Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC AS PER BOQ | |
| 2 | L2₹43.2 L+₹10.2 L (30.9%)Rejected-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-AOC AS PER BOQ | |
| 3 | L3₹35.1 L+₹2.1 L (6.48%)Rejected-AOC | L3 | Rejected-AOC AS PER BOQ |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
25 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road
GE Army Dhar Road Udhampur
EXECUTION OF CERTAIN EM SANCTIONED WORKS AT SAMNABANJ DHANSAL AND CERTAIN OTHER LOCATIONS UNDER GE ARMY DHAR ROAD
2021_MES_421215_3
8066/NIT-72/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Samabanj RC peak Dhansal and Dhar Road
Please refer tender documents
5 documents required · 5 mandatory
₹500
GE Army Dhar Road Udhampur
₹62,000
Yes
25 Jul 2021
27 Apr 2021
27 May 2021
27 Apr 2021
25 May 2021
11 May 2021
28 Apr 2021 - 4 May 2021
60 days
Amount
Taking down old unserviceable motor pump 12.5 WHP inclding taking down old PCC foundation any size and deposit to Dhar Road MES store yard from samnabanj pump house stage I and stage II all as directed
Taking down old unserviceable pumping set Deisel engine 30 WHP including taking down old PCC foundation and deposit to Dhar Road MES store yard from Samnabaj pump house stage I and stage II all as directed
Taking down old unserviceable motor pump 40 WHP inclding taking down old PCC foundation any size and deposit to Jindrag MES store yard from Dhansal Jahajjar Nala all as directed
Supply , installation , testing and commissioning of certrifugal pump multistage flow rate 120 Ltr/Min, not less than 300 Mtr headrated speed 2930 RPM, Bronze Impeller, water Liquid type , Efficiency not less than 50% alogwith electric driven motor 3 phase 415 volts, 50 HZ, 20 HP /15.00 KW including base plate, coupling, starter star delta and foundation with PCC suitable size as per manufacutrer recommendation drawing alngwith foundation bolts/nuts etc all as directed alogwith following specifiction given below :- Operating conditions :- (i) Discharge Flow rated - 120.00 Ltr/Min (ii) Differential Head - Not less than 300 Mtr, (iii) Electric supply - 415 Volt, AC, 50 HZ Performance :- (i) Speed- 2930 RPM (ii) Efficiency - not less than 50% (iii) Impeller :- Bronze (iv) Self priming Driven and Power Data :- (i) Electric driven 415 volts, 50 Hz, 20 HP/15KW motor (ii) star delta starter for 20 HP motor Note :- (i) Rate of transportation upto stage I and II at samnabanj including PCC foundation as per manufacturer's recommendation are deemed in the same item rate. Make of pump : Kirloskar/KSB Motor Make of motor :- Crompton/Cummins/L&T/Kirloskar
Supply , installation , testing and commissioning of certrifugal pump multistage flow rate 12 Ltr/sec, not less than 200 Mtr head rated speed 2900 RPM, Bronze Impeller, water Liquid type , Efficiency not less than 64% alogwith electric driven motor 3 phase 415 volts, 50 HZ,45KW / 60 HP including base plate, coupling, starter star delta and foundation with PCC suitable size as per manufacutrer recommendation drawing alngwith foundation bolts/nuts etc all as directed alogwith following specifiction given below :- Operating conditions :- (i) Discharge Flow rated -- 12.00 Ltr/Sec (ii) Differential Head :- Not less than 200 Mtr, (iii) Electric supply -- 415 Volt, AC, 50 HZ Performance :- (i) Speed-- 2900 RPM, (ii) Efficiency - : not less than 64% , (iii) Impeller :- Bronze (iv) Self priming Driven and Power Data :- (i) Electric driven 415 volts, 50 Hz, 60 HP/45KW motor (ii) star delta starter for 60 HP motor Note :- (i) Rate of transportation upto Jahajjar Nala pump house are included in this item. PCC foundation rates as per manufacturer's recommendation are deemed in the same item . Make of pump : Kirloskar/KSB Motor Make :- Crompton/Cummins/L&T/Kirloskar
Supply , installation , testing and commissioning of Diesel engine driven 32 BHP air cooled alongwith speed increasing gear box with certrifugal pump, self started including 12 volt Battery and pump of multistage , flow rate 120 Ltr/Min, not less than 280 Mtr head rated speed 1500 RPM, Bronze Impeller, water Liquid type , Efficiency not less than 50% including base plate, coupling and foundation with PCC suitable size as per manufacutrer recommendation drawing and design alngwith foundation bolts/nuts etc all as directed alogwith following specifiction given below :- Operating conditions :- (i) Discharge Flow rated - 120.00 Ltr/Min (ii) Differential Head - Not less than 280 Mtr (iii) Diesel Engine driven 32 BHP alongwith air cooled engine with speed increasing gear box with 12 volt battery self started Performance (i) Speed- 1500 RPM (ii) Efficiency - not less than 50% (iii) Impeller - Bronze Driven and Power Data :- (i) Diesel engine driven ,1500 RPM, 32 BHP air cooled as per designed by manufacurer's Note :- (i) Rate of transportation upto stage I and II at samnabanj including PCC foundation as per manufacturer's recommendation are deemed in the same item rate. Make of pump : Kirloskar/KSB Motor Make :- Deisel engine : Cummins/Kirloskar/Stamfort/Mahindra
Taking down old unserviceable LT panel alongwith all accessories all as directed including dismentalling of foundation
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32x6mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
Supply and installed cooling split Air Conditioner electric driven single phase of capacity 2.0 TR 3 star BEE split AC incl mounting accessories along with stand for out door unit Make-Blue Star/Panasonic/Voltas equivalent.
Voltage Stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilised at 230 Volts with accuracy of + 2.5 % and of capacity of 5 KVA.
M&L for concealed sub main wiring of copper conductor wire with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments in PVC rigid conduit not less than 25mm, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLS PVC insulated incl PVC conduit shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .Make-Havells/Finolex/Polycab/Grandley
Supply & Fixing DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete including concealed in wall all as specified and directed. Make- Schneider (Electric)/Legrand/L & T .
Supply and fixing MCB, single pole 'C' series having braking capacity 10 KA, 6 to 32 Amp, 240 volts, complete all as specified & directed. Make : Legrand/Schneider/Havells
Supply & Fixing MCB SPN having braking capacity 10 KA 35-60 Amp, 240 Volt 'C' Curve complete all as specified and directed. Make : Legrand/Schneider/Havells
Supply and laying 2 core 16 sqmm1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall.PVC shethead in service connection suspended by insulating hangers not more than01 Mtr apart incl 4mm dia suspension GI wire and 14SWG GI wire for holding hangers insulator fixed as in repair complete all as specified and directed (Note:- for the complete purpose measurment one 16 sqmm 2 core cable and GI wire 4 sqmm dia shall be considered as one running meter Make:- Finolex/Havells/Paragon.
Supply and fix AC Box with sheet metal enclouser with earth plug and socket including MCB 20 A
S&F RO Water Purifier of capacity 50 LPH, industrial type complete including connection and testing. Make : Havells or equivalent).
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 ltrs
S&F Voltage stabilizer 1 KVA for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 170 to 250 V with output stabilized at 230 V with accuracy of 2.5+- 2.5% .
Point wiring for Power point contolled by one 15 Amp switch independent with PVC insulated and unsheathed multistranded FRLSH copper conductor single core 2.5 Sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping(ISI Mark) with all accessories including providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet(HYLUM BRAND) top cover or PVC switch board of required size as per site requirement alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 2.5 Sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and as directed. Make of cable : Finolex/ Havells/ Grandlay
M&L for switch socket combination 5Amp/16 Amp 5 in 1 flush type.
Cutting of existing GI pipe and insert tee for making connection for 15 mm dia GI pipe incl GI fitting.
S&F 15mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc with all fitting including connection with existing pipe line complete all as specified and directed.
S&F 20mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc with all fitting including connection with existing pipe line complete all as specified and directed.
S&F 25mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc with all fitting including connection with existing pipe line complete all as specified and directed.
S&F Gun metal globe or gate valves high pressure with iron wheel head, screwed both ends for iron/ GI pipe or for unions of 15 mm bore , complete all as specified and directed.
S&F Gun metal globe or gate valves high pressure with iron wheel head, screwed both ends for iron/ GI pipe or for unions of 20 mm bore , complete all as specified and directed.
S&F Gun metal globe or gate valves high pressure with iron wheel head, screwed both ends for iron/ GI pipe or for unions of 25 mm bore , complete all as specified and directed.
Supply and fixing union joint with rubber seal 20 mm dia all as specified and directed
Supply and fixing union joint with rubber seal 25 mm dia all as specified and directed
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4.00mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1,precast RCC cover in 1:2:4 reinforced with expanded metal ,with suitable handle,excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-1 2009,connected to earthing testing point including taking out existinf UNSV earthing complete as specified and testing on completion complete as specified and directed. Note :- The units rates including the cost of excavation and earth work in any type of soil, charcole and salt in alternate layers, 25 mm GI pipe(light grade) for watering 25 mm GI protection pipe(light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40 mm thick RCC cover for pit etc and no extra payment will be made.
Supply and laying testing cable XLPE insulated, screened PVC bedded galvanised stell strip or wire electric power cable heavy duty 1100 volts grade with standard aluminium conductor with size 6 sqmm 2 core.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M&L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 50 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
M/S A K ENGINEERS & CO.
M/S Builders Indias
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .