REPAIR/REPLACEMENT OF EARTHING OF LT PANEL BOARDS AND LT SWITCH GEAR AND CONNECTED WORK AT MES MD ACCN AND BASRA AREA, REPAIR/REPLACEMENT OF CHEMICAL AND COPPER EARTHING AND CONNECTED WORK AT TECHNICAL AREA, REPAIR REPLACEMENT OF DISTRIBUTION PIPE LI
2026_MES_797336_1
C/8999/2026-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹71,000
Yes
4 Nov 2026
4 Nov 2026
2 Dec 2026
4 Nov 2026
25 Nov 2026
18 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for earthing of machinery/equipment installed at power house/Sub Stn/ DB complete with galvanised steel earth plate electrode 60 × 60cm × 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including galvanised earth lead wire 4.0mm, 15mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion including taking out/dismantling of old unserviceable earthing of any description, complete all as specified and as directed.
Note :- (i) Earth lead wire/strip beyond 7.5 mtr shall be measured and paid separately.
(ii) On testing, after completion, if the earth resistance <2 ohms is not obtained, earthing shall be regenerated at no extra cost till the desired earth resistance is obtained. (iii) locally available best quality soil to beused all around the earth plate electrode (along periphery of solt, charcole, chemical etc) min covered vol 450 x 450 x 450mm included in unit quoted rate. | 8 | Each Set | - | - |
| 2 | All as per item No 1.00 here-in- before but using GI earth strip of size 32 x 6mm as earth lead and 40mm boe (medium grade) galvanized iron pipe for protection of earth lead, complete all as specified and directed. | 20 | Each Set | - | - |
| 3 | M&L for earthing of equipment at power house/Sub Stn/DB complete with copper earth plate electrode 60 × 60cm × 3.00mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel in any type of soil, connected to earthing test point and and necessary excavation and earth work, PCC (1:2:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including Copper earth strip 20 x 3.00mm, protected by 40mm bore (medium grade) galvanized iron pipe up to earthing test point including disposal of soil to a distance not exc 50 mtr and necessary testing on completion, complete all as specified and directed.
Note:- (i) Proper earthing pit should be provided with pit cover.
(ii) On testing, after completion, if the earth resistance <2 ohms is not obtained, earthing shall be regenerated at no extra cost till the desired earth resistance is obtained. (iii) locally available best quality soil to beused all around the earth plate electrode (along periphery of solt, charcole, chemical etc) min covered vol 450 x 450 x 450mm included in unit quoted rate. | 13 | Each Set | - | - |
| 4 | All as per item No 3.00 here-in before but using magnesium-sulphate in lieu of common solt, complete all as specified and as directed. | 3 | Each Set | - | - |
| 5 | All as per item No 3.00 here-in before but using copper-sulphate in lieu of common solt, complete all as specified and as directed. | 3 | Each Set | - | - |
| 6 | S&F in replacement 32 x 6mm Gl strip in short pieces on surface or in recess for inter connecting, complete all as specified and directed. | 50 | RM | - | - |
| 7 | All as per item No 6.00 here-in before but copper strip 20 x 3.00mm, complete all as specified and as directed. | 180 | RM | - | - |
| 8 | All as per item No 6.00 here-in before but copper strip 32 x 6.00mm, complete all as specified and as directed. | 100 | RM | - | - |
| 9 | All as per item No 6.00 here-in before but galvanised wire 4mm dia, complete all as specified and as directed. | 50 | RM | - | - |
| 10 | All as per item No 6.00 here-in before but aluminuium strip 25 x 3mm, complete all as specified and as directed | 50 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_894371.xls
BOQ • 2.24 MB
Tender8999.pdf
Tender Documents • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .