REPAIR MAINTENANCE TO COOLING APPLIANCES SUCH AS ALL TYPES OF ACs, WATER COOLERS, REFRIGERATORS, DEEP FREEZERS, HUMIDIFIERS, VOLTAGES STABILIZERS ETC AT AFH AND AFS UNDER GE (AF) JORHAT.
2022_MES_564311_1
8992/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) JORHAT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹60,000
Yes
3 Feb 2023
21 Nov 2022
19 Dec 2022
21 Nov 2022
17 Dec 2022
3 Dec 2022
Amount
M&L for servicing of 1.5/2.0/3.0 TR capacity window/split type AC after disconnecting from electric supply, opening suction & dicharge pipes of outer unit , and removing scratch, dust with iron brush,cleaning condensor unit,compressor, cooling coil/cleaning of fan blade/ cleaning of filter of inner unit etc,with water & air blower including (checking thermostate, starting capacitior, running capacitor) and reinstalling the same at the desired places complete all as specified and directed. Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
Taking down/up defective AC (Window/Split Type) 1.5 TR Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt rotary type Compressor Sealed Unit and providing new Compressor of same Capacity and same make, Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric Connections and Testing, complete all as specified and directed. MAKE : KIRLOSKAR/EMERSION/TECUMSEH Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
All as per Item No. 2 above but AC (Window/Split Type) 2.0 TR Capacity. Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
Taking down/up defective AC (Window/Split Type) 1.5 TR Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt reciprocating type Compressor Sealed Unit and providing new Compressor of same Capacity and same make, Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric Connections and Testing, complete all as specified and directed. MAKE : KIRLOSKAR/EMERSION/TECUMSEH Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
All as per Item No. 4 above but AC (Window/Split Type) 2.0 TR Capacity. Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
S&F Fan Motor of AC (Window/Split Type) 1.5 TR Capacity of approved Make and sample of required Size to suit existing AC including Taking out the unserviceable Fan Motor from AC complete all as specified and directed. MAKE : AUE / FRAGMETER / GE
S&F Fan Motor of AC (Window/Split Type) 2.0 TR Capacity of approved Make and sample of required Size to suit existing AC including Taking out the unserviceable Fan Motor from AC complete all as specified and directed. MAKE : AUE / FRAGMETER / GE
S&F Air Circular Blower Fan Motor of AC (Split Type) 1.5 TR Capacity of approved Make and sample of required Size including Taking out unserviceable Air Circular Blower Fan Motor from AC complete all as specified and directed. MAKE : VOLTAS/LG/AMTEX/HITACHI
S&F Air Circular Blower Fan Motor of AC (Split Type) 2.0/3.0 TR Capacity of approved Make and sample of required Size including Taking out unserviceable Air Circular Blower Fan Motor from AC complete all as specified and directed. MAKE : VOLTAS/LG/AMTEX/HITACHI
S&F Remote Circuit Board including senser and display with Remote of AC (Split Type) 1.5/2.0 TR Capacity non Inverter type (as per Sample/ Site Requirement) and taking out unserviceable Remote Circuit Board, senser and display from AC, complete all as specified and directed. MAKE : AMTREX/LG/VOLTAS/HITACHI
S&F Remote Circuit Board including senser and display with Remote of AC (indoor unit) 1.5/2.0 TR Capacity Inverter type (as per Sample/ Site Requirement) and taking out unserviceable Remote Circuit Board, senser and display from AC, complete all as specified and directed. MAKE : AMTREX/LG/VOLTAS/HITACHI
S&F Remote Circuit Board including senser and display with Remote of AC (outdoor unit) 1.5/2.0 TR Capacity Inverter type (as per Sample/ Site Requirement) and taking out unserviceable Remote Circuit Board, senser and display from AC, complete all as specified and directed. MAKE : AMTREX/LG/VOLTAS/HITACHI
S&F Capacitor 36 mfd – 45 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Capacitor from AC complete all as specified and directed. MAKE : ELECTRO/UNIVERSAL/TIBCON
S&F Fan Motor Capacitor 6 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Fan Motor Capacitor from AC complete all as specified and directed. MAKE : ELECTRO/UNIVERSAL/TIBCON
S&F Starting relay of AC (Window/split type) 1.5/2.0/3.0 TR capacity including taking out unserviceable Starting relay from AC complete all as specified and directed.
S&F Thermostat switch of AC (Window/split type) 1.5/2.0/3.0 TR capacity including taking out unserviceable Thermostat switch from AC complete all as specified and directed. MAKE : INFOSS/ANNAPURNA/RENOLT
Supply and filling Gas with R-22 Gas of AC (Window/Spilt Type) 1.5/2.0/3.0 TR Capacity with required quantity and as suitable for Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required complete all as specified and directed.
Supply and filling Gas with R-32/R-134/R-407/R-410 Gas of AC (Window/Spilt Type) 1.5/2.0/3.0 TR Capacity with required quantity and as suitable for Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required, complete all as specified and directed.
Re-installation and re-commissioning AC (Split type/window) (1.5TR, 2.0TR, 3.0TR) capacity and electric driven (single phase) comprising for split type AC one inner unit, one outer unit with servicing and installed at site including making connection with copper tubes from inner unit to outer unit including filling of refrigerant gas and connecting electrically and testing, complete all as specified and directed.
S&F Mild steel stand with shed as per existing for testing AC (window type / split type) 1.5 to 2.0 TR capacity grouting with brick wall with mild steel expandable bolts with steel rawl plug including making good walls in cement mortar 1:3 as required including dismantling old unserviceable mild steel stand for ACs complete all as specified and directed.
S&F Lexic MCB single pole, 230 volts, 32 Amps, 10 KA, C Curve complete all as specified and directed.
Supply, installation and testing Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130V to 250V with output voltage stabilzed at 230 V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed
S&F Copper capillary tube 5/8" as suitable size for repairing window/split type AC including necessary gas welding complete all as specifiesd and directed.
S&F Copper capillary tube 1/2" as suitable size for repairing window/split type AC including necessary gas welding complete all as specified and directed.
S&F Copper capillary tube 1/4" as suitable size for repairing window/split type AC including necessary gas welding complete all as specified and directed.
All as per item No. 26 above but capacity 210/315 ltr. complete all as specified and directed.
S&F Ice Cooling Chamber (as Approved) for Refrigerator 210/315 LITRE Capacity including Taking down unserviceable Ice Cooling Chamber from Refrigerator, complete all as specified and directed.
S&F Starting Relay (OPEN TYPE/BOX TYPE) for Refrigerator of any description including Taking down Unserviceable Starting Relay from Refrigerator, complete all as specified and directed.
Supply only chiller tray for refrigerator for 300 ltrs capacity complete all as specified and directed.
Supply only chiller tray for refrigerator for 165 ltrs capacity complete all as specified and directed.
Supply only vegitable tray for refrigerator for 165 ltrs capacity complete all as specified and directed.
Supply only vegitable tray for refrigerator for 286/300 ltrs capacity complete all as specified and directed.
Supply only PVC refrigerator stand suitable for 286/310 ltrs refrigerator capacity complete all as specified and directed. MAKE : KELVINATOR/ GODRAJ/ LG
Supply only PVC refrigerator stand suitable for 165 ltrs refrigerator capacity complete all as specified and directed. MAKE : KELVINATOR/ GODRAJ/ LG
S&F 15mm bore Bib tap Cast copper alloy "chromium plated" Push type complete all as specified and directed.
S&F PVC Connection pipe with brass unions at both ends with brass nuts, suitable for fixing to 15 mm bore GI Pipe complete all as specified and directed.
S&F 15 mm bore PVC float valve with epoxy coated aluminium arm with PVC Polythene ball suitable for water coolers complete all as specified and directed.
S&F PVC Polythene ball suitable for fix to 15 mm PVC float valve complete all as specified and directed.
S&F PVC drain out pipe 25 mm bore as per existing by providing necessary GI clamps nuts bolts etc. complete all as specified and directed.
S&F AC outdoor unit of 1.5/2.0 TR capacity as required complete all as specified and directed.
M&L for replacement of base plate of water cooler of any capacity, made out of 2 mm thick MS sheet and painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
All as per Item No. 44 above but WATER COOLER of 120/150 ltrs capacity complete all as specified and directed.
S&F AC indoor unit of 1.5 / 2.0 TR capacity as required complete all as specified and directed.
M&L for rewinding fan motor of existing water cooler 40/80 and 120/150 litre Capacity with suitable size Copper wire including taking out unserviceable copper winding from fan motor of water cooler complete all as specified and directed.
S&F Starting Relay for Water Cooler 40/80/120/150 litre capacity including taking out unserviceable Starting Relay from Water Cooler, complete all as specified and directed.
M&L for overhauling of Voltage Stabilizer of 1.0 KVA, 2.0 KVA /3.0 KVA & 5 KVA capacity of any make including replacement of defective relays, capacitors, switches, voltmeters and testing complete all as specified and directed.
S&F Condenser coil for Split AC 1.5/2.0 TR capacity including taking down old unserviceable condenser coil complete all as specified and directed.
S&F Condenser coil for Refrigerator 210/310 ltr capacity including taking down old unserviceable condenser coil complete all as specified and directed.
M&L for insullation to copper tubing of size 1/4" / 1/2" as per sample approved complete all as specified and directed.
S&F 20 mm dia flexible pipe complete all as specified and directed.
S&F flexible PVC cable 6 sqmm, 4 core PVC insulated copper multi-stranded FRLS conductor, drawn through PVC casing caping / PVC conduit with all accessories as required, complete all as specified and directed.
S&F PVC plug top of 16 Amp suitable for the geyser complete all as specified and directed.
S&F Sheet Metal Enclosures with three pin socket and top with one MCB double pole 20 Amps, 40 volts 50Hz complete all as specified and directed. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
HEMONTA DAS
Bidder Name
HEMONTA DAS
M/S DHAR AND DHAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .