| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | ₹34.5 L Quoted ₹35.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹40.3 L+₹4.4 L (12.3%)Rejected-Finance | ₹40.3 L+₹4.4 L (12.3%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Withdrawn by Contractor |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Apr 2023, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIRS/MAINT OF SPLIT/ WINDOW TYPE AC, WATER COOLER, DESERT COOLER, DEEP REEZERS AND REFRIGERATOR, REWINDING/ OVERHAULING OF CEILING FAN/EXHAUST FAN AND MISC ITEMS OF E/M WORKS AT AF STN JAISALMER
2023_MES_585796_1
8889/GE/E8
Open Tender
Miscellaneous Works
Lump-sum
270 days
GE (AF) Jaisalmer
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹70,000
Yes
8 May 2023
14 Mar 2023
13 Apr 2023
14 Mar 2023
11 Apr 2023
28 Mar 2023
15 Mar 2023 - 17 Mar 2023
Amount
Cleaning of complete body including fitting and fixture of desert cooler of capacity 4000/5000 Cum/hours of any make with wire including removal of all sludges, loose paint dust, dirt etc and prepared the clean surface for painting, and applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, including rewriting of MES No etc complete all as specified and directed.
Taking out fan motor single phase, 230 Volts, 1400 RPM, 3 Speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and re-fixing in same position ccomplete all as specified and directed
Front grill/louvers to desert cooler made out from 0.80 mm thick Galvanised Iron sheet suitable for 5000/4000 Cum/hours capacity desert cooler of any make fixed in repair complete all as specified and directed.
Wood pad, minimum weight 0.80 Kg, fixed in side panels of desert coolers including taking down old unserviceable complete all as specified and directed.
Desert cooler motor of three speed, 1380 RPM, 230 volts, copper winding single phase with aluminium fan blade, ring, side legs, necessary bolts and nuts of capacity 1/6 to 1/8 HP including taking down old unserviceable complete all as specified and directed.
Plug top, three Pin, 5/6 Amps, 230 volts, ISI Marked including taking down old unserviceable complete all as specified and directed.
Switch piano type, 240 volts, Singe Pole, one ways, 5/6 Amps, ISI Marked, fixed in desert coolers including taking down old unserviceable complete all as specified and directed.
PVC insulated and sheathed round flexible three core copper conductor cable of size 1.50 sqmm including necessary connection fixed in desert coolers including taking down old unserviceable complete all as specified and directed.
Capacitor 4 MFD for fan motor of desert cooler with ISI Marked including taking down old unserviceable complete all as specified and directed.
Mild Steel Sheet body of 22 gauge suitable for coolers of capacity 4000/5000 Cum/hour including taking down old unserviceable complete all as specified and directed.
Side shutter made out from 0.80 mm thick galvanised iron sheet of capacity 4000/5000 cum/hours desert cooler fixed as in repair complete all as specified and directed.
Submersible water lifting pump heavy duty suitable for desert cooler of capacity 4000/5000 cfm, 230 Volts 50 Hz Single Phase, including suitable size PVC three way distributor and PVC pipe of suitable size with elbow and bends including taking down old unserviceable water pump complete all as specified and directed.
Aluminium heavy duty Fan blade with bush powder coated for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed.
PVC heavy duty Fan blade with bush for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed.
Cast Iron ring of cooler Fan motor Leg set (RH & LH) with clamps suitable for desert cooler complete with nuts & bolts including taking down old unserviceable complete all as specified and directed.
15mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock fixed in repair complete all as specified and directed.
Water tank suitable for desert cooler of capacity 5000/4000 cum/hour, fabricated with 1.00 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness and apply one coat of red oxide primer including taking down old unserviceable complete all as specified and directed.
Preparation of old painted surface of capacity 40/80, 60/120 & 150/150 litre water cooler, externally and internally including compressor chamber, motor and applying one coat of synthetic enamel paint with applying one coat of synthetic enamel paint with spray machine complete all as specified and directed.
Taking down Condenser Fan Motor from water cooler of capacity 40/80, 60/120 & 150/150 litres and rewinding the same with super enameled copper winding wire same gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams including taking down existing complete all as specified and directed.
15mm bore water tap (Internal thread), cast copper alloy, chromium plated push type suitable for water cooler of any capacity fixed as in repair complete all as specified and directed.
Thermostat suitable for water cooler of any capacity fixed in repair complete all as specified and directed.
Waste water adaptor PVC, 32mm size suitable for water cooler of any capacity fixed as in repair complete all as specified and directed.
Relay with Over Load Protector suitable for 40 to 150 liters cooling capacity water cooler complete all as specified and directed.
PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity fixed as in repair complete all as specified and directed.
Galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete, fixed to walls and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
New freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning including cutting and removing old unserviceable freezer unit of refrigerator capacity 165/170/175/300/310/510 litres of any make complete all as specified and directed .
Thermostat suitable for refrigerator of capacity 165 to 180 liters fixed as in repair complete all as specified and directed .
Compressor suitable for water cooler of capacity 40/80 litre/hour as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
Compressor suitable for water cooler of capacity 60/120 litre/hour as required including necessary connections and and testing fixed as in repair including taking down old unsv complete all as specified and directed .
Compressor suitable for water cooler of capacity 150/150 litre/hour as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed .
Compressor suitable for Refrigertor of capacity 165/175/185 litre as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
Compressor suitable for Refrigertor of capacity 285/300/310 litre as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed
Condensing coil suitable for water cooler of capacity 40/80, 60/120 & 150/150 litre fixed as in repair including taking down old unsv complete all as specified and directed .
Supply only refrigerant gas R-290/R-22 for charging where required at site as per direction .
Supply only refrigerant gas R-32/R-410a/R-134a/R-407c for charging complete all as specified and directed ..
Servicing of Deep freezer of capacity 265/320/492 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and directed .
Preparation of external old painted surface of Deep freezer of capacity 405/492 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and directed.
Compressor suitable for Deep Freezer of capacity 300/320 litre/hour as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
Compressor suitable for Deep Freezer of capacity 500 litre/hour as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
Condenser coil suitable for Deep freezer of capacity 325 Litres fixed as in repair including taking down old unsv complete all as specified and directed ..
Finding out the leakage with the pressure test of condenser or cooling coil of water cooler capacity 40/80, 60/120 & 150/150 litre cooling/storage and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/ soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed.
Finding out the leakage with the pressure test of the condenser or cooling coil of Rerigerator of capacity 165/170/175/300/310 litres and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed.
Cooling coil suitable for Deep freezer of capacity 300/500 liters fixed as in repair including taking down old unsv complete all as specified and directed
Condenser coil assembly suitable for Split type Air Conditioner 1.5/2.0 TR fixed as in repair including taking down old unsv complete all as specified and directed.
Condenser coil Assembly 1.5/2.0 TR suitable for window type Air Conditioner fixed as in repair including taking down old unsv complete all as specified and directed.
Coil Evaporator Assembly suitable for 1.5/2.0 TR window type Air Conditioner fixed as in repair including taking down old unsv complete all as specified and directed.
Condenser Motor (Outdoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
Condenser Motor (Outdoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR non inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
Blower Motor (Indoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR non inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
Blower Motor (Indoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR inverter type AC fixed as in repair including taking down of old unsv motor complete all as specified.
Swing motor suitable for split air conditioner of capacity 1.5/2.0 TR invertor and non invertor type fixed as in repair including taking down old unsv complete all as specified and directed.
Condenser/evaporator motor for window Air Conditioner of Capacity 1.5/2.0 TR inverter and non inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
Servicing of split type Air Conditioner of capacity 1.5/2.0 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking / testing of all parts for its serviceability, and oiling/greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete unit including testing for smooth functioning complete all as specified and directed. Note : (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Sch 'A' price schedule (ii) Any spare part of AC if found defective will be measured as supply and fix fixed in repairs under respective item of this Sch 'A' price schedule.
Servicing of window type Air Conditioner of capacity 1.5/2 TR of any type or make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking/testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn-out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed. Note : (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Sch 'A' price schedule (ii) Any spare part of AC if found defective will be measured as supply and fix fixed in repairs under respective item of this Sch 'A' price schedule.
Remote control (Micro processor) unit suitable for split type Air Conditioner 1.5 / 2.0 TR capacity of make AMTREX/as per existing complete with wires of remote fixed in repair complete all as specified and directed.
Shifting of Split type Air Conditioner 1.5/2.0 TR from one side to another by completely removing it from the existing place wihout any damage,and shifting it to new site including gas charging to required level comissioning and testing complete all as specified and directed.
Shifting of Window type AC 1.5/2.0 TR from one site to another by completely removing it from the existing place wihout any damage, and shifting it to new site making necessary cuttung in the wall making it good, including gas charging to required level comissioning and testing complete all as specified and directed.
Suction lines copper pipes of suitable size as per site requirement fixed as in repair complete all as specified and directed.
Discharge lines copper pipes of suitable size as per site requirement fixed as in repair complete all as specified and directed.
Sleeve foam Protection suitable for Split type Air Conditioner 1.5/2.0 TR for both suction and discharge line fixed as in repair complete all as specified and directed.
Factory made PVC drain pipe suitable for Split type Air Conditioner 1.5/2.0 TR with coupler Joint fixed in repair complete all as specified and directed.
Condenser fan motor from split type Air Conditioner of capacity 1.5/2.0 TR, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts complete all as specified and directed.
Running capacitor, 55+2.5/6 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed.
Running capacitor, 45+2.5/4 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed.
Starting capacitor 2.50 MFD suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed.
Aluminium/PVC fan blade suitable for condenser/blower of window/Split type Air Conditioner of any capacity of any type or make fixed as in repair complete all as specified and directed.
PVC fan blade suitable for condenser of split type Air Conditioner of any capacity of any type (Invertor or non invertor type) or make fixed as in repair complete all as specified and directed.
Condenser unit (outdoor unit) 1.5TR including taking down old unsv complete all as specified and directed.
Starting relay only suitable for window/split type Air Conditioner 1.5/2.0 TR capacity of any type or make fixed as in repair complete all as specified and directed.
Over load protector only suitable for window/split type Air Conditioner 1.5/2.0 TR capacities of any type or make fixed as in repair complete all as specified and directed.
Supply, installation and testing of rotary compressor sealed unit for window type Air Conditioner of capacity 1.5/2.0 TR including testing for smooth functioning including taking down old unserviceable compressor complete all as specified and directed.
Supply & installation of rotary compressor sealed unit for split type Air Conditioner of capacity 1.5/2.0 TR, (non invertor type) including testing for smooth functioning including taking down old unserviceable compressor complete all as specified and directed.
Supply & installation of rotary compressor sealed unit for split type Air Conditioner of capacity 1.5/2.0 TR, (invertor type) including testing for smooth functioning including taking down old unserviceable compressor complete all as specified and directed.
Supply and fixing in replacement of complete evaporator unit (indoor unit) 1.5TR including taking down old unsv complete all as specified and directed.
Thermostat suitable for window/split type Air Conditioner 1.5/2.0 TR capacity fixed as in repair complete all as specified and directed.
Cooling fan motor of capacity 1/30 HP or 1/20 HP from split type Air Conditioner, rewinding the same with supper enamelled copper winding wire of existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush and side rubber ring and removing and re-fixing in original position complete including testing complete all as specified and directed.
Removing unserviceable window/split type Air Conditioner checking its leakage by filling of N2 gas, brazing and completely arresting its leakage, gas charging and testing complete all as specified and directed. Note : Gas charging shall be measured and paid separately.
Cooling coil suitable for window/split type Air Conditioner of capacity 1.5/2.0 TR including checking its leakage, brazing and completely arresting its leakage, gas charging and testing of any type or make fixed in repair complete all as specified and directed.
Wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS three core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity inclduing taking down old unserviceable complete all as specified and directed.
Contactor 16 Amp, suitable for split/window type Air Conditioner upto 2.0TR fixed as in repair complete all as specified and directed.
Contactor 6 to 12 Amp,suitable for split/window type Air Conditioner upto 1.5 TR fixed as in repair complete all as specified and directed.
Over load relay 3 Pole, 5 to 16 Amps suitable for split/windwo type Air Conditioner upto 2.0 TR fixed as in repair complete all as specified and directed.
Universal Cordless Remote For any type of window/Split type Air Conditioner 1.5/2.0 TR fixed as in repair complete all as specified and directed.
Voltage stabilizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 130 V to 300 V with output voltage stabilized at 230V + 2.5% and of capacity 5.0 KVA complete all as specified and directed.
PCB Plate for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (non invertor type) any type of Make fixed as in repair complete all as specified and directed.
M&L for repair of PCB Plate for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (non invertor type) any type of Make fixed as in repair complete all as specified and directed.
PCB Plate complete set for indoor and outdoor unit for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (invertor type) any type of Make fixed as in repair complete all as specified and directed.
PCB Plate for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (invertor type) any type of Make fixed as in repair complete all as specified and directed.
Condenser unit of cold storage of capacity 4 TR including testing and taking down old unsv unit complete all as specified and directed. Note : Old u/s unit shall be deposited to MES store yard.
Metal claid Top Plug and socket of Capacity 20 Amp 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
Power socket 15 Amp suitable for metal clad box, ISI Marked including taking down old unserviceable complete all as specified and directed.
Power plug top, ISI Marked including taking down old unserviceable complete all as specified and directed.
Factory made bracket with powder coated, fixed on wall with necessary grouting MS nut, bolt and washer or fastener as per site requirement for installation of outdoor unit of 1.5/2.0 TR split AC and making good disturbed surfaces, including taking down of old u/s bracket complete all as specified and directed.
Capillary of size 31, 36, 40, 50 & 80 No including taking down old unsv complete all as specified and directed
Suction line brass valve suitable for split air conditioner of capacity 1.5/2.0 TR complete all as specified and directed.
Discharge line brass valve suitable for split air conditioner of capacity 1.5/2.0 TR complete all as specified and directed.
PTFE Thread Seal Tape 12mmx10m complete all as specified and directed.
Taking down carefully and dismantling of ceiling fan/wall mounted fan/ pedestal fan/ exhaust fan of any make or model and sweep by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor burnt windings flexible cord, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing etc, reassembling & testing the fan complete all as directed. Note:- (i) Minor spare Parts i.e locking nuts & mechine screws with spring washer, bolt included in quoted rates. (ii) Spare Parts/accessories found unserviceable & required to be replaced shall be measured and paid for separately under relevant items as “Supply only”. (iii) Rewinding shall also be measured & paid for separately.
Rewinding of ceiling Fan of size 1200mm/1400mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed.
Rewinding of exhaust Fan of size 230/300mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components including testing complete all as specified and directed.
Rewinding of wall mounted Fan of size 450/550 mm sweep, 230 volts, 50Hz, AC including removal of existing burnt windings carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding the same with super enmelled copper winding wire of same gauge, same weight and same number of turns as that of existing and connecting the coils suitable to operate, capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush, rubber bush/bolt, capacitor, flexible cord, shaft and painting including assembling after lubricating movable components including testing complete all as specified and directed. Note:- Serial item No. 101.00 to 103 above bearing/Gunmetal bush/rubber bush bolt/capacitor/cord flexible wire/shaft/painting shall be measured and paid separately under respective items.
Supply only PVC flexible copper conductor, twin core size 23/0.0076 complete all as specified and directed.
Supply only capacitor of 2.50 Mfd 440/500 volts suitable for ceiling Fan complete all as specified and directed.
Supply only capacitor of 4.0 Mfd 440/500 volts suitable for Ceiling/Exhaust/Wall mounted Fan complete all as specified and directed.
Supply only ball bearing suitable for Ceiling Fan of any Sweep any make / model complete all as specified and directed.
Supply only ball bearing suitable for Exhaust Fan / wall mounted Fan any make / model / sweep complete all as specified and directed.
Supply and fix in repairs exhaust fan motor suitable for exhaust fan of 300 mm sweep all as specified and directed.
Supply and fix in repairs exhaust fan motor suitable for exhaust fan of 450 mm sweep all as specified and directed.
Supply and fix in repairs exhaust fan PVC blade suitable for exhaust fan of 300 mm sweep all as specified and directed
Supply only gunmetal bush suitable for ceiling Fan/wall mounting Fan of any make/ model/ sweep of size 1200/1400mm and Exhaust Fan of any sweep all as specified and directed.
Supply only rubber bush/bolt suitable for Ceiling Fan of any make/model /sweep of 1200/1400 mm all as specified and directed.
Supply only shaft suitable for ceiling fan / Exhaust fan/ wall mounted fan of any make/model and sweep with necessary machining work complete all as specified and directed.
Grouting in the bottom of the fan by lathe for fitting of bearing in bottom with bushing and all as directed.
Taking down copper/aluminium point wiring (light,fan,socket or power) complete, including fixture and fittings such as switches,ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls,floors etc complete all as specified and directed. Note:- (i) Old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit. (ii) Serviceable material will be reuse at site.
Taking down old seviceable distribution board of any size and any capacity including MCB abd MCCB's and making good, match the disturbed surfaces with existing surface complete all specified and directed. Note:- (i) Old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit.
Taking down sub main wiring of any type and size including batten/conduit casing capping for renewal/replacement and making good the disturbed surfaces to the exisitng surface complete all as specified and directed.
Point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC meduim duty casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in & including factory made MS/pressed steel terminal box with zinc coated duly concealed in wall for mounting fittings like switches, sockets, fan regulators etc with and including 3mm thick plastic laminated sheet top cover, complete all as specified & directed.
All as per serial item No. 120.00 here-in-before but for one bell/buzzer point controlled by one bell push.
All as per serial item No. 120.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 120.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board.
All as per serial item No. 120.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 /6 Amp switch on same board.
Point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC meduim duty casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in & including factory made MS/pressed steel terminal box with zinc coated duly concealed in wall for mounting fittings like switches, sockets, fan regulators etc with and including 3mm thick plastic laminated sheet top cover, including taking down old unserviceable point wiring complete all as specified & directed.
Ceiling rose surface bakelite 2 to 3 terminals 65x50mm fixed as in repair complete all as specified and directed.
Switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet 3 pin 5/6 Amps flush type (ISI Marked) fixed as in repair complete all as specified and directed.
Socket outlet 2 in 1, 6 pin 5 /6and 16 Amps flush type (ISI Marked) fixed as in repair complete all as specified and directed.
Switch piano type 230 volts, single pole one way 16 Amps, 230 volts (ISI Marked) fixed as in repair complete all as specified and directed.
Calling bell AC 230 volts type including necessary rectangular wooden block fixed as in repair complete all as specified and directed.
Bell push switch piano type (ISI Marked) fixed as in repair complete all as specified and directed.
Regulator electronic rotary step type suitable for ceiling fan of sweep 1200/1400mm fixed as in repair complete all as specified and directed.
BLDC (Brush less direct current) ceiling Fan 1200mm sweep, single phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd, and including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number and taking down old unsv fan and deposited to MES store complete all as specified and directed.
Exhaust Fan 250mm sweep, BEE approved, ISI Marked with mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed by using 4 Nos, bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed.
Sub main wiring with 6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit incl taking out existing complete all as specified and directed. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit (running metre).
Sub main wiring with 4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit incl taking existing complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit (running metre).
Sheet metal enclosure factory made TPN 415 volt 4 way double door suitable for fixing MCB as outgoing and incoming MCCB 3 Pole, 63 Amps, repturing capacity 16 KA as main incoming duly painted including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutal 250 Volts with 200 Amps rated bus bar double door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 4 ways and neutal 250 Volts with 200 Amps rated bus bar double door suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces complete all as specified and directed.
MCB Single Pole with neutral 32 Amps, 240 Volts, repturing capacity 10 kA (ISI Marked) fixed as in repair complete all as specified and directed.
MCB Single Pole 5 to 32 Amps, 240 Volts, repturing capacity 10 kA (ISI Marked) fixed as in repair complete all as specified and directed.
MCCB Triple Pole 63 Amps,420 Volts, repturing capacity 10 kA (ISI Marked) fixed as in repair complete all as specified and directed.
Manisha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .