| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC Deposited performance security amount | |
| 2 | L2₹11.3 L+₹10,319.33 (0.93%)Rejected-Finance 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | L2 | Rejected-Finance Rejected as NOT being L1 bidder. | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | M/S UNNATI ELECTRICAL WORKS L1 | ARJUN ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 8.0 metre and upto 11.0 metre | 3 | Each | 5,782.32 ₹17,346.96 Lowest | 5,835.86 ₹17,507.58 |
| 2.00 | Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required. | 2 | Each | 2,025 ₹4,050 Lowest | 2,043.75 ₹4,087.5 |
| 3.00 | Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required [Part-A (8span x 40m x 5wire system =1600)] = 1600m x 0.214kg/m = 342.4Kg] + [Part-B (3span x 40m x 5wire system =600)] = 600m x 0.214kg/m = 128.4Kg] + [Part-C (5span x 40m x 4wire system =800)] = 800m x 0.214kg/m = 171.2Kg] + [Part-D (9span x 40m x 2wire system =720)] = 720m x 0.214kg/m = 154.08Kg]; Total= 796.08 Kg | 796.08 | kg | 156.6 ₹1,24,666.13 Lowest | 158.05 ₹1,25,820.44 |
| 4.00 | Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. | 25 | set | 1,125.36 ₹28,134 Lowest | 1,135.78 ₹28,394.5 |
| 5.00 | Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with and finished paint as required. | 24 | set | 676.08 ₹16,225.92 Lowest | 682.34 ₹16,376.16 |
| 6.00 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.. | 15 | Each | 4,568.4 ₹68,526 Lowest | 4,610.7 ₹69,160.5 |
| 7.00 | Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required | 45 | set | 243 ₹10,935 Lowest | 245.25 ₹11,036.25 |
| 8.00 | Supplying and erection of 100 mm x 110 mm shackle insulator with G.I. bolts, nuts and straps etc. as required. | 108 | set | 183.6 ₹19,828.8 Lowest | 185.3 ₹20,012.4 |
| 9.00 | Dismantling of overhead lines comprising of copper/aluminium overhead conductor, G.I. wire cross arms, insulators etc. as required. | 796.08 | kg | 69.12 ₹55,025.05 Lowest | 69.76 ₹55,534.54 |
| 10.00 | Supplying and erection of 100 mm x 80 mm pin insulator complete with G.I. spindle and nuts etc. as required. | 89 | set | 128.52 ₹11,438.28 Lowest | 129.71 ₹11,544.19 |
Tender Value
₹10.3 L
EMD Value
₹13,000
Closing Date
4 Oct 2025, 11:00 amClosed
SO(EnM), BnK
GM Office, BnK Area, Bermo, Bokaro, Jharkhand
Repair and maintenance of (A) 440V OH line from transit camp/Rest House to GM office, (B)440V from cut point near GM Tanki to GM Office and 220V Street lighting line from GM Office to Kargali Gate, (C ) 440V LT power line extending from the transform
2025_CCL_344481_6
SO(EnM)/e-tender/25-26/11
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GM Unit
As per NIT
2 documents required · 2 mandatory
₹13,000
20 Jan 2026
23 Sept 2025
6 Oct 2025
23 Sept 2025
4 Oct 2025
24 Sept 2025
23 Sept 2025 - 30 Sept 2025
Amount
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 8.0 metre and upto 11.0 metre
Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required [Part-A (8span x 40m x 5wire system =1600)] = 1600m x 0.214kg/m = 342.4Kg] + [Part-B (3span x 40m x 5wire system =600)] = 600m x 0.214kg/m = 128.4Kg] + [Part-C (5span x 40m x 4wire system =800)] = 800m x 0.214kg/m = 171.2Kg] + [Part-D (9span x 40m x 2wire system =720)] = 720m x 0.214kg/m = 154.08Kg]; Total= 796.08 Kg
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with and finished paint as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required..
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required
Supplying and erection of 100 mm x 110 mm shackle insulator with G.I. bolts, nuts and straps etc. as required.
Dismantling of overhead lines comprising of copper/aluminium overhead conductor, G.I. wire cross arms, insulators etc. as required.
Supplying and erection of 100 mm x 80 mm pin insulator complete with G.I. spindle and nuts etc. as required.
G.I. wire (8 SWG) (+) Erection of G.I. wire no. 8 SWG including binding etc. as required. [Part-A (6 span x 3 x 40m = 720 Mtr x 0.192kg/m = 138.24 Kg)] + [Part-B (4 span x 3 x 40m = 480 Mtr x 0.192kg/m = 92.16 Kg)] + [Part-C (6 span x 3 x 40m = 720 Mtr x 0.192kg/m = 138.24 Kg)] + [Part-D (3 span x 3 x 40m = 360 Mtr x 0.192kg/m = 69.12 Kg)]
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) (0.60x0.60x0.90x04=1.3)
Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel work. 7 Sq.m per Pole
Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supply and laying of 2 core aluminium cable of size 16 sqmm or above.
Supply of Clamps , bolts, nuts, etc (For pole clamping)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.(150 mm X 75 mm X 60 mm deep)
Supply and laying of 2 core copeer wire of size 4 sqmm or above.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supply and laying of PVC pipe of minimum 50 mm size suitable for covering of cable of size 16 sqmm.
Fitting and fixing of LED steet light
Dismantling of LED light from Pole
Providing and fixing 200 Amp capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing 100 Amp capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing of offload Change over 200A-AC 20 (Side handle) 415V AC, 50Hz
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground .(Above 35 sq. mm and upto 95 sq. mm)
Supply and providing of 11KV (400Amp) grade GOAB switch. (Horizontal type, heavy duty) male contact- 1.5mm, female contact-1.25 x 2
Fitting of Horizontal type GOAB (Heavy duty)
Supply, providing and fixing of 11 kV Post Insulator for Horn Gap Switch
Supply and providing of Copper Flat (50 mm x 6 mm) of length 1.5. feet for making Horn of shape L
Reparing of 3.3KV, 400A, GOAB switch by replacing isolator assembly including fixed and moving contract.
Total impact of GST for the purpose of CTC
ARJUN ENTERPRISES (BID ID -1187899)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .