Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | ₹19.5 L Quoted ₹20.1 L | L1 | Accepted-AOC Lowest tender |
| 2 | L2₹22.3 L+₹2.2 L (10.7%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | ₹22.3 L+₹2.2 L (10.7%) | L2 | Rejected-Finance Not being lowest tender |
| 3 | L3₹22.8 L+₹2.7 L (13.3%)Rejected-Finance | ₹22.8 L+₹2.7 L (13.3%) | L3 | Rejected-Finance Not being lowest tender |
| 4 | L4₹24.2 L+₹4.1 L (20.2%)Rejected-Finance | ₹24.2 L+₹4.1 L (20.2%) | L4 | Rejected-Finance Not being lowest tender |
| 5 | L5₹24.8 L+₹4.7 L (23.5%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | ₹24.8 L+₹4.7 L (23.5%) | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20.8 L
EMD Value
₹41,600
Closing Date
22 Dec 2021, 6:00 pmClosed
GE AF TA
GE AF TA GWALIOR-474020
REPAIR/MAINT OF CEILING FANS, EXHAUST FANS AND CONNECTED WIRING AND ACCESSORIES IN TECH AREA AT AF STN GWALIOR
2021_MES_475727_2
8900/1329/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹41,600
Yes
22 Jan 2022
24 Nov 2021
30 Dec 2021
24 Nov 2021
22 Dec 2021
8 Dec 2021
Amount
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc , of any description, any sweep and from any position / locations (i.e.Technical Area's OTM Accn / hangers),sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in position after , dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades,connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’/BOQ
M&L for rewinding with super enamelled copper wire of suitable existing size/gauge including insulating material and varnishing including testing to the satisfaction and all as directed by Engineer -in- Charge for the following type of fans :-
(a) Ceiling fan 1200 / 1400 mm sweep any make.
(b) Exhaust fan 300 mm / 225 mm sweep any make.
(c) Exhaust fan 375 / 450 mm sweep any make.
(d) Wall/Cabin fan 450 mm sweep any make.
(e) Pedestal fan 400 mm sweep any make.
(f) Air circulating fan of 610 mm sweep any make.
(g) Flame proof Exhaust fan 300/400 mm sweep any make.
Supply only the following spare for replacement in fan complete all as specified and directed.
(a) Bush for the ceiling fan of any make and sweep.
(b) Ball bearing for ceiling fan/wall fan/pedestal fan/exhaust fan & Cabin fan Make : NBC/SKF/TATS
(c) Rubber reel.
(d) Split pin
(e) Condenser 2.5 MFD Make : Siemens/EPCOS/Usha
(f) -do- but 3.15 MFD
(g) -do- but 4 MFD
(h) Canopy for ceiling fan (set of 02) as per sample. Make : Khaitan/Crompton/Bajaj/Usha
(m) Regulator resistor type suitable for wall fan Make : Khaitan/Crompton/Usha.
(n) -do- but for pedestal fan
(o) MS clips (set of two) as per sample of ceiling fan
M&L for servicing of in position /after taking down i.e.requried ceiling fan/exhaust fan/cabin fan (any make any size) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber real complete and re-fixing in the same position after repair to the entire satisfaction and as directed by Engineer -in- Charge.
M&L for painting of ceiling fan including fan blade of any make of any size with one coat of synthetic enamelled paint over one coat of red oxide primer after scraping old paint and preparing surface for painting and rewriting existing MES number with black paint complete to the entire satisfaction and as directed by Engineer -in- Charge.
-Ditto- all as per BOQ Sl. No. No 5.00 above but for exhaust fan/Air circulator fan.
Supply and fixing down rod for ceiling fan made of GI pipe 15mm dia medium grade of length 0.3 to 01 meter or as required including threading, cutting slotting drilling including nut, bolt clip washer and rubber real.
S&F wall /pedestal fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
S&F Exhaust fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
S&F Exhaust fan clamp (leg) as per sample (set of 3/4) including rubber packing and clamp for bolt all as directed by Engineer-in-Charge.
Taking down unserviceable Geysers of any size and make from wall by disconnecting and sealing water line and electrical connection for annual painting/maintenance/ servicing/ overhauling/dismantling of various parts for repair/replacement/painting including carryout brazing to inner tank etc, re-assembling after repair and replacement of worn parts complete all as specified and directed
S & F GM non-return valve, 15 mm bore ISI mark complete all as specified and directed.
S & F lead cum brass alloy pipe for inlet & outlet connection 15 mm bore 450 long including check/end nuts and washer to prevent water leakage all as specified and directed.
S & F PVC pipe steel thread armoured for inlet and outlet connection, 15 mm bore 450 long all as specified and directed.
S & F vent pipe connection of 15 mm bore, light grade, GI Pipe of required length including necessary fittings complete all as specified and directed.
S & F heating element of any type, ISI marked (2.0 KW) for 50 ltrs capacity geyser all as specified and directed.
S & F heating element of any type, ISI marked (1.5 KW) for 25 Ltrs capacity geyser all as specified and directed.
S & F thermostat for 50/35/25 ltrs capacity geyser of any type and make as per sample ISI marked all as specified and directed.
S & F pressure release valve 15 mm dia suitable for 50/35/25 ltrs Geysers of any make. ISI marked all as specified and directed.
S & F syphone assembly complete with packing ring and nuts & bolts suitable for 50 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
S & F syphone assembly complete with packing ring and nuts and bolts suitable for 25 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
S & F PVC insulated copper conductor cable multi stranded 3 core 4 Sqmm flexible all as specified and directed.
S & F fusible plug made of brass having lead alloy fuse suitable for 50/35/25 ltrs capacity Geyser of any make all as specified and directed.
S & F Inner stainless steel tank for 25 ltrs capacity geyser of any make all as specified and directed.
S & F outer stainless steel tank for having 25 ltrs capacity geyser of any make all as specified and directed.
S&F in replacement 8 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary concreat work complete all as specified and directed Make :- Havells Cat Part No BAMBOOBLS8WLED830PSYMTOPC or equivalent in make of CG/Philips
Supplying & fixing in repair Integral LED Post Top Lantern 50 watt LED and accessories fixing to electric source complete and fixing GI pipe of suitable length grouting in PCC complete all as specified and directed at site. Make: Havells Cat Part No - RUBMAXIPT50WLED830PSYMTOPC /Philips/CG
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per BOQ Sl No. 28.00 here-in-before but cable of size 6 Sqmm FRLS with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit. Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit. Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
Supply, fixing in repair, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed. Make :- Legrand/Havells/C&S
Supply, fixing in repair, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 63 Amp MCB complete all as specified and directed. Make :- Legrand/Havells/C&S
Supply, fixing in repair, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) 125 Amp complete with one TPN 125 Amp MCB complete all as specified and directed. Make :- Legrand/Havells/C&S
Supply, fixing in repair, connecting & testing of sheet metal enclosures (IP-54 protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) complete with one TPN 40/63 Amp MCB complete all as specified and directed. Make :- Legrand/Havells/C&S
Supply, fixing in repair, connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.
All as per BOQ Sl. No. 39.00 here-in-before but distribution board single pole and neutral, 12 way.
All as per BOQ Sl. No.39.00 here-in-before but distribution board single pole and neutral, 8 way.
All as per BOQ Sl. No. 39.00 here-in-before but distribution board single pole and neutral, 4 way
Supply and fixing in repair factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed.
All as per BOQ Sl. No. 43.00 here-in-before but distribution board VTP & N 8 ways (TPN MCCB DB) for TPN-MCCB upto 160 Amps
All as per BOQ Sl. No. 43.00 here-in-before but distribution board TP & N 12 ways (TPN MCB DB) for TP-MCB upto 160 Amps
All as per BOQ Sl. No. 43.00 here-in-before but distribution board TP & N 8 ways (TPN MCB DB) for TP-MCB upto 160 Amps
S&F MCCB, 3 pole, 250 Amps current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
All as per BOQ Sl. No. 47.00 here-in-before but MCCB, 3 pole, 160 Amps current rating and ultimate breaking capacity Icu = 16 KA.
All as per BOQ Sl. No. 47.00 here-in-before but MCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity Icu = 16 KA
All as per BOQ Sl. No. 47.00 here-in-before but MCCB FP, 100 Amps having current rating 16 KA .
All as per BOQ Sl. No. 47.00 here-in-before but MCB TPN, 63 Amps (`C’ series) having current rating 10 KA .
All as per BOQ Sl. No. 47.00 here-in-before but MCB TP, 40 Amps (`C’ series) having current rating 10 KA .
S&F MCCB, 4 pole, 125 Amps,415 volt current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
All as per BOQ Sl. No. 53.00 here-in-before but MCB SPN, 40 Amps (`C’ series) having current rating 10 KA
All as per BOQ Sl. No. 53.00 here-in-before but MCB SPN, 32 Amps (`C’ series) having current rating 10 KA
All as per BOQ Sl. No. 53.00 here-in-before but MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA.
Supply, Laying & connecting cable 06 Sqmm 2 Core 1100 Volts grade, stranded aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cable of following sizes conforming to IS 7098 (Part-I) amended upto date complete all as specified and directed for the follwoing sizes:- Note :- (i). Lugs/Glands/saddles of suitable size required for fixing of cables in panels/junction boxes /on walls shall be included in the item rate. (ii) Cable path indicators shall be provided at every 50 mtr intervals of the cable is deemed to included in the item rate.
(a) 6 Sqmm 4 Core
(b) 10 Sqmm 4 Core
(c) 16 Sqmm 4 Core
Excavation in trenches in soft in loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick after the cables are laid, jointed & tested complete all as specified and directed
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. Note :- Only punned thickness shall be measured for payment
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat ISI marked of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge. Make :- Mahatab/Ravi/Duracoat
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board,outlet box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :-
(a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per BOQ Sl. No. 64.00 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F switch piano flush type single pole one way 5 Amps 230 V all as specified.
S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurposeall as specified.
All as per BOQ Sl. No. 67.00 above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) all as specified.
S&F socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type all as specified.
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in repairs lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
Supply& Fixing in repairs LED Batten fittings 20 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 20W , D532065 of Wipro or Equivalent model of Philips/Havells
M/s A.K. Trading Co.
m/s varsha traders
Mukesh Enterprises
M/s Anupam Construction Co.
M/s DN Gupta and Company
M/s Yashika Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .