Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹21.8 L+₹3.8 L (21.1%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹22.9 L+₹5.0 L (27.6%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹24.9 L+₹6.9 L (38.6%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹25.6 L+₹7.6 L (42.5%)Rejected-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L5 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Dec 2019, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT10
GE U WATER SUPPLY DELHI CANTT10
MAINTENANCE AND REPAIR OF SEWAGE TREATED PLANTS TREATED WATER DISTRIBUTION PIPELINES AND PERIODICAL SERVICES OF STPS AREA UNDER GE U WATER SUPPLY DELHI CANTT10
2019_MES_297107_1
GE/WS/D-29 OF 2019-20
Open Tender
Civil Works
Works
270 days
GE U WATER SUPPLY DELHI CANTT10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT10
₹60,000
Yes
6 Feb 2020
13 Nov 2019
10 Dec 2019
13 Nov 2019
9 Dec 2019
28 Nov 2019
Amount
Labour only for carrying out day to day(including sunday & Holidays) Treated water supply complaints of all nature i.e. leakage in STP pipe lines, any blockage, no water supply including noting the complaints in complaint register at Arjun Vihar and allied area complete all as specified and as directed.
Labour only for attending day to day Electrical Supply Complaints (including sunday & Holidays) maintenance of existing LT panels including connecting electrical accessories/spares of water supply installations, electric fittings with lights, short circuits in pump house including noting the complaints in complaint register complete all as specified and as directed.. Note for srl No 1 & 2 :- Material required for attending complaints shall be measured & paid separately under respectvie items here-in-after.
Notes for Srl No. 1 & 2 :- The rates quoted by the contractor shall also deemed to be included for the following :- (i) The complaints shall be attended and the defects shall be rectified by a team of experienced Electrician/Plumber as applicable assisted with adequate number of helpers, matriculation passed qualified having minimum 03 years experience . (ii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 50/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from Contractor's dues. (iii) In case , after checking & attending the defect,if it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractor's view, no recovery will be made.
(iv) While attending the complaint of water supply/Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'/BOQ. However no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job quoted rates (Fittings and fixtures shall be measured and paid separetely under respective items of Sch A/BOQ). (vi) All T&P required for attending the complaints shall be provided by the contractor without any extra. (vii) The pipe fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and ladders etc..,as required at site. (viii) The electrician shall always be in possession of all electrician tools, LT megger, Earth tester, multimeter, crimping tool, insulation tape, hand gloves etc. as required at site.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in any type of soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Taking out/down old unserviceable UPVC/HDPE Pipes of any rating laid in trenches including all fittings with spigot & socket ends complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid separetely.
(iii) 25 mm
(vii) 110 mm
(viii) 160 mm
Relaying of UPVC/HDPE Pipes retrieved against Item No. 6 in old or new position laid in trenches of following sizes including all fittings with spigot & socket ends complete all as specified and as directed. Note :- Excavation & earth work for new location shall be measured & paid separetely.
(iii) 25 mm
(vii) 110 mm
(viii) 160 mm
Supplying and fixing UPVC pipes, sizes as under, of pressure rating 10 kgf/cm2, heavy duty with all pipe fittings such as ends, elbows,unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. fixed to walls with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and cutting through walls, floors and their making good or laying in trenches and also cutting, screwing and waste including jointing with jointing material complete all as specified and as directed. Note :- Excavation & earth work for new location shall be measured & paid separetely.
(iii) 25 mm
(vii) 110 mm
(viii) 160 mm
Supply Only UPVC Socket ISI Marked of following sizes complete all as specified and as directed.
(iii) 25 mm
(vii) 110 mm
(viii) 160 mm
Supply Only UPVC Elbow ISI Marked of following sizes complete all as specified and as directed.
(iii) 25 mm
(vii) 110 mm
(viii) 160 mm
Supply Only UPVC Reducing socket ISI Marked of sizes as under complete all as specified and as directed.
(ii) 20x15 mm
(iii) 25x20 mm
(iv) 50x40 mm
Supply Only PP-R Gate valves (brass inserted) ISI Marked of sizes as under complete all as specified and as directed.
(iii) 40 mm
Taking up or down GI steel tubing of following sizes with connections from branches/floors/walls including cleaning for refixing or removal complete all as specified and as directed. Note:- Excavation & earth work shall be measured & paid separetely.
(i) 15 mm GI Tubing
(ii) 20 mm GI Tubing
(iii) 25 mm GI Tubing
Supplying, Laying jointing and Testing of GI steel tubing medium grade of following size in old or new position in trenches with necessary fixing arrangements and including providing new GI fittings complete all as specified and as directed. Note :- (i) Excavation for new location shall be measured & paid separetely.
(i) 15 mm GI Tubing
(ii) 20 mm GI Tubing
(iii) 25 mm GI Tubing
Supplying, Laying, jointing and Testing of GI steel tubing medium grade of following size in old or new position as in walls/ceilings/floors with necessary fixing arrangements and including providing new GI fittings complete all as specified and as directed.
(i) 15 mm GI Tubing
(ii) 20 mm GI Tubing
(iii) 25 mm GI Tubing
Supply and fixing in replacement Gun metal gate valve, with iron wheel head screwed both ends for iron pipe, ISI Marked as per IS-778 of following sizes complete all as specified and as directed.
(i) 15 mm Bore
(ii) 20 mm Bore
(iii) 25 mm Bore
Supplying, fixing, jointing & testing cast Iron Sluice Valve of following sizes, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete with Nuts, Bolts, washers and rubber gaskets of following sizes including taking out of unserviceable sluice valve complete all as specified and as directed.
(i) 80 mm Bore
(ii) 100 mm Bore
(iii) 150 mm Bore
(iv) 200 mm Bore
(v) 250 mm Bore
Supply, fixing, jointing and testing of Cast iron Non Return valve of following sizes, without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
(i) 80 mm Bore
(ii) 100 mm Bore
(iii) 150 mm Bore
Supply and fixing Cast Iron foot valve, sizes as under, flanged ends, swing type opration with rubber sheet, as per IS : 4038 including taking out unserviceable foot valve complete all as specified and as directed .
(i) 50 mm Bore
(ii) 80 mm Bore
(iii) 100 mm Bore
(iv) 150 mm Bore
Supply, installation and testing of water meter, sizes as under, Woltman type class-B, flanged ends, with Nuts, Bolts, washers and rubber gaskets fixing in horizontal/inclind/vertical position, including cutting of pipes complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints with jointing material shall deemed to be included in the quoted unit rates.
(i) 50 mm Bore
(ii) 80 mm Bore
(iii) 100 mm Bore
(iv) 150 mm Bore
M&L for CI Pipe fittings/specials such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore complete all as specified and as directed.
Supply Only lead pig bar complete all as specified and as directed.
Supply Only Spurn Yarn complete all as specified and as directed.
Supply and fixing High density polythene pipes (HDPE) pipes, sizes as under, of pressure rating 10 kgf/cm2, heavy duty fixed complete to walls with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and including taking down old Pipe complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid separetely.
(iii) 80 mm
making connection of PP-R/UPVC/HDPE distribution branch with main branch, for the following sizes by providing and fixing tee including cutting and making fusion joint etc complete all as specified and as directed.
(i) 16 to 40 mm
(ii) 50 to 75 mm
(iii) 80 to 160 mm
Replacement of old HDPE/UPVC Pipe with DI Pipe of 150 mm dia bore, as per IS 8329-2000, class K-7 laid in trenches Including Supplying, Laying, jointing, testing and commmisioning complete all as specified and as directed . Note :- Excavation & earth work shall be measured & paid separetely.
M&L for DI Pipe fittings/specials such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore complete all as specified and as directed.
Material & Labour for Rubber Gasket joint (Tyton Joint) upto 150 mm bore DI/CI pipe including jointing material complete all as specified and as directed.
Supply only following Items complete all as specified and as directed.
(i) switch piano, flush type 5 amp, single pole, one way 240 volt.
(ii) switch piano, flush type 16 amp, single pole, one way 240 volt.
(iii) socket outlet, 6 amps, 2 in 1, 3/5 pin, 5 amp, single pole, 240 volt.
(iv) socket outlet, 2in 1, 3/5 pin 15Amps, single pole, 240 volt.
(v) PVC insulation tape roll of size 15 mm wide, 10 Mtr long
Supply only PVC insulated multistranded copper conductor wire, 1100 volts, of following sizes, complete all as specified and as directed.
(i) 1.5 Sqmm, single core
(ii) 2.5 Sqmm, single core
Supply only PVC insulated sheathed unarmoured copper flexible cable, 1100 volts grade heavy duty, of following sizes, complete all as specified and as directed.
(i) 35 Sqmm, single core
(ii) 50 Sqmm, single core
Supply only of 3 pole power contactor Type MNX 25, 110 Amps, 415 volts, 50 HZ complete all as specified and as directed. Make :- L&T or equivalent in Havells/Siemens as approved by GE.
Supply only of 3 pole power contactor Type MNX 32, 110 Amps, 415 volts, 50 HZ complete all as specified and as directed. Make :- L&T or equivalent in Havells/Siemens as approved by GE.
Supply Only Thermal Overload Relay Type MN relay range 28-42 amp complete all as specified and as directed. Make:- L&T or equivalent in Siemens /BCH as approved by GE
Supply Only Thermal Overload Relay Type MN relay range 20-32 amp complete all as specified and as directed. Make:- L&T or equivalent in Siemens /BCH as approved by GE
Supply Only Thermal Overload Relay Type MN relay range 13-21 amp complete all as specified and as directed. Make:- L&T or equivalent in Siemens /BCH as approved by GE
Supply Only MCB, Single Pole 6 to 32 Amp, 240 Volt complete all as specified and as directed. Make:- L& T or equivalent in Havells/ Siemens
Supply and fixing in replacement 3 pole power contactor ML-6, 110 Amps, 415 volts, 50 HZ complete all as specified and as directed. Make :- L&T or equivalent in Havells/Siemens as approved by GE.
Supply and fixing in replacement 3 pole power contactor ML-4, 70 Amps, 415 volts, 50 HZ complete all as specified and as directed. Make :- L&T or equivalent in Havells/Siemens as approved by GE.
Supply and fixing in replacement 3 pole power contactor ML-3, 40 Amps, 415 volts, 50 HZ complete all as specified and as directed. Make :- L&T or equivalent in Havells/Siemens as approved by GE.
Supply and fixing in replacement 3 pole power contactor ML-2, 32 Amps complete all as specified and as directed. Make :- L&T or equivalent in Havells/Siemens as approved by GE.
Supply only of Timer switch series FM/1 quartz, type-QT (Daily) supply -240 AC, 50/60 Hz complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 200 Amps with breaking capcity 36 KA , 415 volts, complete all as specified and as directed. Make:-L& T or equivalent in Legrand/ Siemens.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 100 Amps with breaking capcity 25 KA , 415 volts, complete all as specified and as directed. Make:-L& T or equivalent in Legrand/ Siemens.
Supply and fixing LED tube light fitting integral type suitable for 1 x 18 watts, 230 volts, connector block etc with all accessories internally prewired and including connecting with twin core flexible copper cable of suitable size including taking down/out fitting as existing at site complete all as specified and directed. Make:Bajaj/Havells/CG/Phillips
M&L for fabrication, welding and fixing of MS frames made out of MS angles Irons/Flat of any size for UG sump for making valve pit chamber and sump cover, stair case steps and all other iron works including painting two coats of synthetic enamel paint over a coat of red oxide primer Complete all as specified and as directed.
Supply only 20 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 20 mm bore complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles
PCC 1:4:8 type D-2 using 40 mm graded mechanically crushed stone aggregates as in foundation, sub base and mass concrete complete all as specified & as directed.
PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in coping, grouting MS frame etc including form work complete all as specified and as directed..
Material and labour for brick work with Sub class B bricks of old size, straight or curved on plan to any radius in full brick thick (23 cm), built in cement mortar 1:4 complete all as specified and as directed.
Rendering 10 mm thick in CM 1:6 on fair faces of brick wall/concrete surfaces and finished fair & even complete all as specified and as directed..
M & L for preparation of old surfaces of wall including washing rubbing down, filling of cracks and stopping of distemper and painted surface and applying Two coats of cement based paint including necessary scaffolding work etc complete all as specified and as directed.
M & L for preparation of old surfaces of wall including washing rubbing down, filling of cracks and stopping of distemper and painted surface and applying One coat of Distemper oil based paint including necessary scaffolding work etc complete all as specified and as directed.
Material and labour for painting to steel and iron surfaces by using spray Gun with one coat red oxide and one coat of synthetic enamel paint as per existing pattern after preparation of old surfaces of any description over 10 cm in width or girth Complete all as specified and as directed By Engg-in-Charge. Make:- Burger/ Asian/ Nerolac of First quality.
M & L for preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with one coat of Aluminium paint upto 6 mtr long and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole no's with paint complete all as specified and as directed.
supply and fixing in replacement of automatic Garden water pop sprinkler lawn irrigation system rotation 40-360 degree complete all as specified and as directed. Make:- Pro sport/ rain drop or equivalent
An amount of Rs 98917.00 shall be deducted from BOQ on account of schedule of credit
Rahul Enterprises
Ridhi engineers and builders
Deven Associates
Vishal Traders
Ashish Sehgal and Co.
Saini Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .