| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹17.4 L+₹9.4 L (116.5%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Category c(i) |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR/MAINT OF SUMMER APPLIANCES WITH PLANT AND ACCESSORIES AT AF STATION KANHERI HILLS UNDER GE (AF) THANE
2022_MES_520809_1
8201/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF THANE
₹20,000
Yes
1 Aug 2022
29 Apr 2022
27 May 2022
29 Apr 2022
26 May 2022
14 May 2022
29 Apr 2022 - 14 May 2022
60 days
Amount
Supply and fixing PCB circuit for intelligent cooling ambient sensor suitable for 8.75 TR AC plant.Make Blue star.
Supply and fixing DLT sensor suitable for 8.75 TR AC plant. Make Blue star.
Supply and fixing Acoustic insulation suitable for 8.75 TR AC plant.Make Blue star.
Supply and fixing thermostate suitable for 8.75 TR AC plant Make Blue star.
Supply and fixing PVC blade for condenser blower suitable for 8.75 TR AC plant.Make Blue star.
Supply and fixing Filter suitable for 8.75 TR AC plant.Make Blue star
Supply and fixing PCB circit for intelligent cooling ambient sensor suitable for 7.0 TR AC plant Make: SCHNEIDER LEONARDO. At AFStn Kanheri Hills Top .
Supply and fixing DLT sensor suitable for 7.0 TR AC plant .Make: SCHNEIDER LEONARDO. At AFStn Kanheri Hills
supply and fixing Acoustic insulation suitable for 7.0 TR AC plant. Make: SCHNEIDER LEONARDO.
supply and fixing thermostate suitable for 7.0 TR AC plant.Make: SCHNEIDER LEONARDO
supply and fixing PVC blade for condenser blower suitable for 7.0 TR AC plant.Make: SCHNEIDER LEONARDO.
supply and fixing Filter suitable for 7.0 TR AC plant. Make: SCHNEIDER LEONARDO.
Equipment & labour for servicing of Split type AC 1.5 Ton / 2 ton , Window type AC 1.5/ 2 Ton , water cooler, refrigerator, and deep freezer of any size & capacity by taking out from its position cleaning dirt, dust checking all the electrical connections and re fixing in its original position all as directed.Note-servicing of machine of when required basisomplete all as specified and directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Split type AC 1.5 TR capacity including nessessary fittings with existing unit complet all as directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Split type AC 2 TR capacity including nessessary fittings with existing unit complet all as directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Water cooler of cap 150 ltr. including nessessary fittings with existing unit complet all as directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Water cooler of cap 80/40 ltr. including nessessary fittings with existing unit complet all as directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Deep freezer of cap 400 ltrs. including nessessary fittings with existing unit complet all as directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Refrigerators 165 ltrs/ capacity. including nessessary fittings with existing unit complet all as directed.
S&F in replacement of U/S sealed type compressor unit re-appropriated by the manufactures suitable for Refrigerators 180/210 ltrs/ capacity. including nessessary fittings with existing unit complete all as directed.
S&F in replacement magnetic gasket for Water cooler of any Make and any capacity.
S&F for replacement screw/pin type shell light bulb.
S&F for replacement condenser coil for Split AC 1.0, 1.5 & 2.0 TR capacity .
S&F for replacement condenser coil of water cooler of any size and any capacity.
S&F for replacement condenser unit for refrigaretor any capacity.
S&f in replacement of chilling door for any type of refrigerator.
S&F in replacement of chilling tray for any type of refrigerator..
S&F in replacement of door push buttom.
M&L for replacement of capillary tube refrigerator.
M&L for replacement of capillary tube for Split type air conditioner 1.0/1.5/2.0 Ton.
M&L for replacement of capillary tube for watercooler of any size
S&F in replacement of housing (outer cover) for Split type AC as per sample.
S&F in replacement of front grill for AC of any capacity as per sample.
S&F in replacement of Indoor cabinet for split type AC of any make and any capacity or as per sample.
S&F in replacement of Outdoor cabinet for split type AC of any make and any capacity or as per sample.
S&F in replacement of drain tray of water cooler including PVC pipe clamps etc.
S&F in replacement of Indoor unit Blower Motor for split type AC of capacity 1.5 ton.At AF Stn Kanheri Hills
S&F in replacement of Indoor unit Blower motor for split type AC of capacity 2.0 ton.
Supply only Remote control for Split/Window type AC of any make and any capacity or as per sample.
S&F 8 mm dia post anchorage bolts for fixing of equipment on wall.
M&L for Flushing out the Niterogen gas from condensing coil AC 1.5 Ton cap complete and repairs of leaking place by gas welding complete and recharging of referigent (R-12 & R-22 ) all as directed.(Refregent will measured and paid in respective items)
M&L for Flushing out the Niterogen gas from condensing coil AC 2 Ton cap complete and repairs of leaking place by gas welding complete and recharging of referigent (R-12 & R-22 ) all as directed.(Refregent will measured and paid in respective items)
M&L for Flushing out the Niterogen gas from condensing coil Water cooler of cap 150/150, 120/60 and 80/40 ltrs complete and repairs of leaking place by gas welding complete and recharging of referigent (R-12 & R-22 ) all as directed.(Refregent will measured and paid in respective items)
M&L for Flushing out the Niterogen gas from condensing coil Refrigerator of any cap and make.complete and repairs of leaking place by gas welding complete and recharging of referigent (R-12 & R-22 ) all as directed.(Refregent will measured and paid in respective items)
M&L for Flushing out the Niterogen gas from condensing coil Deep freezer upto 400 ltr capacity.complete and repairs of leaking place by gas welding complete and recharging of referigent (R-12 & R-22 ) all as directed.(Refregent will measured and paid in respective items)
Supply and recharging referigent for any type (R-12 & R-22 ) all as directed
S&F in replacement air filter for split/window Air conditioner of any make any capacity.
S&F in replacement relay suitable for cap for AC 1.5/2 ton of any make.
S&F in replacement relay suitable for water cooler 40/80 cap any make.
S&F in replacement relay suitable for Deepfreezer upto 400 ltr cap.
S&F in replacement relay suitable for cap 100/150 water cooler of make as approved by Engr-in-charge.
S&F in replacement of Running capacitor 50+4+ 5% MFD .Make: Havells, Sardar
S&F in replacement of Running capacitor 50+6+ 5% MFD Make: Havells, Sardar
S&F in replacement of Strarting capacitor 100 - 120 MFD for water cooler of any capacity .Make: Havells, Sardar
S&F in replacement of Capacitor 4 MFD Refrigerator of any capacity Make: Havells,Sardar
S&F in replacement of PVC hose pipe for water cooler of any cap complete all as specified and directed.
Disconnecting and taking out brunt out blower motor of Split type AC 1.5 Ton cap opening the motor and removing burnt out winding and rewinding the same with super enameled copper wire of existing gauge and reconnecting in the same position complete all as directed.
All as per Srl item No-59.00 above but blower motor of water cooler of make as approved by Engr-in-charge.
All as per Srl item No-59.00 above but blower motor Deepfreezer/refrigaretor.
S&F in replacement of burn out thermo-state switch suitable for Split/Window type AC1.0/ 1.5/2.0 Ton cap
S&F in replacement of burn out thermo-state switch suitable for water cooler of any capacity.
S&F in replacement of burn out thermo-state switch suitable for Refrigerator of any make.
S&F in replacement of burn out thermo-state switch suitable for Deep freezer of any capacity.
M&L for Removing the worn out old painted from surface of split unit external, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting all as directed.
M&L for Removing the worn out old painted from surface of water cooler, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting all as directed.
M&L for Removing the worn out old painted from surface of water heater 25/50 ltr capacity, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting all as directed.
M&L for cutting and taking out the rusted/damaged portion of the sheet metal of AC/WATER COOLER /DEEP FREEZER /REFRIGERATOR of any capacity and providing new sheet of exiting gauge including welding/brazing as required and painting with two coat of red oxide primer.
Supply and fixed PCB in repairs of 1.0,1.5 Ton and 2 Ton Split type AC
Supply and fix inreplacement for 24 Hours timer for operating 1.5/2 TR split type in 4 to 8 hours time intervals
S&F of Swing motor for split type AC of any size.
S&F Evaporator fan for split type AC of any size.
S&F of Air filter pads PVC type for Split/window type AC of any size.
S&F of 3 way backlite connector of capacity 20Amps
S&F Cripser tray for any type of refrigeretor.
S&F Filter drier for any type of refrigeretor.
M and L for dismantling the indoor and outdoor units of Air conditioner Window/Split type completely, transporting to Workshop for carrying out repairs, transporting back to the site, reinstalling the same on the new /existing location complete all for satisfactory functioning of the equipment all as directed by E-IN -Charge. Note:- 1. Spare replaced during the proces of repair shall be measured and paid separetly under relivant item Sch A. 2. Rates include the cost of dismantling and transporting the AC to workshop and labour element for carrying out repairs. 3 The decision the Engineer -in -charge shall be final and binding on whether machine is required to be sent to workshop for repair or not.
All as per Srl item No. 79.00 here in before but for water cooler of any cap
All as per Srl item No. 79.00 here in before but for refrigerator/deepfreezer of any cap
S&F in replacement of MCB SP 5 to 30 Amps 10 KA
S&F inreplacement of sheet metal enclosure with socket plug single pole and nertral with 2 pin and earth plug and socket complete with and including MCB Sp of 20 Amps capacity
S&F inreplacement of 2.5 sqmm 3 core PVC Sheathed multi-stranded flexible copper cable up to 1.5 mtrs long including connecting up complete
M and L for dismantling the indoor and outdoor units of Air conditioner Window/Split type completely, reinstalled in new location ,including connection commissioning complet all as directed.
Taking down submain wiring cable any number of runs alongwith eirth wire from the existing concealed or surface conduit as directed
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Supply and fix MCB starter single phase current capacity 20 Amps including box suitable for operation of AC 1.5 TR/2.0 TR Capacity Make-Havells/Legrand/Indoasian/North west
Supply and installation, testing and commissioning of high pressure copper R-22/R410A refrigent copper pipe 19mm/13mm thick closed cell elastomeric insulation in tubing all as directed.
Supply and fixing raceways PVC duct cover 100mmx38 mm with 2 compartment, 2 mtr length, all as directed
M &L for cleaning of fins by means of chemical wash with water of Window type AC 1.5/ 2 Ton, water cooler, refrigerator, and deep freezer of any size & capacity by taking out from its position cleaning dirt, dust checking all the electrical connections and re fixing in its original position, all as directed. Note- Cleaning of Fins of above mentioned item of when required basis
venus enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .