Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.4 L+₹15,541.67 (0.81%)Rejected-Finance | L2 | Rejected-Finance Other lowest bidder | |
| 3 | L3₹22.1 L+₹2.9 L (14.9%)Rejected-Finance | L3 | Rejected-Finance Other lowest bidder | |
| 4 | L4₹23.3 L+₹4.1 L (21.3%)Rejected-Finance 180 SECTOR 1 CHANNI HIMMAT CHANNI HIMMAT JAMMU JAMMU JAMMU AND KASHMIR 180015 UDYAM JK 07 0006292 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-Finance Other lowest bidder | |
| 5 | L5₹24.7 L+₹5.5 L (28.7%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L5 | Rejected-Finance Other lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
GE AF JAMMU
CA NO GE/AFJ-38/2021-22 REPAIR CLEANING REPLACEMENT OF SEWAGE LINES NPT LINES SWG LINES AND SEPTIC TANKS OF DOMESTIC AREA OF AF STN JAMMU
2021_MES_482495_2
CA NO GE/AFJ-38/2021-22
Open Tender
Civil Works
Item Rate
GE (AF) JAMMU
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹40,000
Yes
10 Feb 2022
2 Dec 2021
25 Dec 2021
2 Dec 2021
23 Dec 2021
9 Dec 2021
60 days
Amount
Cleaning manually of blocked WC seat trap, inside house and gully trap it includes remove/refixing of grating and cleaning of WC's trap,kitchen/bath traps any type/pattern (pedestal/squatt pattern) upto 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engr-in-Charge including cleaning of 1st manhole and removing the waste material/ sludge etc to a distance n.exc 50m and burring the same in pits (All work to be carried out under foul conditions i.e. under running conditions, rates shall be quoted considering the same) complete all as directed by Engr-in-Charge.(Measurement will be carried out each time depending on the blockage)
Cleaning/clearing manually or mechanically the sewage line of any description / SGSW pipe of size 100mm dia to 200mm dia at any depth , removing any type of blockage including destling , descaling & dechocking by using sewage cleaning rods or with combine hydralic operated sewer suction cum jetting machine mounted on LCV/HCV by using high pressure thermo plastic water jetting hose and throgh conical ronnd shaped nozzle with piston action rodding from manhole to manhole or from manhole to septic tank / well through sewer line when as required time to time including taking off manhole cover and cleaning of manholes of any size and depth and reomving waste material/sludge to a distance of n.exc 50m and burrying the same pit and replacing manhole cover in position after cleaning (All work to be carried out under foul conditions i.e. under running conditions, rates shall be quoted considering the same) complete in all respect all as directed by Engr-in-charge. (Measurement will be carried out each time depending on the blockage)
ditto as per above item but pipe of size 300 mm dia at any depth etc complete in all respect all as directed by Engr-in-charge.
Cleaning of septic tanks, soakage well/pits, grease traps etc of any depth including inlet and outlet chamber and removing sludge(in solid & semi solid ), silt, both organic and in-organic nature including any other type of waste material after plugging of incoming sewage line and removing waste material /sludge etc to a distance n.exc 100m and burrying the same in pit (All works to be carried out under foul conditions i.e. under use conditions, rates shall be quoted considering the same) Complete all as specified and directed by Engr-in-Charge.
Bailing out water directly from septic tank/soakage well/manhole/grease trap of any size and any depth with suitable capacity pumps/suction machine to a distance not less than 50 metre away in such a manner as to Disposal of water, not to cause inconvenience /nuisance in the area or to cause damage to the property structures near by all as spd and directed by Eng-in-charge (All works to be carried out under foul conditions i.e. under use conditions, rates shall be quoted considering the same).
Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m depth in foundations etc for manholes, sewage line and and getting out complete all as specifed or directed by engineer incharge
Excavation in trenches in any type of soil n.exc 1.5m wide and exc 1.5m but not exc 3.00 mtr depth in foundations etc for manholes, sewage line and and getting out complete all as specifed or directed by engineer incharge
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed or directed by engineer incharge
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed or directed by engineer incharge
Demolition of brick work or stone/ boulder masonary , bult in cement mortor incl all quoins, arches, pillars etcincluding depositing unservicable brick and stacking for reuse including cleaning of bricks and deposting off all debries & rubbish off permises to a distance not exceeding 100 mtr complete all as specifed or directed by engineer incharge
Material and labour Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 for manhole etc in same mortar as the work proceeds. Complete all as specified or directed by engineer incharge
All as per srl item above here-in-before specifed but except bricks complete in all respect as specified or directed by engineer incharge
Demolition and breaking up drain pipes 150 mm dia. (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete in all respect as specified or directed by engineer incharge
Demolition and breaking up drain pipes 200 mm dia. (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete in all respect as specified or directed by engineer incharge
Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cemnt concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm complete in all respect as specified or directed by engineer incharge
Supply and Fixing of Reinforced concrete pipe class NP-2 laid and jointed complete with coller 150 mm dia complete in all respect as specified or directed by engineer incharge
Supply and Fixing of Reinforced concrete pipe class NP-2 laid and jointed complete with coller 200 mm dia complete in all respect as specified or directed by engineer incharge
Supply and Fixing of Reinforced concrete pipe class NP-2 laid and jointed complete with coller 300 mm dia complete in all respect as specified or directed by engineer incharge
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150mm bore pipes complete in all respect as specified or directed by engineer incharge
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 200mm bore pipes complete in all respect as specified or directed by engineer incharge
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 300mm bore pipes complete in all respect as specified or directed by engineer incharge
Demolition of cement concrete (unreinforced) as in any discription and any position n exc 15cm thickness (below or above ground level) including deposal off rubbish to a distance not exc 100 mtr complete in all respect as specified or directed by engineer incharge
M & L for PCC 1:4:8 type D-2, 75 mm thick (using 40 mm graded stone aggregate) as in sub base complete in all respect as specified or directed by engineer incharge
Material and labour Cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) in foundation filling and mass concrete complete in all respect as specified or directed by engineer incharge
M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster of any description on brick wall and concrete surface etc including rackimg out joints,hacking for keys all as specifed and as directed by Engineer-in- Charge.
Material and labour Rendering 15mm thick on brick surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete in all respect as specified or directed by engineer incharge
Demolition of reinforced cement concrete of man hole covers/cover slabs complete in all respect all as directed by Engr-in-charge.
Precast cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover all as specifed including form work complete set in CM 1:4 complete in all respect as specified or directed by engineer incharge
S&F HDPE (High Density Polyethylene) manhole cover with frame of any colour approved by Engr-in-charge and making good old manhole opening for fixing of the following size of following sie of manhole cover of Size 675 mm x 675 mm thickness not less than25mm complete in all respect as specified or directed by engineer incharge
S&F HDPE (High Density Polyethylene) manhole cover with frame of any colour approved by Engr-in-charge and making good old manhole opening for fixing of the following size of following sie of manhole cover of Size 600 mm x 600 mm size thickness not less than25mm complete in all respect as specified or directed by engineer incharge
S&F HDPE (High Density Polyethylene) manhole cover with frame of any colour approved by Engr-in-charge and making good old manhole opening for fixing of the following size of following sie of manhole cover of Size 600 mmx 450 mm size thickness not less than25mm complete in all respect as specified or directed by engineer incharge
S&F HDPE (High Density Polyethylene) manhole cover with frame of any colour approved by Engr-in-charge and making good old manhole opening for fixing of the following size of following sie of manhole cover of Size 450 mm x 450 mm size thickness not less than25mmcomplete in all respect as specified or directed by engineer incharge
Supply and fixing Deformed or TMT steel bars 8mm or 10mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete in all respect as specified or directed by engineer incharge
Mild steel angle iron/flat Iron work as in manhole cover framesetc complete all as specified and directed by engr in charge..
RCC 1:2:4 type B-1 (20 mm graded stone agg) as in shelves, facia beams ,chajjs slabs, similar suspended work including necessary form work etc complete. Etc complete in all respect as specified or directed by engineer incharge
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete in all respect as specified or directed by engineer incharge
S&F in reapir vitreous china wash down water closet pan ( pedestal pattern ) white complete including ‘P’ or ‘S’ trap , seat cover and fixing of flushing cistern, brackets, flushing pipe etc complete in all respect as specified or directed by engineer incharge
S&F in repair vitreous china Orissa pan of pattern, long pan size 580x440mm , with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete, including cement concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe. complete in all respect as specified or directed by engineer incharge
S&F in repair PVC valve less, syphonic action type flushing cistern, low level with inlet, ball valve float and handle including brackets of capacity 10 ltrs incl PVC connection wih brass nut on both ends and PVC flush pipe. complete in all respect as specified or directed by engineer incharge
Taking down CI pipe (any size or pattern) incl fittings such as bends, shoes, head, swan neck etc incl cleaning for refixing or removal from site complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) pipes 150mm single socketed , in any length with rubber ring joints , laid in trenches or in floors complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints , laid in trenches or in floors complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints fixed to walls complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) pipes 75mm single socketed , in any length with rubber ring joints fixed to walls complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) pipes 75mm single socketed , in any length with rubber ring joints , laid in trenches or in floors complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) bends110mm complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) bends75mm complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) vent cowl 110mm complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) vent cowl 75mm complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) junction single,(Single T) equal or unequal 110 mm bore complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) branch piece (single Y) equal or unequal 110mm bore complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) floor trap , plain with grating including jointing with solvent cement complete in all respect as specified or directed by engineer incharge
M&L in repair/ replacement of PVC (SWR) reducers 110mm bore complete in all respect as specified or directed by engineer incharge
Supply and fixing stack clamp cut of 50 x 5mm flat iron and 16mm dia round iron stays including bolt and nuts and securing ends of stay to water pipes suitable for 100 mm dia pipe including taking down unservicable clamp all as spd and directed by Engg-in-Charge
S&F cast iron oval access doors 100mm complete in all respect as specified or directed by engineer incharge
S&F cast iron oval access doors 75mm complete in all respect as specified or directed by engineer incharge
M&L for colored non skid ceramic tiles 7to 8 mm thick, area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:6 to match Shade, pattern, laying etc of tiles as directed at site complete in all respect as specified or directed by engineer incharge
M&L for 300x200 x7 mm thick glazed ceramic tiles colored as in dado/ skirting and vertical surfaces set&jointed in neat cement slurry and pointed in colored cement over and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tiles as directed at site complete in all respect as specified or directed by engineer incharge
Cement concrete chequered tiles 25cm x 25xm x22mm thick, machine pressed; set, jointed and pointed in net cement slurry in floors, and cut and polished with grey cement and no pigment, laid over 20 mm thick bedding layer of cement mortar 1:4 all as specified and directed by Eng-in charge
Machine pressed precast concrete inter locking paver blocks any size and shape of 60mm to 65mm thickness, M-35 grade with Grey crment and no pigment laid over 20 mm thick bedding layer of cement mortar 1:4 all as specified and directed by Eng-in charge
Dismantling existing unservicable floor/wall tiles of any description including bedding/screed layer all as specifed.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note:-(i) All items of standards Quality/ISI/Approved items to be incorprted in the work.the items to be approved by GE before procurment. (ii) The repairs can be under taken as and when required basis accordingly site will be available in piecemeal wise and as directed by Engr-In- charge in the domestic area of AF Stn. (iii) One Supervisior alongwith Two Conservency staff to be detailed to report daily except Sunday/holidays at Complaint cell to collect complain slip from Complaint Cell and returned back the same after completed the work daily.
ASHFAQ AHMED MANHAS
M/S DC CONSTRUCTIONS
Tawi Constructions
s s construction
M/S CHOUDHARY BUILDERS
M/s Sunny Gupta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .