Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.6 CrAccepted-Finance | ₹2.6 Cr | 1 | Accepted-Finance L1 as price comparative |
| 2 | 2₹2.8 CrRejected-Finance AGALPUR BLOCK IN THE DISTRICT OF BALANGIR | ₹2.8 Cr | 2 | Rejected-Finance L2 as price comparative |
| 3 | 2₹2.8 CrRejected-Finance WARD NO 19 BALANGIR MUNICIPALITY P O P S DIST BALANGIR PIN 767001 | BALANGIR | BALANGIR | ODISHA | 767001 | ₹2.8 Cr | 2 | Rejected-Finance L2 as price comparative |
| 4 | 2₹2.8 CrRejected-Finance | ₹2.8 Cr | 2 | Rejected-Finance L2 as price comparative |
| 5 | 2₹2.8 CrRejected-Finance GUDVELA DIST BALANGIR | ₹2.8 Cr | 2 | Rejected-Finance L2 as price comparative |
Updated dates
Tender Value
₹2.8 Cr
EMD Value
₹2.8 L
Closing Date
19 Jan 2026, 5:00 pmClosed
CCE (RandB) CIRCLE, BALANGIR
O/O CCE (RandB) CIRCLE, BALANGIR
Building Work
2025_EICCL_123711_6
CCE(R and B)BGR-15-2025-26
National Competitive Bid
Civil Works - Buildings
270 days
Balangir
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹2.8 L
Yes
13 Apr 2026
23 Dec 2025
20 Jan 2026
23 Dec 2025
19 Jan 2026
23 Dec 2025
23 Dec 2025 - 19 Jan 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness including cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-charge.
Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. Upto 1.5 Mtr Depth
Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground or as approved /directed by Engineer-in-charge, including all lifts involved.etc as per the direction of Engineer-in-charge.
Supplying, diluting and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 liters (or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc.complete as per IS:6313/1981(Part-II) and as per the direction of the Engineer -in-charge including all cost of materials, labour and T&P etc all complete.
Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance,royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.
Providing and laying Plain Cement Concrete of proportion (1:3:6) using 40 mm size grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
Providing and laying Brick masonry work in Foundation & Plinth using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/ Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.
R.C.C. Grade beams
R.C.C. Beams, columns, grider and bressmer etc. Ground Floor
First Floor
Second Floor
Terrace
R.C.C. Floor and Roof slab, landing, balconies up to 4.3Mtr. Height. Ground Floor
First Floor
Second Floor
Terrace
R.C.C. stairs excluding landing but including railing Ground Floor
First Floor
Second Floor
R.C.C. Lintels. Ground Floor
First Floor
Second Floor
Terrace
R.C.C. Chajjas & sunshade Ground Floor
First Floor
Second Floor
Terrace
Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.) Ground Floor
First Floor
Second Floor
Terrace
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace
Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/ chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace
Providing average 25mm thick grading Concrete with (1:2:2) using 6mm hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. Terrace
Providing & installing two component acrylic modified cementitious waterproofing coating with masterseal 551/ Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 kg/sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect as per direction of the Engineer -in-charge. Terrace
Providing and laying Vitrified Floor Tiles confirming to IS : 15622 of of approved make, quality and colour without any warpage,with intermidiate spacers of 4 mm width laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) with intermidiate spacers of 4 mm including cutting to size, laying and filling the joints with epoxy tile grout of approved shade and colour, cleaning the surfaces with oxlaic acid, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Make: Tiles-Kajaria/ Somany/ Equivalent. Grout-Fosroc/ Kerakoll/ Weber/ Equivalent (Note- Sample of tiles shall be approved before procurement and use. Size of Tile 600 x 600 mm Ground Floor
First Floor
Second Floor
Providing and laying Vitrified Floor Tiles in Dado/Skirting confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use. Size of Tile 600 x 600 mm Ground Floor
First Floor
Second Floor
Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. Ground Floor
First Floor
Second Floor
Providing & laying granite stone tiles in dado/ skirting using 10mm thick granite stone slab of approved quality, colour and size Above 0.10 Sqm & up to 0.4 sqm to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) Ground Floor
First Floor
Second Floor
Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Counters, Stair Treads, Risers, planter boxes, window sills etc over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, taxes, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use. Ground Floor
First Floor
Second Floor
Providing and fixing cement concrete tiles of average 22 mm thick jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).as per the design & drawing with cost of all materials, labour, conveyance, taxes, T&P etc. All complete as per the direction of Engineer -in-charge. Ground Floor
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge. Ground Floor
Providing and fixing ISI marked Double Leaf both side laminated flush door shutters confirming to IS 2202 (Part1) of 35 mm thickness including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as, SS Concealed Hinges (5"), stopper, top pivot, top patch, bottom patch, Door magnet, SS Tower bolt-8", Mortise lock Handle, Cylinder coin & knob key & knob, SS lock body and Floor Spring etc. including cost of all labours, materials, conveyance, hardware fixing,loading and unloading and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.The cost will include providing fitting and fixing in proper position factory made wooden polymer composite (WPC) door frame having waterproof, termite & borer Proof, no rotting, swell & crack proof, bend & warp resistant properties of size 62 mm x 100 mm (dimension torelance 5 mm, subjected to approval of the EIC, no extra payment will be made for diiference in sizes) conforming to relevant IS specifications, of approved design and drawing fitted to the masonary/ concrete wall with anchor bolts of required size Ground Floor
First Floor
Second Floor
Providing and fixing ISI marked both side laminated flush door shutters confirming to IS 2202(Part 1) of 34mm thickness with approved colour paint over a coat of primer etc including ISI marked necessary hardware fittings such as, SS Concealed Hinges (6"), stopper, Door eye & magnet, SS Tower bolt-8", Mortise lock Handle, Cylinder coin & knob key & knob, SS lock body etc. including cost of all labours, materials, conveyance, hardware fixing, loading and unloading and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.The cost will include providing fitting and fixing in proper position factory made wooden polymer composite (WPC) door frame having waterproof, termite & borer Proof, no rotting, swell & crack proof, bend & warp resistant properties of size 62 mm x 100 mm (dimension torelance 5 mm, subjected to approval of the EIC, no extra payment will be made for diiference in sizes) conforming to relevant IS specifications, of approved design and drawing fitted to the masonary/ concrete wall with anchor bolts of required size Ground Floor
First Floor
Second Floor
Providing and fixing ISI marked both side laminated flush door shutters confirming to IS 2202(Part 1) of 35 mm thickness with approved colour paint over a coat of primer etc including ISI marked necessary hardware fittings such as, SS Concealed Hinges (5"), stopper, Door eye & magnet, SS Tower bolt-8", Mortise lock Handle, Cylinder coin & knob key & knob, SS lock body etc. including cost of all labours, materials, conveyance, hardware fixing, loading and unloading and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.The cost will include providing fitting and fixing in proper position factory made wooden polymer composite (WPC) door frame having waterproof, termite & borer Proof, no rotting, swell & crack proof, bend & warp resistant properties of size 62 mm x 100 mm (dimension torelance 5 mm, subjected to approval of the EIC, no extra payment will be made for diiference in sizes) conforming to relevant IS specifications, of approved design and drawing fitted to the masonary/ concrete wall with anchor bolts of required size Ground Floor
First Floor
Second Floor
Supply and fixing of uPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 2 Track 2 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement. Ground Floor
First Floor
Second Floor
Supply and fixing of uPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 3 Track 3 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement. Ground Floor
First Floor
Second Floor
Terrace
Supply and fixing of uPVC Top Hung glazed uPVC ventilator made out of hollow multi chambered uPVC sections having isolated drainage system with the design Casement (Outside open) The casment frame of the window having over all size of 60 x 52 mm having internal wall thickness of 3.00 mm. The glass panel shall be made out of Upvc sections with over all size of 52 x 78 mm with internal thickness of 3.00 mm. Reinforcement of galvonised mild steel with thickness of 1.20 mm has to put throughout the frame, glass panel. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight. Single point locking system (called Cockspur) made out of casted zamac with white powder coated and Friction and Stray Hinges will be made of SS 304 grade material. Multipoint locking system (called Espag) made out of casted zamac with white powder coated can be used if height goes beyond 4.50 feet. The model and brand of the uPvc window shall be approved by the Engineer -in- charge before fixing. Glass thickness and colour will be change as per requirement. Ground Floor
First Floor
Second Floor
Supplying and fixing upvc ventilator with partially fixed glass,partially top hung & provision for exhaust having a frame size of 60 w x 45 ht and wall thickness of 2mm.The upvc frame is reinforced throughout with galvanised steel of 1.2mm thickness. The sash has a size of 60 w x 78 h and wall thickness 1.2 mm reinforced with galvanised steel throughout. The glazing provided is of thickness 5mm frosted glass both in fixed glass and in sash panel.The model and brand of the upvc ventilator shall be approved by the EIC before fixing.The rates shall be inclusive of all cost of materials,labour,T&P etc. complete. Ground Floor
First Floor
Second Floor
Supplying, Fitting and Fixing M.S works of approved designs made out of M S Flat, hollwo section, i Section, Square bars/ Round bars etc. in railings, grills, gates etc of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace
Supplying, fitting and fixing of stainless steel of 304 grade in hand rail using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mt c/c and stainless square pipe bacing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- charge. Ground Floor
First Floor
Second Floor
Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-charge. (Note- colour and shade shall be approved before procurement and use.) Ground Floor
First Floor
Second Floor
Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground Floor
First Floor
Second Floor
Terrace
Providing and applying two coats of Weather Coat Paint of approved make, quality and shade to the external surface of the building over a coat of primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting of approved shade and quality after cleaning the plastered surface perfectly by watering and brushing including cost of material, putty, paint, brushes, all labour, taxes, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground Floor
First Floor
Second Floor
Terrace
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size well rammed ,with side rcc wall and consolidated and grouted with fine sand including finishing the top smooth including watering, curing, cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. Ground Floor
Providing fitting and fixing of false ceilling with aluminium anodised T section No. 3215 with 2'-0" C/C, L section No. 1705 upto 15 micron on four walls to be fixed by means of steel screws and P.V.C plug and the aluminium grid 2'-0" x 2'-0" with 12.5 mm gypsum board suspended from ceiling etc icluding all cost of labour, material, T&P, conveyance, royalities and taxes etc all complete as per the direction of Engineer In Charge. Ground Floor
First Floor
Second Floor
Supplying, fitting & fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16 mm of approved design and quality complete with frame and all fitting and fixtures including the cost of all materials, labour, conveyance, taxes, T&P etc. All complete as per the direction of Engineer -in-charge. Ground Floor
First Floor
Second Floor
Providing and fixing Glass Reinforced Concrete (G.R.C) Jallis in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with layering technique Power Spray methodology have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens casting shall take place with layering methodology using- Direct Power Spray machines. The screens shall be casted from ‘53 grade’ White Portland Cement fine graded, sieved Quartz & Silica Sand, reinforced with Alkali Resistant Glass Fiber manufactured between 4-5% having Zirconia content at least 16%, Super Plasticizers and U.V resistant Synthetic inorganic pigments should be used. The material casting should take place in FRP Molds. The GRC Panels flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.P should be above or equivalent to 15 N/mm2 for tests done on 28 days cured samples. The fixing of panels should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners & Self Tapping screws or as per approved shop drawings approved by site engineer in charge. Ground Floor
First Floor
Second Floor
Providing and fixing wooden panelling suitably fixed to the walls with 19 mm thick bwp ply , finished with 1 mm thick texture / suede laminate complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish enamel paints / polish with mellamine to match with the shade of the Laminates. Ground Floor
First Floor
Second Floor
Providing and laying factory made cement concrete interlocking paver block of M -40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge 80 mm thick
Supplying & fixing at site factory made/ precast/ cast in situ cement concrete kerb stone of M-40 grade of top and bottom width 115 and 165 mm respectively, 250 mm high in M-40 grade, PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone including cost of all labours, materials, conveyance, loading and unloading, and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge & MoRTH Clause 408.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m² including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20mm dia C - PVC pipe Ground Floor
First Floor
Second Floor
25mm dia C - PVC pipe Ground Floor
First Floor
Second Floor
32mm dia C - PVC pipe Top Floor
40mm dia C - PVC pipe Top Floor
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
15 mm dia CP S.B. Bib cock(CON-CHR-037KN)
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
25mm dia brass full way valve (Shakti make)
32mm dia brass full way valve (Shakti make)
40mm dia brass full way valve (Shakti make)
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR)
15mm CP Extension piece
125mm CP grating
15mm size C.P. flange
Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 2nd floor
supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. Ground Floor
First Floor
Second Floor
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Supreme /Ashirvad)
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 580mm size Orissa pan (Hindware/Parryware/Neycer make)
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge One piece commod(Hindware)ELEMENT Cat No.92084.
Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal
Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge Halfpedestal basin(560x450)Hindware No.91049+91115
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N
CP towel Ring(Jaquar)ACN-ACR-1121N
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 600mmx450mm size B.E mirror (swivelled type)
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder (Jaquar)ACN-ACR-1131N
Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. 15mm CP revolving shower (Jaquar)CON-CHR-209KN
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge ) Kajaria/Somany/Johnson tile 60cmx60cm Ground Floor
First Floor
Second Floor
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) Kajaria/Somany/Johnson tile 60cmx30cm Ground Floor
First Floor
Second Floor
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.
Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge.
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge Aqua guard pure Chill 80 PSS UV
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe
150mm dia P.V.C. pipe
Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
1 no 50 users RCC septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
14,000 ltr capacity R.C.C. Under ground sump of in side size (2.80m x 2.80m x 2.0m) Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge.
Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft.
Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of ELC.
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge RCC floor, roof slab chhaja up to 4.430 m height
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge
RAIN WATER HARVESTING SYSTEM(PIT)(2 nos) Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floorSlab
providing and filling filter media 40mm Boulder-
20mm washed gravel--
Course sand-
Providing fitting & fixing M.S.grill cover over the harvesty pindi
Sinking of tube well(200) for PIT Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 25mtr
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. 200mm dia PVC pipe
cost of 200mm pvc pipe
Cutting slot in casing pipe for recharge of rain water
labour for packing gravel outside the tube well
Cost of washed gravel
Construction of 1 no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 30mtr
30 mtr to 45mtr
Drilling of 150mm dia bore 45 mtr to 215.00mtr
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes 00 mtr to 30 mtrs
30 mtr to 60mtr
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 200mm dia PVC (sch-80) pipe
Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH Rig
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby)
DOL Control panel
40mm dia steel short piece
Well cap
50mm size CI bracket
2.50sqmm flat cable
20mm dia rigid UPVC pipes
Steel rope with cover
Labour charges for lowering including transportation
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 32mm HDPE pipes (Finolex/Supreme make)
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group A
Group B
Group C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 16A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X2.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X16+2X0)
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of not more than 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years.
Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, Top opening clean room LED luminaire of 600 X 600 x 65 mm size with of 45 W and system lumens output not less than 4500 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .Each CLEAN ROOM FITTING .
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
Supply & fixing of 45 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories etc. as required as per direction of Engg.-in-Charge.etc. as required as per direction of Engg.-in-Charge.
Supply, Testing & commissioning of IP-65 Bulkhead,wall mounting 1 x 10W LED light fitting including 1 no. of 10watt LED luminairs as per EIC of approved make including with all,., materials & labour. (Make-Wipro/Philips/Trilux/LT/Jaquar/Leksa-Light)
BDBS,DB,AC DB,FLOOR PANELS,MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 6Way (8+18) Way TPN MCB DD DB Horizontal type suitable for flush mounting and surface mounting with 100A Copper Bus Bar for each phase,with neutral Bus bar,Earth Bar & Cable ties for cable management,prefitted masking sheet,IP43-IK09 with metal door (For LIGHT,POWER INDOOR, 3-PH,POWER LOAD) Warranty on DB is 3 years
4Way (4+12) Way TPN MCB DD DB Horizontal type suitable for flush mounting and surface mounting with 100A Copper Bus Bar for each phase,with neutral Bus bar,Earth Bar & Cable ties for cable management,prefitted masking sheet,IP43-IK09 with metal door (For LIGHT,POWER INDOOR, 3-PH,POWER LOAD) Warranty on DB is 3 years
Supplying and fixing 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 40/63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
Supplying and fixing 32Amps rating,C series,10KA breaking capacity, FP 415 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
(Earthing) INSTALLATION Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
CABLING AND END TERMINATION MAIN AREA Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 120 sq mm
2core x 4 sq mm
LAYING OF CABLE Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x120 sq mm
Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia
Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia
PANELS S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 no 200A 4P MCCB 25kA,C series with on/off trip indication. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA)) In commer- 01 no 200A 4P Off Load Change Over switch Busbar- 04 numbers of 300Amps 30*5mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 09 nos 40-63A 4P MCB 10kA,C series Power load to PDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 Out going- 06 nos 32A 4P MCB 10kA,C series Light load to LDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB201 Out going- 03 nos 32A 2P MCB 10kA,C series Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB202 Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-200Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) (iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
INTERNAL ROAD & PATHWAYS Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, trees girth upto 300 mm , removal of stumps of trees cut earlier and disposal of unserviceable materials including removal and disposal of top organic soil not exceeding 150 mm in thickness, including cost of all labours, materials, conveyance, loading and unloading, taxes, sundries, T&P etc all complete as per direction of the Engineer -in-charge.
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified upto the specified depth mentioned in the approved Drawing & Design, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction construction & Clause 305 of MoSRT&H Specifications for Road & Bridge works (5th Revision).
Construction of granular sub-base by providing Close graded Granular subbase using Grading-IV material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (5th Revision) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of all machineries, etc. all complete as per the direction of the Engineer -in -charge
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (5th Revision) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of all machineries, etc. all complete as per the direction of the Engineer -in -charge
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing 90 Cm Equilateral triangle
80 x 60 Cm rectangular
Providing and laying factory made cement concrete interlocking paver block of M -40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge 80 mm thick
Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance, royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.
Supplying & fixing at site factory made/ precast cement concrete kerb stone of M-30 grade of size 600 x300 x150 including cost of all labours, materials, conveyance, loading and unloading, and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge & MoRTH Clause 408. The rate includes excavation of trenches, laying of foundation concrete & sand & mortar bed etc. as per approved drawings. The work will be executed as per the final approved Cross Section by the EIC.
Providing and laying Plain Cement Concrete of proportion (1:4:8) using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
Providing and laying Brick masonry work in Foundation & Plinth using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-20 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/ Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.
R.C.C. Grade beams
R.C.C. Beams, columns, grider and bressmer etc.
Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.)
Providing Fly-Ash bricks masonry work in Super Structure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.
Painting two coats of synthetic enamel paint over Iron & Wood Works as per approved shade of approved quality over a coat of primer (excluding the cost of priming), sand papering, polishing the surface including cost, conveyance,materials, labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints and primer are to be approved before procurement and use)
Providing 12mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
Providing 16mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
Providing and applying two coats of Weather Coat Paint of approved make, quality and shade to the external surface of the building over a coat of primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting of approved shade and quality after cleaning the plastered surface perfectly by watering and brushing including cost of material, putty, paint, brushes, all labour, taxes, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)
INTERNAL DRAIN Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. Upto 1.5 Mtr Depth
Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground or as approved /directed by Engineer-in-charge, including all lifts involved.etc as per the direction of Engineer-in-charge.
Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance, royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.
Providing and laying Plain Cement Concrete of proportion (1:3:6) using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
Providing and laying Brick masonry work in Foundation & Plinth using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/ Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.
R.C.C. Walls
R.C.C. Slab
Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.)
Providing and laying of Cement Concrete of grade 1: 2 :4 (1cement : 2 sand : 4 graded stone aggregate of size 12mm hard granite crusher broken chips ) , mixing in concrete mixer ,lowering and compacting to proper thickness , watering & curing for the required period including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
Providing 12mm thick cement plaster in cement mortar (1:4) with neat cement punning to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.
Providing and laying non-pressure NP3 class (Medium duty) R.C.C. pipes with Spigot Joint with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) in trenches including excavation of trenches,bedding with cement concrete 1:5:10 & making haunches all around the pipe with cement concrete 1:2:4, refilling the trenches after laying the pipe with excavated earth/sand & testing of joints etc.all complete as per the direction of Engineer-in-Charge. 300 mm dia R.C.C pipe
Please Enable Macros to View BoQ information
stage.html
html • 0.08 MB
technical_573075.pdf
techsummary_573075.pdf
finance_573075.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.82 MB
BOQ_573075.xls
BOQ • 0.52 MB
DTCN6.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid