Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.9 L+₹38.8 L (938.0%)Rejected-Finance D K CITY C 42 MINNIEBAY POST BOX NO 340 HPO PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹50.0 L+₹45.9 L (1109.5%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹52.6 L+₹48.4 L (1171.2%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹58.0 L+₹53.9 L (1302.8%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Jun 2022, 6:00 pmClosed
GE Minniebay
Junglighat PO Port Blair
REPAIR / MAINT OF EARTHING, LIGHTENING ARRESTORS, GARDEN LIGHTS, BOLLARD LIGHTS AND CONNECTED ITEMS UNDER AGE E/M I AT GE MINNIEBAY, PORT BLAIR
2022_MES_525833_1
8144/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹90,000
Yes
3 Aug 2022
24 May 2022
25 Jun 2022
24 May 2022
21 Jun 2022
7 Jun 2022
Amount
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 25x4 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 40mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I incl replacement of old unsv earthig complete all as specified and as directed Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All accessories required for galvanized steel plate electrode required, as specified and as directed.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (v) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 40mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I incl replacement of old unsv earthig complete all as specified and as directed. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All accessories required for galvanized steel plate electrode required, as specified and as directed.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (v) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper earth strip 25x3 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 40mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6), type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I incl replacement of old unserviceable earthing complete all as specified and as directed Note: (i) Cost of copper earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All accessories required for galvanized steel plate electrode required, as specified and as directed.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (v) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
M&L for replacement of copper earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or above 4 to 16 Mtr above ground level on wall or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, copper strip (99.99 % molecularly copper) using porcelain clit/post insulators, complete all as specified and directed. Note : Manufacturer test report & voucher of copper strip shall be submitted for payment to GE duly verified by Engr-in-Charge
M&L for replacement of copper earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or below 4 Mtr above ground level on wall or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, copper strip (99.99 % molecularly copper) using porcelain clit/post insulators, complete all as specified and directed. Note : Manufacturer test report & voucher of copper strip shall be submitted for payment to GE duly verified by Engr-in-Charge
M&L for replacement of galvanized iron earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6 mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and directed by Engr-in-Charge
M&L for replacement of galvanized iron earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 4 mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and directed by Engr-in-Charge.
S&F in repairs Aluminium earth continuity conductor or main earthing lead fixed to wall / recess / chases/ roof for lightning arrester / buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, alluminium using porcelain clit/post insulators with screw/ GI drill bit screw, complete all as specified and directed by Engr-in-Charge
S&F in repair Aluminium earth continuity conductor or main earthing lead fixed to wall / roof top of the fourth floor / Chiminy of incinerator for lightning arrester / fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, aluminium using porcelain clit/post insulators with screw/ self drill GI screw with rubber washer , complete all as specified and directed by Engr-in-Charge
M&L for taking down/ up and re-fixing for Aluminium earth continuity conductor fixed to wall / roof top of the fourth floor / Chiminy of incinerator for lightning arrester / fixed to poles or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick to 25 mm x 3 mm thick, alluminium using porcelain clit/post insulators with screw/ self drill GI screw with rubber washer , complete all as specified and directed by Engr-in-Charge
M & L for in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanized iron or steel wire complete all as specified and as directed by Engr-in-Charge
S&F in replacement GI tubing ISI marked 40mm dia, light grade with all fittings fixing on top of the building for fixing of Air terminal complete all as specified and as directed by Engr-in-Charge
S&F in replacement GI tubing ISI marked 32mm dia, light grade with all fittings laid in trenches or fixed to wall complete all as specified and directed by Engr-in-Charge
S&F in replacement of GI tubing ISI marked 20mm dia, light grade with all fittings laid in trenches complete all as specified and as directed by Engr-in-Charge
S&F in replacement of test point terminal block made of gun metal or phosphorous bronze, size 75mm x 75mm x 25 mm thick, drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws, including MS box 2 mm thick of suitable size for protection of test point terminal complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Air termination, single pointed, copper rod 12 mm dia and 300mm long (99.99% molecularly copper) fixed on copper strip for earth conductivity to ground complete all as specified and as directed by Engr-in-Charge
M&L for checking of existing old earthing pits and lightening conductors and repairs/replacement of GI/Aluminium/copper strips where found corroded and repairs to pits and testing of earth resistance value and pouring salt/charcoal/chemical and changing of plate as required for obtaining earth value less than 2.0 ohms complete all as specified and as directed by Engr-in-Charge Note : Salt, charcoal, chemical and earthing plates shall be measured and paid separately under relevant item of this schedule as supply only
Supply only common salt commercial complete all as specified and as directed by Engr-in-Charge
Supply only charcoal/ carbon breeze (50 Kg Bag) complete all as specified and as directed by Engr-in-Charge.
Supply only Galvanized steel earth plate of size of 60 cm x 60 cm x 6.00 mm complete all as specified and as directed by Engr-in-Charge
Supply only copper plate, size of 60 cm x 60 cm x 3.00 mm (99.99 % molecularly copper)complete all as specified and as directed by Engr-in-Charge
Supply only earth enhancement compound / chemical (Magnesium sulphate) (25 Kg bag) complete all as specified and as directed by Engr-in-Charge
M&L for excavation of earth pit of size 2x3 feet and depth 2.25 Meter by taking out of soil, retuning refilling after placing of earth plate, charcoal and salt and removing surplus soil at a distance of 50 mtr from starting point complete all as specified and as directed Note : Earth plate, charcoal and salt shall be measured and paid separately under relevant item of this schedule as supply only
Note for item No 17 to 23 : Receipt voucher / test report shall be submitted duly verified by Engr-in-Charge before payment of RAR / FB
M&L for cutting vegetation / surface dressing not exceeding 15 cm deep including removing the materials to a distance not exc 60 mtr from starting point complete all as specified and as directed by Engr-in-Charge
M&L for repair of earth pit indicator made out of 16 mm dia and 60 cm long MS Square Bar embedded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 25X30X 3 mm thick fixed on side of earth pit cover complete painting and writing details over the plate ie. Type , Result, Date of measurement and pit number with Black back ground with white paint complete all as specified and as directed by Engineer-in -Charge.
M&L for replacement of PCC earth pit cover of size 450X450 X300 mm including handle arrangement and necessary earth work complete all as specified and as directed by Engr-in-Charge
M& L for in replacement of copper brazing of two copper strip of size from 20X3 to 25X3 mm / copper rod of 17 mm dia and copper strip complete all as specified and as directed by Engr-in-Charge
S&F in replacement of post insulator for earthing strip above fourth floor roof top/ 6-9 Mtr wall complete all as specified and as directed by Engr-in-Charge
S&F in replacement of post insulator for earthing strip floor/ roof /wall complete all as specified and as directed by Engr-in-Charge
S&F in replacement of GI Funnel for watering to earthing complete all as specified and as directed by Engr-in-Charge
Taking down carefully defective gate light fittings of any wattage and make from gate/post and refixing the same in original position after replacement / change of driver / LED light including necessary checking of connection including removing the oxidization complete all as specified and as directed by Engr-in-Charge Note : LED light and drivers shall be measured and paid separately under relevant item of this schedule as "Supply only"
Supply only electronic driver for 35/40 W LED light complete all as specified and as directed by Engr-in-Charge
Supply only LED light 35/40 W light complete all as specified and as directed by Engr-in-Charge
Taking down carefully defective bollard light fittings of any wattage any make from garden and refixing the same in original position after replacement /change of driver/LED light including necessary checking of connection including removing the oxidization complete all as specified and directed by Engr-in-Charge
Supply only electronic driver for 9/10/12 W bollard bollard complete all as complete all as specified and as directed by Engr-in-Charge
Supply only LED bollard light 9/10/12 W complete all as specified and as directed by Engr-in-Charge
S&F in repairs PVC conduit medium grade of size 20mm on wall /roof with help of screw and GI saddle including re-fixing of existing serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed by Engr-in-Charge
S&F in repairs PVC conduit medium grade of size 25mm on wall /roof with help of screw and GI saddle including refixing of existing serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed by Engr-in-Charge
S&F in repairs PVC flexible conduit of size 25mm including fixtures complete all as specified and as directed by Engr-in-Charge
S&F in repairs PVC flexible conduit of size 20mm including fixtures complete all as specified and as directed by Engr-in-Charge
M&L for replacement of sub main wiring with 2 runs of 2.5 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 1.5 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed by Engr-in-Charge. Note : 3 run of cable and one run of conduit shall be measured as one unit
S& F in replacement aluminium cable lugs for fixing of armored cables of following sizes in panels complete all as specified and as directed by Engineer-in-Charge:-
Supply, installation, testing and commissioning of change over pillar box double door CPRI approved of size 800x600X450mm, suitable for 3 phase 415 Volts , out door made out 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 400Amp and including PCC foundation including taking down old unsv rusted pillar box and including the following complete all as specified and as directed: INCOMING (a) ON Load Change Over Box 4 pole 630 Amps - 01 No. (b) LED indicating lamp R-Y-B - 06 Nos. (c) Digital Ammeter with CT's (0-400) - 01 No (d) Digital Volt meter 0-500 Volt - 01 No
Supply, installation, testing and commissioning of change over pillar box double door CPRI approved of size 800x600X450mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 400Amp and including taking down old rusted pillar box PCC foundation as per site requirement to accommodated to the following. INCOMING (a) ON Load Change Over Box 4 pole 400 Amps - 01 No. (b) LED indicating lamp R-Y-B - 06 Nos. (c) Digital Ammeter with CT's (0-400) - 01 No (d) Digital Volt meter 0-500 Volt - 01 No
Supply, installation, testing and commissioning of LT feeder pillar box CPRI approved of size 800x600X450mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 400Amp and including PCC foundation as per site requirement to accommodated to the following including taking down old unsv feeder pillar box:- INCOMING (a) MCCB 4 pole 100 Amp 16 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING (a) Through Bus Bar
S&F in replacement digital Ammeter 0-650 Amps rating including necessary fabrication required and painting the effected area to match with existing complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement on load change over switch 4 pole 630Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement on load change over switch 4 pole 250Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge
S&F in replacement digital Voltmeter 0-750 Volts rating including necessary fabrication required and painting the effected area to match with the existing complete all as specified and as directed by Engineer-in-Charge
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanized steel strip or wire armored electric power cables with stranded aluminium conductors 1100 Volts grade of the the following including taking down/up old unserviceable cable complete all as specified and as directed by Engineer-in-Charge
4 Core 6 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
M&L for taking down / up and relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armored underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with saddling / on pole including after repair and all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 25 Sqmm Core complete all as specified and as directed by Engineer-in-Charge Note : Quoted rate shall be inclusive of earth work, fixing arrangement like cable lugs. glands etc
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable including taking down old unsv DWC pipes complete all as specified and as directed by Engineer-in-Charge
M&L for taking down/up and relaying of serviceable DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed by Engineer-in-Charge
S&F in replacemement of GI pipe of medium grade 40 mm dia ISI marked including fitting / fixture for fixing with wall and road crossing etc. complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -Charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -Charge.
M&L for road cutting, removing of earth material/ surfaces etc , returning filling with earth duly compacted and laying PCC 1:2:4 (using 20mm graded stone aggregate) on top surfaces of thickness not less than 100mm for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed by Engineer-in -Charge.
M&L for fault finding of LT UG Cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed by Engineer-in -Charge. Note:- LT UG Cable, Straight through joint kit and DWC pipe shall be measured and paid separately under relevant items of this schedule
S & F in repairs cable jointing kit for 1100Volt grade cable for straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armored aluminium conductor cable of size 10 to 25 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -Charge.
M&L for re-arranging the serviceable power cable on wall /cable duct of size 10 to 25 Sqmm with saddling with aluminium cable tray with required size of screw inside cable duct complete all as specified and as directed
S&F in repairs IP 66/ 67 thermoplastic polycarbonate cable junction box of size 205X255X92 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of size 25X3 mm ,one no of MCB SP 6 Amp and four way 32 Amp Connector complete all as specified and as directed by Engr-in-Charge
S&F in repairs IP 66/ 67 thermoplastic polycarbonate cable junction box of size 130X180X77 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of size 25X3 mm with four way 32 Amp Connector complete all as specified and as directed by Engineer-in -Charge.
M&L for preparation of old painted surface and applying one coat of synthetic enamel paint upto 1 m height from ground level / coping with black and yellow combination of Zebra pattern to steel tubular / RCC poles having 9 m height and applying one coat of aluminium paint to remaining portion including numbering with radium sticker completer all as specified and as directed by Engr-in-Charge
M&L in replacement of Octagonal GI poles complete with GI base plate finial taper plug, bolts, nuts and screws, with suitable bracket all as specified of height 7 M including necessary Earth work,PCC foundation etc and including refixing of all serviceable fitting / fixture complete all as specified and as directed by Engineer-in -Charge.
S&F in replacement PVC insulated 2.5 Sqmm (nominal area) multi stranded copper conductor 1100 volt FRLS grade twin core cable drawn through CPVC Pipe not less than 20 mm dia including two runs of 25x4mm GI clamp for holding of pipe and connecting the street light fittings complete all as specified and as directed by Engineer-in -Charge.
S&F GI bracket for street lights made out of medium grade ISI marked GI pipe 40mm dia, 1.5 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 32 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed by Engineer-in -charge.
S&F in replacement of service wire Aluminium conductor weather proof 6 Sqmm 2core complete all as specified and as directed by Engineer-in -Charge.
S&F in replacement of service wire Aluminium conductor weather proof 10 Sqmm 2core complete all as specified and as directed by Engineer-in -Charge.
S&F rubber insulation tape 25cm width 2.5 Mtr long for fixing of connection make water proof outside the electrical equipments and also fixing the underground cable where crack arises outside complete all as specified and as directed by Engineer-in -Charge.
M&L for dismantling of old vintage RCC Pole of size 7/9 mtr and clear the debris from site including copping and level the ground including necessary excavation, returning filling and removal of surplus soil complete all as specified and as directed by Engineer-in -Charge.
M&L for dismantling of old vintage steel tubular pole of size 7/9 mtr and clear the debris from site including copping and level the ground necessary excavation, returning filling and removal of surplus soil complete all as specified and as directed by Engr-in-Charge
S&F in replacement 35W LED post top energy saving environmental friendly ,design with symmetrical light distribution, spun aluminium landscape luminair made in cast alluminium spigot housing and IP 65 Protection including necessary connections complete all as specified and as directed
S&F in replacement 10W LED bollard light made in cast aluminium spigot housing with decorative cleare opal acrylic diffuser and IP 65 protection including necessary connections complete all as specified and as directed by Engineer-in -Charge
S&F in replacement 18W LED fittings with holder (E27) post top energy saving environmental friendly antique finish with IP 65 Protection including necessary connections including 18w LED emergency bulb complete all as directed by Engr-in-Charge
S&F in replacement 10W LED fittings with holder (E27) bollard light energy saving environmental friendly with decorative cleare opal acrylic diffuser with IP 65 protection necessary connections including 10w LED emregency bulb complete all as specified and as directed by Engineer-in -Charge
S&F in replacement 40W LED post top fittings energy saving environmental friendly ,design with symmetrical light distribution,cleare landscape luminair(CDL) made in cast alluminium spigot housing and IP 65 Protection including necessary connections complete all as specified and as directed by Engr-in-Charge
S&F in replacement LED Indicating lamp (R-Y-B) complete all as specified and as directed by Engineer-in -Charge.
Supply and Fabrication GI garden light fittings, pole of height 3 Mtr, 40 mm dia with 0.5 Mtr top, 1.5 Mtr, 50 mm dia and 1 Mtr 63 mm dia in bottom with GI Base Plate with using medium grade of GI Pipe ,Welding including grinding the welded portion and made smooth surface including earth work,PCC foundation complete all as specified and as directed by Engineer-in -Charge.
S&F in replacement of MCB SPN DB double door 4 way IP-43 made of sheet steel Aluminium powder painted with bus bar, neutral link, earth bar and Din rail ,230V including testing complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps including testing complete all as specified and as directed by Engr-in-Charge
S&F in replacement of thermal type MCCB four pole, 16 KA, 60 Amps complete all as specified and as directed by Engr-in-Charge
S&F in replacement of thermal type of MCCB four pole 16 KA 100 Amps complete all as specified and as directed by Engr-in-Charge
S&F in replacement of thermal type of MCCB four pole 16 KA 63 Amps complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCCB TPN/four pole cover of capacity of 63- 160 Amps complete all as specified and as directed by Engr-in-Charge
M&L for plain cement concrete type B1, 1:2:4 (nominal mix) using 20mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and as directed by Engr-in-Charge
M& L for plain cement concrete type C2, 1:3:6 (nominal mix) using 40mm graded stone aggregate as in coping/collar of poles incl necessary form work complete all as specified and as directed by Engr-in-Charge
M&L for broken stone or boulders of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 150mm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in -Charge.
M & L for replacement of danger notice board of PVC sheet , printed with letters, figures ( English, Hindi, Tamil) and conventional skull and bones in signal red colour and fixed with GI. clamps, bolts and nuts of approved size, for LT/HT installations complete all as specified and as directed by Engr-in-Charge
M/S KHUSHICONSTRUCTION
A. R. ELECTRICALS
NAVJEEVAN ENTERPRISES
M/s Karbhagam Sales Agency
bansal construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .