Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹26.2 L+₹3.3 L (14.4%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.0 L+₹4.1 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not approved for opening of financial bid as the firm has uploaded the cost of tender in the name of M/s Pasaydan Electricals |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
7 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
REPAIR/ MAINTENANCE OF CAPACITOR BANK AND OTHER ALLIED WORKS AT AF STN GORKHPUR
2021_MES_474649_1
8781/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE(AF) GORAKHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹48,000
Yes
11 Nov 2021
13 Sept 2021
8 Oct 2021
13 Sept 2021
7 Oct 2021
25 Sept 2021
60 days
Amount
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 5 KVAR cylindrical type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 10 KVAR cylindrical type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 15 KVAR cylindrical type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 20 KVAR cylindrical type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 25 KVAR cylindrical type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 5 KVAR box type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 10 KVAR box type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 20 KVAR box type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of power factor capacitor, 3 Phase, 440 Volt, 50 Hz of capacity 25 KVAR box type, heavy duty complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand
S&F in replacement of detuned reactors 7%, 3 Phase, 440 Volt, 50 Hz of capacity 5KVAR suitable for fixing with the existing capacitor bank panel complete all as specified and directed. Make:L&T cat No. LTAL0705B2 or equivalent in Siemens/ Schneider/ Legrand
S&F in replacement of detuned reactors 7%, 3 Phase, 440 Volt, 50 Hz of capacity 10KVAR suitable for fixing with the existing capacitor bank panel complete all as specified and directed. Make:L&T cat No. LTAL0710B2 or equivalent in Siemens/ Schneider/ Legrand
S&F in replacement of detuned reactors 7%, 3 Phase, 440 Volt, 50 Hz of capacity 15KVAR suitable for fixing with the existing capacitor bank panel complete all as specified and directed. Make:L&T cat No. LTAL0715B2 or equivalent in Siemens/ Schneider/ Legrand
S&F in replacement of detuned reactors 7%, 3 Phase, 440 Volt, 50 Hz of capacity 20KVAR suitable for fixing with the existing capacitor bank panel complete all as specified and directed. Make:L&T cat No. LTAL0720B2 or equivalent in Siemens/ Schneider/ Legrand
S&F in replacement of detuned reactors 7%, 3 Phase, 440 Volt, 50 Hz of capacity 25KVAR suitable for fixing with the existing capacitor bank panel complete all as specified and directed. Make:L&T cat No. LTAL0725B2 or equivalent in Siemens/ Schneider/ Legrand
S&F in replacement of APFC relay, 6 stage, auto set function, having digital display complete all as specified and directed. Make:L&T cat No. CS908850000 or equivalent in Neptune/Epcos
S&F in replacement of APFC relay, 8 stage, auto set function, having digital display complete all as specified and directed. Make:L&T cat No. CS909020000 or equivalent in Neptune/Epcos
S&F in replacement of APFC relay, 12 stage, auto set function, having digital display complete all as specified and directed. Make:L&T cat No. CS909030000 or equivalent in Neptune/Epcos
S&F in replacement of capacitor duty contractor suitable for 5 KVAR complete all as specified and directed. Make: L&T cat No. CS96127 or equivalent in Epcos/Havells
S&F in replacement of capacitor duty contractor suitable for 10 KVAR complete all as specified and directed. Make: L&T cat No. CS96156 or equivalent in Epcos/Havells
S&F in replacement of capacitor duty contractor suitable for 15 KVAR complete all as specified and directed. Make: L&T cat No. CS90019 or equivalent in Epcos/Havells
S&F in replacement of capacitor duty contractor suitable for 20 KVAR complete all as specified and directed. Make: L&T cat No. CS90021 or equivalent in Epcos/Havells
S&F in replacement of capacitor duty contractor suitable for 25 KVAR complete all as specified and directed. Make: L&T cat No. CS96322 or equivalent in Epcos/Havells
S&F in replacement of capacitor duty contractor suitable for 50 KVAR complete all as specified and directed. Make: L&T cat No. CS96324 or equivalent in Epcos/Havells
S&F in replacement of power contractor suitable for 5KVAR complete all as specified and directed. Make: L&T cat No. SS91851 or equivalent in Epcos/Havells
S&F in replacement of power contractor suitable for 10KVAR complete all as specified and directed. Make: L&T cat No. SS90701 or equivalent in Epcos/Havells
S&F in replacement of HRC fuse 6-32 Amp, with fuse holder & fuse base complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand/Havells/C&S
S&F in replacement of HRC fuse 32-63 Amp, with fuse holder & fuse base complete all as specified and directed. Make:L&T/Siemens/Schneider/Legrand/Havells/C&S
S&F in replacement LED type indicating lamp rated voltage of colour red, yellow, and green suitable for existing panel complete all as specified and directed.
S&F in replacement LED type indicating lamp rated voltage of colour blue suitable for existing panel complete all as specified and directed.
S&F in replacement of Volt meter of accuracy class 1.0, single phase of size (96x96) mm square type flush mounting complete all as specified and directed. Make:L&T cat No.WL1120100000 or equivalent in AE/HPL/ Havells
S&F in replacement of Ammeter of accuracy class 1.0, single phase of size (96x96) mm square type flush mounting complete all as specified and directed. Make:L&T cat No.WL1110100000 or equivalent in AE/ HPL/ Havells
S&F in replacement of PVC cooling fan for APFC panel as per sample complete all as specified and directed.
S&F in replacement MCCB, 03 pole, 125 Amp, 50 HZ, 415 Volt, with thermal magnetic based release 100-125 Amps and rupturing capacity 18KA complete all as specified and directed. Make: L&T Cat No. CM90676OOLO or equivalent in Siemens / Schneider / Legrand
S&F in replacement MCCB, 03 pole, 200 Amp, 50 HZ, 415 Volt, with thermal magnetic based release 160-200 Amps and rupturing capacity 25KA complete all as specified and directed. Make: L&T Cat No. CM90631OONO or equivalent in Siemens / Schneider / Legrand
S&F in replacement MCCB, 03 pole, 630 Amp, 50 HZ, 415 Volt, with thermal magnetic based release 500-630 Amps and rupturing capacity 50 KA complete all as specified and directed. Make: L&T Cat No. CM9416OOT1OG or equivalent in Siemens / Schneider / Legrand
S&F in replacement of MCB, SP, 2 to 6 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. Make: L&T/Siemens/Schneider/Legrand
S&F in replacement of MCB, TP, 16 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. Make: L&T/Siemens/Schneider/Legrand
S&F in replacement of MCB, TP, 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. Make: L&T/Siemens/Schneider/Legrand
S&F in replacement of MCB, TP, 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. Make: L&T/Siemens/Schneider/Legrand
S&F in replacement of NO, NC element complete all as specified and directed. Make: L&T/Siemens/Schneider/Legrand/C&S
S&F in replacement of CT 100/5 Amp insulated class 1.0 complete all as specified and directed.
S&F in replacement of CT 200/5 Amp insulated class 1.0 complete all as specified and directed.
S&F in replacement of CT 300/5 Amp insulated class 1.0 complete all as specified and directed.
S&F in replacement of CT 400/5 Amp insulated class 1.0 complete all as specified and directed.
S&F in replacement of complete internal wiring of 40 to 200 KVAR APFC panel with 1.5sqmm HRFR multi stranded copper cable maintain proper colour coding of each circuit complete all as specified and directed.
S&F in replacement of control wiring with 1.5sqmm FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified and directed.
S&F in replacement of power wiring with 4.0sqmm FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified and directed.
S&F in replacement of power wiring with 6.0sqmm FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified and directed.
S&F in replacement of power wiring with 10 sqmm FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified and directed.
S&F in replacement of power wiring with 25 sqmm FRLSH PVC insulated industrial grade copper conductor single core unsheathed cable complete all as specified and directed.
S&F in replacement of flexible copper cable multi stranded of size 2 core, 2.5 Sqmm, 1100 volt grade including necessary tags clips etc. complete all as specified and directed.
Supply, laying and testing in replacement of 70 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, including necessary glands, lugs, nut & bolts etc. complete all as specified and directed.
Supply, laying and testing in replacement of 120 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, including necessary glands, lugs, nut & bolts etc. complete all as specified and directed.
S&F in replacement of Auxiliary contractor MXO 40 E complete all as specified and directed. Make: L&T cat No. CS94018 or equivalent in Epcos/Havells
M&L for painting of existing APFC panel of 40 KVAR to 200 KVAR internal and externally with applying two coats of synthetic enamel paint of approved shade by spray machine including preparation of existing decorated surfaces complete all as specified and directed.
Disconnecting all electric connections and taking out carefully old unserviceable APFC panel of any capacity indoor/outdoor type complete with all accessories complete all as specified and directed.
Supply, installation, commissioning and testing of APFC PANEL WITH MPP-H CAPACITOR AND MCCB AS INCOMER of Capacity 100 KVAR (in steps of 50+20+10+10+5+5 KVAR) out door type made out of mild steel CRCA sheet of 3.15 mm thick of suitable size with angle iron frame of size 40x40x6mm with canopy top, two side ventilators, front open able hinged double door shutters with locking arrangement (including lock & key), weather & vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size-04 Nos mounted on hygroscopic insulators fixed in separate bus bar chamber and separate compartment for incoming and power factor capacitors and power contactors of various capacities, all pre wired with suitable size of copper conductor cable as per their current carrying capacity including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/ platform of the APFC panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories :-
Incoming:- (a) MCCB, 3 Pole, 160 Amps, 415 volt, 25 KA - 01 No. (b) Digital ammeter composite type with CT, 0-100 Amps -01 No (c) Indicator lamp LED type set of three - 01 No (d) Digital voltmeter, 0-440 Volts -01 No (e) Digital master control relay composite type with Auto /Manual control-01 No
Outgoing:- (a) capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase, 440 V, for permissible non- linear load 15% of 100 KVAR (in steps of 50+20+10+10+5+5 KVAR) capacity- 01 Set (b) MCCB and contactor with NO and NC coils, 3 Pole, 415 volt of breaking capacity 16 KA of suitable capacity for 50 KVAR MPP H Capacitor along with indicator lamp, push button etc. All accessories should be pre wired with suitable size copper conductor cable. (c) MCB and contactor with NO and NC coils, 3 Pole, 415 volt of breaking capacity 10 KA of suitable capacity for 5 to 20 KVAR MPPH Capacitor along with indicator lamp, push button etc. All accessories should be pre wired with suitable size copper conductor cable . Note:-Any item not specified above but required for smooth functioning and testing of above panel will be provided and quoted rates deemed to be included for the provision of such item. No extra payment for the same will be made by the department.
Supply, installation, commissioning and testing of APFC PANEL WITH MPP-H CAPACITOR AND MCCB AS INCOMER of Capacity 50 KVAR (in steps of 25+10+10+5 KVAR) out door type made out of mild steel CRCA sheet of 3.15 mm thick of suitable size with angle iron frame of size 40x40x6mm with canopy top, two side ventilators, front open able hinged double door shutters with locking arrangement (including lock & key), weather & vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size-04 Nos mounted on hygroscopic insulators fixed in separate bus bar chamber and separate compartment for incoming and power factor capacitors and power contactors of various capacities, all pre wired with suitable size of copper conductor cable as per their current carrying capacity including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/ platform of the APFC panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories :-
Incoming:- (a) MCCB, 3 Pole, 100 Amps, 415 volt, 25 KA - 01 No. (b) Digital ammeter composite type with CT, 0-100 Amps -01 No (c) Indicator lamp LED type set of three - 01 No (d) Digital voltmeter , 0-440 Volts -01 No (e) Digital master control relay composite type with Auto /Manual control-01 No
Outgoing:- (a) Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase, 440 V, for permissible non- linear load 15% of 50 KVAR (in steps of 25+10+10+5 KVAR) capacity- 01 Set (b) MCCB and contactor with NO and NC coils, 3 Pole, 415 volt of breaking capacity 16 KA of suitable capacity for 25KVAR MPP H Capacitor along with indicator lamp, push button etc. All accessories should be pre wired with suitable size copper conductor cable. (c) MCB and contactor with NO and NC coils, 3 Pole, 415 volt of breaking capacity 10 KA of suitable capacity for 5 to 10 KVAR MPP H Capacitor along with indicator lamp, push button etc. All accessories should be pre wired with suitable size copper conductor cable . Note:-Any item not specified above but required for smooth functioning and testing of above panel will be provided and quoted rates deemed to be included for the provision of such item. No extra payment for the same will be made by the department.
Supply, installation, commissioning and testing of APFC PANEL WITH MPP-H CAPACITOR AND MCCB AS INCOMER of Capacity 30 KVAR (in steps of 20+5+5 KVAR) out door type made out of mild steel CRCA sheet of 3.15 mm thick of suitable size with angle iron frame of size 40x40x6mm with canopy top, two side ventilators, front open able hinged double door shutters with locking arrangement (including lock & key), weather & vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size-04 Nos mounted on hygroscopic insulators fixed in separate bus bar chamber and separate compartment for incoming and power factor capacitors and power contactors of various capacities, all pre wired with suitable size of copper conductor cable as per their current carrying capacity including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/ platform of the APFC panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories :-
Incoming:- (a) MCCB, 3 Pole, 63 Amps, 415 volt, 16 KA - 01 No. (b) Digital ammeter composite type with CT, 0-100 Amps -01 No (c) Indicator lamp LED type set of three - 01 No (d) Digital voltmeter, 0-440 Volts -01 No (e) Digital master control relay composite type with Auto /Manual control-01 No
Outgoing:- (a) Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase, 440 V, for permissible non- linear load 15% of 30 KVAR (in steps of 20+5+5 KVAR) capacity- 01 Set (b) MCCB and contactor with NO and NC coils, 3 Pole, 415 volt of breaking capacity 16 KA of suitable capacity for 20 KVAR MPP H Capacitor along with indicator lamp, push button etc. All accessories should be pre wired with suitable size copper conductor cable. (c) MCB and contactor with NO and NC coils, 3 Pole, 415 volt of breaking capacity 10 KA of suitable capacity for 5 KVAR MPP H Capacitor along with indicator lamp, push button etc. All accessories should be pre wired with suitable size copper conductor cable . Note:- Any item not specified above but required for smooth functioning and testing of above panel will be provided and quoted rates deemed to be included for the provision of such item. No extra payment for the same will be made by the department.
Hindustan Power Corporation
Pioneer Engineering works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .