Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | ₹29.4 L Quoted ₹30 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹35.4 LRejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYAN PURI EAST DELHI DELHI 110091 UDYAM DL 02 0083384 | EAST DELHI | DELHI | 110091 | ₹35.4 L | L2 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | M/S G S Gupta and Sons L1 | Bharat Sales Corporation L2 |
|---|---|---|---|---|---|
| 1.00 | Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to emergent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc.. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed.
Notes :- This item is applicable only where no store is required. 1. The site for attending complaints at DGQA Area, ASC deopt, Napier Rd, Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830 hrs to 1700 Hrs including holiday and Sunday. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after. | 650 | Each Job | 120 ₹78,000 | 100 ₹65,000 |
| 2.00 | Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm complete all as specified and directed. | 200 | RM | 20 ₹4,000 | 35 ₹7,000 |
| 3.00 | All as per item No 2 above but size 2.5 Sqmm complete all as specified and directed. | 200 | RM | 30 ₹6,000 | 20 ₹4,000 |
| 4.00 | All as per item No 2 above but size 4 Sqmm complete all as specified and directed. | 200 | RM | 48 ₹9,600 | 60 ₹12,000 |
| 5.00 | All as per item No 2 above but size 6 Sqmm complete all as specified and directed. | 100 | RM | 73 ₹7,300 | 80 ₹8,000 |
| 6.00 | All as per item No 2 above but size 10 Sqmm complete all as specified and directed. | 100 | RM | 96 ₹9,600 | 100 ₹10,000 |
| 7.00 | M&L for switch piano flush button single pole one way 5 amps 240 volts complete all as specified and directed. | 650 | Each | 21 ₹13,650 | 20 ₹13,000 |
| 8.00 | M&L for switch piano flush button single pole one way 15 amps 230 Volts complete all as specified and directed. | 200 | Each | 65 ₹13,000 | 60 ₹12,000 |
| 9.00 | M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed. | 226 | Each | 40 ₹9,040 | 35 ₹7,910 |
| 10.00 | M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts complete all as specified and directed. | 200 | Each | 75 ₹15,000 | 90 ₹18,000 |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Nov 2025, 6:00 pmClosed
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF INTERNAL ELECTRIFICATION FULLY AND FIXTURES AND COMPREHENSIVE MAINT PETTY REPAIRS AND DAY TO DAY COMPLAINTS INCLUDING REPAIR/MAINT OF CEILING FAN, EXHAUST FAN, WMF GEYSERS, SPLIT AC/WINDOW AC, DESERT COOLER AND DEEP FREEZER
2025_MES_736615_1
GE(I)/KAN/T-45 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹80,000
Yes
7 Feb 2026
24 Oct 2025
3 Dec 2025
24 Oct 2025
26 Nov 2025
7 Nov 2025
Amount
Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to emergent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc.. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints at DGQA Area, ASC deopt, Napier Rd, Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830 hrs to 1700 Hrs including holiday and Sunday. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm complete all as specified and directed.
All as per item No 2 above but size 2.5 Sqmm complete all as specified and directed.
All as per item No 2 above but size 4 Sqmm complete all as specified and directed.
All as per item No 2 above but size 6 Sqmm complete all as specified and directed.
All as per item No 2 above but size 10 Sqmm complete all as specified and directed.
M&L for switch piano flush button single pole one way 5 amps 240 volts complete all as specified and directed.
M&L for switch piano flush button single pole one way 15 amps 230 Volts complete all as specified and directed.
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts complete all as specified and directed.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts complete all as specified and directed.
M&L for switch modular type one way 1 module 16 amps 230 Volts complete all as specified and directed.
M&L for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts complete all as specified and directed.
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts complete all as specified and directed.
S&F modular white cover plate with frame 2/3 module complete all as specified and directed.
S&F modular white cover plate with frame 4 module complete all as specified and directed.
S&F modular white cover plate with frame 6 module complete all as specified and directed.
S&F imodular white cover plate with frame 8 module complete all as specified and directed.
S&F modular white cover plate with frame 12 module complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
S&F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
Supply and fixing in replacement step type hum free electronic fan regulator suitable to control speed of fan from 0 to 100% and connecting electrically all as required complete all as specified and directed.
Supply and fixing in replacement modular regulator all as required complete all as specified and directed.
Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts complete all as specified and directed.
Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts complete all as specified and directed.
Supply & fix in replacement hylem sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and directed.
All as per item No 26 above but of size 8"x10" complete all as specified and directed.
All as per item No 26 above but of size 11"x9" complete all as specified and directed.
All as per item No 26 above but of size 13"x11" complete all as specified and directed.
S&F in repair sunken box size 3"x5" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 4"x7" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 7"x9" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts with one single pole MCB of 25 amps earthing complete all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
All as per item No 34 above but for 8 way complete all as specified and directed.
M&L for MCB single pole 240 volts 6 to 32 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
S&F MCB SP 63 Amps with rupturing capacity10 KA, 'C' Series complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 40 amps,with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 63 amps,with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed.
S&F MCCB 125 Amps capacity, 4 pole, 16 KA, fixed thermal and magnetic release with extended terminals to be fixed in 8 way TPN DB complete all as specified and directed.
All as per item No. 40 above but capacity 100 Amps, fixed thermal and magnetic release, 4 Pole, 16 KA suitable to be fixed in 4 way TPN DB complete all as specified and directed.
Supply and fixing 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast PVC housing for better heat decapitation. P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as specified and directed.
Supply and fixing in repair surface and wall mounted LED Tube light & fitting 20 watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with provision PVC copper wire 1.5 sq mm 3 core of required length upto ceiling rose complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted 36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making electrical connection with making electrical connection with three core copper wire to ceiling rose properly complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted 31/32 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making making electrical connection with making electrical connection with three core copper wire to ceiling rose properly complete all as specified and directed.
M&L for Surface mounted LED down lighter 12 watts with white powder coated polyconbonate housing and pressure die cast heat sink having high efficiancy complete all as specified and directed.
S&F in replacement of LED post top globestarmade up of unbreakable polycarcarbonate suitable for mounting on gate with led bulb 12 W with proper arrangements and making electrical connection complete all as specified and directed.
S&F LED bulb of 9 watt, 240 V 50 Hz complete all as specified and directed.
Supply and fix LED invertor bulb 15 watt, 240 V 50 Hz complete all as specified and directed.
S&F distribution board iron clad, double door with IP-43 1K-09 protection(VTPN) suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way with appropriate size copper bus bar and neutral link, confirming with provn of one MCCB 4 pole 415 Volts & MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with box complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with box complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 A flush types complete all as specified and directed.
S&F Switch socket combination 2 in 1, 15 A flush types complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through existing concealed conduit in / on wall/ceiling with provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for following:- a). One light point controlled by one 05 Amps switch.
All as per item No. 56 above but One fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 56 above but One socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including concealed conduit in / on wall/ceiling with provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dully for following:- a). One light point controlled by one 05 Amps switch.
All as per item No. 59 above but One fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 59 above but One socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No. 59 above but One socket out multi pin 5 Amps controlled by one switch on same board complete all as specified and directed.
All as per item No. 59 above but One calling bell controlled by one bell push complete all as specified and directed.
All as per item No. 59 above but for one socket out let 2 in 1, 5 and 15 Amps or AC point with 4 Sqmm PVC copper conductor and provn of 4.0 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
All as per item No. 59 above but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including rigid PVC conduit/ Casing caping on wall/ceiling with and including provision of MS box of suitable size with 3mm thick laminated hylam sheet cover for housing switch, socket, etc incl provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for following:- a). One light point controlled by one 05 Amps switch.
All as per item No. 66 above but One light point controlled by Two Nos of 2 way switch 05 Amps complete all as specified and directed.
All as per item No. 66 above but One fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No. 66 above but One socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No 66 above but for one socket out let 2 in 1, 5 and 15 Amps or AC point with 4 Sqmm PVC copper conductor and provn of 4.0 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
All as per item No 66 above but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed.
All as per item No 72 above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit complete all as specified and directed.
All as per item No 72 above but for cable of size 10 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm in & including concealed PVC conduit complete all as specified and directed.
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 10 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed.
All as per item No 75 above but for cable of size 16 sqmm aand one single core PVC insulated flexible copper conductor multistranded cable green colour of size 16 Sqmm as earth lead in & including concealed PVC conduit complete all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor 16 sqmm nominal cross section twin core for service connections all as required complete all as specified and directed.
All as per item No 77 above but cable of size 10 Sqmm 2 core complete all as specified and directed.
All as per item No 77 above but cable of size 6 Sqmm 2 core complete all as specified and directed.
M&L for metal clad plug top having 2 pole and earh 20/25 A for sheet metal enclosure complete all as specified and directed.
M&L in replacement of earthing with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion complete all as specified and directed.
Repair, maint and making the continuity of supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigrator, ACs etc. including providing of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any accessories found unserviceable that shall be replaced & paid under respective items of this Sch. (ii) Contractor/ superviser of contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectify on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor
Disconnecting electrically taking down existing ceilling / exhaust fan any type and capacity with due care dismanting blades and handing over to user for repairing from MES with all accessories complete all as specified and directed.
Assembling the fan any type with blades at site and hanging on ceilling /wall refixing after getting repaired from user complete with all accessories complete all as specified and directed.
Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete all as specified and directed. Note :- 1. Repairs will be measured and paid separately under respective items.
Rewinding of AC ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block complete all as specified and directed.
S&F fan capacitor AC 440 volts 4 mfd 50HZ complete all as specified and directed.
All as per item No 87 above but 2.5 mfd complete all as specified and directed.
All as per item No 87 above but 3.15 mfd complete all as specified and directed.
Supply and fixing in replacement of gun metal bush suitable for any size / model / type of fans complete all as specified & directed.
M&L for repairs, alignment grinding to shaft, remetalling & finishing complete all as specified and directed.
S&F ceiling fan shaft of standard size including taking out old shaft complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic, step type, hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed.
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair complete all as specified and directed.
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete all as specified and directed.
M&L in replacement of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete all as specified and directed.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long complete all as specified and directed.
All as per item No 97 above but of size 1 Mtrs long complete all as specified and directed.
All as per item No 97 above but of size 1.5 Mtrs long complete all as specified and directed.
All as per item No 97 above but of size 2 Mtrs long complete all as specified and directed.
All as per item No 97 above but of size 3 Mtrs long complete all as specified and directed.
All as per item No 97 above but of size 4 Mtrs long complete all as specified and directed.
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site complete all as specified and directed.
Supply and fixing in replacement of water lifting pump submersible type 220 -240 Volts 50 HZ complete all as specified and directed.
Supply & fixing in replacement of kit fan motor of desert cooler 230 volts with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed.
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed.
S&F in replacement of cooling coil of window type AC any cap up to 2 ton complete all as specified and directed.
S&F in replacement of front grill of window AC suitable for 1.5/2 ton cap complete all as specified and directed.
S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton cap complete all as specified and directed.
S&F in replacement of Air blower moter suitable for window/split type AC of 1.5/2 Ton capacity single phase complete all as specified and directed.
S&F in replacement of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd complete all as specified and directed.
S&F in replacement of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton complete all as specified and directed.
S&F in replacement of thermostat switch for window/split type AC of 1.5 /2.0 Ton capacity complete all as specified and directed.
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of Split type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from inner and outer unit and condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed.
Supply and install hi wall split units indoor with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 tonne complete all as specified and directed.
Supply and install hi wall split units outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 tonne complete all as specified and directed.
Supply and charging refrigerant R-22/R134a/R410 as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and directed.
Disconnecting, dismantling old u/s compressor from refrigrator and replaced with new for the refrigerator of capacity 165 to 310 Ltrs including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed.
Supply and fixing in replacement of Starting relay suitable for refrigerator of any make and capacity complete all as specified and directed.
Supply and fixing in replacement of Thermostat suitable for refrigerator of any make and capacity complete all as specified and directed.
Supply and fixing in replacement of PVC freezer door suitable for any size and capacity of the refrigerator complete all as specified and directed.
Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers complete all as specified & directed.
S&F ceiling fans with blades , down rods , electronic regulator and accessories, 230 v, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single phase.230V of size 380mm sweep with blades,and frame and louvers complete all as specified and directed.
Bharat Sales Corporation (BID ID -3482282)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderdocumentsT45.pdf
Tender Documents • 0.99 MB
BOQ_824782.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid