Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.9 L+₹1.9 L (13.9%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
22 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
REPAIR/REPLACEMENT OF HT DISTRIBUTION SYSTEM AND ALLIED WORK AT CERTAIN LOCATIONS UNDER GE RANGIA
2023_MES_629740_1
CWE/TEZ(R)/T-52 of 23-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Rangia
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹30,000
Yes
13 Jan 2024
24 Nov 2023
25 Dec 2023
24 Nov 2023
22 Dec 2023
8 Dec 2023
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft/ loose soil for laying cables / GI pipe, foundation of pole, stay etc., complete all as specified and as directed by Engr-in-Charge.
Returning filling in approved earth in trenches including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in layers in soft / loose soil after the cabels are laid and tested complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Material and labour sand filling in trenches with clean dry unwashed sand for cushioning of under ground cable complete all as specified and as directed by Engr-in-Charge. Note : Punned thickness of sand will be measured.
Supply and laying unreinforced precast concrete cable cover, class HV, Type-I, flat size 300mm x 180mm x 40mm thick laid dry for protection of UG cable complete all as specified and as directed by Engr-in-Charge.
Supply, laying, testing & commissioning in repair of HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road complete all as specified and as directed
Supply and fixing in repair GI Pipe light grade 80 mm dia under road crossing / on pole with necessary clamps, nuts, bolts and washers etc for protection of PVC/XLPE cable complete including taking down old unserviceable one all as specified and directed.
S&F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size all as specified and directed.
M&L in repair for Triple pole, mechanically operated, gang operated switch, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps 11000 Volts, including taking down the existing old unserviceable Switch, complete all as specified and as directed by Engineer-in-charge.
M&L in repair for Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 Volts, including taking down the existing old unserviceable arrester, complete all as specified and as directed by Engineer-in-charge.
M&L in repair for expulsion fuse assembly single pole vertically mounted on MS channel 11000 volts grade upto 100 amp capacity including making connections with HT cables/ GOD with provision of jumper all as specified and as directed
M&L in repair for earthing complete with galvanised steel earth plate electrode 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32 × 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all, earth plate sourrounded by filling sourrounded from all side mixture of charcaol and common salt, providing 40 mm dia light grade protection pipe for GI strip , GI medium grade 20 mm pipe for watering including funnel with wire mesh on top , CI cover with frame , PCC chamber pit with PCC 1:3:6 type C-2 , incl excavation and earth work all as shown in electrical earth plate No 3 and specified and indicated including testing of earthing on completion and taking out the old unsv earth pit all as specified and as directed. Note : The unit rate includes for protection pipe and GI strip from top of earth plate up to 7.5 mtr above ground level.
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Material and labour in repair for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed by Engr-in-Charge.
M&L in repair Stay Assembly complete with Accessories as show in Electrical Plate No.1 of MES Schedule Part-I, diameter of Stay Rod 16mm, size of Plate 230x230x6mm complete all as specified and as directed by Engr-in-Charge. Note: Rate of Earthwork, Cement Concrete, Mild Steel Stay Clamps etc. will be included in the quoted rate.
Supply and fixing in repair galvanised stay strand of size 7/3.15mm with nut bolts complete all as specified and as directed by Engr-in-Charge.
S&F in repair Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90 x 140mm, clearance of hole 25.5 mm dia, complete all as specified and as directed by Engr-in-Charge.
M&L in repair for Filteration and dehydration of HV grade transformer oil of distribution transformer of out door/ indoor type of 11/.433 KV, 25 KVA to 500 KVA and min three cycle to achieve die elctric strength of up to 60KV with 2.5 mm gap as per relevent IS with ultra high vacuum portable filteration machine, testing the oil for die elctric strength, break down voltage before filteration and after filteration complete all as specified and directed by EIC. Note : (i) Filteration to be done by Dehydration machine till the desired level of dielectric strength of tranformer oil comes to 60 KV . (ii) The contractor will test the dielectric strength of oil of each Tranformer & voltage stabilizer before starting dehydration & filteration and after completion of dehydration & filteration process and he will submit a record of same. (iii) Each sample of oil will be tested with a transformer oil test machine at site in presence of concerned Engr-in-charge and test result will be submitted accordingly). (iv) Centrifugal machine filteration plant with all T&P and BDV Testing Machine etc all as required to be arranged by contractor with out any extra cost. (v) Oil required for topping up the transformer oil will be measured and paid seperately in relvent item.
Supply, fill and pouring of new transformer oil having di-electric strength BDV value not less than 60 KV in 2.5mm gap, conform to IS-335-1983 , supplied in sealed barral, contains 210 litre oil in each. Make : Sabita/Golf/Power/Trans oil. Note : Transformer oil shall be bring in sealed barrel having proper test certificate from manufacturer. Contractor shall submit the test certificate of oil before fill/ top up in transformer.
Taking out old u/s breather and Supply and replace silica gel breather assy made up of aluminium TOP, Powder coated, Transaparent Centre Portion made of Polycarbonate of size, Nitirle rubber O ring connection1/2 " BSP or 3/4 " thread, filled with new Silica Gel Blue (including silica gel crystal) suitable for transformer of capacity 63 KVA to 160 KVA as mentioned below of approved make complete all as specified and directed by EIC.
--Ditto all as per item No 20 above but for 200 KVA to 400KVA transformer.
Taking down the HT vacuum circuit breaker of any make, capacity from 400-630 Amps, 11 KV, 800 Amps for servicing, repairs and re-assembling complete comprising of the following including testing and commissioning all as directed. (a) Checking the serviceability of all parts, cleaning, alignment of closing/opening mechanisms and re-assembling the unit complete and making it smooth functional. (b) Cleaning the external surface of bushings with CRC/ Tri-chloro-ethylene to remove the accumulation of carbon or any other deposits. (c) Checking the VCB panel wiring and repairing for making VC in fully functional condition . (d) Dismantling the spring charging mechanism of the VCB, checking the operations of the closing/tripping through closing/tripping coils electrically as well as manual charging including cleaning re-adjusting worn out parts etc. (e) Checking the condition of the spring charging motor along with gear box including providing servicing to the motor commutator bushes, lubrication of bearing surfaces etc. (f) Calibration of relays and meter of VCB, for making it fully functional and in earth fault, over current etc relay can be work and trip the VCB. (g) Inspecting all bolts, nuts, pins and ensure collar pins are in place and they are tight and opened properly complete all as specified and directed by EIC up to his full satisfaction.
Note for repairing and servicing of VCB : (i) All T&P and instruments, testing kit, primary injection kit to be bring by contractor for repairing, testing and calibration of VCB. (ii) Contractor shall submit the test sheet of VCB testing before and after carried out repaiirng and calibration of relays & meters. Testing of VCB to be done in presence of Engineer in Charge. (iii) Repairing , servicing and calibration of VCB shall be done through expert technician/ engineer of OEM/ Expert technician/ engineer of ASEDCL. (v) Any minor parts not catered in scope if required to be replace for makeing the VCB serviceable to be provided by the contractor without any extra charge.
Disconnecting all in-coming and out-going cables, removing the transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractor's workshop, to carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and outgoing cables by properly crimping using lugs of suitable size, taping the bushes / bus bars, using insulation tape and testing of 11/0.433 KV, 100 to 250 KVA Distribution transformer, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side, rewinding,dehydration of oil shall be measured and paid separately in respective items. (ii) Contractor shall open the transformer/ dismentling of core and winding in presence of Eng in Charge. Eng in Charge shall examine the transformer for cause of fault, damage to the parts, burnt winding and prepare fault / inspection report. Accordingly after carrying out the repair before shifting the transformer to site all the necessary test to be done at factory/ workshop in presence of Engineer in Charge. Test report to be perpared before and after carrying out repair and to be produce at the time of claiming the payment. (iii) Cost of transportation of transformer from its existing site to work shop for repairing and to bring back and installation to its existing place is deemed to be included in above item rate.
M&L in repair for rewinding of burnt winding coil of HV and LV limbs of 11/0.433 KV distribution transformer of capcity up to 250 KVA using new copper wire/strip of appropriate size and gauge , number of turns etc as per existing size of core & winding including insulating materials (double insulation), including heating , baking and varnishing of transformer coils complete all as specified and directed by EIC.
S&F in-repair of ceramic bushing and Gasket on LT side of transformer up to 250 KVA (Make : Mysore Potteries/BHEL), complete all as specified and directed by EIC.
All as per item No 25 above, but on HT side of transformer up to 250 KVA, complete all as specified and directed by EIC.
Supply and fixing in repalcement of complete gasket (Cock sheet) 6 mm thick complete including concial rubber bush for transformer of capacity up to 250KVA.
Material and labour for painting to tranformer up to 250 KVA capacity after scraping and removing old paint and appliying 01 coats of synthetic enamel paint by taking due care of HT/LT side supply all as specified and directed by Engineer-in-Charge.
Disconnecting all in-coming and out-going cables from unfunctional servo stabilizer and removing from power house bldg for loading it in the vehicle carefully using crane and transporting it to the workshop to carry out the Overhauling/servicing of servo controlled voltage stabilizer of capacity upto 30 KVA, 3 phase, input, voltage range 340-480 volt, output voltage range 415 + 2.5 % volt, 50 Hz, oil cooled, copper winding, checking of healthiness and serviceability of stablizer , inspecting/ checking / diagonisis of defect, change of burnt winding and removing old burnt wire, change of unsv voltmeter, amp meter, push button, Indicator LED bulb, replacement of nut bolts, pins,replacement of defective circuit board, control card, trip card making the stablizer functional and transport back at site , installation, commissioning and testing after reconnect all the incoming and outgoing cables, incl replacement of old lugs with new one complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor shall submit the test sheet of Servo stabilizer testing before and after carried out of repair .Testing of servo stabilizer to be done in presence of Engineer in Charge. (ii) Repairing , servicing shall be done through expert technician/ engineer of OEM/ Expert technician. (iii) Any minor parts not catered in scope if required to be replace for makeing the servo stabilizer serviceable to be provided by the contractor without any extra charge. (iv) Oil for top up and copper for winding in case of burnt will be paid under appropriate item.
Disconnecting all in-coming and out-going cables from unfunctional servo stabilizer and removing from power house bldg for loading it in the vehicle carefully using crane and transporting it to the workshop to carry out the Overhauling/servicing of servo controlled voltage stabilizer of capacity above 30 KVA upto 50 KVA, 3 phase, input, voltage range 340-480 volt, output voltage range 415 + 2.5 % volt, 50 Hz, oil cooled, copper winding, checking of healthiness and serviceability of stablizer , inspecting/ checking / diagonisis of defect, change of burnt winding and removing old burnt wire, change of unsv voltmeter, amp meter, push button, Indicator LED bulb, replacement of nut bolts, pins, replacement of defective circuit board, control card, trip card, making the stablizer functional and transport back at site , installation, commissioning and testing after reconnect all the incoming and outgoing cables, incl replacement of old lugs with new one complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor shall submit the test sheet of Servo stabilizer testing before and after carried out of repair .Testing of servo stabilizer to be done in presence of Engineer in Charge. (ii) Repairing , servicing shall be done through expert technician/ engineer of OEM/ Expert technician. (iii) Any minor parts not catered in scope if required to be replace for makeing the servo stabilizer serviceable to be provided by the contractor without any extra charge. (iv) Oil for top up and copper for winding in case of burnt will be paid under appropriate item.
Dismantling of ACSR conductor of any type and size complete all as specified and directed.
Taking down , dismentling, old rusted cross arms of MS channels or angle sections etc complete and setting aside for reuse or given credit to contractor under credit of schedule, complete all as specified and directed by EIC.
Dismantling of insulators any type any size complete all as specified and directed.
Dismantling of Stay assy complete all as specified and directed.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
SONI ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .