| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.7 LAccepted-AOC VILL KRISHASAIL P O KHAMRA DIST MURSHIDABAD PIN 742213 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742213 | L1 | Accepted-AOC LOWEST SUCCESSFUL BIDDER | |
| 2 | L2₹56.7 L+₹1.0 L (1.85%)Rejected-Finance PATPUR BANKURA | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹62.1 L+₹6.4 L (11.6%)Rejected-Finance AT G 2 BIDHAN NAGAR PO MEDINIPUR PS KOTWALI PASCHIM MEDINIPUR 721101 | MEDINIPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | L4₹63.7 L+₹8.0 L (14.4%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L4 | Rejected-Finance 4th Lowest Bidder | |
| 5 | L5₹64.2 L+₹8.6 L (15.4%)Rejected-Finance | L5 | Rejected-Finance 5th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
5 Feb 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of Patient Party waiting shade at BSMCH , Gobindanagar campus --- Electrical Installation with alled works
2021_WBPWD_316976_1
WBPWD/SE/SWEC/NIQ35/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.6 L
Office of SE / SWEC, PWD, Midnapore
26 Apr 2023
21 Jan 2021
8 Feb 2021
21 Jan 2021
5 Feb 2021
28 Jan 2021
27 Jan 2021
120 days
Amount
Part-A( Internal Electrification Work)
Supplying and fixing double door 8 way (upto 160A) Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. compraising as follows:- a) Incoming:-415 V, 125A Four Pole MCCB of Breaking capacity 35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting with necessary connection ---- 1 Nos b) Outgoing:- 415 V, 63 A TP MCB of Breaking capacity 10kA & C characteristics on din rail --- 8 Nos [Make:-Siemens (8GB31573RC)/ Schneider/ Legrand] [Allocation : i) Ground Floor - 3, ii) First Floor - 1, iii) Second Floor - 1 iv) Third Floor - 1 v) Fourth Floor - 1]
Supplying and fixing double door 8 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. compraising as follows:- a) Incoming:- Supplying and fixing 415V 63A FP MCB Isolator on din rail of existing DBs and necessary connection - 1 No. b) Outgoing:- Supplying and fixing 240V, 6A-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-24 Nos. [Make:-Siemens (8GB32202RC08)/ Schneider/ Legrand] [Allocation : i) Ground Floor - 6, ii) First Floor - 3, iii) Second Floor - 3 iv) Third Floor - 3 v) Fourth Floor - 3]
Supplying and fixing 250V, 6-10A per way, (2+12) SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment compraising as follows:- a) Incoming:- Supplying and fixing 240V 40A DP MCB Isolator on din rail of existing DBs and necessary connection - 1 No. b) Outgoing:- Supplying and fixing 240V, 6A-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-12 Nos. [Make:-Siemens (8GB32102RC14)/ Schneider/ Legrand] [Allocation : i) Ground Floor - 12, ii) First Floor -10, iii) Second Floor - 10 iv) Third Floor -10 v) Fourth Floor - 10]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment [Make:-Siemens / Schneider/ Legrand] [Allocation : i) Ground Floor - 12, ii) First Floor -5, iii) Second Floor - 5 iv) Third Floor -5 v) Fourth Floor - 5]
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single corestranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/Polycab /RR Kabel / Gloster) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar ncl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] (Average Run 10 Mtr.) [Allocation : i) Ground Floor - 215, ii) First Floor -200, iii) Second Floor -200 iv) Third Floor -200, v) Fourth Floor -200]
Supplying and fixing 19mm dia 3mm thick polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/Polycab /RR Kabel / Gloster) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (Average Run 10 Mtr.)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire(Finolex / Havells/Polycab /RR Kabel / Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI / Mescab /Gloster/approved by EIC) as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish (on Board) [Allocation : i) Ground Floor - 50, ii) First Floor -42, iii) Second Floor -42 iv) Third Floor -42, v) Fourth Floor -42]
Supply & Fixing 240 V, 2 x 6A, plug socket with separate 2 x 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F suitable sizes MS (16SWG) switch board and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Allocation : i) Ground Floor - 40, ii) First Floor -45, iii) Second Floor -45 iv) Third Floor -45, v) Fourth Floor -45]
Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Allocation : i) Ground Floor - 15, ii) First Floor -2, iii) Second Floor -2 iv) Third Floor -2, v) Fourth Floor -2]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer Board ) [Allocation : i) Ground Floor - 3, ii) First Floor -4, iii) Second Floor -4 iv) Third Floor -4, v) Fourth Floor -4]
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 20 0x 65mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Allocation : i) Ground Floor - 3, ii) First Floor -3, iii) Second Floor -3 iv) Third Floor -3, v) Fourth Floor -3]
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire(Finolex / Havells/Polycab /RR Kabel / Gloster) of the following sizes after Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. (19 mm dia 3 mm thick polythene pipe without earth continuity wire)
2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug)
2 x 4 sqmm + 1 x 2.5sqmm (for Security Light )
2 x 6 sqmm + 1 x 4 sqmm ( from TPN MCB DB to SPN MCB DB s )
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Finolex / Havells/Polycab /RR Kabel / Gloster) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2 x 1.5 sqmm + 1 x 1.5sqmm
2 x 2.5 sqmm + 1 x 1.5sqmm
2 x 6 sqmm + 1 x 4 sqmm
Supply & Delivery of following sizes 1.1 KV grade Al. armoured XLPE insulated LT Cables (Havells/ Glostar /Polycab/ RR Kabel) as per direction of EIC
2 nos x 4 core 240 sqmm ( from Sub Station Panel to Feeder Piller )
4 core 185 sqmm ( from Sub Station Panel/ Feeder Piller to Building Panel )
4 core 70 sqmm ( from Panel to VTPN )
4 core 35sqmm ( from VTPN to MCBPBDB )
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of two cables above 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying of following sizes Al. armoured PVC/XLPE cable surface on wall / on wall by clamp / concealed as reqd. with with 2 x 10 SWG GI wire as per direction of EIC
upto 3.5/4 core 35 sqmm to 50 sq mm with 2 x 10 SWG GI wire
above 3½ core 50 sqmm and upto 3½ core 90 with 2 x 10 SWG GI wire
S & F special design MS pati clamp having size 100 x 350 & 3 nos x 50 x 75 mm made by 30 x 3mm MS pati, whose one end fixed on ceiling by suitable size 2 Nos. fastner for holding the 4 core 35 / 95 / 185 / 240 / 2x240 Sq.mm cable.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables incl. Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 core 35 sqmm
4 core 70 sqmm
4 core 185sqmm
4 core 240 sqmm
Supply and Fixing of single/double LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm flexible copper wire of 1.10 mt. length. incl. 2nos mounting kit.
a) Make- Havells, cat no- REGALBATTENT8UPTO1X22WSSBSWH incl. 1 nos. LED tube cat no-PHOTONULTRAE2.01213T8SSTL20WLED865SPC/ Bajaj / Crompton / Philips. [Allocation : i) Ground Floor - 46, ii) First Floor -90, iii) Second Floor -90 iv) Third Floor -90, v) Fourth Floor -90]
b) Make- Havells, cat no- REGALBATTENT8UPTO2X22WSSBSWH incl. 2 nos. LED tube cat no-PHOTONULTRAE2.01213T8SSTL20WLED865SPC/ Bajaj/ Philips. [Allocation : i) Ground Floor - 65, ii) First Floor -16, iii) Second Floor -16 iv) Third Floor -16, v) Fourth Floor -16]
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC [Allocation : i) Ground Floor - 25, ii) First Floor -25, iii) Second Floor -25 iv) Third Floor -25, v) Fourth Floor -25]
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8 watt CFL / 100 watts GLS lamp complete set.
Supply & Fixing of 74 W LED outdoor street light fitting ( Philips make cat No. BRP 409 LED 074 CW HE MR FG SI PSU GR ) complete with all accessories to be fixed / Projected from the wall of the building incl. making holes to the building .S & F 40 mm dia / suitable size GI pipe 1.5 m average length (ISI-Medium)Arm Bracket with GI socket at one end & thread at other end with suitable bend to house fitting and making necy. connections with S& F necy. length of Copper coductor and mending goods to wall incl. painting as per direction of E.I.C.
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC
Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (for controlling outdoor street light fitting fittings)
Inter connection between Loop Box to fittings by 1.1 KV 3 x 2.5 sqmm single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) through 20mm size PVC pipe incl. necy. fittings as required as per direction of EIC
Supplying and fixing Timer panel M S Box with hing type front open door and threathed locking arrangement in one side made of 18 SWG CRCA MS Sheet of size 500x300x200 mm. fixed in wallon flat iron frame as per direction EIC.The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer similar to Microrex QT31 of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand /L & T ) – 1 no B) One no. ML-3 conctactor, with 2 NO or 1 NO + 1 NC Aux. Contact (Make - GEC / Legrand /L & T) – 1 no C) 4 pole 32 Amps MCB (Make - GEC / Legrand /L & T) 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V , Diode type neon Indicator lamp ( (Make - GEC / Legrand /L & T) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling outdoor street light fitting fittings) (Make - GEC / Legrand /L & T/ PWD appvd )
Supply only 250 V 50 HZ 18" (450 mm) high flo oscillating type metal body Wall Bracket fan operated by pull cord switch with inbuilt regulator (Make -Orient, model- Tornado Wall-II or equivalent make of Crompton) [Allocation : i) Ground Floor - 6, ii) First Floor - 2, iii) Second Floor - 2 iv) Third Floor - 2 v) Fourth Floor - 2]
S&F 250V. 50 Hz. 9'' Sweep 1370 r.p.m. Heavy Duty AC Exhaust Fan (Make- EPC(Heavy duty)after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust insl. Supply & Fixing Al. louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [Allocation : i) Ground Floor - 4, ]
S&F 250V. 50 Hz.12'' Sweep 1420 r.p.m. Heavy Duty AC Exhaust Fan (Make- EPC(Heavy duty)after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust insl. Supply & Fixing Al. louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [Allocation : i) Ground Floor - 9, ii) First Floor - 7, iii) Second Floor - 7 iv) Third Floor - 7 v) Fourth Floor - 7]
Supply only of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork incl S & F of P - 2 type capacitor as per IS specification & proper Manufacturer certificate of the capacitor (supplied at the time of delivered the fans ) etc. with out regulator, (Make- Usha (Striker plus CF Br/Wh) / Crompton Greaves (HS Plus 5 star) Orient ( New Breeze ) and as per direction of EIC [Allocation : i) Ground Floor - 50, ii) First Floor - 50, iii) Second Floor - 50 iv) Third Floor - 50 v) Fourth Floor - 50]
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
Supplying & Fixing of Box type fan clamp of 150 mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. [Allocation : i) Ground Floor - 50, ii) First Floor - 50, iii) Second Floor - 50 iv) Third Floor - 50 v) Fourth Floor - 50]
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S. [Allocation : i) Ground Floor - 50, ii) First Floor - 50, iii) Second Floor - 50 iv) Third Floor - 50 v) Fourth Floor - 50]
The additional Safety arragement of celling fans by stranded GI / MS strain wire of suitable gauge with special type socket/thimble / nut bolts which is througly crimped with the strain wire and the wire passing through down rod , also the other end connected with armature spindle by its existing jum nut hole with same specical arrangement as per direction of EIC.
The additional stranded GI / MS strain wire of suitable gauge for safety arrangement with the existing socket/thimble / nut bolts which is througly crimped with the strain wire and the wire passing through down rod , also the other end connected with armature spindle by its existing jum nut hole with same specical arrangement as per direction of EIC.
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S
Engraving the deptt. No. for ceiling/exhaust fan upto 10 letters incl. hifen, stroke or stop as to GS
Painting upto 10 letters of the engraved No. with approved black paint/red paint as required as to GS
Extra for additional one letter incl. hifen,stroke or stop as to GS
Extra painting for additional one letter of the engraved No. with hifen,stroke etc. with black paint/red paint as required as to GS
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required [100mm dia]
Supply, installation, testing & commissioning of CPRI approved cubical type panel board with separate compartmentalized floor mounted, indoor type dust and vermin proof powder coated panel board, suitable for 415V 3phase, 4wire,50Hz, A.C supply of suitable size made out of 14 SWG (2mm.) thick CRCA/M.S. sheet wih angle (50X50X6 mm) , flat ( 50 X 6 mm) structure with individually hinged capsule door for all compartment with lock ,providing ventilation arrangement & free standing from floor mounting . The control panel should have suitable cable entry from bottom of back through detachable gland plate (100mm.x40mm.x4mm.) thick M.S. channel to access sufficient no of incoming & outgoing cable Incl. suitable size G.I. net guard with key & locking arrengement with interconnection with adequate size cu. wire, copper bar, cu link, cable connector etc. along with necy. nuts, bolts, clamps, grouting bolts incl. providing and fixing the following accessories etc. complete as required. (SFUs Make : L&T or equivalent make of ABB/ Schneider/ Siemens) Incoming:- switch disconnector fuse ( panel mounting cubical type) conform to IS 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415V 400 Amp with 3 nos 400 Amp DIN type HBC fuse link,----1 No. Busbar :- S & F 415 V, 800 A current carrying capacity electrolytic grade tinned copper BBC having bus bar dimension of (4 x 40 mm x 5mm) will be fixed on FRP Chair & the entire bars are insulated with PVC heat sinkable sleeves with suitable size & colour as per direction of E.I.C.
Outgoing Switch Fuse Unit: a) S&F of Switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in pen execution three pole & Neutral AC 23A, 50HZ, 415 Volt 160Amp with 3 nos 160 Amp DIN type HBC fuse link , --3 Nos.. b) S&F of Switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in pen execution three pole & Neutral AC 23A, 50HZ, 415 Volt 125 Amp with 3 nos 125 Amp DIN type HBC fuse link , --7 Nos. c) S&F of Switch disconnector fuse (panel mounting cubical type) conform to IS: 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 63 Amp with 3 nos 63 Amp DIN type HBC fuse link, ---2 Nos.
Cable Alley :- Cable Alley in both side of outgoing connection including S & F suitable no. of brass studtype connector on insulated chair having current carrying capacity as per outgoing switch rating. Interconnection should be made with suitable size of cable as mentioned below with proper socketing,tapes in both ends. Interconnection :- a) 4X40mmX5mm size copper bars from busbsr of L.T. panel to 400A SFU b) 4X35mmX4mm size copper bars from busbsr of L.T. panel to 160A SFU c) 4X20mmX3mm size copper bars from busbsr of L.T. panel to 125A SFU d) 16 Sqmm Single Core PVC insulated FR Copper Flixible cable for 63A SFU e) Metering Circuit with 1.5 sqmm single core stranded FRLS PVC copper wire only Ct connection will be made by 2.5 sq. mm. cu wire. all the connection must be done with proper socketing & taping (Empire & PVC Tapes ( R Y B N ).
Submission of details SLD ( both hard & soft copy ) by CAD of the above job with indicating all the items of Power Distribution system with position of Panel, VTPN's, PBDBs, LBDBs , Power Plugs , Lights , Fans , Switch Boards etc. incl. Submission of all testing reports regarding the EI work to complete the installation as per direction of EIC
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long),13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (For Morrum Soil ISI-Medium GI pipe as toGS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Fixing only cabin fan on wall/ceiling byS & F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [Allocation : i) Ground Floor - 6, ii) First Floor - 2, iii) Second Floor - 2 iv) Third Floor - 2 v) Fourth Floor - 2]
Fixing only of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork,rubber bush ete. incl.S& F connecting wire for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required by 2x1.5sqmm flexible wire as per GS. [Allocation : i) Ground Floor - 50, ii) First Floor - 50, iii) Second Floor - 50 iv) Third Floor - 50 v) Fourth Floor - 50]
Part-B ( LIGHTNING CONDUCTOR)
Supply & Fixing Lightning conductor Air-terminals made of 15 mm dia1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:
Length upto 0.5 Mtr
Length above 0.5 Mtr
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long),13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (For Morrum Soil ISI-Medium GI pipe as toGS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
RS SYSTEMS AND PROJECTS
M/S JOGMAYA ENTERPRISE
Prava Enterprise
NAVA NIRMAN UDYOG
PRADIP KUMAR DHABAL
Electromech Engineers Co-Operative Society Ltd.
technical_601206.pdf
PDF • 0.22 MB
techsummary_601206.pdf
PDF • 0.23 MB
finance_601206.pdf
PDF • 0.22 MB
BOQ Comparative Chart
xlsx • 0.03 MB
finsummary_601206.pdf
PDF • 0.23 MB
AOC.pdf
PDF • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .