Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.1 LAdmitted-Finance | +5.50% | ₹12.1 L | L1 | Admitted-Finance |
Tender Value
₹11.4 L
EMD Value
₹22,860
Closing Date
14 Aug 2026, 6:00 pmClosed
Executive Engineer
PWD Electrical Division I Jaipur
SITC of 315 KVA Transformer and other Electric work at Udyog Bhawan, Jaipur.
2026_CEPWD_582287_12
NIT NO 09 of 2026-27 EE PWD E-I Jaipur
Open Tender
Electrical Works
Percentage
120 days
Udyog Bhawan
Please refer tender documents
2 documents required · 2 mandatory
₹500
Through Egras Challan in Office ID 4222
₹22,860
Yes
In the Chamber of Executive Engineer
18 Aug 2026
5 Aug 2026
17 Aug 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
10 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. | 30 | Mtr | 133 | ₹3,990 |
| 1.02 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.400.0 Sq. mm.3.5 core | 30 | Mtr | 2,372 | ₹71,160 |
| 1.03 | Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same | 30 | Mtr | 25 | ₹750 |
| 1.04 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. 11 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm | 2 | Each | 4,198 | ₹8,396 |
| 1.05 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. 11 KV Straight Through Joint Kit . 3 core 120/150/185 Sq.mm | 1 | Each | 8,660 | ₹8,660 |
| 1.06 | SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7 (c) Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. (e) Testing of earth resistance for value of 5 ohms or less as required. (f) Test certificates for confirming above standards from OEM is mandatory. 17.2 mm thick and 3 Mtr. Long | 4 | Set | 7,157 | ₹28,628 |
| 1.07 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.25mm x 3mm G.I. ( Hot Dipped ) Strip | 10 | Mtr. | 158 | ₹1,580 |
| 1.08 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.25mm x 3mm copper strip | 10 | Mtr. | 1,129 | ₹11,290 |
| 1.09 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required. 300 mm sweep(900 RPM) | 1 | Each | 2,955 | ₹2,955 |
| 1.1 | Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required. 450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute | 4 | Each | 6,177 | ₹24,708 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Tendernotice_2.pdf
PDF • 3.10 MB
BOQ_1034646.xls
BOQ • 0.33 MB
Cover12.pdf
Tender Documents • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .