Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid is competitive and reasonable among all Bid | |
| 2 | L2₹19.2 L+₹1.0 L (5.61%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹19.8 L+₹1.6 L (8.96%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹29.1 L+₹10.9 L (60.2%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | Rejected-Technical B 5 HARBANS BHAWAN MR RAM AVTAR JOSHI NANGAL RAYA SOUTH WEST DELHI DELHI 110046 | NEW DELHI | DELHI | 110046 | - | Rejected-Technical in Order being not fulfilling criteria |
Tender Value
₹17.6 L
EMD Value
₹35,200
Closing Date
26 Nov 2022, 6:00 pmClosed
CWE
CWE AF BAMRAULI ALLAHABAD
REPAIR ANNUAL MAINTENANCE OF LIFT UPS SERVO STABILIZER ISOLATION TRANSFORMER FREQUENCY CONNECTOR AIR CURTAINS GANTRY CRANES AT AF STATION GORAKHPUR
2022_MES_523043_5
87184/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GORAKHPUR
Class E Category b i and other criteria as per NIT and Tender Doc
7 documents required · 7 mandatory
₹500
GE AF GORAKHPUR
₹35,200
Yes
5 Jan 2023
2 Nov 2022
3 Dec 2022
2 Nov 2022
26 Nov 2022
10 Nov 2022
2 Nov 2022 - 5 Nov 2022
Amount
Material and labour for annual maintenance of lift installed at SRE building at Air Force Station by providing monthly preventive service and attending breakdown call on working days working hours. Make of lift - Johnson Note:- (i) Repair works shall be carried out by OEM only.
Annual maintenance of lift installed at MPR (274 SU) building at Air Force Station by providng monthly preventive serevice and attending breakdown calls on working days working hours. Make of lift - Johnson Note:- (i) Repair works shall be carried out by OEM only.
Annual maintenance of lift installed at DWR building at Air Force Station by providing monthly preventive service and attending breakdown calls on working days working hours. Make of lift - OTIS Note:- (i) Repair works shall be carried out by OEM only. Note: Consumable items are not covered under this contract.
Annual maintenance of Fire Alarm System for the locations at DWR , SRE, GCA, Derin III Station armoury, 274 SU, 12 AFH CT Scan, Jaguaar Simulator, NGCCM and MPU buildings complete all as specified and directed with following components:- (i) Fire Alarm detector - 232 Nos (ii) Fire alarm Hooter / Sprinkler - 25 Nos (iii) Fire Alarm indicator light - 102 Nos (iv) Fire Alarm activation panel - 28 Nos (v) Main control panel - 13 Nos
Supply and fixing in replacement of ARD battery of capacity 12 volt 18 AH complete asll as specified and directed (For 274 SU and SRE lift)
Supply and fixing in replacement of charger batttery of capacity 12 volt 2.5 AH Complete all as specified and directed.
Supply and fixing in replacement of ARD battery of Capacity 12 volt 7/7.2 AH Complete all as specified and directed (For 274 SU and SRE lift)
Supply and fixing in repair of metallic body exhaust fan 300 mm sweep 230 Volt AC for fixing in machine room for proper ventilation incl electric connections and taking down old unsv complete all as specified and directed by Engr-In-Charge. MaKe:- Havells cat part No Ventil Air DS/CG/Bajaj
Supply and fixing in replacement of power door contact female complete all as specified .
Supply and fixing in replacement of metal roller 'V' assembly complete all as specified.
Supply and fixing in replacement of nylon roller 'U' assembly complete all as specified.
Supply and fixing in repair of high efficient recess mounted LED downlighter 15 W with pressure die cast aluminium heat sink & PC diffuser in white powder coated finish with integarted driver incl electric connections and taking down old unsv complete all as specified and directed by Engr-In-Charge. Make:- Bajaj cat part No BZSLO 15W WHPRO or equilvaqnt of Havells/CG
Supply and fixing Variable Voltage and Variable frequency (VVVF) drive of capacity 15 KW, 415 Volts AC for VVVF system including taking out old unserviceable drive . Make:- OTIS/JOHNSON
Supply , installation, testing and commissiioning Automatic Rescure Device (ERD 10) control complete unit with all accessories including maintenance free batteries (EBD Mono 12 V, 12 AH) 04 Nos suitable for 4/6/8/10 passenger lift complete with including taking down unserviceable one all as specified and as directed Make:- OTIS/JOHNSON
Supply and fix in repair of car operating panel consists of microstroke luminous push button for all floors, door open, door close, fan, light, emergency light, alarm, stop and auto attendance key, emergency light , 9 segment floor position indicator for automatic lift with SS front face matching the existing floor cutout after dismantling the existing unit complete all as specified and directed. Make:- OTIS/JOHNSON.
Material and Labour for connecting of UPS (digital/analog type), 3 phase, 415 volts, AC, 50 Hz, 2 KVA and detecting the internal faults of following parts/ assembly etc of any make and type and repair/replace the same defective parts of same type/capacity as OEM design and testing onload complete with including taking down unserviceable one all as required and as directed:- Make of Existing UPS : Uniline (a) Intelligent slot (b) SNMP card (c) Transformer (d) Auxillary circuit (e) Communication port/EPO Port (f) Support time (g) Suitable operating (h) LCD/LED display information (j) Buzzer alarm status (k) Bypass switch (l) Identification Menu Note:- Old unserviceable parts/ assembly will be measured and paid seperately.
All as per item No. 16 but capacity of UPS (digital/analog type), 3 phase, 415 volts, AC, 50 Hz, 5 KVA Make of Existing UPS : Aplab
All as per item No. 16 but capacity of UPS (digital/analog type), 3 phase, 415 volts, AC, 50 Hz, 10 KVA Make of Existing UPS : Uniline
All as per item No. 16 but capacity of UPS (digital/analog type), 3 phase, 415 volts, AC, 50 Hz, 15 KVA Make of Existing UPS : Aplab
All as per item No. 16 but capacity of UPS (digital/analog type), 3 phase, 415 volts, AC, 50 Hz, 20 KVA Make of Existing UPS : Aplab
Disconnecting/taking out old unserviceable batteries of capacity 12 Volts, upto 50 AH from existing UPS (digital/analog type) of capacity 3 phase, 415 volts 3 to 200 KVA all as directed.
Disconnecting/taking out old unserviceable batteries of capacity 12 Volts, above 50 AH to 100 AH from existing UPS (digital/analog type) of capacity 3 phase, 415 volts 3 to 200 KVA all as directed.
Disconnecting/taking out old unserviceable batteries of capacity 12 Volts, above 100 AH to 150 AH from existing UPS (digital/analog type) of capacity 3 phase, 415 volts 3 to 200 KVA all as directed.
Supply, install and connecting of maintenance free, dry cell battery of capacity 12 volts up to 50 AH as reqd at site all as directed. Make :- Exide
Supply, install and connecting of maintenance free, dry cell battery of capacity 12 volts above 50 AH to 100 AH as reqd at site all as directed. Make- Exide
Supply, install and connecting of maintenance free, dry ell battery of capacity of 12 Volts above 100 AH to 150 AH as reqd at site all as directed. Make:- Exide
Supply only intellgent slot of UPS capacity 2 KVA 3 phase as required at site Make of Existing UPS : Uniline
Supply only intellgent slot of UPS capacity above 10 KVA 3 phase as required at site Make of Existing UPS : Uniline
Supply only intellgent slot of UPS capacity above 15 KVA 3 phase as required at site Make of Existing UPS : Aplab
Supply only intellgent slot of UPS capacity above 20 KVA 3 phase as required at site Make of Existing UPS : Aplab
Supply only SNMP card of UPS capacity 2 KVA 3 phase as reqd at site. Make of Existing UPS : Uniline
Supply only SNMP card of UPS capacity 5 KVA 3 phase as reqd at site. Make of Existing UPS : Aplab
Supply only SNMP card of UPS capacity 10 KVA 3 phase as reqd at site. Make of Existing UPS : Uniline
Supply only SNMP card of UPS capacity 15 KVA 3 phase as reqd at site. Make of Existing UPS : Aplab
Supply only SNMP card of UPS capacity 20 KVA 3 phase as reqd at site. Make of Existing UPS : Aplab
Supply only Transformer of UPS capacity 2 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only Transformer of UPS capacity 10 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only Transformer of UPS capacity 15 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only Transformer of UPS capacity 20 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only Auxillary circuit of UPS capacity 10 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only Auxillary circuit of UPS capacity 15 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only Auxillary circuit of UPS capacity 20 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Suppy only communication port/ EPO port of UPS capacity 5 KVA 3 phase as reqd at site. Make of Existing UPS : Aplab
Suppy only communication port/ EPO port of UPS capacity 10 KVA 3 phase as reqd at site. Make of Existing UPS : Uniline
Suppy only communication port/ EPO port of UPS capacity 15 KVA 3 phase as reqd at site. Make of Existing UPS : Aplab
Supply support time of UPS capacity 2 KVA 3 phase as required at site Make of Existing UPS : Uniline
Supply support time of UPS capacity 5 KVA 3 phase as required at site Make of Existing UPS : Aplab
Supply support time of UPS capacity 10 KVA 3 phase as required at site Make of Existing UPS : Uniline
Supply support time of UPS capacity 15 KVA 3 phase as required at site Make of Existing UPS : Aplab
Supply only Suitable operating software package of UPS capacity 2 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only Suitable operating software package of UPS capacity 5 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only Suitable operating software package of UPS capacity 10 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only Suitable operating software package of UPS capacity 15 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only Suitable operating software package of UPS capacity 20 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only LCD/LED display system of UPS capacity 2 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only LCD/LED display system of UPS capacity 10 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only LCD/LED display system of UPS capacity 15 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only LCD/LED display system of UPS capacity 20 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only Buzzer alarm system of UPS capacity 2 KVA 3 phase as required at site Make of Existing UPS : Uniline
Supply only Buzzer alarm system of UPS capacity 5 KVA 3 phase as required at site Make of Existing UPS : Aplab
Supply only Buzzer alarm system of UPS capacity 10 KVA 3 phase as required at site Make of Existing UPS : Aplab
Supply only Buzzer alarm system of UPS capacity 15 KVA 3 phase as required at site Make of Existing UPS : Uniline
Supply only Bypass switch of UPS capacity 10 KVA 3 phase as required at site. Make of Existing UPS : Uniline
Supply only Bypass switch of UPS capacity 20 KVA 3 phase as required at site. Make of Existing UPS : Aplab
Supply only electrolytic surge capacitor 3300 Mfd, 500 Volt DC for UPS capacity 20 KVA 3 phase as required at site.
Disconnecting of all electrical connection and opening of Automatic Servo voltage stabilizer/Isolation Transformer, Three phase, balanced load 300-480 volts and derive volts 400-440 volts, + 1.5 Volts, air/ oil cooled of capacity 10 KVA/15 KVA/ 20 KVA/ 25 KVA/ 40 KVA/ 75/150/200 KVA of any make/design, opening and cleaning of transofmer and repairing the faults, re-assembling after replacement of unserviceable/defective, worn out parts with new parts of same make/type/capacity reassembling , commissioning and testing in satisfactory manner and testing on load complete. Note:- Old unserviceable parts/ assembly will be measured and paid seperately
Supply only control relay suitable for 10 to 40 KVA voltage stablizer
Supply only Control relay suitable for 75 KVA voltage stablizer
Supply only Control relay suitable for 150 to 200 KVA voltage stablizer/Isolation Transformer
Supply only Voltmeter 0-500 volts suitable for 75 to 200 KVA voltage stabilizer/ Isolation Transformer.
Supply only Automatic printed circuit board (electronic control circuit) suitable for 10/15/20/25/25/40/75 KVA servo voltage stabilizer
Supply only Automatic printed circuit board (electronic control circuit) suitable for 150KVA to 200 KVA servo voltage stabilizer/Isolation Transformer.
Supply only Time relay circuit upto 200 KVA with all accessories.
Supply only Transformer main copper wound upto 5 kg suitable for 5 to 20 KVA, 3 phase voltage stabilizer withcopper winding.
Supply only Transformer main copper wound upto 15 Kg Suitable for 40 & 75 KVA, 3 phase voltage stabilizer with copper winding.
Supply only Dimmer Circuit of Servo voltage stabilizer of capacity 10 to 75 KVA, suitable for stabilizers/Isolation Transformers all directed.
Supply only Dimmer Circuit of Servo voltage stabilizer of capacity 150 & 200 KVA, suitable for Stabilizers/ Isolation Transformers all directed.
Material and Labour for repair of Servo Motor (synchronous) of Servo type voltage stabilizer, three phase 415 volt, AC of capacity 40/75 KVA.
Material and Labour for toping up of new transformer oil conforming to IS grade with suitable di-electric strenght for isolation transformer/servo voltage stabilizer of capacity upto 200 KVA complete all as specified and as directed. Make:- Gulf Castrol/HP/IOC/BP/Servo/Power Oil
M/S DEEKSHA CONSTRUCTION
RVRconstructon
M/s Comfort Air Conditioning and Refrigeration Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .