| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.7 L+₹64,506 (4.27%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹17.5 L+₹2.4 L (16.0%)Rejected-Finance HOUSE NO 97 MOHALLA AFGHANA GALI KRISHAN DWARA JAMMU | JAMMU | JAMMU | JAMMU AND KASHMIR | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹18.3 L+₹3.2 L (21.1%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹19.3 L+₹4.2 L (27.7%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
24 Jun 2020, 6:00 pmClosed
G E North Akhnoor
G E North Akhnoor
REPAIR MAINT OF LT PANEL FEEDER PILLER BOX AND CONNECTING WORKS AT TANDA AREA UNDER GE NORTH AKHNOOR
2020_MES_347785_1
GE(N)/AKH-09/2020-21
Open Tender
Civil Works
Item Rate
120 days
Akhnoor
E Class Cat b i
8 documents required · 8 mandatory
₹500
G E North Akhnoor
₹50,000
Yes
19 Oct 2020
27 May 2020
26 Jun 2020
27 May 2020
24 Jun 2020
11 Jun 2020
Amount
Supply installation and commissioning and testing of LT pannel CPRI approved cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, out dor type factory made, duly powder coated inside and out side, outer shell, internal shell and partition made out of 2 mm thick CRCA sheet, with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable door, weather proof and vermin proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 45 cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc.MCCB's should be Thermal magnetic releae, adjustable over load should be 80-100% and Ics= 100% Icu, confirming to IS/IEC 60947-2 complete comprising of following complete all as specified and directed by Engineer-in-Charge.
Supply installation and commissioning and testing of LT pannel CPRI approved cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, out dor type factory made, duly powder coated inside and out side, outer shell, internal shell and partition made out of 2 mm thick CRCA sheet, with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable door, weather proof and vermin proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 45 cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc.MCCB's should be Thermal magnetic releae, adjustable over load should be 80-100% and Ics= 100% Icu, confirming to IS/IEC 60947-2 complete comprising of following complete all as specified and directed by Engineer-in-Charge.
Supply installation and commissioning and testing of LT pannel CPRI approved cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, out dor type factory made, duly powder coated inside and out side, outer shell, internal shell and partition made out of 2 mm thick CRCA sheet, with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable door, weather proof and vermin proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 45 cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc.MCCB's should be Thermal magnetic releae, adjustable over load should be 80-100% and Ics= 100% Icu, confirming to IS/IEC 60947-2 complete comprising of following complete all as specified and directed by Engineer-in-Charge.
Supply installation and commissioning and testing of LT pannel CPRI approved cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, out dor type factory made, duly powder coated inside and out side, outer shell, internal shell and partition made out of 2 mm thick CRCA sheet, with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable door, weather proof and vermin proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 45 cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc.MCCB's should be Thermal magnetic releae, adjustable over load should be 80-100% and Ics= 100% Icu, confirming to IS/IEC 60947-2 complete comprising of following complete all as specified and directed by Engineer-in-Charge.
Supply and Laying for XLPE insulated armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 185 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply and Laying for XLPE insulated armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm, 3.5 core, complete all as specified and directed by Engineer-in-Charge
Supply and Laying for XLPE insulated armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 300 Sqmm, 3.5 core, complete all as specified and directed by Engineer-in-Charge
Excavation in trenches n.exc 1.5 Mtr wide and n.exc 1.5Mtr depth and getting out for errection of LT poles, stay assembly and laying of cable etc in soft/loose soil complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engineer-in-Charge
Removing of excavated material to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge
M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified
M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the length of brick complete all as specified .
Dismentling of partialy rusted panel, removing of MCCB;s Bus bar, all accessories and refixing the same with suitable size of Thimbles, Nuts and bolts after welding works, painting all as specified and directed by Engineer-in-Charge.
Time switch astro type (having longitude and latitude of Indian citiesmemory) 415 V, Three Phase of 40 Amp rating with contactor fitted inside sheet metal enclosure, complete all as specified and as directed.
Taking out and Replacement of following old unserviceable, worn out MCCB's in the existing Panel as under as under :-
Supply and Fixing of MCCB, four pole, 36 KA, 400 Amp
Supply and Fixing of MCCB, four pole, 36 KA, 320Amp
Supply and Fixing of MCCB, four pole, 25 KA, 250 Amp
Supply and Fixing of MCCB, four pole, 25 KA, 200 Amp
Supply and Fixing of MCCB, four pole, 25 KA, 160 Amp
Supply and Fixing of MCCB, four pole, 25 KA, 125Amp
Supply and Fixing of MCCB, four pole, 25 KA, 100 Amp
Supply and Fixing of MCCB, four pole, 25 KA, 63Amp
Supply and Fixing of MCB, Single pole, 32 Amp
Supply and Fixing of MCB, Single pole, 40 Amp
Supply and Fixing of MCB, Single pole and Neutral, 32 Amp
Supply and Fixing of MCB, Single pole and Neutral, 40 Amp
Taking down old unserviceable LT panel and transport to MES store.
Taking out and Replacement of following old unserviceable, worn out different type Change Over switches as follows:
Supply and Fixing of On load Change over switch in sheet steel enclosur, Four pole, 63 Amp
Supply and Fixing of On load Change over switch in sheet steel enclosur, Four pole, 100 Amp
Supply and Fixing of On load Change over switch in sheet steel enclosur, Four pole, 200 Amp
Supply and Fixing of Off load Change over switch in sheet steel enclosur, Four pole, 63 Amp
Supply and Fixing of Off load Change over switch in sheet steel enclosur, Four pole, 100 Amp
Supply and Fixing of Off load Change over switch in sheet steel enclosur, Four pole, 200 Amp
Usha Engineering Co.
M/S RAVI KUMAR
VIJAY BUILDERS
Nitika electricals and engineers works
M/S SAHNI CONSTRUCTION CO
Jiwan Singh
M/S SUMEET TRADING CORP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .