Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC NO 46 SOUTH STREET KEEZHAKASAKUDY KOTTUCHERRY KARAIKAL 609 609 | KARAIKAL | PUDUCHERRY | 609609 | L1 | Accepted-AOC Work order issued | |
| 2 | L2₹15.2 L+₹73,565 (5.08%)Rejected-Finance NO 11 1 NSC BOSE STREET KARAIKAL 609 602 | KARAIKAL | PUDUCHERRY | 609602 | L2 | Rejected-Finance Unsuccessful tenderer | |
| 3 | L3₹15.8 L+₹1.3 L (9.32%)Rejected-Finance NO 15 III CROSS THIRUVALLUVAR NAGAR PATCHOOR KARAIKAL 606 602 | 606602 | L3 | Rejected-Finance Unsuccessful tenderer | |
| 4 | L4₹18.5 L+₹4.0 L (27.5%)Rejected-Finance NO 3 5 MAIN ROAD SERUMAVILANGAI NEDUNGADU KARAIKAL 609 603 | KARAIKAL | PUDUCHERRY | 609603 | L4 | Rejected-Finance Unsuccessful tenderer | |
| 5 | Not Admitted-Fee/PreQual/Technical NO 4 PLAZ NORTH STREET KARAIKAL 609602 | KARAIKAL | PUDUCHERRY | 609602 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹17.7 L
EMD Value
₹35,349
Closing Date
26 Jul 2023, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,
Buildings and Roads Division, Public Works Department, Karaikal
Retrofitting work, face lifting and Construction of Galvalume sheet roof shed at First floor of the Administrative Block at Thanthai Periyar Government Higher Secondary School, Karaikal.
2023_PWDC3_13180_1
08-03/PW/BRK/2023-24
Open Tender
Civil Works
Item Rate
90 days
Karaikal
Please refer Tender documents.
6 documents required · 6 mandatory
₹525
₹35,349
14 Sept 2023
18 Jul 2023
27 Jul 2023
18 Jul 2023
26 Jul 2023
18 Jul 2023
Amount
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting, propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level - Thermo - Mechanically treated bars (TISCON / VIZAG/ /SAIL / JSW) Fe - 415 or more
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete - hot finished seamless type tubes
Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
Providing and fixing on wall face unplasticised -PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
Providing and fixing on wall face unplasticised -PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion-bend 87.5 degree-110mm bend
Providing and fixing on wall face unplasticised -PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion-shoe (plain)-110mm shoe
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x 50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm
Providing and fixing colour coated galvalume sheet of 550 M.P.A. yield of AZ 150 strength formed as per patterned steel rib profile with the depth of 31 mm pitch of 250 mm and overall width of 1060 mm and thickness 0.5mm with required J or C hook bolts and nuts 8mm dia G.S. paint and working etc., complete excluding the cost of purlin , rafter and truss etc.,
15mm cement plaster on the rough side of single or half brick wall of mix - 1:4 (1cement : 4 fine sand)
Providing and applying ready mixed wall putty (JK/Birla) of 2mm thickness over plastered surface to prepare the surface even and smooth complete
White washing with lime to give an even shade - new work (three or more coats)
Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer
Wall painting with plastic emulsion paint - Royal of approved brand and manufacture to give an even shade - two or more coats on new work
Wall painting with plastic emulsion paint - Premium of approved brand and manufacture to give an even shade - two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work
Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40mm dia .M.S.tube 1.5m centre to centre , horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S.tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as approved. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. (Note: This item to be used for maintenance work judicically, necessary deduction for scaffolding in the existing item to be done.)
Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
Chipping of unsound /weak concrete material from slabs, beams, columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete - 50mm average thickness
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete- 25mm average thickness
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and complete in all respect - Epoxy bonding adhesive having coverage 2.20 sqm /kg of approved make
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by wt.of cement used) asper specifications. Note: Measurement and Payment : The Pre-meaurement of thick -ness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube crusing strength at the end of 28 days to be not less than 30 N / Sqmm) - 25 mm average thickness in two layers
Providing leak proof centering and shuttering using 25mm thick plywood for damage slab / beam to carrying out micro concreting work including ceiling the gaps if any with renderoc plugging compound and removal of form work
Laying of non shrink free flow micro concrete renderoc RG or equivalent in the proportion 1:1 (One renderoc Rg: one graded stone aggregate of 12.5mm and below through the drilled holes till the voids and damaged area are completely filled and set to an average thickness of 50mm as directed by the Engineer in Charge.
KANNIAPPAN
RAVICHANDRAN.M.J
AMALANATHAN A
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .