Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 CrAdmitted-Finance | ₹8.9 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical As per Decision of PC-WTD Committee |
| 3 | Rejected-Technical PLOT NO 72 IMT MAIN ROAD SECTOR 68 FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | - | - | Rejected-Technical As per Decision of PC-WTD Committee |
| Sl No | Description | Qty | Unit | Vikran Engineering Limited L1 |
|---|---|---|---|---|
| 1.00MAIN MATERIAL/ ITEMS | ||||
| 2.00Circuit Breakers | ||||
| 3.00220 kV Circuit Breakers | ||||
| 4.00220kV circuit breakers (3 Ph.) Along with support Structure | ||||
| 5.00 | 2500 A, 50 kA | 4 | Nos. | 29,90,000 ₹36.0 L |
| 6.00132 kV Circuit Breakers | ||||
| 7.00132 kV circuit breakers (3 Ph.) Along with support Structure | ||||
| 8.00 | 1250 A, 40 kA | 4 | Nos. | 11,70,000 ₹14.1 L |
| 9.0033 kV Circuit Breakers | ||||
| 10.0033 kV circuit breakers (3 Ph.) Along with support Structure | ||||
Updated dates
Tender Value
₹42.4 Cr
EMD Value
₹84.7 L
Closing Date
6 Jan 2026, 4:00 pmClosed
SE(Contracts-I), RVPN, Jaipur
MM Building, Old Power House Premises, Bani Park,Jaipur-302006
Construction of 220 kV GSS Hemda and Bays works at existing GSS under BN-9018002535 on turnkey basis
2025_RRVPN_511146_1
RVPN/EHV/BN-9018002535
Open Tender
Electrical Works
450 days
All Rajasthan
Please refer Tender documents.
27 documents required · 27 mandatory
₹17,700
As per bid specification
₹84.7 L
10 Apr 2026
6 Nov 2025
6 Jan 2026
6 Nov 2025
6 Jan 2026
6 Nov 2025
Circuit Breakers
220 kV Circuit Breakers
220kV circuit breakers (3 Ph.) Along with support Structure
132 kV Circuit Breakers
132 kV circuit breakers (3 Ph.) Along with support Structure
33 kV Circuit Breakers
33 kV circuit breakers (3 Ph.) Along with support Structure
Instrument Transformers
Capacitor Voltage Transformer
33 kV Potential Transformer
Current Transformer (1-Phase)
1000/1 A, 5C (Live Tank Type only)
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
New Substation
Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA
Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
Other Items:
Surge Arresters
Substation LT Transformer
33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil
Batteries & Battery Charger
Batteries (Sizing shall be as per requirement of technical specification)
Battery Charger System
Lighting System
Outdoor Lighting & other Works
Outdoor Receptacle
Substation Premises Lighting
Lighting poles
Indoor Lighting & Other Works
Electrification
Illumiation
Indoor Lignting Panels
Fire Fighting System
220 kV tower type AT1/AT3
DCP Type
NUMBER #
Carbon di oxide type – 6 Liters.
Foam Type- 9 Liters
Nitrogen Injection Fire Protection System for Power Transformer (50 MVA ) complete in all respects.
Sand type
i) GI Buckets 9 liters capacity
ii) Steel Stands for four buckets
Air Conditioning System
Air Conditioning for the Rooms specified in the specifications
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
Power Cables(XLPE)
1Cx630 sq.mm
3.5Cx300 sq.mm
Power Cable(PVC)
1Cx150 sq.mm
3.5Cx70 sq.mm
3.5Cx35 sq.mm
4Cx16 sq.mm
4C x 6 Sq. mm
2C x 6 Sq. mm
Control Cable (PVC)
4 CX4 Sq. mm
3Cx2.5 sq.mm
5Cx2.5 sq.mm
7Cx2.5 sq.mm
10Cx2.5 sq.mm
14Cx2.5 sq.mm
19Cx2.5 sq.mm
Substation Structures
Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
Isolators
220 kV (3-Phase) (Horizontal DOUBLE BREAK)
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Post insulators for above Isolator
per sq mtr
Post insulators for above Isolator
Post insulators for above Isolator
220/132 kV, 160 MVA Auto Transformer with all accessories (excluding transformer Oil) as per technical specification
Post insulators for above Isolator
132 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator with one E/S
Post insulators for above Isolator
1250A isolator without E/S
Post insulators for above Isolator
33 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator without E/S
Post insulators for above Isolator
800 A isolator without E/S
Post insulators for above Isolator
800A isolator withE/S
Post insulators for above Isolator
Switchyard Erection
Busbar & Interconnections
New Substation/ Switchyard
220 kV Switchyard Works:
Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
4.0 Mtr. Wide Road with shoulders of 1 m on both side of CC road
Twin ACSR Zebra
Single ACSR Zebra
Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:
220 kV DMT-type layout
Line bay
Transformer bay
Bus-Coupler
Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
132 kV Switchyard Works:
Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors,
Twin ACSR Zebra
Single Panther
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
Line bay
Transformer bay
Bus-Coupler
132 kV Main & Aux-type layout
Bus Sectionalizer
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
Bus Post Insulators (BPI)
Earthing & Lightning Protection System
Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
Insulating Oil for 160 MVA 220/132 kV Auto Transformer as per S-I , (1) above
40 mm Dia MS Rod
3.0 Mtr. Wide Road. with shoulders of 0.60 m on both side of CC road
SUB CONTROL ROOM BUILDING (SUB CONTROL ROOM KIOSK)
40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.
50X6 mm GS Flat
Earth Enhancing Compound for treated pits as above and other requirement as per specification
Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
Earth Wire for Shielding Protection of Switchyard
7/3.15 Galvenized Steel Wire
Earthwire tension clamps with D Shackle assembly
PG calmp to suit 7/3.15 mm GS earth wire
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat
Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat
Lug to suit 7/3.15 mm earth wire
Bay Marshalling KIOSK
200 way (Stud Type Connectors)
Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
AC Distribution Boxes (Outdoor Type)
Outdoor AC Distbibution Box (Double Front type)
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
LT Switchgear
Outdoor AC Distbibution Box (Single Front type)
LT AC Main Panel
LT AC Distribution Board
Main Lighting Distribution Board
Emergency Lighting Distribution Board
220V DCDB
48V DCDB
PLCC EQUIPMENTS
220 kV Wave trap (2000A, 0.5 mH, 40 kA)
132 kV wave trap (1250A, 0.5 mH, 40 kA)
SSB single Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
A.F. Protection coupler microprocessor based suitable for Four commands.
220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Microprocessor based 32/16 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility
Main Bus: 33 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays + Bus Coupler]
Telephone Sets (Push Button Type)
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
Foam Type- 45 Liters
50X12 mm GS Flat
FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails
5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
Box Spanners
Aux Bus: 33 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays + Bus Coupler]
TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS
SF6 Leakage Detector
Digital Multimeter
Digital Clamp Meter
PLCC Maintenance/Testing Equipments:
Level generator with a range at 50Hz to 620kHz including facility for synchronization with SLM
8 digit time interval & frequency counter with the frequency range of 10 Hz to 10MHz & timer range of 1 microsec to 1 sec in decade steps.
Dual range 15 MHz oscilloscope with a display screen 8x10 sq.cm and the input impedance of 1 M ohm/25 pF with a deflection coefficient of 5Mv/div to 20 V/div.
4-1/2 digit LCD Multimeter with input impedance of 10Mohm & with a range of 0.1 mV to 1000 V DC, 0.1mV to 600v AC, 0-10 AMP AC,(40hz to 10KHz) & 0-20 Mohm With builtin power –supply.
(A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements]
Print testing Kit for PLCC terminal, protection coupler, EPAX , As per specifications appended at Annexure- V2-P3-S19-2, Volume-II, Part 3, Section-XIX
Oil Sampling Bottle (1 Liter Capacity)
Vaccum Cleaner
Telescopic ladder aluminium 6 meter height
Ring spanner set
Tube spanner set
Pipe wrench 24 inch
Pipe wrench 18 inch
Hydraulic crimping tools up to 630 sq.mm
Threading die set for pipe threading
Welding machine (arc welding) 10kVA
Heavy duty drilling machine
Bench Vice
Insulated cuttingplier 12 inch
Insulated cuttingplier 8 inch
Screw driver 18 inch
Screw driver 12 inch
Hammer 8 lbs
Hammer 2 lbs
Chain pulley block 5 ton
Pipe derrick
Allen Keys
(B) Maintenance Tools& Tackles
Insulation Rubber mat (1mX2mX 12 mm)
(C )Office and Miscellaneous Equipments/ Items
Isulation Rubber Gloves (15 kV Tested)
Furniture for Control Room Building:
SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification
Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet)
Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet).
Library Shelf with Glass Door (min 4 Shelf)
Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane.
Archival Storage 4 Drive Type
Lateral Filing Cabinets
3 Drawer Unit
4 Drawer Unit
Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.
Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.
Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system.
Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage).
Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG.
Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage
Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round.
Key board (wooden) with Glass door
First Aid Box
Shock Treatment Chart [Laminated with Frame]
Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner]
Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr)
RO/ Water Purifier
Refrigirator (380 Lt.)
Danger Plate [Size and Color etc. be got approved from owner]
(D) Drinking Water Arrangement
Coupling Devices for Phase to ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
(One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism.
Rubber gaskets, ‘O’ rings and seals
Fixed Contacts
Moving Contacts
Terminal pads and connectors
Closing Assembly Valve
Trip Assembly Valve
Auxiliary Switch Assembly
Closing Coils
Tripping coils
Support insulator complete for one pole of breaker
Operation Counter
Rubber gaskets, ‘O’ rings and seals
Fixed Contacts
Moving Contacts
Terminal pads and connectors
One pole of circuit breaker without support structure and operating mechanism.
Closing assembly valve
Operation counter
Closing Coils
Tripping coils
Trip assembly valve
Auxiliary switch assembly
Support insulator (set complete for one pole of breaker)
Instrument Transformer
Spare of 245kV Capacitive Voltage Transformer
Instrument Transformer
(i) Complete CVT
Spare of 145kV Capacitive Voltage Transformer
Spare of 245kV Current Transformer
1000/1 A, 5C (Live Tank Type only) (0.2 class)
(i) Complete CT [1 No. each type supplied)
Bay Control Unit (220 kV Side of offered type)
Spare of 145kV Current Transformer
(E) C&R panels (similar items as used in the quoted panels)
Bay Control Unit (132 kV Side of offered type)
Bay Control & Protection Unit (33 kV Side of offered type)
Bay Unit (For 220 kV Busbar Protection of offered type)
Bay Protection Unit (Distance for 220 kV Feeders of offered type)
Bay Protection Unit (Line Distance cum Differential for 220 kV Feeders of offered type)
Bay Protection Unit (Distance for 132 kV Feeders of offered type)
Bay Protection Unit (Differential for 220 kV Transformers of offered type Main-I)
Bay Protection Unit (Differential for 220 kV Transformers of offered type-Main-II)
Breaker failure relay (numerical type)
Bay Protection Unit (Differential for 132 kV Transformers of offered type)
Bay Protection Unit (Back-up Overcurrent & E/F of offered type)
Trip circuit supervision relay
Self reset trip relay
DC supervision relays
Hand reset trip relay
Timer relay
Multifunction Panel Meter
Flag relays
Auxiliary relays
Fiber Optic Cable with Connectors
Ethernet Switch (of offered type)
Nos. (Each Type)
(G) Surge Arrester
2 Nos. Terminal connector of each type as spare
Switches/Push buttons and Meters
220kV class 198 kV rating LA complete as specified.
132kV class 120 kV rating LA complete as specified.
220 V & 48 V Type Battery
Spare battery cell without electrolyte
Terminal connectors with bolts & Nuts
Vent Plugs
Nos. (each type)
220V/ 50V Battery Chargers
Set of Control Cards
Set of relays
Set of contactor
Micro-switches
Filter Capacitors
Thyristor/ Diode
Set of switches
Set of wound resistors
20 pair Jelly Filled and armoured telephone cable with copper conductor of 0.63 mm
set (of each type)
Relays
CTs AND PTs
TPN Switches/MCB
(H) Battery & Battery Charger
L.T. Breaker spares
a) Spring charging motor
b) Aux. Contact sets
c) Busbar Seal off insulators
d) Arc-chutes
e) Moving contacts
f) Arcing contacts (Fixed/Moving)
g) Springs (Closing/Opening)
h) Closing coil
i) Tripping coil
j) Aux. finger contact
k) Limit switches
l) Jaw contacts
Busbar
a) Busbar insulators
Celing Fan
c) Busbar strip 1mm (Aluminium)
meter
Single Pole MCB
Triple pole MCB
Fluorescent tube & Starter
a) Choke
b) Bottom Strips
c) Top covers & reflector (if applicable)
d) Holders
e) Complete fittings
Sodium vapour/Mercury vapour Lamps a) Lamp
b) Ballast
c) Condenser/ Igniter
d) Lamp holder
f) Complete fittings
No. (Each Type)
Incandescent lamp
a) Bulbs
b) Holders
c) Complete fittings
Switches and sockets
No. (Each type)
(L) Fire Protection System
NIFPES System
Fitted Nitrogen Cylinder [48 Lit Water Capacity]
Hose Pipe with Fittings
Heat Sensor Assembly
(K) Clamps & Connectors Set
(J) LIGHTING SYSTEM
Solid core Insulator Stacks (Requirement of one Isolator)
Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered.
Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered
Motor with gear assembly and bevel gear assembly.
Bearings (Requirement of one Isolator)
Current carrying assembly total (Requirement of one Isolator)
Solid core Insulator Stacks (Requirement of one Isolator)
Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered.
Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered
Motor with gear assembly and bevel gear assembly.
Bearings (Requirement of one Isolator)
Current carrying assembly total (Requirement of one Isolator)
Fire Survival Cable [sufficient for 1 system]
Limit Switches for Fire Detector
Fire Detector (for NIFPES System)
Thermostat
Heating Element
Fiber Optic Approach Cable
(M) Isolators
BoQ_Ver3.0
Service Part including ETC
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Auto Transformer:
Power Transformer:
Circuit Breakers
220 kV Circuit Breakers
220kV circuit breakers (3 Ph.) Along with support Structure
132 kV Circuit Breakers
132 kV circuit breakers (3 Ph.) Along with support Structure
33 kV Circuit Breakers
33 kV circuit breakers (3 Ph.) Along with support Structure
Instrument Transformers
Capacitor Voltage Transformer
33 kV Potential Transformer
Current Transformer (1-Phase)
1000/1 A, 5C (Live Tank Type only)
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
New Substation
Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA
Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
Other Items:
Surge Arresters
Substation LT Transformer
33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil
Batteries & Battery Charger
Batteries (Sizing shall be as per requirement of technical specification)
Battery Charger System
Lighting System
Outdoor Lighting & other Works
Outdoor Receptacle
Substation Premises Lighting
Lighting poles
Street Lighting Type-SL-D1 for mounting on Poles
Indoor Lighting & Other Works
Electrification
Illumiation
Indoor Lignting Panels
Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator
Exhaust Fans
Fire Fighting System
Nitrogen Injection Fire Protection System for Auto Transformer (160 MVA ) complete in all respects.
JOINT BOX (48 FIBER) OPGW CABLE
Air Conditioning System
Air Conditioning for the Rooms specified in the specifications
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
Power Cables(XLPE)
1Cx630 sq.mm
3.5Cx300 sq.mm
Power Cable(PVC)
1Cx150 sq.mm
3.5Cx70 sq.mm
3.5Cx35 sq.mm
4Cx16 sq.mm
4C x 6 Sq. mm
2C x 6 Sq. mm
Control Cable (PVC)
4 CX4 Sq. mm
3Cx2.5 sq.mm
5Cx2.5 sq.mm
7Cx2.5 sq.mm
10Cx2.5 sq.mm
14Cx2.5 sq.mm
19Cx2.5 sq.mm
Substation Structures
Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
Isolators
220 kV (3-Phase) (Horizontal DOUBLE BREAK)
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Post insulators for above Isolator
per sq mtr
Post insulators for above Isolator
Post insulators for above Isolator
220/132 kV, 160 MVA Auto Transformer with all accessories (excluding transformer Oil) as per technical specification
Post insulators for above Isolator
132 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator with one E/S
Post insulators for above Isolator
1250A isolator without E/S
Post insulators for above Isolator
33 kV (3-Phase) (Horizontal DOUBLE BREAK)
1250A, isolator without E/S
Post insulators for above Isolator
800 A isolator without E/S
Post insulators for above Isolator
800A isolator withE/S
Post insulators for above Isolator
Switchyard Erection
Busbar & Interconnections
New Substation/ Switchyard
220 kV Switchyard Works:
Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
Single ACSR Zebra
Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:
220 kV DMT-type layout
Line bay
Transformer bay
Bus-Coupler
Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
132 kV Switchyard Works:
Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors,
Twin ACSR Zebra
Single ACSR Zebra
spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Single Panther
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
Line bay
Transformer bay
Bus-Coupler
132 kV Main & Aux-type layout
Bus Sectionalizer
Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
Lighting Fixture Type FL-1
Lighting Fixture Type FL-2
33 kV Switchyard Works:
33 kV Overhead Jack Bus for Transformer Incomer (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
Line bay
Transformer bay
Bus-Coupler
33 kV Main & Aux-type layout
LT Transformer connection with ACSR Panther conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors
132/33 kV, 50MVA Power Transformer with all accessories (excluding transformer Oil) as per technical specification
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
Bus Post Insulators (BPI)
Earthing & Lightning Protection System
Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
Insulating Oil for 160 MVA 220/132 kV Auto Transformer as per S-I , (1) above
40 mm Dia MS Rod
40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.
50X6 mm GS Flat
Earth Enhancing Compound for treated pits as above and other requirement as per specification
Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
Earth Wire for Shielding Protection of Switchyard
7/3.15 Galvenized Steel Wire
Earthwire tension clamps with D Shackle assembly
PG calmp to suit 7/3.15 mm GS earth wire
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat
Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat
Lug to suit 7/3.15 mm earth wire
Bay Marshalling KIOSK
200 way (Stud Type Connectors)
Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
AC Distribution Boxes (Outdoor Type)
Outdoor AC Distbibution Box (Double Front type)
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
LT Switchgear
Outdoor AC Distbibution Box (Single Front type)
LT AC Main Panel
LT AC Distribution Board
Main Lighting Distribution Board
Emergency Lighting Distribution Board
220V DCDB
48V DCDB
PLCC EQUIPMENTS
220 kV Wave trap (2000A, 0.5 mH, 40 kA)
132 kV wave trap (1250A, 0.5 mH, 40 kA)
SSB single Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
A.F. Protection coupler microprocessor based suitable for Four commands.
220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
Microprocessor based 32/16 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility
Main Bus: 33 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays + Bus Coupler]
Telephone Sets (Push Button Type)
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
Insulating Oil for 50MVA 132/33 kV Power Transformer S-II (4) above
Nitrogen Injection Fire Protection System for Power Transformer (31.5 MVA ) complete in all respects.
2000A, 50KA, isolator with two E/S
2000A, 50KA, isolator without E/S
(M) Isolators
CIVIL WORKS
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
2000A, 50KA, isolator without E/S (TANDEM Type)
Bus section isolator
Insulation Tester (5000 Volts, Digital)
Substations with RTU/SCADA Based System
FODP Installation
28mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.
Line Bays on Existing Terminal Substations:
220 kV tower type AT4
220 kV CT, support structures
220 kV CVT support structures
220 kV Tendom Isolator (including associated PIs)
220 kV Isolator
Fiber Optic Approach Cable Intallation
220 kV tower type AT6/AT7/AT8
220 kV PI Structure
132 kV PI Structure
220 kV Circuit Breaker
132 kV tower type BT4
132 kV CT, support structures
132 kV LA support structures
132 kV CVT support structures
132 kV Isolator
33 KV PI Structure
33 kV structure Y type with stub
33 kV structure Z type
33 kV CT/PT structure
33 kV isolator
145 kV SF6 Circuit Breaker
36 kV Vacuum Circuit Breaker
48 Fibre (DWSM)
Lighting Mast
132 kV tower type BT1/BT3
Installation Hardware set for above 48 Fibre, Fibre Optic Approach Cable
132 kV tower type BT6/BT7
CABLE TRENCH
220 kV ,LA support structures
FOUNDATION FOR160 MVA, 220/132 kV TRANSFORMER:-
Civil works for MS Tank including Excavation, Laying of 75 mm PCC, Constructing brick wall jacket around the tank, laying of 200 mm RCC raft, leveling and alignment of MS Tank, backfilling with excavated sand, Top leveling by laying of PCC, as per site requirement and Technical specifications (complete job).As per specification for 160 MVA Transformer
Type C Cable trench
CABLE TRENCH CROSSING
Construction of RCC sump having capacity 10000 Liters with provision of automatic dewatering mud pump with disposal arrangement upto outside RVPN premises as directed by Engineeer In-charge with provision of a stand by pump.
per job
Road crossing for 'C' type cable trenches
Per R.M.
Isolator handle mechanism
FOUNDATION FOR 40/50 MVA, 132/33 kV TRANSFORMER:-
Supply and stacking earth material obtained from borrow pits with all leads and lifts, transporting to site, spreading, grading to required slope & compacting by vibratory roller 8-10 Ton to meet requirement of table 300-2 including cost of compensation for earth taken from private land with all lead as per MORTH specification clause no. 305.
220 KV Circuit Breaker
ANTI WEED TREATMENT AND BASE LAYER OF INTERLOCKING TILES
JELLY SPREADING (Gravelling)
Supply & Fixing Barricades to confine Jelly (gravel), which include Supply and fixing cement concrete solid blocks of size 60x(20+25)/2x30 cms (l, b, h) jointed with CM 1:4, made from precast M-20 concrete and laid over 100 mm thick base of PCC 1:4:8 including necessary curing etc. complete. The top of concrete block shall be 100 mm above gravel top with provision of suitable openings for drainag
e of rain water. The exposed surface of barricades shall be applied with two coat of water proof cement paint.
Supply of labour, material equipments and construction of station Transformer’s foundation with RR stone masonry in CM 1:6 of size 1.5mx 1.5m with top of foundation at 1.5m above other foundation and depth of excavation minimum 600 mm below NGL with 2 nos MS Channels 150X 75 mm embeded in 200 mm thick CC M 20 on top of masonry, outer plaster 20 mm thick CM 1:4 and applying white weather proof painting coat on exposed surfaces (top and sides) of foundationand other items not mentioned herein but required for the completion of work as p
ling with excavated sand, Top leveling by laying of PCC, as per site requirement and Technical specifications (complete job). As per specification for 40/50 MVA Transformer
Type A Cable trench
ROAD WORK
WATER SUPPLY :-Supply and installation of water supply system with construction of GLR, submersible cables, pump room with pump and one stand- by pump for the sub-station, required electrifcation cables from control room and panels, providing and laying GI pipe line from GLR to control room, yard, guard room,store, for plantation etc including making connection , landscaping,construction and development of park as per the drawing & plantation as per specification & approved drawings and directions of engineer incharge.
per Job
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas including filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including with all lead and lift. All kinds of soil.
BoQ_Ver3.0
Type A Cable trench
Single Tension hardware for single Zebra (Bolted type)
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MAIN MATERIAL/ ITEMS
220 kV Circuit Breakers
220kV circuit breakers (3 Ph.) Along with support Structure
Instrument Transformers
Capacitor Voltage Transformer
Current Transformer (1-Phase)
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
Limit switches and auxiliary switches ---Each Set containing one no. of each type and rating as offered
Other Items:
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
Add; Any other item co complete Civil works
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
Control Cable (PVC)
3Cx2.5 sq.mm
Relays, power contactors, MCB’s switch fuses, push buttons and resistors
Total FOR DEST. Amount with All Taxes ( In Rs.) in Rs. P
Isolators
220 kV (3-Phase) (Horizontal DOUBLE BREAK)
Post insulators for above Isolator
Switchyard Erection
Busbar & Interconnections
New Substation/ Switchyard
Surge Arresters
220 kV DMT-type layout
Line bay
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
Earthing & Lightning Protection System
40 mm Dia MS Rod
245kV Relay Panel for line Line relay Panel: • Main-I type relay • Main-II Type Relay • Over voltage Protection relay • Auxiliary relay, Tripping Relay, Supervision relays, timers (one of each type used in the panel) • Under-voltage relay for isolator/earth switch • LBB Relay
245kV Control Panel for line
75X12 mm GS Flat
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
Earth Wire for Shielding Protection of Switchyard
PG calmp to suit 7/3.15 mm GS earth wire
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat
Lug to suit 7/3.15 mm earth wire
Substation Structures
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
48V DCDB
A.F. Protection coupler microprocessor based suitable for Four commands.
BoQ_Ver3.0
Type A Cable trench
Single Suspension hardware for Zebra
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MAIN MATERIAL/ ITEMS
220 kV Circuit Breakers
220kV circuit breakers (3 Ph.) Along with support Structure
Instrument Transformers
Capacitor Voltage Transformer
Current Transformer (1-Phase)
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
Limit switches and auxiliary switches ---Each Set containing one no. of each type and rating as offered
Other Items:
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
Add; Any other item co complete Civil works
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
Control Cable (PVC)
3Cx2.5 sq.mm
Relays, power contactors, MCB’s switch fuses, push buttons and resistors
Total FOR DEST. Amount with All Taxes ( In Rs.) in Rs. P
Isolators
220 kV (3-Phase) (Horizontal DOUBLE BREAK)
Post insulators for above Isolator
Switchyard Erection
Busbar & Interconnections
New Substation/ Switchyard
Surge Arresters
220 kV DMT-type layout
Line bay
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
Earthing & Lightning Protection System
40 mm Dia MS Rod
245kV Relay Panel for line Line relay Panel: • Main-I type relay • Main-II Type Relay • Over voltage Protection relay • Auxiliary relay, Tripping Relay, Supervision relays, timers (one of each type used in the panel) • Under-voltage relay for isolator/earth switch • LBB Relay
245kV Control Panel for line
75X12 mm GS Flat
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
Earth Wire for Shielding Protection of Switchyard
PG calmp to suit 7/3.15 mm GS earth wire
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat
Lug to suit 7/3.15 mm earth wire
Substation Structures
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
48V DCDB
A.F. Protection coupler microprocessor based suitable for Four commands.
CIVIL WORKS
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Necessary peripherial units, cards ,hardware, software wiring for adding new 245 kV bays (as per scope of specification) in the existing 220 kV Bus Bar Protection Scheme.
Bus section isolator
220 kV CT, support structures
145 kV SF6 Circuit Breaker
CABLE TRENCH
220 kV ,LA support structures
4Cx2.5 sq.mm
Civil works for MS Tank including Excavation, Laying of 75 mm PCC, Constructing brick wall jacket around the tank, laying of 200 mm RCC raft, leveling and alignment of MS Tank, backfilling with excavated sand, Top leveling by laying of PCC, as per site requirement and Technical specifications (complete job).As per specification for 160 MVA Transformer
CABLE TRENCH CROSSING
18Cx2.5 sq.mm
Construction of RCC sump having capacity 10000 Liters with provision of automatic dewatering mud pump with disposal arrangement upto outside RVPN premises as directed by Engineeer In-charge with provision of a stand by pump.
per job
2000A, 50KA, isolator with Double E/S
Per R.M.
Isolator handle mechanism
FOUNDATION FOR 40/50 MVA, 132/33 kV TRANSFORMER:-
Supply and stacking earth material obtained from borrow pits with all leads and lifts, transporting to site, spreading, grading to required slope & compacting by vibratory roller 8-10 Ton to meet requirement of table 300-2 including cost of compensation for earth taken from private land with all lead as per MORTH specification clause no. 305.
40mm Dia, 3.2M Long MS Rod Earth Electrode in untreated pit with test link
ANTI WEED TREATMENT AND BASE LAYER OF INTERLOCKING TILES
JELLY SPREADING (Gravelling)
Supply & Fixing Barricades to confine Jelly (gravel), which include Supply and fixing cement concrete solid blocks of size 60x(20+25)/2x30 cms (l, b, h) jointed with CM 1:4, made from precast M-20 concrete and laid over 100 mm thick base of PCC 1:4:8 including necessary curing etc. complete. The top of concrete block shall be 100 mm above gravel top with provision of suitable openings for drainag
e of rain water. The exposed surface of barricades shall be applied with two coat of water proof cement paint.
40mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.
WATER SUPPLY :-Supply and installation of water supply system with construction of GLR, submersible cables, pump room with pump and one stand- by pump for the sub-station, required electrifcation cables from control room and panels, providing and laying GI pipe line from GLR to control room, yard, guard room,store, for plantation etc including making connection , landscaping,construction and development of park as per the drawing & plantation as per specification & approved drawings and directions of engineer incharge.
per Job
Add: Any other item bidder may require to complete the Civil works as per specification requirements
BoQ_Ver3.0
40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
Clamps and Connectors i.e. PG Clamps, T-Clamps, PI Clamps, Bus Bar Spacers etc. and for ACSR Zebra conductor
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Type A Cable trench
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Circuit Breaker
Voltage Transformer
Lightning Arresters
48V DCDB
CONTROL & RELAY PANELS
Phase to Ground coupling device
Disc Insulators
Disc Insulator 120 KN
Clamps and Connectors i.e. PG Clamps, T-Clamps, PI Clamps, Bus Bar Spacers etc. and for ACSR Panther conductor
Note:- All the dropped jumpers shall be of Y-type.
145 kV SF6 Circuit Breaker
145 kV Solid Core Post Insulators (including for Isolators & PIS)
145 kV, 1250 Amp. 40 kA rupturing capacity Circuit Breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories as per specification and terminal Connectors
Copper Control Cables NON-FRLS (Unarmoured)
18 core x 2.5 sq. mm
145 kV 1250 Amp. Triple pole, Gang operated, Horizontal Double break type, motor operated, Isolator metallic without earth blade complete with all accessories as per specification including terminal Connectors
145 kV single phase 4400 pF CVT including terminal Connectors
3 core x 2.5 sq mm
LT Aluminum Power Cable NON-FRLS (Unarmoured)
Crimping type cable lugs (Tinned copper) of size of cable as required.
BoQ_Ver3.0
40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MAIN MATERIAL/ ITEMS
of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare. Any fractions will mean the next higher integer number.
Type A Cable trench
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Circuit Breaker
Voltage Transformer
Lightning Arresters
48V DCDB
CONTROL & RELAY PANELS
Phase to Ground coupling device
Disc Insulators
Disc Insulator 120 KN
Clamps and Connectors i.e. PG Clamps, T-Clamps, PI Clamps, Bus Bar Spacers etc. and for ACSR Panther conductor
Note:- All the dropped jumpers shall be of Y-type.
145 kV SF6 Circuit Breaker
145 kV Solid Core Post Insulators (including for Isolators & PIS)
145 kV, 1250 Amp. 40 kA rupturing capacity Circuit Breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories as per specification and terminal Connectors
Copper Control Cables NON-FRLS (Unarmoured)
18 core x 2.5 sq. mm
145 kV 1250 Amp. Triple pole, Gang operated, Horizontal Double break type, motor operated, Isolator metallic without earth blade complete with all accessories as per specification including terminal Connectors
145 kV single phase 4400 pF CVT including terminal Connectors
3 core x 2.5 sq mm
LT Aluminum Power Cable NON-FRLS (Unarmoured)
Crimping type cable lugs (Tinned copper) of size of cable as required.
CIVIL WORKS
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
220 kV Line Bay Works
Bus section isolator
CABLE TRENCH
220 kV LA support structures
CABLE TRENCH CROSSING
Note:-The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification.
220 kV Isolator
Supply and stacking earth material obtained from borrow pits with all leads and lifts, transporting to site, spreading, grading to required slope & compacting by vibratory roller 8-10 Ton to meet requirement of table 300-2 including cost of compensation for earth taken from private land with all lead as per MORTH specification clause no. 305.
ANTI WEED TREATMENT AND BASE LAYER OF INTERLOCKING TILES
JELLY SPREADING (Gravelling)
BoQ_Ver3.0
145 kV 1250 Amp. Triple pole, Gang operated, Horizontal Double break type, motor operated, Isolator metallic fitted with single earth blade complete with accessories as per specification including terminal Connectors
145 kV 1250 Amp. Triple pole, Gang operated, Horizontal Double break type, motor operated, Isolator metallic fitted TENDEM complete with accessories as per specification including terminal Connectors
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Type A Cable trench
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Circuit Breaker
Voltage Transformer
Lightning Arresters
48V DCDB
Phase to Ground coupling device
40 W 1-CH carrier set W/O Protection Coupler
Co-Axial Cable 75 Ohm
Disc Insulators
Disc Insulator 120 KN
Note:- All the dropped jumpers shall be of Y-type.
145 kV SF6 Circuit Breaker
145 kV Solid Core Post Insulators (including for Isolators & PIS)
18 core x 2.5 sq. mm
145 kV single phase 4400 pF CVT including terminal Connectors
3 core x 2.5 sq mm
LT Aluminum Power Cable NON-FRLS (Unarmoured)
Crimping type cable lugs (Tinned copper) of size of cable as required.
BoQ_Ver3.0
145 kV 1250 Amp. Triple pole, Gang operated, Horizontal Double break type, motor operated, Isolator metallic fitted with single earth blade complete with accessories as per specification including terminal Connectors
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MAIN MATERIAL/ ITEMS
of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare. Any fractions will mean the next higher integer number.
Type A Cable trench
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Circuit Breaker
Voltage Transformer
Lightning Arresters
48V DCDB
Phase to Ground coupling device
40 W 1-CH carrier set W/O Protection Coupler
Co-Axial Cable 75 Ohm
Disc Insulators
Disc Insulator 120 KN
Note:- All the dropped jumpers shall be of Y-type.
145 kV SF6 Circuit Breaker
145 kV Solid Core Post Insulators (including for Isolators & PIS)
18 core x 2.5 sq. mm
145 kV single phase 4400 pF CVT including terminal Connectors
3 core x 2.5 sq mm
LT Aluminum Power Cable NON-FRLS (Unarmoured)
Crimping type cable lugs (Tinned copper) of size of cable as required.
CIVIL WORKS
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Clamps and Hardware i.e. PG Clamps, Strain assembly, etc. for 7/3.15 mm G.S. Earth wire
Bus section isolator
CABLE TRENCH
4 core x 2.5 sq. mm
CABLE TRENCH CROSSING
7/3.15mm GS earth wire
ACSR PANTHER Conductor
Supply and stacking earth material obtained from borrow pits with all leads and lifts, transporting to site, spreading, grading to required slope & compacting by vibratory roller 8-10 Ton to meet requirement of table 300-2 including cost of compensation for earth taken from private land with all lead as per MORTH specification clause no. 305.
ANTI WEED TREATMENT AND BASE LAYER OF INTERLOCKING TILES
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Type A Cable trench
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Circuit Breaker
Voltage Transformer
Lightning Arresters
48V DCDB
CONTROL & RELAY PANELS
Phase to Ground coupling device
Disc Insulators
Disc Insulator 120 KN
Note:- All the dropped jumpers shall be of Y-type.
145 kV SF6 Circuit Breaker
145 kV Solid Core Post Insulators (including for Isolators & PIS)
145 kV, 1250 Amp. 40 kA rupturing capacity Circuit Breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories as per specification and terminal Connectors
Copper Control Cables NON-FRLS (Unarmoured)
18 core x 2.5 sq. mm
145 kV 1250 Amp. Triple pole, Gang operated, Horizontal Double break type, motor operated, Isolator metallic without earth blade complete with all accessories as per specification including terminal Connectors
145 kV single phase 4400 pF CVT including terminal Connectors
3 core x 2.5 sq mm
Crimping type cable lugs (Tinned copper) of size of cable as required.
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
MAIN MATERIAL/ ITEMS
of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare. Any fractions will mean the next higher integer number.
Type A Cable trench
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001
Circuit Breaker
Voltage Transformer
Lightning Arresters
48V DCDB
CONTROL & RELAY PANELS
Phase to Ground coupling device
Disc Insulators
Disc Insulator 120 KN
Note:- All the dropped jumpers shall be of Y-type.
145 kV SF6 Circuit Breaker
145 kV Solid Core Post Insulators (including for Isolators & PIS)
145 kV, 1250 Amp. 40 kA rupturing capacity Circuit Breaker complete with mounting structures, foundation bolts, nuts and first filling of SF-6 gas plus 20% spare gas including accessories as per specification and terminal Connectors
Copper Control Cables NON-FRLS (Unarmoured)
18 core x 2.5 sq. mm
Single Tension hardware for single Panther (Bolted type)
145 kV single phase 4400 pF CVT including terminal Connectors
3 core x 2.5 sq mm
Crimping type cable lugs (Tinned copper) of size of cable as required.
CIVIL WORKS
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. complete for 300 mm dia internal dia pipe including Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design and Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to required depth including taking out the excavated materials, refilling the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with all lead and lifts in all types of soil, rocks etc complete in all respect.
Clamps and Hardware i.e. PG Clamps, Strain assembly, etc. for 7/3.15 mm G.S. Earth wire
Bus section isolator
CABLE TRENCH
4 core x 2.5 sq. mm
CABLE TRENCH CROSSING
7/3.15mm GS earth wire
ACSR PANTHER Conductor
Supply and stacking earth material obtained from borrow pits with all leads and lifts, transporting to site, spreading, grading to required slope & compacting by vibratory roller 8-10 Ton to meet requirement of table 300-2 including cost of compensation for earth taken from private land with all lead as per MORTH specification clause no. 305.
ANTI WEED TREATMENT AND BASE LAYER OF INTERLOCKING TILES
JELLY SPREADING (Gravelling)
stage.html
html • 0.03 MB
techsummary_910665.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.74 MB
Technical_specification_BN-9018002535.pdf
Tender Documents • 13.86 MB
BOQ_910665.xls
BOQ • 2.38 MB
Commercial_Vol-I_Hemda_eproc_approved.pdf
Tender Documents • 7.78 MB
Project_Section_Hemda.pdf
Tender Documents • 0.65 MB
combined_DRG_Hemda.pdf
Other Document • 10.20 MB
Download all tender documents and submit your bid