground level in any kind of soil strata for insertion of pipe electrod 30 mtr length and coper strips etc. for bore earthing all as directed.
M& L for lowering bore Galvanised iron tubing, 50 mm bore,medium grade with all fittings accessories for protection of earth strips complete all as specified and as directed.
Material & Labour only for Bore Earthing complete for lowering of copper strips 25x4 mm thick electrode up to bottom level of borewell including filling with Chemical gell of any reputed manufacturer not less than 100 kg per earthing &connecting with earthing test point all as specified or indicated including testing on completion to get earth resistance less than 1 ohm. including 50cmx50cm size earth pit with PVC cover/CI cover complete all as directed. Note:- (i) GI pipe, copper strip will be measured and paid seperatly. (ii) The earthing result to be obtained less than permissible limit as per VCAS directive of air force for L2
Supply only copper strip 25x 4 mmmm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points.
M & L for Galvanised iron tubing, 40 mm bore,light grade with all fittings for fixed to pole/wall/ in ground including all fixing accessories complete for protection of earth strip up to the test point complete all as specified and as directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25m long hex. head screw including connecting with earthing strip complete all as specified and directed.
Supply and fix HDPE non pressure 50 mm dia pipe smooth wall non metallic flexible suitable for undrground use presssure rating not less than PN 2.5 minimum wall thickness 2.5 mm for protection of copper strip/conductor passing through the wall and from test point and upto the plinght protection complete all as directed.
H C CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .