Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹19.9 L+₹52,307.50 (2.63%)Accepted-AOC | L3 | Accepted-AOC lowest bidder | |
| 2 | L1₹19.9 LRejected-Finance | L1 | Rejected-Finance Non bonafied as per tender document | |
| 3 | L2₹19.9 L+₹1,270.67 (0.06%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Non bonafied as per tender document | |
| 4 | L4₹20.8 L+₹87,704.47 (4.41%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.3 L+₹5.4 L (27.0%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
2 May 2020, 6:00 pmClosed
GE (N) Delhi Cantt-10
GE (N) Delhi Cantt-10
OPERATION OF SEWAGE TREATMENT PLANT AND REPAIR MAINT OF RO PLANTS AND SYSTEMS WITH CONNECTED ITEMS AT ANAND PARBAT HIRAN KUDNA M AND O OF SEWAGE PUMP 17 SIKH LI ME LINE MIL STN UNDER GE N DELHI CANTT 10
2020_MES_336209_1
GE/NORTH-73/2019-20
Open Tender
Civil Works
Works
333 days
GE (N) Delhi Cantt-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) Delhi Cantt-10
₹76,000
Yes
30 May 2020
24 Mar 2020
4 May 2020
24 Mar 2020
2 May 2020
15 Apr 2020
Amount
PART -I Manning & Operation of Sewage Pump installation at 17 SIKH LI under COD Area, Delhi Cantt in one Shift operation of 08 Hrs (06.00 AM to 2.00 PM) including Sunday and Holiday by deploying one opertaor including cleaning of installation complete all as directed (TOTAL FGM / OPERATOR - 01 No) The installation to be manned comprises the folowings :- (i) Sewage Pump 02 Nos of capacity 12.5 HP for pumping out sewage water to sewage line
Manning and Operation of Sewage Pump installation at 17 Sikh LI under COD area, Delhi Cantt in one shfit operation of 08 Hrs (02.00 PM to 10.00 PM) inclduing Sunday and Holiday by Deplying one opertaor inlcuding cleaning of of installation complete all as directed ( TOTAL FGM / OPERATOR -01 No). The installation to be manned comprises the following :- Note for item No 1 & 2. (i) Operation of pump installation of any capacity and run the pump time to time as on required basis. (ii) Claning the blockage in any pump / pipe line. (iii) Complete cleaning of the installation. (iv) During the cleaning safety and cleaning equipments will be supplied by the contractor (Necessary Oxygen Mask , Gloves, Gum Boot and all other safety aspects and including necessary T & P items, Phaswda , Steel Bucket , Maina rope, torch etc as required at site and all as directed) (v) Log sheet for records shall be suppled by the contractor and record to be updated by the opertor. (vi) FGM / OEPRATOR should be deployed by contracot for 5 months for item No 2 as directed by GE
Scope of work are as under for Srl Item No 01 to 02 : (i) The plant shall be run by the deploying skilled ITI holder operator with proper experience.
(ii) For payment of minimum wages to the workers provisions of particulars specification shall be strictly adhered to as labour law.
(iii) log book for records shall be supplied by the contractor after approval of format by GE/ Engr-in-charge/JE and record to be submitted by the contractor daily basis.
(iv) Operation of pump installation of any capacity and run the pump time to time as on required basis.
(v) Cleaning the blockage in any pump / Pipe line.
(vi) Complete cleaning of the installation.
(vii) During the cleaning saftey and cleaing equipments will be suppled by the contractor (Necessary Oxygen Mask, Gloves , Gum Boot and all other Safey aspects and inclduing necessary T & P items, Phawda, Steel Bucket, Manila rope.
Manning & Operation and maintenance of sewage Treatment plant of 100 KLD per Day cap at 21 Signal Group Anand Parbat including Sunday and holidays in two shifts of 08 hrs each day by employing one operator for (1st shift 06.00 AM to 02.00 PM, 2nd shift 02.00 PM to 10.00 PM, complete inclusive of daily, weekly , monthly, quarterly, half yearly , and yearly comprehensive maintenance complete all as specified and directed. ( TOTAL FGM / OPERATOR - 02 Nos)
(A) following items to be maintained:-
(i) Bar screen chamber
(ii) MBBR reactor
(iii) Air blower
(iv) Tube settler
(v) Filter feed Pump
(vi) Filteration system
(vii) Feed pump and raw water sewage pump
(viii) inter connecting pipes
(ix) chlorine contact tank/ hypo Dosing tank
(x) Valves
(xi) sludge holding tank with filter press
(xii) Electricals system and DB/ panel
(xiii) oil and grease trap
(xiv) raw water collection sump
(xv) installed machinary for treated water supply
(xvi) Treated water Tank installed with STP
(xvii) Sewage lift well
(xviii) Equalization tank
(B) Scope of work are as under:-
(i) Stacking the sludge cakes properly and disposing the same away from site appx 500 m all as directed by Engr-in-charge
(ii) Cleaning the blockages in any pump/ pipe line
(iii) Supplying/ distrbuting the traeted water regularly as per the directions
(iv) complete cleaning of grits and channels daily
(v) Brooms and cleaning materials will be provided by the contractor free of cost at site in good workable condition and keep maintain plant premises free from vegetation
(vi) During the cleaning safety equipments will be issued by the contractor to operator (Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary T&P items,Phawda, Steel Bucket, Manila rope etc. as required at site and all as directed)
(vii) Removing the sludge in the tube selttler and keeping the surrounding area clean daily and removing vegetation
(viii) Cleaning of equilization tank throughly by removing mud grits etc from the tank, cleaning inner surface of tank complete by scraping with brush and and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr and washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
(C) Maintaining the following records
(i) Record of chemical consumption
(ii) Record of treated water and electricity (log sheet)
(D) Notes
(i) The plant shall be run by the deploying skilled ITI holder operator with proper experience.
(ii) For payment of minimum wages to the workers provisions of particulars specification shall be strictly adhered to Labour low as applicable
(iii) log book for records shall be supplied by the contractor after approval of format by GE/ Engr-in-charge/JE and record to be submitted by the contractor daily basis.
(iv) Chemicals etc., will be measured and paid seperately under respective item as supply only.
PART -II Repair/maintenance and servicing of RO system, RO+UV+UF 12.5 LPH capacity and storge capcity 12 Ltrs of purified water. Make EUKAWA, including servicing/cleaning of filters. (un-serviceable parts will be meausred and paid seperately) Under respective items, Make of EUKAWA
Note :- (a) Unserviceable and consumable parts shall be measured and paid seperately under relevent items ser item No.03 to 18. (b) Servicing shall be done quarterly for each RO system and also to be attended as on tele call from users. (c) Servicing shall be done through authorsied dealer of OEM (d) Spare parts shall be purchased through authorsed dealer of OEM. (e) Rate quoted are deemed to be inclusive of labour required for replacement of any defective parts in between consecutive services.
Supply only membrane filmtech 75 GPD.
Supply only raw water pump kemflow K-48
Replacement in repairs AC/DC Adopter complete.
Supply only solenoid valve.
Supply only candle/inline filter for prefilter.
Supply only candle/inline filter for sediment filter.
Supply only candle/inline filter for carban filter.
Supply only UV lamp.
Supply only prefilter bowl with spun candle filter 10" size.
Supply only resistance of RO system complete.
Supply only outer cover/body of RO system with suitable size.
Supply only Memberane housing of RO system with suitable size.
Supply only UV electronic Ballast (Choke) 11W of RO Make: Philips/Desent.
Supply only float valve as per existing suitable for RO system complete.
Supply only Bib Tap as per existing suitable for RO system complete.
Supply only PVC Elbow suitable for RO system complete.
Repair/maintenacne and servicing of RO system, 500/700/1000 LPH capacity. Make of Eukaw&,Aquefresh&SIMA respectively, including servicing/cleaning of all filters/back wash etc all as directed. Note :- (a) Unserviceable and consumable parts will be measured and paid seperately unde relevent items (item No 66 to 80) (b)Servicing shall be done monthly for RO system and also to be attended as on tele call fro MES rep.
Supply only in repairs membrane high pressure, 500 LPH.Make DOW/Hydronautics/ CSM
Supply only in repairs membrane high pressure, 700 LPH.Make DOW/Hydronautics/ CSM
Supply onlyl repairs membrane high pressure, 1000 LPH.Make DOW/Hydronautics/ CSM
Replacement in repairs for sediment(sand and silt), dirt and rust particles, high efficiency, low pressure drop, removal up to 5 micron filter cartridges suitable 500/700/1000LPH capacity all as specified.
Replacement media in sand filter (gravel,pebles,fine sand).
Replacement activated carban in barban filter.
Supply only RO antiscalent high PH for membrane cleaner.
Replacement in repairs Rotameter suitable for 500/700/1000LPH capacity RO system. Make as per sample.
Replacement in repairs of UPVC pipe 20mm dia with fitting complete suitable for RO system as per sample.
Replacement in repairs of Membrane housing suitable for 500 LPH capacity RO system of Aquefresh Make .Painter/Hitech.
Replacement in repairs of Membrane housing suitable for 700 LPH capacity RO system of Aquefresh Make .Painter/Hitech.
Replacement in repairs of Membrane housing suitable for 1000 LPH capacity RO system of Aquefresh Make .Painter/Hitech.
Replacement in repairs of housing bowl suitable for 500/700/1000 LPH capacity RO system of Aquefresh Make .As per sample.
Replacement in repairs of LT Relay,230V AC supply suitable for 500/700/1000 LPH capacity RO system Make .As per sample.
Supply and fixing in reapirs of multi port valves fixing at sand filter and carbon filter vessles all as specified and directed. Makes as per sample.
M&L for Disconnection electrical and water connection of the raw water feed monoblock pumpset with motor and base plate and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto 2 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning etc. Contractor nothing shall be extra payable in the account.
M&L for Disconnection electrical and water connection of the high presuure feed pump, multi stage centrifugal type and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto 2 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
S&F in repairs for antiscalant dosing unit capacity upto 6 LPH @ 3.5 bar incl inlet and outlet flexible pvc pipes all as specified and directed.
S&F in repairs pressure gauges for monitering of flow meters all as specified and directed.(Makes as per sample)
Testing of treated water of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved. (a) Carrying out minimum essential testing of water as per IS 3025 mandatory for chemical, odour, PH Value TSS BOD COD residual chlorine total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms as below:- Rest of the characterstied of the treated water shall be as per IS : 3025 Note 1 - rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
(i) TSS: < 10 Mg/ ltrs
(ii) BOD : < 10 Mg/ ltrs
(iii) COD :< 150 mg / Ltrs
(v) Total coliform : ,< 100 MPN/100 Ml (desired Nil)
(vi) Residual CI > 1 mg/ Ltr
(v) Rest of the characterstied of the treated water shall be as per IS : 3025
Note 3 - Incase contractor fails to provide monthly test report a penalty of Rs 3000/- per test report shall be recovered from the contractor dues.
Testing of Sewage sludge water as per revlevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value TSS BOD COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water:- Note 1 - Rates quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
Supply & mixing of Sodium Hypo Choloride having 10 % content
Supply & mixing of Poly Aluminium Choloride 100 % purity
Supply & mixing of Poly Electrolite 100 % purity
Supply & filling compressor oil 460 Make : Castrol
Material and labour in replacement of quartz silica sand 32-64 grade
Material and labour in replacement of quartz silica sand 16-32 grade
Material and labour in replacement of quartz silica sand 8-16 grade
Material and labour in replacement of quartz silica sand 4-8 grade
Material and labour in replacement of activated carbon IV 1000
Material and labour in replacement of FEB (MBBR) Media suitable for STP make as per sample.
Taking out complete pebbles from the bottom upto the depth of 0.6 Mtr of the filter of size 1800 mm dia and 2300 mm height and refilling the same pebbles after washing and cleaning thoroughly.
Periodical Cleaning of Sewage well and Removing of settle down Sewage sludge cum mud/De-Silting etc. all as required at site and directed at 21 Signal Group Anand Parbat for Sewage well. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :-
(a) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes
(b) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by PCB or as directed.
(c) Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary tarpaline ) and depositing the same to the location where approved by PCB or as directed.
(d) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the PCB or as directed.
(e) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank and all as directed.
(f) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed.
M & L for cleaning of treated water tank at 21 Signal Group Anand Parbat STP of storage capacity of water 50000 gallons, filter feed tank of capacity 63 cum and chlorine contact tank of capacity 17 cum thoroughly by removing mud, grits etc from the tank by following method :-
(a) Cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed.
(b) Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
Supply and laying including taking up galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends,elbow, tees,short pieces,connectors,back nuts,diminishing pieces,caps,plugs, threaded flanges and unions,etc) and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:-
80 mm dia
50 mm dia
40 mm dia
Supply and laying Mild steel water tubing heavy duty with wlded joints complete with all tube fitting (such as bends,elbow,tees,short pieces,connectors,back nuts,diminishing pieces,caps,plugs, flanges and unions,etc) and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches,etc.,also cutting,screwing,welding and waste end for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:-
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Supply and fixing Butterfly valves iron body screwed down high pressure with iron wheel head/ long shank and cup butterfly type screwed both ends for iron pipe including taking out unserviceable valve for the following sizes:-
40 mm dia
50 mm dia
80 mm dia
M&L for spray painting two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete of complete Sewage treatment plant capacity 100 Cum/day with equalization tank, Raw sewage pumps, MBBR reactor, Chlorine tank, filter feed pump, Dual media filters, RCC treated water tank, treated filter pumps, sludge drying beds, oil free blowers and accessories complete all as specified and directed.
M&L for Disconnection electrical and water connection of the monoblock pumpset with motor and base plate and transporting to work shop opening carefully and replacement of winding, bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto 7.5 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
M&L for Disconnection electrical and water connection of the compressors and transporting to work shop opening carefully and replacement of spare parts bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of up to 110 M3/hr. Note :- Rate includes transportation of compressor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
M&L for Lifting/lowering of non clogging submersible pump and motor capacity up to 7.5 HP from Sewage well after disconnecting electric and water connection of any make and any size capacity under any of chain pulley block or manually appropriate length upto 10Mtr after opening the socket and pipe eplacement of winding, bushes, gland packing, ball bearing, thrust bearings, sand guard plate,GM impellers,rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed.
M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, flooring and coping filling and mass concrete with cement plastering finishing all as specified and directed.
M&Lbrickwork fixed in repiar with subclass ‘B’ bricks, with cement motor 1:6 straight or curved on plan exc 6m mean radius built in incl necessary earth work all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete sur- faces in cement plaster 1:6 to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for in repairs Machine pressed precast conctete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade incl sand filling all as specified and directed.
M&L for broken stone boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
Supply and fixing in reapirs of multi port valves fixing at media filter vesselses for STP all as specified and directed. Makes as per sample.
S&F in repairs for dosing unit capacity electronic metering pumps for chemiclas dosing system for STP incl inlet and outlet flexible pvc pipes all as specified and directed.Makes as per sample
Material & Labour for cross arms, bracings, supports, clamps, angle iron, flats, ladders and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as directed.
S&F in repairs for Rotational moulded polye- thylene water storage tanks 250 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S&F in repairs for display/sign board box type of size 150cm x 90 cm x 20 cm with acrylic sheet with aluminium frame on front side and GI sheet of suitable size on rear side and housing with LED type ftg 4 x 20 W for proper illumination inclding connection etc and marking the Installations/Flow diagram with lumination sticker/painting of size all as specified and directed.(Makes as per sample kept in AGE E/M office)
S&F in repairs for informatory sign boards of size 750x600mm rectangular type made out of retro reflective sheeting of Micro prismatic grade conforming to IRC 67:2010/ASTM D4956 Type XI standards, fixed over 3mm thick aluminium composite panel supported with back support stainless steel 50mm dia pipe as approved & supported on a 2.1 mtrs long posts. The details of description for each board and the fixing at site shall be in suitable size of foundation in PCC 1:2:4 type B1 all as specified and directed.
S&F in Existing LT PB for repairs/replacement of 95 Amps TP contactors(03 Nos),50 to 70 amps contactor (01 No), Over load relay 66-110Amps(01No) and 45 to 75 amps(01No) for suitable for fully automatic Star Delta starter capacity of 75 HP pumping sets with suitable size copper wiring,lugs and accessories complete all as specified and ditected.(Makes of contactors C&S/L&T)
S&F in repairs for Ball brass valves 50 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified.
Note For Srl No 1 to 03 for bidder:- 1. Security Deposit @ 10% of total quoted amount in addition to Performance Security @5% shall be deposited by the contractor within 30 days from acceptance of Contract. Ref Sch 'A' Note No 20 on page No 15. 2. Attention of bidder is invited to periodical variation in minimum fair wages as notified by Govt of India/State Govt (Whichever is more) from time to time, the rates quoted by bidder shall deemed to be inclusive of any such variation and the contractor shall pay the wages as notified by Govt during the execution of contract. No reimbursement would be admissible except for taxes directly related to contract value as covered under Special Condition 27.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs.49845.00
M/S ANIL KUMAR
M/S Hind Constructions
NEETU TRADERS (INDIA)
Shiv Enterprises
jay maa engineers
Adhunik Builders
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .