Tender Value
Refer Docs
EMD Value
₹28,600
Closing Date
12 Jun 2026, 6:00 pmClosed
GE Jaipur
GE Jaipur
PROVN OF NURSING OFFICERS DUTY STATION ROOM AND HEAT STROKE ROOM AND CABIN FOR BLOOD COLLECTION ROOM AT MH JAIPUR
2026_MES_757458_2
GE/J- /2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Jaipur
As per Tender Documents
5 documents required · 5 mandatory
₹500
GE Jaipur
₹28,600
Yes
21 May 2026
21 May 2026
15 Jun 2026
21 May 2026
12 Jun 2026
30 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. | 4 | Cum | - | - |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and as directed. | 4.63 | Cum | - | - |
| 30 | Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-inCharge. The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. | 4.1 | Sqm | - | - |
| 60 | M&L for point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable, single core, 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light point controlled by one, one way switch 6 Amp complete all as specified and directed. | 17 | Point | - | - |
| 65 | M&L for point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable single core, 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one 3 pin, 15amp socket outlet on independent board complete all as specified and directed. | 3 | Point | - | - |
| 66 | M&L in repair for sub main wiring with two run | 70 | RM | - | - |
| 69 | S&F modular socket, 6 Amps, 2/3 pin combined, 2 module AC 240 volts complete all as specified and directed. | 9 | Each | - | - |
| 70 | S&F modular switch, 6 Amps, one way, 240 volts, 1 module complete all as specified and directed. | 33 | Each | - | - |
| 71 | S&F modular switch 16 Amps, one way, 240 volts, 1 module complete all as specified and directed. | 5 | Each | - | - |
| 72 | S&F modular socket, 6/16 Amps, 2/3pin combined, 2 module AC 240 volts complete all as specified and directed. | 5 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
BOQ_858949.xls
BOQ • 0.44 MB
Tender.pdf
Tender Documents • 1.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .