Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.6 L+₹1.0 L (11.8%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹9.9 L+₹1.3 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹11.0 L+₹2.4 L (28.2%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹11.5 L+₹3.0 L (34.7%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Jan 2020, 6:00 pmClosed
Garrison Engineer (East)
Stanley Road, Teliyarganj, Allahabad
REPAIR/REPLACEMENT OF INTERNAL WIRING, ELECTRICAL FITTINGS AND FIXTURES TO MD JCOS/ ORS AND MD OFFICERS ACCN AND REPAIR OF HEATING APPLIANCES AT VARANASI UNDER GE (EAST) ALLAHABAD.
2019_MES_303299_1
8365/E8
Open Tender
Civil Works
Item Rate
270 days
Varanasi
As Per NIT
6 documents required · 6 mandatory
₹500
Yes
GE (East) Allahabad
₹30,000
Yes
20 Feb 2020
10 Dec 2019
14 Jan 2020
10 Dec 2019
8 Jan 2020
24 Dec 2019
Amount
Taking down carefully point wiring of any type and any description / caping or concealed [light point, fan point or socket point] including removal of battens, pipes, plug sockets, switches, shades, ceiling roses, light fittings etc complete and making good disturbed surface to match the exisitng complete all as specified & directed.
Taking down carefully sub main wiring of any nos of wire with wire on wooden batten or surface conduit or concealed conduits complete all as specified & directed.
Taking down main switches, distribution boards and cut outs of any capacity along with the exisitng boards and removing the same from site and making good disturbed surface or portion of walls complete all as specified & directed.
Material & Labour Point wiring with PVC Insulated 1.5 Sqmm multi-stranded copper conductor FRLS cable 1100 Volts grade drawn into and including PVC Casing & Capping medium grade not less than 20mm wide (ISI marked) including all fitting and fixings accessories including 1.25 mm thick factory fabricated sunken pressed steel terminal boxes duly painted with one coat of anti-corrosive paint outside and two coats of aluminium paint inside with and including 2.8 mm thick top cover hylam brand plastic laminated white sheet cover for mounting switches, sockets, fan regulators fixed with steel screws with cup wahsers and including PVC Insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire complete all as specified and directed for following poit wirings:---
(a) One light / fan point controlled by one switch
(b) One light point controlled by two, two way switch
(c) One buzzer or bell point controlled by one switch
(d) One socket point 3 pin switch socket out let 5 Amp controlled by one switch on same board.
(e) One socket point 3 pin switch socket out let 5 Amp controlled by one switch on Independent board.
Description same all as per item No. 04 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm with 1.5 Sqmm multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp Independent board complete all as specified & directed.
Supply & Fixing switch piano flush type single pole one way 5 Amps flush type complete all as spicified & directed.
Supply & Fixing switch piano flush type single pole two way 5 Amps flush type complete all as spicified & directed.
Supply & Fixing bell push 5 Amps flush type complete all as spicified & directed.
Supply & Fixing socket out let 3 pin 5 Amps complete all as spicified & directed.
Supply & Fixing Switch socket combination 2 in 1, 3 pin / 5 Pin, 5Amp & 15 Amps flush type of complete all as specified & directed.
Supply & Fixing Ceiling rose surface bakelite type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.
Supply & Fixing lamp holder insulated body with back plate suitable for batten fittings complete all as specified & directed.
Supply & Fixing electronic fan regulator flush type suitable for ceiling fan complete all as specified & directed.
Supply & Fixing electric ding dong bell AC operated on 230 Volts complete all as specified & directed.
Material & Labour for concealed Sub main wiring with two single core PVC Insulated cable of size 10 Sqmm multi-stranded copper conductor FRLS cables drawing into and including PVC conduit, medium grade not less than 32 mm dia with all conduit accessories and one run of 6 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including cutting chases in brick wall and making good disturbed surface complete all as specified & directed. Note : - Two run of 10 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
Material & Labour for concealed Sub main wiring with two single core PVC Insulated cable of size 6 Sqmm multi-stranded copper conductor FRLS cables drawing into and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including cutting chases in brick wall and making good disturbed surface complete all as specified & directed. Note : - Two run of 6 Sqmm & one run of 4 Sqmm cable shall be measured as one unit run.
Material & Labour for concealed Sub main wiring with two single core PVC Insulated cable of size 4 Sqmm multi-stranded copper conductor FRLS cables drawing into and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 2.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including cutting chases in brick wall and making good disturbed surface complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 2.5 Sqmm cable shall be measured as one unit run.
Supply & Fixing 1x18 watt four feet long decorative box type [Ultra slim] linear LED [6000K] batten light fittings with co-extruded polycorbonate body, envoirement friendly, energy efficient pre-wired and making necessary electric connection from ceiling rose with 23/.0076 flexible three core copper wire 1.2 RM long & fixed to wall firmly complete all as specified & directed. Make : Crompton Trim Lenia Cat Part No. LCTL-18-CDL / Havell's ELite Pride 18 W / Bajaj BCLSBAL 18W CW LED or model make in Philips.
Supply & Fixing in repair 18-20 watt four feet long high efficiency retrofit tube rod suitable for fixing in existing fittings of 36 watt complete all as specified & directed. Make : Philips / Havell's / Crompton / Bajaj
Supply & Fixing in repair 9 watt retrofit lamp B-22 type with holder base with polycarbonate body complete fitted in lamp or batten holder complete all as specified & directed.
Supply & Fixing ultra slim edgelit LED down lighter 7 watt high efficiency glare free powder coated aluminium housing hanging on ceiling with steel chain complete all as specified & directed. Make : Philips / Havell's / Crompton / Bajaj
Supply & Fixing aesthetically desigend edge lite LED linear mirror light fittings 1x9 watt with high output PMMA diffuser for glare free light decorative, envoirement friendly, energy efficient pre-wired and making necessary electric connection from ceiling rose with 23/.0076 flexible three core copper wire 1.2 RM long & fixed to wall firmly complete all as specified & directed. Make : Havells Cat Part No. LHEXAPRP7PN1W009 / Crompton / Bajaj or Philips.
Supply & Fixing 10 watt LED bulk head light fittings having 600 Lumen enclosed in polycarbonate body, weather proof with co-extruded poly carbonate body, envoirement friendly, energy efficient pre-wired and making necessary electric connection from ceiling rose with 23/.0076 flexible three core copper wire & fixed to wall firmly complete all as specified & directed. Make : Havell's Model "Endura Rugby" Cat Part No. RUGBYNEONFT10WLED760SSYMBOPC / Bajaj Model Wee Plus CAt Part No. BIWP10WLEDLCL-07-CDL / Crompton or Philips.
Supply & Fixing in repair building security / street LED light fitting 15 watt IP-65 protection pressure die-cast aluminium body, heat resistant glass, including driver and making necessary electric connection with 2.5 Sqmm twin core copper wire 1.5 long complete fixed in existing GI pipe bracket fixed to pole or on walls complete all as specified & directed. Make : C&S Cat Part No. LTESS15WLED / Crompton / Philips or Havells as approved by GE.
Supply & Fixing sheet metal enclosure MCB DB's double door [Acrylic], triple pole and neutral, 415 volts, 4 way with 200 Amp rated bus bars, 10 KA breaking capacity with blanking plate wherever required and IP-43 degree protection making necessary incomming & outgoing electric connections complete all as specified & directed. Make : Legrand / Schneider / ABB
Supply & Fixing sheet metal enclosure MCB DB's double door [Acrylic], double pole and neutral, 240 volts, 12 way with 200 Amp rated bus bars, 10 KA breaking capacity with blanking plate wherever required and IP-43 degree protection making necessary incomming & outgoing electric connections complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing sheet metal enclosure MCB DB's double door [Acrylic], double pole and neutral, 240 volts, 8 way with 200 Amp rated bus bars, 10 KA breaking capacity with blanking plate wherever required and IP-43 degree protection making necessary incomming & outgoing electric connections complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing sheet metal enclosure MCB DB's double door [Acrylic], double pole and neutral, 240 volts, 6 way with 200 Amp rated bus bars, 10 KA breaking capacity with blanking plate wherever required and IP-43 degree protection making necessary incomming & outgoing electric connections complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing MCB TPN 415 Volt, 63 Amps,16KA breaking capacity complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing MCB Single Pole & Neutral 240 Volt, 32-40-63 Amps, 'B' Series 10KA breaking capacity complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing MCB Single Pole 240 Volt, 6-32 Amps, 'B' Series 10KA breaking capacity complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with & including one number MCB SP 20/25 Amps complete all as specified & directed. Make : Legrand / Schneider / ABB / Indo Asian
Supply & Fixing in repair modular fan regulator 5 step 120 watt 2 module ISI marked complete all as spicified & directed.
Supply & Fixing moduler dummy / blanking plate 1-2 module complete all as spicified & directed.
Taking down / out damaged existing louver shutter of exhaust fan and supply & fixing factory fabricated lover shutter suitable for 230-300 mm sweep with MS frame and galvanised tinned sheet of thickness 1 mm and fixing with anchor bolt or fastner grouting in walls including two coats painting with symthetic enamel paint complete all as specified & directed.
Taking down / out damaged existing louver shutter of exhaust fan and supply & fixing factory fabricated lover shutter suitable for 380-450 mm sweep with MS frame and galvanised tinned sheet of thickness 1 mm and fixing with anchor bolt or fastner grouting in walls including two coats painting with symthetic enamel paint complete all as specified & directed.
Taking down existing geyser of any capacity any type after disconnecting of all electric & water supply connection & removing the geyser to E&M store yard for opening and dismantling the complete geyser cleaning all the serviceable parts thoroughly including descaling the geyser completely replacing the defective / wornout parts / material, reassembling the geyser after testing for proper functioning, including transporting to original location where re-fixing the same in position reconnecting the geyser with electric & water supply line and testing complete all as directed by Engineer-in-Charge. NOTES : Unit rate quoted shall be deemed to include any minor items i.e. nut, bolts, screws, lugs etc.
Material & Labour for taking out / down existing geyser of any capacity any type after cleaning of elements thoroughly including descaling the geyser completely, reassembling the geyser after testing for proper functioning re-fixing of geyser in same or other location reconnecting the geyser with electric & water supply line complete all as directed by Engineer-in-Charge.
Supply & Fixing in repair at site (without taking down Geyser) heating element threaded / screwed / Square or triangular or any type 1500 watt 230 Volt ISI marked of suitable make to adjust or as directed.
Supply & Fixing in repair at site (without taking down Geyser) heating element threaded / screwed / Square or triangular or any type 2000 watt 230 Volt ISI marked of suitable make to adjust or as directed.
Supply & Fixing in repair at site (without taking down Geyser) ceramic / porcelain heating element or any type 2000 watt 230 Volt adjust or as directed.
Supply & Fixing in repair thermostat auto cut at site (without taking down Geyser) suitable for 25 or 50 Litre capacity of geyser, range 20 degree to 80 degree ISI marked complete all as specified & directed.
Supply & Fixing in repair Inner tank made of copper metal 0.6 mm thick suitable for 25 Litre capacity Geyser complete all as specified & directed. Make : Bajaj or Recold
Supply & Fixing in repair Inner tank made of copper metal 0.6 mm thick suitable for 50 Litre capacity Geyser complete all as specified & directed. Make : Bajaj or Recold
Supply & Fixing in repair syphon assembly suitable for 25 Litre capacity Geyser complete all as directed.
Supply & Fixing in repair syphon assembly suitable for 50 Litre capacity Geyser complete all as directed.
Supply & Fixing in repair aparture plate assembly suitable for 25 Litre capacity Geyser complete all as directed.
Supply & Fixing in repair aparture plate assembly suitable for 50 Litre capacity Geyser complete all as directed.
Supply & Fixing in repair non-return valve 15 mm dia of cast copper alloy complete all as directed.
Supply & Fixing in repair presure release valve 15 mm dia complete all as directed.
Supply & Fixing in repair drain plug complete all as directed.
Supply & Fixing in repair at site (without taking down Geyser) indicator lamp assembly with bulb suitable for geysers round or square type of approved make and quality as approved.
Supply & fixing glass wool in layers in geysers including taking out old damaged glass wool complete all as specified & directed.
Supply & fixing in repair PTMT float valve suitable for 15 mm dia galvanised iron pipe complete all as specified & directed.
Supply & Fixing in repair at site (without taking down Geyser) PVC connection cotton braided heavy duty with brass union / coupling of length 450 mm with rubber washer suitable for 15mm dia pipe for hot or cold water connection.
Material & Labour for one coat painting of Geyser at site by spray gun painting (without taking down Geyser) of 25 Litre capacity with synthetic enamel paint including prepaeration of old surface and re-writing or marking MES Number complete all as specified & directed.
Material & Labour for one coat painting of Geyser at site by spray gun painting (without taking down Geyser) of 50 Litre capacity with synthetic enamel paint including prepaeration of old surface and re-writing or marking MES Number complete all as specified & directed.
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm dai # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note :- If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt.
M/S PANDEY TRADERS
M/s A.KUMAR ELECTRICALS
M/S UJJAWAL ENTERPRISES
M/s multienterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .