Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.3 LAdmitted-Finance | -23.76% | ₹14.3 L | L1 | Admitted-Finance |
| 2 | L2₹14.4 L+₹9,181.09 (0.64%)Admitted-Finance | -23.27% | ₹14.4 L+₹9,181.09 (0.64%) | L2 | Admitted-Finance |
| 3 | L3₹14.4 L+₹9,743.20 (0.68%)Admitted-Finance | -23.24% | ₹14.4 L+₹9,743.20 (0.68%) | L3 | Admitted-Finance |
| 4 | L4₹16.1 L+₹1.9 L (13.0%)Admitted-Finance | -13.88% | ₹16.1 L+₹1.9 L (13.0%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical Reject |
Tender Value
₹18.7 L
EMD Value
₹37,474
Closing Date
11 Jun 2026, 3:00 pmClosed
Executive Engineer, Elect.
Electrical Division No. 6, Vasant kunj
SITC of Sewage and Rain Water Discharge Pumps along with cable, earthing etc. for E1-E2 Road, Vasant Kunj.
2026_DDA_911443_1
11/EE/ELD-6/DDA/NIT/2026-27
Open Tender
Electrical Works
Percentage
30 days
As per tender documents
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹37,474
Yes
30 Jun 2026
4 Jun 2026
12 Jun 2026
4 Jun 2026
11 Jun 2026
4 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of 16-18 kW Rated Non-clogging type Sewage Submersible Pump-set having outlet of relevant size to be properly coupled to 150 mm DI pipeline working at 3 Phase AC supply 50 Hz with Copper-Winded Motor, CI Impeller, CI Casing, SS 410 Shaft running at 2800-3000 RPM speed, minimum 15 mm solid handling capacity i/c fittings,connections like Power & Control Cable, Lifting Chain, Guide Wire, Stationary Kit with Duck-Foot Bend etc. of relevant size & length complete as per site requirement & having following parameters and minimum 1 year brand warranty. Discharge (Approx.) = 36 m^3/hr (600 lpm) Head (Approx.) = 75 meter | 2 | Set | 3,87,508 | ₹7,75,016 |
| 2 | SITC of 9-11 kW Rated Non-clogging type Sewage Submersible Pump-set having outlet of relevant size to be properly coupled to 100 mm DI pipeline working at 3 Phase AC supply 50 Hz with Copper-Winded Motor, CI Impeller, CI Casing, SS 410 Shaft running at 1300-1500 RPM speed, minimum 45 mm solid handling capacity i/c fittings,connections like Power & Control Cable, Lifting Chain, Guide Wire, Stationary Kit with Duck-Foot Bend etc. of relevant size & length complete as per site requirement & having following parameters and minimum 1 year brand warranty. Discharge (Approx.) = 100 m^3/hr (1660 lpm) Head (Approx.) = 15 meter | 2 | Set | 2,35,046 | ₹4,70,092 |
| 3 | SITC of IP-54 Rated (Minimum) Powder-Coated Steel (CRCA Sheet) CPRI-approved Wall-Mounted LT Cubical Starter Panel for 16-18 kW non-clogging type sewage submersible pump-set given above in Item 1.00 i/c all accessories like 16-18 kW Rated Star-Delta Starter, 100 Ampere 36 kA Four Pole MCCB (Incomer), Moisture Protection Sensor, Winding Protection Sensor, Automatic Water Level Controller, Single Phase Preventor, Ammeter (0-60 Ampere Class 1.0 Accuracy) & Voltmeter (0-500 Volts) with Auto-Manual Selector Switch, ON & OFF phase-indicating lamps, fault-trip indicating lamps, Over Load Relay, Capacitor Bank (kVAR), 4 Pole Heavy-Duty AC-3 type Contactors, Star-Delta Timer, Push Buttons, 4 Strip (RYB+N) Aluminium Bus Bar of Minimum 150 Ampere Rating & Size 20 mm X 5 mm, Terminal Blocks, FRLS-H Control & Power Wiring, 2 Nos. 6 Ampere 10 kA "C" curve DP MCB for power & control wires, Provision for 3-Phase BSES Electricity Meter, Aluminium Cable Lugs & Double-Compression Brass Glands for connections & cable entry respectively, MV Danger Plate, Earth Bus Bar & Neutral Link etc. complete as required of suitable size & ratings. Note: Starter Panel Drawing shall be submitted in division by contractor for necessary approval & recommendation by engineer-in-charge before any execution or supply of work. | 2 | Each | 53,362 | ₹1,06,724 |
| 4 | SITC of IP-54 Rated (Minimum) Powder-Coated Steel (CRCA Sheet) CPRI-approved Wall-Mounted LT Cubical Starter Panel for 9-11 kW non-clogging type sewage submersible pump-set given above in Item 2.00 i/c all accessories like 9-11 kW Rated Star-Delta Starter, 63 Ampere 36 kA Four Pole MCB (Incomer), Moisture Protection Sensor, Winding Protection Sensor, Automatic Water Level Controller, Single Phase Preventor, Ammeter (0-60 Ampere, Class 1.0 Accuracy) & Voltmeter (0-500 Volts) with Auto-Manual Selector Switch, ON & OFF phase-indicating lamps, fault-trip indicating lamps, Over Load Relay, Capacitor Bank (kVAR), 4 Pole Heavy-Duty AC-3 type Contactors, Star-Delta Timer, Push Buttons, 4 Strip (RYB+N) Aluminium Bus Bar of Minimum 125 Ampere Rating & Size 20 mm X 5 mm, Terminal Blocks, FRLS-H Control & Power Wiring, 2 Nos. 6 Ampere 10 kA "C" curve DP MCB for power & control wires, Provision for 3-Phase BSES Electricity Meter, Aluminium Cable Lugs & Double-Compression Brass Glands for connections & cable entry respectively, MV Danger Plate, Earth Bus Bar & Neutral Link etc. complete as required of suitable size & ratings. Note: Starter Panel Drawing shall be submitted in division by contractor for necessary approval & recommendation by engineer-in-charge before any execution or supply of work. | 2 | Each | 40,657 | ₹81,314 |
| 5 | Supplying and fixing of following 4 C X 25 sqmm XLPE insulated & PVC sheathed Aluminium Armored Power Cable conforming to IS 7098 i/c all connections and fittings like thimble, joints, tape etc. complete etc as reqd. | 150 | Metre | 512 | ₹76,800 |
| 6 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required | 2 | Each | 402 | ₹804 |
| 7 | Supplying and fixing 4 Module (125mmX75mm) GI box along with modular base & cover plate for modular switches in recess etc. as required | 4 | Each | 401 | ₹1,604 |
| 8 | Supplying and fixing 8 way (4 + 24) Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | 2 | Each | 6,337 | ₹12,674 |
| 9 | Supplying and fixing 63 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required | 2 | Each | 3,597 | ₹7,194 |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point for Group C with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required | 16 | Point | 2,101 | ₹33,616 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
BOQ_957897.xls
BOQ • 6.76 MB
etendernotice11.pdf
Tender Documents • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .