Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | ₹12.6 L Quoted ₹14.8 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹19.1 LRejected-Finance H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | ₹19.1 L | L2 | Rejected-Finance Being L2 bidder |
| Sl No | Description | Qty | Unit | YASHU CONTRACTORS L1 | virendra constructions L2 |
|---|---|---|---|---|---|
| 1.00 | Attending complaints of no water / leakage of water by removing float valve, water meter, stop cock etc or GI/composite tubing of size 15 mm to 20 mm bore upto 0.3 mtr length including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed. | 610 | Each Job | 100 ₹61,000 | 100 ₹61,000 |
| 2.00 | Description all as per item No 1.00 above but of size 25 mm bore | 230 | Each Job | 100 ₹23,000 | 100 ₹23,000 |
| 3.00 | Description all as per item No 1.00 above but of size 40 mm bore | 80 | Each Job | 150 ₹12,000 | 150 ₹12,000 |
| 4.00 | Description all as per item No 1.00 above but of size 50 mm bore | 70 | Each Job | 200 ₹14,000 | 150 ₹10,500 |
| 5.00 | Description all as per item No 1.00 above but of size 80 mm bore | 30 | Each Job | 250 ₹7,500 | 300 ₹9,000 |
| 6.00 | Description all as per item No 1.00 above but of size 100 mm bore
NOTE for Ser item No (01 to 6) : -
(i) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (ii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (iii) Minimum two Skilled pipe fitters and two Semi skilled pipe fitter for helper should be report at water suply service centre daily before 08.00 Hrs and will give feed back daily against that day complaints to JE at 17;00 Hrs. (iv) Complaints given to contractor shall be rectified within 24 hrs. (v) A penality of Rs 500/- per complaint will be charged for not attending the complaints and completed within 48 hours. (vi) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required. (vii) Excavation and earth work deemed to be quoted rate. (viii) Repeated Complaints should not be paid separately and if it will not rectified within during period given by JE, concern amount will be deducted from already paid amount against repeated complaints. | 10 | Each Job | 400 ₹4,000 | 400 ₹4,000 |
| 7.00 | Attending leakage complaints of sluice valve 80 mm to 150 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed. | 25 | Each Job | 150 ₹3,750 | 200 ₹5,000 |
| 8.00 | Attending leakage complaints of sluice valve 200 mm to 250 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed. | 10 | Each Job | 200 ₹2,000 | 300 ₹3,000 |
| 9.00 | Attending leakage complaints of sluice valve 300 mm to 400 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed. | 5 | Each Job | 200 ₹1,000 | 500 ₹2,500 |
| 10.00 | Attending leakage complaints of CI/DI pipe lines 80 to 100 mm bore using lead wool,rope, caucking, rubber gasket joints for DI in situ complete all as specified and directed. | 50 | Each Job | 300 ₹15,000 | 500 ₹25,000 |
Updated dates
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
9 Jan 2026, 6:00 pmClosed
GE (W)
GE (W) HISAR HISAR MIL STN
CA NO GE(W)/HSR-39/2025-26 REPAIR/REPLACEMENT OF UNSERVICEABLE CI/DI/GI PIPE LINES AND CONNECTED ALLIED WORKS OF HISAR MIL STN UNDER GE (W) HISAR
2025_MES_744245_1
CA NO. GE(W)/HSR-39/2025-26
Open Tender
Civil Works
270 days
HISAR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (W) HISAR
₹46,000
GE (W) HISAR
4 Feb 2026
12 Dec 2025
12 Jan 2026
12 Dec 2025
9 Jan 2026
26 Dec 2025
13 Dec 2025 - 20 Dec 2025
20 Dec 2025
Amount
Attending complaints of no water / leakage of water by removing float valve, water meter, stop cock etc or GI/composite tubing of size 15 mm to 20 mm bore upto 0.3 mtr length including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed.
Description all as per item No 1.00 above but of size 25 mm bore
Description all as per item No 1.00 above but of size 40 mm bore
Description all as per item No 1.00 above but of size 50 mm bore
Description all as per item No 1.00 above but of size 80 mm bore
Description all as per item No 1.00 above but of size 100 mm bore NOTE for Ser item No (01 to 6) : - (i) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (ii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (iii) Minimum two Skilled pipe fitters and two Semi skilled pipe fitter for helper should be report at water suply service centre daily before 08.00 Hrs and will give feed back daily against that day complaints to JE at 17;00 Hrs. (iv) Complaints given to contractor shall be rectified within 24 hrs. (v) A penality of Rs 500/- per complaint will be charged for not attending the complaints and completed within 48 hours. (vi) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required. (vii) Excavation and earth work deemed to be quoted rate. (viii) Repeated Complaints should not be paid separately and if it will not rectified within during period given by JE, concern amount will be deducted from already paid amount against repeated complaints.
Attending leakage complaints of sluice valve 80 mm to 150 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed.
Attending leakage complaints of sluice valve 200 mm to 250 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed.
Attending leakage complaints of sluice valve 300 mm to 400 mm bore by opening /removing gland plate and taking out water from water pit , providing gland packings and refitting including replacing new one instead of worn out bolts,nuts,washers as required complete all as specified and directed.
Attending leakage complaints of CI/DI pipe lines 80 to 100 mm bore using lead wool,rope, caucking, rubber gasket joints for DI in situ complete all as specified and directed.
Description all as per item No 10.00 above but size of 150 to 200 mm mm bore.
Description all as per item No 10.00 above but size of 250 to 400 mm bore. NOTE for Ser item No (07 to 12) : - (i) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (ii) Excavation and earth work deemed to be in the quoted rate. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (iv) Minimum One Skilled pipe fitters and One Semi skilled pipe fitter for helper should be made available during all week days. (v) Complaints given to contractor shall be rectified within 24 hrs. (vi) A penality of Rs 1000/- per complaint will be charged for not attending the complaints and completed within 48 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required. (viii) Repeated Complaints should not be paid separately and if it will not rectified within during period given by JE, concern amount will be deducted from already paid amount against repeated complaints.
Taking up or down steel tubing and connections 15 mm bore including cleaning for relaying / re-fixing or removal from site complete all as specified and directed.
Description all as per item No 13.00 above but of size 20 mm bore
Description all as per item No 13.00 above but of size 25 mm bore
Description all as per item No 13.00 above but of size 32 mm bore
Description all as per item No 13.00 above but of size 40 mm bore
Description all as per item No 13.00 above but of size 50 mm bore
Description all as per item No 13.00 above but of size 80 mm bore
Supply and fixing Steel water tubes, medium grade, ISI marked, galvanised, 15mm bore with all fittings, Tee, Socket, Union, flange and Socket laid in trenches/ on walls complete all as specified and directed.
Description all as per item No 20.00 above but of size 20 mm bore
Description all as per item No 20.00 above but of size 25 mm bore
Description all as per item No 20.00 above but of size 32 mm bore
Description all as per item No 20.00 above but of size 40 mm bore
Description all as per item No 20.00 above but of size 50 mm bore
Description all as per item No 20.00 above but of size 80 mm bore
Laying only old steel water tubes, any grade, galvanised, 15 mm bore with all new fittings, laid in trenches/on walls complete all as specified and directed.
Description all as per item No 27.00 above but of size 20 mm bore
Description all as per item No 27.00 above but of size 25 mm bore
Description all as per item No 27.00 above but of size 32 mm bore
Description all as per item No 27.00 above but of size 40 mm bore
Description all as per item No 27.00 above but of size 50 mm bore
Description all as per item No 27.00 above but of size 80 mm bore
Taking up cast iron/Ductile Iron water mains (including all fittings) 100mm bore, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
Description all as per item No 34.00 above but of size 150 mm bore
Description all as per item No 34.00 above but of size 200 mm bore
Description all as per item No 34.00 above but of size 250 mm bore
Description all as per item No 34.00 above but of size 300 mm bore
Description all as per item No 34.00 above but of size 400 mm bore
Supply and fixing Cast iron/Ductile Iron pipes 100mm bore with spigot and socket ends, centrifugally cast, class LA, in any length, laid in trenches complete all as specified and directed.
Description all as per item No 40.00 above but of size 150 mm bore
Description all as per item No 40.00 above but of size 200 mm bore
Description all as per item No 40.00 above but of size 250 mm bore
Description all as per item No 40.00 above but of size 300 mm bore
Description all as per item No 40.00 above but of size 400 mm bore
Laying only in trenches old cast iron/Ductile Iron pipes with spigot and socket ends centrifugally cast in any length, 100mm bore complete all as specified and directed.
Description all as per item No 46.00 above but of size 150 mm bore
Description all as per item No 46.00 above but of size 200 mm bore
Description all as per item No 46.00 above but of size 250 mm bore
Description all as per item No 46.00 above but of size 300 mm bore
Description all as per item No 46.00 above but of size 400 mm bore
Cutting of 80 mm to 300 mm bore existing CI /DI Pipe for taking up of damaged / leakage portion or for insertion of branch T etc complete all as specified and directed. (Both cut shall be measured as one Job)
M&L for Cast iron/DI fittings viz bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, ‘Y’ junction, double branch, cross (all sockets or socket & spigot) collars, caps and plugs for spigot socketed pipes 200 mm to 300mm bore complete all as specified and directed.
Burning out lead joint in position for 80 mm to 150mm bore pipes and fittings complete all as specified and directed. Note for Ser item No 54 to 55 :- New lead joint will be paid separately under relevant item here-in-after.
Description all as per item No 54.00 above but of size 200mm to 300mm bore
M & L for Run lead joint for cast iron spigot and socket pipes and fitting of 80mm to 150mm bore complete all as specified and directed.
Description all as per item No 56.00 above but of size 200mm to 300mm bore
Supply and fixing in repair Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 15 mm bore fixed complete all as specified and directed.
Description all as per item No 58.00 above but of size 20 mm bore
Description all as per item No 58.00 above but of size 25 mm bore
Description all as per item No 58.00 above but of size 32 mm bore
Description all as per item No 58.00 above but of size 40 mm bore
Description all as per item No 58.00 above but of size 50 mm bore
Repair to non return valve 80mm to 150mm bore by opening nuts, bolts and washer and replacing flap/gasket with new flap/gasket, refixing the nuts, bolts and washers etc. New Nuts, bolts and washers if required including in this rarte only complete all as specified and directed.
Repair to non return valve 200mm to 250mm bore by opening nuts, bolts and washer and replacing flap/gasket with new flap/gasket, refixing the nuts, bolts and washers etc. New Nuts, bolts and washers if required including in this rarte only complete all as specified and directed.
Repair to non return valve 300 mm to 400mm bore by opening nuts, bolts and washer and replacing flap/gasket with new flap/gasket, refixing the nuts, bolts and washers etc. New Nuts, bolts and washers if required including in this rarte only complete all as specified and directed.
M&L for flanged joint with rubber or fibre board gasket of CI/DI pipes, sluice valves, non return valves etc of 80mm to 300mm bore fixed in repair/replacement complete all as specified and directed.
Supply and fixing Sluice valves class P N 1.6 cast iron body with forged steel spindle, non rising type, with cast iron wheel head, both end flanged, ISI marked, 300 mm bore including neoprene rubber gasket, nuts, bolts, washers, etc fixed in repairs complete all as specified and directed.
Description all as per item No 68.00 above here-in-beofe but 250mm bore.
Description all as per item No 68.00 above here-in-beofe but 200 bore.
Description all as per item No 68.00 above here-in-beofe but 150mm bore.
Description all as per item No 68.00 above here-in-beofe but 100mm bore.
Description all as per item No 68.00 above here-in-beofe but 80mm bore.
S&F Non-return valves class P N 1.6 cast iron body, ISI marked, heavy duty both ends flanged suitable for 80 mm bore pipe fixed in repairs complete all as specified and directed.
Description all as per item No 74.00 above here-in-before but of size 100 mm.
Description all as per item No 74.00 above here-in-before but of size 150 mm.
M&L SS spindle with check nut of sluice valve 80 mm bore as per existing pattern, fixed in repairs/replacement including nuts, bolts & washers complete all as specified and directed.
Description all as per item No 77.00 above but for sluice valve 100 mm bore
Description all as per item No 77.00 above but for sluice valve 150 mm bore
Description all as per item No 77.00 above but for sluice valve 200mm bore
Description all as per item No 77.00 abovebut for sluice valve 250mm bore
Description all as per item No 77.00 above but for sluice valve 300mm bore
Excavating in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5mt in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mt in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5mtr in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5mrt wide and not exceeding 1.5mt in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5mt in depth for shafts, cesspits, manholes, pier holes, etc and getting out in mud complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50mt and depositing where directed at a level not exceeding 1.5mt above the starting point complete all as specified and directed.
S&F in replacement of any size of sluice valve operating rod made of GI pipe heavy duty 20 mm bore, 1.5 mtr to 4 mtr long as per ground requirement duly fixed on sluice valve at one end welded with sluice valve cap , at other end with handle complete all as specified and directed.
S&F MS clamp of any size including drilling holes complete all as specified and directed.
M&L construction of brick masonry valve pit of size 1500 mm X 1500 mm X 1250 mm (internal dimensions of chamber) depth to be reckoned from the top of PCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCC foundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified and directed.
Description same as per srl item No. 90.00 herein before but internal size of valve pit 1200 mm X 1200mm X 1200 mm
Description same as per srl item No. 90.00 herein before but internal size of valve pit 900 mm X 900mm X 900 mm
Material & Labour for making good surface with same existing surface of disturbed surface during laying various sizes of DI pipe line such as drainages (Brick Masonary and plastering), foot paths (Inter locking/Chequered Tiles/PCC hard standing),Tank crossing roads (Stone Pitch), Fencing (Angle Iron stand Pole/RCC Poles/Chain link/Barbered Coil), electric cables (Cable Joints with required existing cable size and qty as per site reqmt), Sewer lines (Manholes chambers, NP2 pipes with required existing pipe size and qty as per site reqmt) and water pipe lines (Valve pit chambers, CI/DI/GI pipes with required existing pipe size and qty as per site reqmt) complete all as specified and directed.
virendra constructions (BID ID -3514339)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.34 MB
TenderDocuments39.pdf
Tender Documents • 12.87 MB
BOQ_833367.xls
BOQ • 1.34 MB
Download all tender documents and submit your bid