Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹42.9 L+₹92,775 (2.21%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹56.1 L+₹14.1 L (33.5%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹59.9 L+₹17.9 L (42.5%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
1 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt Pin-144005
Please refer tender documents
2022_MES_554160_1
8322/40/E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Jalandhar Cantt
Class D Category B(ii) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer East Jalandhar Cantt
₹98,000
Yes
17 Dec 2022
24 Sept 2022
8 Nov 2022
24 Sept 2022
1 Nov 2022
20 Oct 2022
Amount
Supply and fix in replacement Pin type insulator porcelain vitreous white brown or green incl one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nuts of size 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed.
Supply and fix in replacement of post insulator porcelain vitreous, white, brown or green suitable for Gang operated Air break switch 11000 volts including nuts, bolts with washer etc complete all as specified and directed. Make Jaipuria/ Rashtriya/Pactil
Dismantling insulators any type pin/disc/post type, any size from HT pole including opening of nuts, bolts complete for depositing the serviceable insulators to MES stores and unserviceable insulators for taking as per sch of credit complete.
Supply & fix new MS Cross arms, bracing, supports, clamps, anti climbing device and back plates fabricated from structural steel section including nuts, bolts, washers with reqd mech working/ process i.e. cutting, welding, bending, cold or hot, drilling holes, grinding or bolt in any shape or size including 2 coats of aluminium paint over one coat of red oxide including taking out unserviceable complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only.
Dismantling cross-arms of M.S. channel or angle sections etc. from HT poles by opening nuts, bolts complete and setting aside for re-use within 200mtr or depositing to GE (E) Jalandhar store yard as directed by Engr-in-charge.
Supply and fix in replacement lightening arrester expulsion type complete with all fittings, transmission class, discharge capacity 10 KA rupturing capacity conforming to IS suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, bracket etc and connecting with GI earth wire complete all as specified and directed.
Supply and fix in replacement stay assembly complete with 20mm dia, 1800mm (min) long GI stay rod with threaded ends and GI nuts with washer, two numbers thimbles MS clamps made out of 40mm x 6mm flat iron including MS nuts, bolts, washers and 300mm x 300mm x 6mm MS stay plate, stay bow of size 40 cm long 14 mm dia, loop type insulator including painting the exposed MS work with 2 coats of aluminium paint over a coat of red oxide primer complete all as shown in electrical plate No 1 (Earth work, concrete work, stay strand and clamps shall be measured and paid for separately).
M&L galvanised stay strand, size 7/4.0 mm complete all as specified and directed by Engineer-in-Charge.
Dismantling stay assembly incl demolition of concrete and opening of nuts, bolts complete all as directed by engineer in charge.
Supply and fix Danger notice plate for HT of 25 cm x 20 cm x 1.6 mm thick mild steel sheet vitreous enameled white, with letters, figures and conventional skull and bones and wtitten as "DANGER" in signal red colour and incl provn and fixed with MS clamps made out of MS flat 25 mm x 3mm , including nuts & bolts, including 2 coats of aluminium paint over a coat of red oxide primer including dismantling all as specified. Note :- Words shall be written in three languages viz. -Punjabi, Hindi and English.
M & L for male contact (moving contact blade) & female spring loaded contact(fixed contact jaw) made of gun metal phosphorus bronze with arcing horns suitable for GO switch continuous current rating 200 Amps, 11000 volts, including nut, bolts, washers etc and taking out unserviceable old fixed/moving jaw contact blade set complete.
Supplying and fix in replacement switch Air break Gang Operated DO Switch assembly (polymer insulators) outdoor type HT 11 KV triple pole, 400 Amps, vertical mounting type with fixed contacts and moving contacts of phosphorus bronze with mechnically operated from ground level with polymer insulator on steel frame incl suitable length GI pipe 25mm dia bore (medium grade) with handle and locking arrangment with 15 Nos polymer inuslators with drop out fuses tinned copper flexible jumper complete including taking out old unserviceable GO DO Switch all as specified and directed by Engineer-in-charge and (clamps/cross arms shall be measured and paid for separately). Make Jaipuria/ Rashtriya/PACTIL/OBLUM
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified.
Supply and Fixing Cable Jointing Kit for 11 KV grade earthed cable for indoor type termination cold shrinkable joint complete with jointing material, thimble and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 95 sqm to 120 sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete.
All as per item No. 14 here-in before but of size 150 to 185 sqmm 3 core
All as per item No. 14 here-in before but of size 240 Sqmm to 300 sqmm 3 core.
Supply and fixing Cable Jointing Kit for 11 KV grade earthed cable for outdoor type end termination cold shrinkable joint complete with jointing material and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 95 sqmm to 120 Sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete.
All as per item No. 17 here-in before but of size 150 Sqmm to 185 sqmm 3 core
All as per item No. 17 here-in before but of size 240 sqmm to 300 sqmm 3 core.
Supply and fixing Cable Jointing Kit for 11 KV grade earthed cable for straight through cold shrinkable joint complete with jointing material and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 95 sqmm to 120 Sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete.
All as per item No. 20 here-in before but of size 150 sqmm to 185 sqmm 3 core.
All as per item No. 20 here-in before but of size 240 Sqmm to 300 sqmm 3 core. Note for Ser item no 14 to 22 :-(i) The rate quoted include any type of Excavation, earth work for taking out loop and returning, filling in any type of soil complete. (ii) The contractor has to arrange min 50% qty of the items for Srl item No 14 to 22 within 20 days of start of work and shall be handed over to concerned JE E/M to ensure availability without fail at any time. (iii) A penalty of Rs 1000/- per day shall be levied, if supply fails due to non availability/ non handing over of these items.
Material & Labour for PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric pole, etc. including use and waste of necessary form work and fare finish to exposed surfaces without using extra cement etc. complete all as specified.
Supply, installation, testing and commissioning 3 Phase, 3 Limb, Dry type Resin cast Potential transformer suitable for compact sub station/ VCB/RMU with ratio 11KV/rt3/110V/rt3, burden 100 VA, class 0.5, of size as per existing complete with fixing arrangement and necessary connections all as specified and directed
Supply, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade earthed system of size 185 Sqmm 3 core conforming to IS-7098 (Part-II) 1985 laid in trenches, in floor, in duct, through pipes or along the pole including taking out unserviceable HT overhead conductor/cable complete all as specified and directed
Ditto as per item No 25 above but of size 120 sqmm 3 core
Ditto as per item No 25 above but of size 300 sqmm 3 core Note: (i) Excavation & earth work, sand cushioning, brick protection cover/ GI protection pipe including clamps shall be measured and paid for separately. (ii) The qty of cable will be executed as per direction of Engr-in-charge as per requirement i.e. short/ long in any type of length.
Testing of 11 KV protection (overload and earth fault) relays through current injection system including current setting and time setting i.e long time pick up, short time pick up, inst. pick up, G.F. pick up values and corresponding time test and other required test values as per site requirement at 11 KV Sub Stn at different location complete all as directed by Engr-in-Charge. Note: (i) The rate quoted include cost of any machinery, T&P skilled manpower/ Engineer charges. The contractor shall have to submit written report from the reputed manufacturer/ OEM (make to be approved by deptt) after carrying out the testing. The overall qty may be executed at different times during currency of work.
M & L for boring hole under the road / pavement / hard standing of any width with the help of trenchless technology using ultra sound technique and necessary machine and including HDPE pipe 150 mm of size not less than one metre below ground level complete all as specified & directed by Engineer-in-charge.
M & L for PCC work (1:3:6) type C-2 using 40 mm graded mechanically crushed stone aggregate as in foundation of stay / coping of poles including necessary form work and fare finish to exposed surfaces without using extra cement etc. complete all as specified.
Supply and fix galvanised pipe light grade of IS marked 100 mm bore for passing of cable fixed to poles/walls/laid under floor/road complete with and including fittings as required including taking out unserviceable pipe complete all as specified and directed by Engr-in-charge. Make Ravindra/ Jindal/ TATA/OSWAL/PRAKASH SURYA.
Ditto as per item No 31 above but of size 80 mm bore.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables incl taking out old PCC cover and stacking for re-use and getting out soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches and punned down to thickness of 18cm complete all as specified. Note: The punned down thickness of 18 cm will be measured.
Supply & laying un-reinforced precast concrete cable cover, class HVP, type I, flat, size 300mm x 180mm x 40mm laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.
Relaying of existing retrieved bricks/PCC cover laid in trenches for cable protection perpendicular to the direction of cable length, adjacent abutting each other complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm upto test point and incl Aluminium strip 25x3.15mm from test point to equipment and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate with 1 nos MS handles of 8mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified.
All as per item No 39 above but for earthing using GI wire of 4 mm dia as earth lead in 15 mm bore protection pipe complete all as specified and directed..
S & F 25 mm x 3 mm aluminum strip as earth continuity conductor including from test point to equipement complete all as speicified & directed by Engineer-in-charge.
M & L for preperation of old painted surface of PCC HT poles and applying two coats of synthetic enamel paint in alternate yellow & black strips of 30 cm each up to 1.5 mtr height from top of PCC coping and numbering of poles and writing 'MES' complete all as specified & directed by Engineer-in-charge
Labour only for cutting / Pruning of tree branches 2.0 mtr all around the HT 4 Pole structure / 2 pole structure / plinth mounted transformer/PSS/ overhead Joints & removing the branches to a distance not exceeding 200 mtrs to the entire satisfaction of Engineer-in-Charge.
Supply & fix in replacement of strip heater 80 watt in existing RMUs/ VCBs including taking out unsv heaters complete all as specified.
Material and labour for fixing cable route indicators made of PCC (1:3:6) duly engraved “HT CABLE / HT JOINT” coloured with two coats of synthetic paint in brown or other approved colour of size 150 x 150 x 900 mm fixed 300mm below ground level all as specified and directed.
Supply and fix in replacement DMC insulator of size 30 x 6 mm for earthing strip/wire on pole/wall as specified and directed.
Supply, installation, testing and commissioning of Dry type Resin cast current transformer (CT) having ratio 200-100/1 A, burden 2.5 VA, class 1, STC 21 KA for 3 sec of size and shape as per existing suitable for RMU/ VCBs complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB/PRAGATI/AS PER EXISTING MAKE
Supply, installation, testing and commissioning of Dry type Resin cast current transformer (CT) having ratio 200-100/5-1 A, burden 1 VA, 5P10, STC 21 KA for 3 sec of size and shape as per existing suitable for RMU/ VCBs complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB/PRAGATI/AS PER EXISTING MAKE
Cutting and cleaning of grass, bushes, branches upto 5 Mtr X 5 Mtr area by using manually/cutter machine all around and suitable chemical near Package Sub Stations , Ring main Units and 4 pole /2 pole structure area complete all as specified & directed by Engineer in charge .
S&F in glow sign board of size 3.0 Mtr x 0.8 Mtr x 25cm made of aluminium sheet 2mm thick with frame of stainless steel with UV printing on star flex in blue and white colour with 04 Nos of 09 Watt LED fitting 2 feet complete all as specified and directed.
Cleaning and preparation of old painted surface of 4 pole structure and painting with one coat of aluminium paint to all steel poles, structure such as channel/brackets, bracing, clamps, anti climbing device, cross arms and further painting 30 cm high alternate yellow & black strips with synthetic enamelled paint upto 1.5 mtr height complete all as specified and directed.
M&L removing of heavy tree branches near transformer, Compact sub station, sub stn building or near 4 pole structure or LT/HT line with help of crane all as specified and directed by Engineer in charge.
M&L for shifting of VCB installed in indoor sub stations after taking proper shut down and disconnecting existing HT connections/ feeders and shifting with help of crane and reqd manpower carefully and depositing to MES Yard complete all as specified and directed.
M & L for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE HT underground power cables of the rating 11 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of faut location necessary excavation and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar cantt all as specified and directed. Note: The joint shall be measured and paid separately under relevant item. The qty of item will be executed at different times during currency of contract as directed by Engr-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly.
Excavation in post holes (or similar holes ) each in not exc 0.5 cum getting out returning filling in an ramming earth or broken rubble mixed surplus soil out of land and making good surface all as specified and directed.
PCC (1:3:6) type B-1 using 20 mm graded stone aggregate filling in post holes foundation ,surface channelsand drains and other similar work all as specified and directed
S&F mild steel work as in posts and struts in fencing including cutting, tops to shape as directed, drilling holes, notching for wirefencing / chain link fencing etc. flat iron fillets (for securing chain link fencing etc.) including all necessary drilling, bolting orreveting ,welding, etc. and similar embeding in concret and securing etcand work conforming to Fe-290 Gde E-165 including painting two coat of synthetic enamel paint over a coat of primer all as directed.
Material and labour PVC coated chain link fencing 10 gauge thick galvanised steel wire and 50mm x 50mm size mesh fixed to steel fencing post by galvanized iron nut bolt etc including provision of binding wire complete all as specified and directed and chain link approved by GE.
S&F structural framed work as in doors or gates of angle or other section with gusset plates, rails,bracesetc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with end incl either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing confirming to Fe 410-W (Gde-E-250) quality A, complete including two coats of synethic enamel paint over a coat red oxide primer all as directed
Material and labour for brick work sub class B old size bricks straight or cured in plan n. exe. 6.0M mean radius built in cement mortor 1:4 all as specified
Material and labour 15mm thick cement plaster in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour 100mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
M&L for 60mm thick precast cement concrete (M-35) factory made, machine pressed interlocking paver blocks, with grey cement and pigment any shape and size as approved by GE, laid over sand cushion complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description & in any position not otherwise specifically provided for complete all as directed
M&L for MS TMT bars 10 mm and over dia and cut to lenth, bent to shape required incl cranking bending spirally for hooping for clos hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia.
Taking down/ out old HT cable off sizes from trench & pole including disconnecting all electrical connections and depositing serviceable length/portion of cable in MES store yard for Re-use at same or other site and removing unserviceable lenght/portion of cable after cutting from site to take credit. . Note: (i) Unsv HT Cable shall be given to contractor as per schedule of credit and serviceable shall be used for re laying. (ii) A penalty of Rs 1000/- per RM shall be recovered from contractor, if any damage to cable made by negligence on contractor part during taking out/ shifting etc
Shifting of retrieved serviceable cable from item Sr No 66 in any length reqd and as directed by deptt full length or after cutting in reqd length complete collecting from store to reqd site and Relaying of 11 KV HT Cable off size carefully at different route/ different location in trench including connecting to existing/new system incl testing, commissioning complete all as specified and directed by Engineer-in-Charge.
Servicing of ring main unit (RMU) 3/5 way 11 KV by taking shut down and disconnecting electrical connections, removing of dust with blower, cleaning of all movable/fixed parts, removing moisture/ hard carbon deposited due to flash over on bus bars and insulators with CRC/ Stanvac moisture/ carbon remover, checking all components, insulators/ studs, adjusting the male / female bushings in proper spacing, lubrication of moving parts, greasing all parts, tightening nuts and bolts, testing of CT & PT with injection kit and reconnecting of all electrical connections, testing of RMU for healthiness and proper functioning and submitting report complete all as directed. Note: The Servicing/ testing shall be done by authorised and expert service engineer from manufacturer or channel partner. Contractor shall submit complete report regarding CT & PT, Protection relay functioning pick up current & corresponding time value setting 7 tests carried with injection testing kit, Relay testing kit. Any major Spare replaced shall be measured and paid seperately.
Material and labour for replacement of Load break switch assy, rating 12 KV, 630 Amp, STC 21 KA for 3 sec for RMU 11KV suitable for existing model of make Schneider/ Siemens/AREVA complete testing all as specified and directed by Engr-in-Charge
Material and labour in replacement of hydraulic shocker for closing and opening of main cubicle door suitable for 11KV RMU 3/5 way of series FBX2025/FBX1844 of Schneider or other installed make complete all as specified and directed.
Material and labour for SF6 Gas pressure indicator gauge suitable for KV RMU 3/5 way complete.
Material and labour for Voltage Presence Indication system complete with connected accessories for existing RMU 11 KV 3/5 way complete all as specifed and directed.
Material and labour for Digital voltmeter 0-15KV, PTR 11KV/110V, CL 1.0 complete with necessary connections and replacement of internal wiring incl removing old unserviceable all as directed.
Material and labour for Digital ammeter 96x96mm suitable to work on Cl 1.0 having CT ratio as per existing ammeter complete with necessary connections and replacement of internal wiring incl removing old unserviceable all as directed.
Material and labour for thermostat for space heater of HT panel/ VCB/RMU complete as specified and directed by Engr-in-Charge.
Material and labour for tripping coil of 110V AC/ DC as reqd at site for 11KV RMU 3/5 way of series FBX2025/FBX1844 or existing VCB/ SF6 breaker 11/66KV complete all as specified and directed by Engr-in-Charge.
Material and labour for closing coil of 110V AC/ DC as reqd at site for 11KV RMU 3/5 way of series FBX2025/FBX1844 or existing VCB/ SF6 breaker 11/66KV complete with necessary connections all as directed.
Material and labour for closing coil of 220V AC/ DC as reqd at site for 11KV RMU 3/5 way of series FBX2025/FBX1844 or existing VCB/ SF6 breaker 11/66KV complete with necessary connections all as directed.
Material and labour for tripping coil of 220V AC/ DC as reqd at site for 11KV RMU 3/5 way of series FBX2025/FBX1844 or existing VCB/ SF6 breaker 11/66KV complete all as specified and directed by Engr-in-Charge.
Material and labour for Insulated cable termination boot kit for HT cable connections in 11KV RMU 3/5 way complete all as specified and directed.
Material and labour for digital voltmeter for 11 KV RMU 3/5 way of series FBX2025/FBX1844 complete with necessary connections.
Material and labour for batteries suitable to 11KV RMU 3/5 way of series FBX2025/FBX1844 operation for relay/motorization circuit
Material and labour for charging of SF6 gas 11KV RMU 3/5 way at site complete. .
Material and labour for replacement of spring charging motor of suitable AC/DC voltage rating for 11KV RMU 3/5 way of series FBX2025/FBX1844 or VCB existing at site complete all as specified
M&L for power pack with capacitor back up suitable of VCB 11KV 630/800/1200 Amp working on 110V/230V AC and outpur 24V DC, Capacity 100 watt complete all as specified
Supply and fix in replacement AB3 control card for 11KV RMU 3/5 way of series FBX2025/FBX1844 motorization circuit all as specified and directed.
Supply and fix copper tinned fuse wire of 16/17/18 SWG size all as specified and directed
Servicing & maintenace to CR panel complete by tightening all connections, replacing Trip & Non trip alarm, repair/replacement to defective parts of Annuciator system 16 window complete, replacing of frequency meter incl checking functioning of differential, feeder relay complete all as specified and directed
Material and labour for servicing & testing of Vaccum circuit breaker/control panel including CT, PT and relays in control panel of VCB of capacity 1250 /800/630 Amps and rating 11 KV complete as details mentioned as under and submitting written test report for testing complete:-
(a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust, dirt & carbon deposits. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required. (xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor
(b) The following test shall be carried out:- (i) Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance.
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (d) Testing of followig Aux relay (i) DC Supply supervision relay. (ii) Master trip relay
M&L for replacement of Master trip relay 24V/110V/220V DC suitable for existing 11KV VCB complete.
M&L for trivector meter bi-directional type suitable for 11KV/rt3/110V/rt3, class 0.2s, -/5A complete with necessary connections all as specified and directed.
S&F LED indication lamp for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B etc or other function for 66KV CR Panel/ 11 KV control panel VCB/ PSS/CSS and associated wiring, if reqd, including taking down old UNSV LED indication complete all as specified and directed
M&L for demand controller relay suitable for KV VCB at MRS complete with necessary wiring and connections complete all as specified and directed. Make : L&T/Schneider/ABB/Siemens
M & L for resin cast current transformer of ratio 50-25/1 A, burden 2.5 VA, class 1, STC 21 KA for 3 sec suitable for VCBs of size and shape as per existing one complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB
M & L for resin cast current transformer of ratio 30/1 A, burden 2.5 VA, class 1, STC 21 KA for 3 sec suitable for PSS complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB
M & L for current transformer of ratio 30/1 A, burden 1 VA, class 10PS suitable for PSS of size and shape as per existing complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB
Supply and fix in replacement Digital Multifunction Transducer/Meter (Accuracy class 0.5) with LCD/LED display for measurement of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc including associated wiring using 1.5 Sqmm FRLS copper wire for 11KV VCB complete all as specified and directed.
S&F VRLA battery cell 2 volts,100 AH, maint free with suitable size of sleeved strip for interconnections, initialy charging, commissioning and testing complete including taking down old UNSV battery from battery bank system complete all as specified and directed
S&F battery cell 2 volts, 200 AH, dry type with suitable size of copper strip for interconnections, initialy charging, commissioning and testing complete including taking down old UNSV battery from battery bank system complete all as specified and directed
M&L for periodical servicing, calibration on of HT 11 KV Automatic power factor control (APFC) Capacitor bank panel with incoming VCB of 3200 KVAR installed at 66 KV MRS by service engineer of make Schneider/ OEM for complete health check up of panel incl visual examination, cleaning, checking for insulation resistance test, testing of efficacy of discharge device, reactors , test for capacitance and output, manual and auto operation incl, checking protection fuse, control service voltage, CT & PT, capacitor bank control relay, trip relay, vacuum interrupter and contacts and tightening of loose connetions incl submission of inspection report by service Engineer of OEM complete all as specified.
M&L for HT 11KV capacitor bank 3200 kVAR controlling relay suitable to start/ energize the cap banks step wise in auto mode as per requirement and to discharge / starting of reactors with necessary electric connections comlete all as directed.
M&L for repair of RMU 11 KV 3/5 way any type & any make (Schneider, Siemens, Areva, Hartek or any other make) complete including removing/ disconnecting electric cable and earth connections from RMU, shifting the RMU through suitable transport to OEM/ authorized manufacturer/ service centre workshop at Chandigarh/ Delhi and opening / step opening of RMU parts and diagnosing the fault complete including making necessary repairs, replacing complete defective AC & DC circuit control protection wiring, complete cleaning, servicing and replacing major defective parts and re-fixing, necessary repairs to gas chamber, vaccumizing and SF 6 gas filling, assembling and replcing parts for satisfactory functioning and shifting back to Jalandhar cantt and installation, commissioning and making electrical connections complete all as directed. The major spares replaced shall be measured under relevant items of Sch.
M&L for Support insulator suitable for 12 KV RMU
M&L for HT bushing from side RMU/ SF6 gas chamber incl refilling of gas after fixing HT bushing
M&L for Extensibility kit complee with 3 No Extension connectors & 3 Nos Adaptors
M&L for HT Electric fuse for RMU upto 12KV
M&L for earth switch assy for RMU
M&L for load break switch assy 12KV for RMU
Vaccum circuit break switch 12 KV for RMU
M&L for battery 12V, 20 Ah min for RMU
battery charger 12V/24V for RMU as per existing one
M & L for current transformer having ratio 400-200-100/1-1-1A, core 1 class 0.5, burden 2.5 VA, core 2.5P, 2.5 VA and core 3 PS, STC 21 KA for 3 sec suitable for RMU/VCBs complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB/as per existing marke
M & L for current transformer having ratio 400-200-100/1-1A, core 1 burden 2.5 VA, class 0.5, and core 2, burden 2.5VA and class 5P10 STC 21 KA for 3 sec suitable for RMU/VCBs complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB/as per existing marke
M&L for Self powered relay DPX1_V3 suitable for operation of Compact sub station. Make Schneider or equivalent in Crompton Greaves/ ABB
M & L for current transformer having ratio 200-100/5/1 A, burden 2.5 VA, class 1, STC 21 KA for 3 sec suitable for VCBs complete all as specified and directed by Engineer-in-Charge. Make Schneider/ Crompton Greaves/ ABB
M&L for auxiliary transformer suitable for RMU/PSS of ratio 11KV/230V , burden 1KVA, class 5P , ILV 12kV/28kV/75kVP of shape and size as existing complete all as specified and directed.
M&L for Replacement of Hooter/Siren suitable fro VCB & CR panel as per existing complete all as specified and directed.
M&L for maintenance free battery 12V, 180 Ah complete all as specified and directed.
M&L for frequency meter suitable for 66 KV CR panel complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 volts grade earthed system of size 95 Sqmm 3 core conforming to IS-7098 (Part-II) 1985 laid in trenches, in floor, in duct, through pipes or along the pole including taking out unserviceable HT overhead conductor complete all as specified and directed
M&L for prestressed concrete pole 11 metre long, 152mm x 152mm at top and 152 mm x 260mm at bottom class 9 complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and exceeding 1.50 mtr in depth for laying of cables incl taking out old PCC cover and stacking for re-use and getting out soil complete all as specified and directed by Engineer-in-Charge.
M&L for HT jumper made of XLPE insulated aluminium conductor of length 1 metre long with crimped thimbles at both ends complete fixing on 2 pole/ 4 pole structure as reqd at site.
M&L for HT jumper made of XLPE insulated aluminium conductor of length 2 metre long with crimped thimbles at both ends complete fixing on 2 pole/ 4 pole structure as reqd at site.
M&L for replacing DC supply wiring of size 1.5 Sqmm with 2 run for VCB, RMU complete for detecting fault in DC supply and replacing with new one upto 30 Mtr length complete all as specified and directed.
Shree Balaji Construction
AGGARWAL ENGINEERING CO
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .