Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC | ₹1.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 LRejected-AOC H NO 136 SUBHASH NAGAR TEHSIL CAMP PANIPAT HARYANA 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | ₹1.4 L | L2 | Rejected-AOC L2 |
| 3 | L3₹1.6 LRejected-AOC | ₹1.6 L | L3 | Rejected-AOC L3 |
Tender Value
₹1.6 L
EMD Value
₹3,100
Closing Date
19 Feb 2026, 5:00 pmClosed
Jagmal
DIV Panipat
Repair of sm Sector-11 Panipat
2026_HBC_502007_1
2026266523DE E9CD 4827 BC21 E021156574BC241HSV
Open Tender
Civil Works
30 days
Panipat
2 documents required · 2 mandatory
₹250
₹3,100
Yes
13 Mar 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
19 Feb 2026
11 Feb 2026
[11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand)
[11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand)
[21.93.2]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening
[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
[6.33.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
BOQ_580660.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid