Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹25.3 L+₹1.6 L (6.64%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-Finance Being other than Lowest | |
| 3 | L3₹25.5 L+₹1.7 L (7.34%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L3 | Rejected-Finance Being other than Lowest | |
| 4 | L4₹32.9 L+₹9.2 L (38.7%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Being other than Lowest |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
6 Jun 2020, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR ROUTINE MAINTENANCE OF FIRE FIGHTING SYSTEM OF OUTLAYING AREAS UNDER GE NW NOFRA COLABA MUMBAI 2 ND Call
2020_MES_340276_2
8628/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
360 days
GE NW NOFRA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NW NOFRA
₹61,000
Yes
27 Jun 2020
23 May 2020
9 Jun 2020
23 May 2020
6 Jun 2020
23 May 2020
Amount
Part I Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at GANGOTRI Building (G+15) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc (c) All wiring & cable connections (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.).(f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage.(i) Testing of all Sluice Valve, NRV & Air Release Valve. P.M.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at BHAGHIRATI Building (G+15) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity.(e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.).(f) 10HP Jockey Pump Servicing & Testing (01 No.).(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage.(i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at ADITI Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity.(e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.) (f) 10HP Jockey Pump Servicing & Testing (01 No.).(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at AHILYA Building (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity.(e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.).(f) 10HP Jockey Pump Servicing & Testing (01 No.).(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage.(i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at VANDANA Building (G+15) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity.(e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.).(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at VISHAKA Building (G+15) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections. (d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.). (f) 10HP Jockey Pump Servicing & Testing (01 No.). (g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage. (i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at SASSON COMPLEX – Four Building(Akash, Chandra, Badal & Diwakar) (G+12) comprising following:- (a) Twenty Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity.(e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.).(f) 10HP Jockey Pump Servicing & Testing (01 No.).(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage.(i) Testing of all Sluice Valve, NRV & Air Release Valve.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at INS SHIKRA(ATC TOWER) Building (G+7) comprising following:-(a) Ten Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity.
Routine maintenance of Fire Fighting System, Fire Alarm System by attending fault testing of system, Monthly checking of system etc. including replacement of unserviceable components/parts other than those mentioned in schedule “A” Part-II for Fire Fighting System, Fire Alarm System installed at BOATPOOL WORKSHOP Building (G+1) comprising following:- (a) Ten Zone Main Fire Alarm Control Panel with each zone battery charger and 230 V power units.(b) Ionization type smoke detector, head detector, response indicator, manual call point and hooters etc.(c) All wiring & cable connections.(d) Lead acid battery 12V/9AH Capacity. (e) 60HP Main Fire Hydrant Pump Servicing & Testing (02 Nos.).(f) 10HP Jockey Pump Servicing & Testing (01 No.).(g) Testing of Electrical control panel of Fire Fighting System Water Pumps.(h) Testing of Pressure switch & Pressure Guage.(i) Testing of all Sluice Valve, NRV & Air Release Valve.
Part II Supply only transformer AC/DC for fire alarm system panel of electronic type complete all as specified and directed
Supply only battery duly charged 12 V, 7.2 AH.Make: EXIDE or Equivalent as approved by GE
Supply only Zone cards. Make : HITESH or Equivalent as approved by GE
Supply only power cards Make : HITESH or Equivalent as approved by GE
Replacement of manual call point suitable for addressable system duly painted in red colour paint with front glass (to be broken in case of fire ) complete with test key to check the response with out breaking the glass and die cast aluminum housing with IFD indicator complete all as specified and directed Make:- GURUTRONIC / HARDIK ENGINEERS or Equivalent as approved by GE
Supply only electronic hooters. Make : GURUTRONIC / HARDIK ENGINEERS
Supply only Addressable type Smoke / Heat detector. Make : APOLLO / MORLEY or Equivalent as approved by GE
Supply only hydrant valve wheel complete.
Supply only hydrant gun metal female coupling.
Supply only rubber hose drum adopter connection (shank reducer).
Supply only brass lock pin (lugs) for 63 mm dia.
Supply only hydrant valve spindle.
Supply only rubber hose pipe 20mm dia, plain 2 ply rayon braided high pressure. Make : DEEP JYOTI / DUNLOP or Equivalent as approved by GE
Supply only Aluminium nozzle suitable for 20 mm dia rubber hose pipe.
Supply only 100 mm sluice valve wheel.
Supply only brass hydrant valve nut as per existing size.
Supply only blank flange of size 100mm made out of MS 12 mm thick including flange joint.
Supply of PVC blank cap of hydrants with GI chain.
Supply & Fix Factory fabricated MS fire cabinet box as per give design made out flat CRCA of appropriate size and thickness all as directed including two coat of powder coated approved colour synthetic enamel paint over a coat of red oxide primer & fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified and directed
Supply and fix MS plate in short pieces of appropriate size & thickness required as per site requirement to existing fire cabinet box by means of welding including two coat of synthetic enamel paint (approved colour) over a coat or red oxide primer complete all as specified and directed
Supply only canvas fire hose 63mm dia bore 30metre long confirming to IS Having male/female brass coupling both end complete all as specified and directed
Supply only brass Nozzle 25 mm bore suitable for 63mm dia canvas pipe complete all as specified and directed
Excavation in trenches n.ex.c 1.5 meter wide and n.exc 1.5 meter in depth for foundation etc for shafts, wells, cesspits,manholes,pier holes, etc n.exc 1.5min depth and getting out in hard/dense soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Returning, filling is including spreading, leveling, watering and well ramming in layers n.exc. 25cms(Soil) complete all as specified and directed.
Cutting out concrete blocks, slabs, brickwork or stone masonry(in alternate course) forming toothings for and bonding new work in mortar into old work, including new materials entering old wall complete all as specified and directed.
Taking down existing double acting valve of size 100 x 65mm for servicing including replacement of unserviceable spares ie gland, nut, bolt, lock pin, CI hand wheel with chain, etc complete and re-fixing in position in high rise bldg not exceeding 15 stories complete all as specified and directed.
Supply & Fix Gun metal double acting fire hydrant valve of size 100 x 65mm conforming to IS – 5290/71 with all fitments such as cap cover instantaneous coupler for making flanged joint 100mm dia bore complete all as specified and directed.
Repairing to MS front door of size not exceeding 1.5 mtr x 1.5mtr including welding locking arrangement including providing pad lock 50mm complete all as specified and directed (Make : GODREJ/NAVTAL) or Equivalent as approved by GE
Preparing old painted surface of CI/MS pipe 100mm dia and applying two coats of synthetic enamel paint (Red colour) including a coat or red oxide primer” complete all as specified and directed
Servicing of hose reel drums by applying greasing, oiling etc and making free rotation to hose drum complete all as specified and directed
Removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer on fire fighting cubical box fitted inside bldg on each floor complete all as specified and directed.
Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Cease fire / Apollo / Hardik Engineer / Gurutronic
Supply & Fix in repairs MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls, complete all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
MS flanges duly drilled including welding to MS pipes under item No 34 herein before complete all as specified and directed
Material & Labour for flanged joints for 100mm bore pipe at any location and position for item 34 herein before complete all as specified and directed.
Supply only Gun metal fire hydrant single acting of size 80x63mm for stand post complete all as specified and directed.
Supply & Fix in repairs sluice valve, 100mm size, both ends flayed with high tensile brass spindle,cast iron body, as per IS-14826 & ISI Marked,PN-1.6 pressure rating including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified and directed Make:Sant / KIRLOSKAR/LEADER
Supply & Fix in repairs mild steel, conforming to Fe-410-0 or Fe-310-0, as in framed brackets of angles, cut to shape, drilled and counter sunk for screw including bending and welding as necessary guest plate, riveting complete all as specified and directed
S&F Non return valve, ball type, conforming to IS, Model B-05, of size 100mm complete all as specified and directed. (Make : Kirloskar/Normex/ Leader)
Rewinding of electrical induction motor uo to 15HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site complete all as specified and directed.
Rewinding of electrical induction motor uo to 75HP capacity 3 phase 415 V of terrace booster pump of high rise bldg, including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site complete all as specified and directed.
Repair/maintenance of booster pump capacity upto 15 HP including necessary replacement of shaft impeller, bearings gun metal bush and coupling complete all as specified and directed
Replacement of electrical motors star delta starter fully automatic of capacity upto 15 HP complete all as specified and directed
Supply and fix in repairs FOOT valve, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, complete all as specified and directed Make:- (Kirloskar/Normex/Leader)
Supply,installation of 1.5 Sqmmx 6 Core Copper Armored Cable Make Polycab/Plaza/Gloster
shakti engineering and electrical works
Saviour Security Systems
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .