Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC 12 53 CHOPASNI HOUSING BOARD JODHPUR 342008 | JODHPUR | RAJASTHAN | 342008 | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.7 L+₹5.8 L (22.3%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹34.6 L+₹8.7 L (33.7%)Rejected-Finance 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.3 L+₹9.4 L (36.1%)Rejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹35.7 L+₹9.8 L (37.7%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹41.8 L
EMD Value
₹83,700
Closing Date
29 Jun 2023, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer (Raj) 344001
SPECIAL REPAIRS / RENOVATION AND REWIRING OF ELECTRICITY FITTING OF SCHOOL BUILDING IN KV SCHOOL UTARLAI
2023_MES_590612_3
8403/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹83,700
Yes
31 Aug 2023
8 Jun 2023
1 Jul 2023
8 Jun 2023
29 Jun 2023
15 Jun 2023
Amount
Taking down old unserviceable perished point wiring for light/fan /socket/power with all fittings and fixtures, tube lights complete including making good the disturbed surfaces complete all as specified and as directed.
M&L for Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded FRLS flexible copper conductor cable drawn in and incl rigid PVC conduit concealed with pressed mild steel terminal boxes duly painted with a coat of red oxide primer fixed flushed to the wall with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire to common earth dolly, including cutting chases in brick/ block/stone masonry wall , replastering and making good to match the existing specifications complete all as specified and directed by Engr-in-charge. Note: a) Unit rate include for cutting chases for conduits and sunken boxes and making good to wall, floors etc
All as per Item No 2 above but for one ceiling fan/exhaust fan point controlled by one switch complete all as specified and directed.
All as per Item No 2 above but for one 5 Amps socket point controlled by switch on the same board with other switches complete all as specified and directed.
All as per Item No 2 above but for one 5 Amps socket point on independent board.
M&L for point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with pressed steel terminal boxes of adequate size fixed flushed to the wall with 3mm thickness plastic laminated sheet cover for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, including cutting chases in brick wall, replastering and making good to match the existing specificationscomplete all as specified. Note: a) Unit rate include for cutting chases for conduits and sunken boxes and making good to wall, floors etc.
S&f switch 5 Amps piano flush type single pole one way complete all as specified and directed.
S&f switch socket combination flush type 5 Amps, 2/3 pin multipurpose complete all as specified and directed.
S&f switch socket combination flush type 5/15 Amps 3/5 pin universal multipurpose complete all as specified and directed.
S&F socket outlet flush type 2/3 pin 5 Amps complete all as specified and directed.
S&f ceiling rose surface bakelite 65mm three terminal complete all as specified and directed.
S&f stepped type electronic fan regulator flush type on the 80 watts two module complete all as specified and directed.
S&f lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement LED bulb of capacity 9 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
S & F LED light fittings 18/20W, 230V, 4 feet (not less than 120 lumen/watt), complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
M&L for submain wiring with 2 runs of 4.0 sqmm single core PVC insulated (FRLSH) stranded copper conductor cable drawn through concealed PVC conduit on walls/ceilings with one run of 4.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections including taking down old unserviceable submain wiring of any size along with MS conduit /PVC conduit/PVC casing caping and making good the disturbed surfaces upto the satisfaction of Engr-in-charge complete all as specified and directed. Note: 2 runs of 4.0 Sqmm PVC insulated unsheathed copper conductor and 1 run of 4.0 Sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run.
S & F LED street light 20 W IP 66, with aluminium pressure die cast housing, toughened glass in the front with all accessories internally pre-wired complete all as specified and directed.
M&L in replacement bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required, fixed with and including MS flat iron 25x3mm, clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed.
S&F in repair sheet metal enclosures single pole and neutral 8 way, 240 volts with 200 Amps rated bus bar with double fixed on flush to the wall including making the hole in the wall and fixing the DB including cement works and plastering complete all as specified and directed.
S&F in repair sheet metal enclosures MCCBs DB TPN 4 way having one No. MCCB 4 Pole 100 AMP as incomer, 415 Volts with 200 Amps rated bus bar with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete all as specified and directed.
S&F MCBs TPN, 240 volts 63 Amps, 10 KA B curve complete all as specified and directed.
S&F MCBs DP, 240 Volts 6 to 32 Amps, 10 KA B curve complete all as specified and directed.
S&F MCB single pole, 240 volts 6 to 32 Amps capacity, 10 KA B curve complete all as specified and directed.
M&L for earthing complete with 600x600x6mm thick GI earth plate electrode buried directly in ground not less than 2.25mtr below GL with the top edge of the plate at a depth not less than 1.5 mtr from GL connected to GI earth lead of 4mm dia by means of nuts, bolts, washers, checknuts etc made out of galvanised iron or steel, earth wire protected by galvanised iron pipe, connected to main switch board complete including necessary earth work excavation, PCC chamber, watering pipe, funnel, wiremesh, RCC chamber cover etc complete all as specified as per SSR Part-I plate No. 3 and directed.
Taking down ceiling fan ,exhaust fan, dismantling blades and should be kept safe custody in store complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable 3 core copper multi stranded PVC insulated 0.75 Sqmm from ceiling rose or connector to fan complete all as specified and directed.
S & F Single pole and neutral metal enclosure with a two pin and socket complete with space for one SPN MCB 240 volts complete all as directed by Engr-in-Charge.
Supply, laying and testing 16 Sqmm 4 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down old cable complete all as specified and directed.
Supply, laying and testing 25 sqmm 4 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down old cable complete all as specified and directed.
Supply, laying and testing 120 Sqmm 3.5 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down old cable complete all as specified and directed.
Design supply installation and testing of evaporative cooler 2000 CFM (Room size 24" (L) x 20" (B) x 11.5" (H) approx) 20 Nos air charges per hours made out of GI sheet with all necessary supporting items required to achieve the flow & installation cooler should withstand wind speed out 160 km/hour and noise level at room not more than 70 db. The flow of air from cooler to room should by provide by the GI sheet ducting with suitable size of lining & insulation and have proper number of opening at entrance of the classroom including making hole in wall for ducting & lowers. Cooler shall be installed at the roof of the bldg and ducting from cooler to room will be done by proper splitting of the duct (thickness and size of duct should be as per SMACNA) with all necessary fixing arrangement required at site.
Note:- Cost of following is deemed to be included in the quoted rate of item No. 32 1. Cooler should be placed 30 cm above the ground of roof by making PCC hollow platform of suitable size. 2. All motor/ pump should be latest energy efficient and of proper size as per IS and approved by Engr-in-charge. 3. The cooler tank should have the capacity to store water for working upto 4 hours. 4. An additional tank rotational moulded PVC double layers ISI marked of 500 Itrs capacity should be in line with the tank of cooler to keep the water in reservoir (Cost of PVC tank including float valve, connections etc). 5. Cost for the tapping water connection to the tank from existing ground main pipe line & tank to cooler should done by suitable size GI tubing. 6. Cost for all necessary electrical connecting of suitable size wire as per IS standard by providing 3 phase industrial type sheet metal socket plug & top. 7. Cost of grove cutting in wall for ducting & louver and make up with existing surface.
Supply install and testing commisioning of wall mounted fan with swing of 300mm size all as specified and directed by Engineer-In-Charge.
Supply install and testing commisioning of ceiling fan 1200mm sweep complete all as specified, directed and approved by Engineer-In-Charge.
Supply & fix exhaust fan AC single phase 230/ 240 V of size 300 mm sweep, 1400 RPM including fixing of louvers 300 mm dia by using suitable fastener grouted in the wall, including PVC copper cable 1.0 Sqmm 3 core connecting from ceiling rose to exhaust fan including cutting holes into bricks/block /stone masonary and making good dismental portion all as specified and directed by Engineer-In-Charge.
Supply fixing and installing of Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom,class 10 complete all as specified and directed by Engr-In-charge.
Supply and fix orion Neo LED street light of 70 Watt made up of pressure die cast aluminium housing with ploycarbonate cover and high power LEDs and secondary lenses with IP 66 protection 10KV SPD included. Efficiency >110 LPW and including junction box and PVC wire 2 core for connections from street light to junction box complete all as specified and directed.
Supply and fix LED flood light 80 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection system efficiency >110/125 LPW, 10KV SPD included complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Excavating in trenches n. exc 1.5m wide and n exc 1.5 mtr in depth for laying cables/pipe line etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed.
Removing excavated materials to a distance n.exc 50mtr and depositing where directed at a level nexc 1.5mtr above the starting point complete all as specified and directed.
M&L for providing tibba sand in trenches as sand cushioning to U/G cable including punning down of sand in layer complete all as specified and directed.
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab cover 25 to 30cm wide and 40 to 50 cm in length laid dry abutting each other complete all as specified and directed.
Cutting of existing road/PCC n.exc 20cm wide and n.exc 30cm in depth for laying protecting pipe line etc and removing the debris n.exc 50m and filling with PCC 1:2:4 over the protection pipe complete all as specified and directed.
Supply and lay GI pipe 50mm dia, light grade ISI mark with all fittings laid in trenches, fixing in wall and pole including suitable GI clamps for bracing the pipe with pole for cable protection complete all as specified and as directed.
Material and labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregates ) as in foundation filling and mass concrete complete all as specified and direcetd.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate for foundation and coping complete all as specified and directed
M/S PRASHANT BENIWAL
new india engineers
M/S Tanisha Traders
M/s Malinath Electricals
Lalit and Brothers
M/s Shiv Builder and Suppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .