Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.8 LAccepted-Finance | 1 | Accepted-Finance L1 |
Tender Value
₹3.5 L
EMD Value
₹6,950
Closing Date
1 Mar 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-III/RZ/NZ
EEE-III/RZ/NZ
Improvement of Park lights in D-14 park Sector-3 Rohini and other Parks of Sector-3 and 4 Rohini in ward no-53 under Rohini zone
2022_NDMC_107199_1
EEE-III/RZ/NZ/TC/2021-22/21.1
Open Tender
Electrical Works
Item Rate
120 days
EEE-III/RZ/NZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹6,950
3 Mar 2022
23 Feb 2022
2 Mar 2022
23 Feb 2022
1 Mar 2022
23 Feb 2022
180 days
Amount
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.up to 35 sq. mm
Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required.
Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
S/D 2x2.5Sq.mm PVC insulated S/C Copper conductor, wire in existing pole PVC conduit as required.
Supply of 2x 6 mm2 XLPE insulated and PVC sheathed unarmoured cable of 1.1KV grade conforming to IS 7098 part-1 as required.
Supply of 2x10mm2 XLPE insulated and PVC sheathed armoured cable of 1.1KV grade conforming to IS 7098 part-1 as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Providing and laying cement concrete in kerbs ,steps and the like at or near ground level excluding the cost of centering ,shuttering and finishing 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)
P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x140x95mm (NS) complete with suitable arrangment for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with 2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
SITC of 20W LED Street Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage =20 watt +/- 5% (d) Luminaire Efficacy>=100 Lm/w (e) Power Factor>=0.95 (f) Protection Class- IP-66
SITC of 60W LED Street Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage =60 watt +/- 5% (d) Luminaire Efficacy>=100 Lm/w (e) Power Factor>=0.95 (f) Protection Class- IP-66
S/F 40mm dia GI pipe medium class along with the pole/wall for cable protection i/c painting etc as required.
Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 250 mm long 40 mm dia galvanized pipe with tightening bolts complete as required.
Foundation of pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 3 metre and upto 4.5 metre
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .