Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.2 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹15.0 L+₹1.8 L (13.3%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹15.6 L+₹2.4 L (17.8%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L-3 | Rejected-Finance L-3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE (AF) Bhisiana
HQ CWE (AF) Bhisiana
REPAIR/ MAINTENANCE OF HT INFRASTRUCTURE IN DOMESTIC AND TECHNICAL AREA AT AF STATION BARNALA UNDER GE (AF) HALWARA
2023_MES_605296_1
CWE(BHI)/HAL-24/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Halwara
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Halwara
₹40,000
Yes
16 Aug 2023
23 Jun 2023
21 Jul 2023
23 Jun 2023
19 Jul 2023
7 Jul 2023
Amount
Taking down the existing defective HT UG cable of any size in trenches / pipes / pole for attanding the repair, jointing materials, refixing / relaying back in trenches, fixed on poles complete all as specified and directed . Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit.
Supplying, laying, jointing, testing and commissioning of HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part - II with amendment, size 120 Sqmm, 3 core , laid in trenches /pipes /ducts /along poles/ walls/ equipment etc. complete all as specified and directed. Note: (i) Excavation and earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be made and paid separately. (ii) Excavation & earth work shall be paid once if cable is being laid on same location. (iii) No straight through joint shall be permitted in less than single drum length.
Supplying, laying, jointing, testing and commissioning of HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 95 Sqmm, 3 core , laid in trenches /pipes /ducts /along poles/ walls/ equipment etc. complete all as specified and directed.
Excavation in trenches not exc 1.5mtr wide and not exc 1.5mtr in depth for laying of cable etc not exc 10 sqm on plan and getting out, in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each complete all as specified and as directed.
Removal of surplus soil to a distance not exc 500 mtrs & depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and as directed.
Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover , Class HV type-I, size 300mmx180mmx40mm for protection of cable complete all as specified and as directed.
Re-laying only old but serviceable precast concrete cover, class HV type, flat size 300 mm X 180 mm X 40 mm in trenches for cable protection with cable cover retrieved from srl No 1 here in before complete all as specified and directed.
Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.60m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge.
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 3 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 3 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections to make it functional including tesing on existing load complete all as specified and as directed.
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 2 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 2 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections to make it functional including tesing on existing load complete all as specified and as directed.
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 6 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 6 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections to make it functional including tesing on existing load complete all as specified and as directed. Notes for Item No 11 to 13: 1. Spare parts shall be measured and paid for separately under respective items as supply only in replacement . 2. Parts replaced shall be identical to those specified by original manufacture. 3. Parts of minor nature such as nuts, bolts, screws & washers required at site are deemed to be included in the cost quoted.
Supply only self powered protection Relay of RMU,Horizontal type complete all as specified and directed Make : C&S cat part No. CSPR-V6-H-1-P2-H-M or equivalent of make as specified.
Supply only resin cast ring core protection Current Transformer of ratio 1KV/√3/110V/√3 Cl- 0.5, 100VA of RMU complete all as specified and as directed
Supply only replacement resin cast ring core metering current transformer of ratio 100-50/1-1A Class 0.5 and 5P10 burden 15VA of RMU complete all as specified and as directed.
Supply only digital multifunction meter for 11 KV RMU complete all as specified and as directed. Make : Rishab Model Rish master 3428 or equivalent of make as specified.
Supply only shunt tripping coil as existing of RMU complete all as specified and as directed.
Supply only set consisting of 3 HV-Back up fuse link for three phase indoor type conforming to IEC 60282-1 suitable for fixing in 11 KV RMUs (for load upto 250 KVA) of current rating (capacity) 10Amp having short circuit rating not less than 63 KA complete all as specified and directed.
Supply and filling SF-6 gas in safe ring /safe plus by SF-6 gas bottle by removing front cover and on screw manometer and reduction valve and maintain the pressure 14 bar absolute complete all as specified and directed.
Servicing of HT VCB panel, detection of defective components, replacement of worn out parts and servicing/cleaning of mechanical components after drawout of VCB trolly and testing for smooth operation manual/remote after calibration of relay through OEM or Auth dealer of VCB/Test wing of UPPCl and resetting & generation of testing report by the primary injection set for 11KV VCB for OC/FE, parameter of relay setting for healthy system, complete all as specified and directed by Engr-in-Charge. Note :- (i) Replacement of wornout minor parts shall deemed to be included in quoted rate. (ii) Major parts shall be measured and paid separately. (iii)Testing and calibration shall be done from OEM or their Authorised dealer representative.
Supply only Spring charging Motor of VCB 110-230Volt AC supply for the opening and closing of contacts, make & specifications as existing at site complete all as specified and directed.
Supply only indicator lamp as per existing colour code for 11 KV VCB of make & specifications as existing at site complete all as specified and directed.
Supply only alarm make MP series alarm annuciators or equivalent as approved by GE complete all as specified and directed.
Supply only Voltmeter ranging from 0-12 KV, digital type, 96mm x 96mm class 0.5, PTR 11000/rt3/110/rt3 complete all as specified and directed.
Supply only Phase over current and earth fault relay REF601 ABB Make or in equivalent as approved by GE complete all as specified and directed.
Supply and fixing in replacement of power pack with battery backup minimum time of backup 110V AC/30V DC and connected to HT PT secondary circuit including testing for triping complete all as specified and directed.
Material and labour in replacement for jointing and testing cable jointing kit for 11 KV grade cable indoor type end termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
Material and labour in replacement for jointing and testing cable jointing kit for 11 KV grade cable indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 240 sqmm complete all as specified and as directed.
Material and labour in replacement for jointing and testing cable jointing kit for 11 KV grade cable Outdoor type end termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
Material and labour in replacement for jointing and testing cable jointing kit for 11 KV grade cable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
Material and labour in replacement for jointing and testing cable jointing kit for 11 KV grade cable straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 240 sqmm complete all as specified and as directed.
Supply and fixing galvanised iron strip 25x4 mm with porcelin saddles and fixing screws for roof conductors and down conductors above ground after taking down/out strip as existing at site complete all as specified and as directed. Note :- Strip should be brazed/welded at each joint.
Taking down old busbar chamber, Material and labour for fabrication, Supplying, install and testing & Commisioning of out door type CPRI approved factory made HT 11 KV feeder pillar box of size not less than 156x80x117 cm with top cover projection around made with 3.15 mm CRCA sheet weather proof, vermin proof with double door, handle with locking arrengement, powder coated including PVC insulator copper bus bar 03 Nos per size of 130cmx5cmx0.5 cm & mounted on HT 11 KV insulator 9 Nos (three Nos per bus bar) insulator should be mounted on MS sheet with thickness 3mm made in shape including weather proof resistive coated paint the feeder pillar box should be mounted on MS frame made with MS angle of size 60cmx60cmx6cm and grounting on ground with PCC (1:3:6) as foundation of MS angles including PCC and Earth work for fixing of busbar angle iron legs on ground or any surfacecomplete all as specified and directed.
Dismantling old unserviceable gang operated air breaker switch from two pole / four pole structure, and Supply and fixing of gang operated air breaker switch ,triple pole, mechanically operated , mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 400 amps,out door type conforming to IS specifications, HT 11 KV , triple pole with fixed contacts of phosphorous , bronze and a set of drop out HT fuse assembly , fuse carrier fitting , 9 insulator type mounted on MS channel operating rod with pad lock arrangements complete all as specified and as directed.
Supply and fixing in replacement lightning arresters gapless metal oxide type consisting of Zinc Oxide varistors, FRP core and silicon housing with all fitting transmission class discharge capacity 65 kilo amps 11000 volts complete all as specified and as directed.
Supply only of tinned copper drop out fuse wire, solid conductor of size 8-26 SWG, complete all as specified and directed .
Supply only of self adhesive electrical insulation tape of size 1.8cm x 6.50 mtr x 0.125mm of colour as approved complete all as specified and as directed. .
Material and labour for sprading of stone aggregate of nominal size not more than 63mm from the bay/yard manually without damaging any equipments, cable or parts of the Grid bays, spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface all as specified and directed
Material and labour for providing reinforced cement concrete type B-1, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining terminal posts, struts etc. for fencing, average sectional area not exc 250 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops etc complete all as specified and directed.
Tracing out fault in 11KV U/G cable with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. Note: (i). Joint kit to be measured and paid separately. (ii) Neccessary earth work to be included . (iii) All other necessary arrangements suitable for locating the faults is deemed to be included in the quoted rate. (iv) T & P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account )
Opening of all electrical connections HT/LT from the bushings/terminal box of the unserviceable distribution transformer , indoor/outdoor type from existing position/location or 4 pole structure, of any make & specifications,of capacity upto 500 KVA & transporting the transformer to authorised dealer workshop for repairs with opening of top cover including conservator, dehyderating breather and allied items, inspecting the same to assess the repairs required, making the joint inventories of unserviceable items/parts to carryout the repair works, cleaning , greasing and overhauling complete including taking out & replacement of unserviceable /worm out parts with new parts, taking out core/winding coils out from tank and replacement of burnt coils as per existing, fixing parts by draining out of transformer oil to make the transformer serviceable, refilling the transformer oil after cleaning of tank and repairing/dehyderation of oil to get the di-electric strength of oil upto 45 KV(rms), re-assembling after repairing and transporting the repaired transformer back to the work site and placing in original position, connecting all eletrical/meachnical connections, commissioning of transformer on load after testing complete all as specified & as directed. Notes:- (i) The LT/HT coils if rewinded and transformer oil if required for topping, shall be measured and paid separetely.
Material and labour for taking out burnt copper from coils of transformer ,of any capacity,cleaning all the limbs, rewinding with supper enamelled copper wire of same weight, gauge etc of HT/LT winding with suitable gauge by calculatging mumber of turns as per voltage of transformer, varnishing and drying by vaccum impregnating, replacing insulating material, nuts,bolt etc including testing as per latest IS, compete all as specified and as directed.
Supply and fixing of transformer porcelain bushing outdoor/indoor type suitable for 11 KV grade complete of transformer capacity upto 500 KVA, 11/0.415 KV transformer complete all as specified and as directed. (Transformer bushings shall be compitable model with make as per existing transformer model)
Supply and fixing of transformer porcelain bushing outdoor/indoor type suitable for 1100 volts grade complete of transformer capacity upto 500KVA , 11/0.415 KV transformer complete all as specified and as directed. (Transformer bushings shall be compatiable model with make as per existing transformer model)
Supply only brass stud with accessories suitable for HT 11000 volts grade insulator with con & rubber washer, double Brass nuts & brass washer at both end of stud for Tr cap up to 160-500 KVA complete all as specified and directed.
Supply only brass stud suitable for LT 1100 volts grade insulator with con & rubber washer, double brass nuts & brass washer at both end of stud for Tr cap 160-500 KVA complete all as specified and directed.
Supply & fixing of adhesive computerised cut sticker on 2mm thick aluminium sheet, blue back ground with white letter, sticker size 60 Cm x 90 Cm long, letter size as suitable for display on substation wall for complete transformers rating and other details of all transformers installed inside substation. (Note: Name plate board shall be fixed to substation bldg wall with suitable fastener bolt)
Material and labour for replacement of breather assembly of transparent plastic body with top and bottom portion pressed with metalic cover, filled with silica jel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for dehydration of transformer oil with mobile transformer oil filtration plant at site with all accessaries connected to transformer and carrying out filteration of oil for desired dielectric strength i.e. not less than 40 KV at 2.5mm gap. Note :- 1. Test certificates shall be submitted before and after filteration for electric strength.
Supply, filling and poring transformer oil ISI marked in sealed containers for voltage stablizers and transformer of dielectric strength not less than 50 KV to comply IS-335 of 1993 including recording results complete all as specified and directed. Note:- (i) Empty container shall become Govt property & shall be taken on charge throrugh receipt voucher. (ii) oil shall be used for top up only. (iii) Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work. (iv) The contractor is required to submit the di-electric report of each transformer before claiming payment. (v) Purchase vouchers alongwith manufacturer's test certificate shall be produce at the time of payment.
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth lead strip 32x6 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI medium grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion including taking down of existing earthing as exists on site complete all as specified and as directed. Notes :- (i) Any increase in length of earth strip and protection pipe of earth strip beyond 7.5 mtr length shall be measured and paid separetely. (ii) On testing if the earth resistance is not obtained, earthing will be generated at no extra cost ,till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 0.5 mtr away from the earth electrode.
Material and labour for cleaning of substations building B,C and D (without manning) inside walls, ceiling, floor and outside wall, plith protection with suitable brush / broom & wiper and removing wild vegitation around substation buildings up to boundary wall. Note :-(i) Each sub station cleaning measured as one job . (ii) T&P items required for cleaning is deemed to be included in this item.
R D Bansal
Northern cable fault locatoers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .