Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹120.2 CrAccepted-AOC A 177 OKHLA INDUSTRIAL AREA PHASE I NEW DELHI 110020 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110020 | ₹120.2 Cr Quoted ₹252.2 Cr | L1 | Accepted-AOC Work Order Issued |
Tender Value
₹120.2 Cr
EMD Value
₹2.4 Cr
Closing Date
6 Oct 2022, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Lachit Moidam Memorial and Cultural Complex Lahdoigarh, Jorhat, Assam
2022_PWBNH_26878_1
CE/TB-VI/59/2022/14 Dated Guwahati 1st Sept 2022
Open Tender
Civil Works - Building
910 days
Jorhat
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,000
₹2.4 Cr
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
16 Feb 2023
5 Sept 2022
6 Oct 2022
6 Sept 2022
6 Oct 2022
14 Sept 2022
13 Sept 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 1.5 to 3 m depth)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 3 to 4.5 m depth)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 4.5 to 6 m depth)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil (From 6 to 7.5 m depth)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. cum 368.65 2.26 Extra for every additional lift of 1.5
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size drived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size drived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg /cum
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Stairs,(excluding landings) except spiral-staircaces.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walis- Under 20cms wide
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Weather shade,Chajjas, corbels etc. including edges
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of deshutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roots, laning, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg/cum
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement : 2 coarse sand), including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and filling in position bitumen mix filler of proportion 80 kg. of hot bitumen, 1 kg. of cement and 0.25 cubic metre of coarse sand for expansion joints.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 115 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level. Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand)
Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Lalitpur Grey / Kandla Grey/White sand stone
Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : Circular or polygonal pillars or Half Craved Panels
Extra for stone work (veneer work) curved on plan with a mean radius not exceeding 6 m.
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Lalitpur Grey / Kandla Grey/White sand stone
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of Slab over 0.50sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50 x 20 mm
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 35 mm thick Second class teak wood shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Second class teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick.
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete..
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 140 mm
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing, fabricating, welding and fixing in position 1mm thick M.S. sheet door shutter with all round frame for door shutter of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, M.S. angels 40x40x6 mm for diagonal braces all necessary fittings complete. Rate shall include providing, fixing and welding 2 Nos. MS Aldrop 300x16 mm size and 1 Nos. 300x12 mm tower bolt and providing, fabricating, welding and fixing in position MS frame/Chowkat made 45x45x6mm MS angle on top and both vertical sides including fixing the MS chowkat with 6 nos. MS hold Fast of 45x45x6mm, 300mm long fish tail duly grouted in cement cocrete block of 1:2:4 of 150x100mm x wall thickness and providing and applying 2 coats of 1st quality synthetic enamel paint of approved manufacturer over a priming coat of approved steel primer,etc complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.
Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum),including factory painted after bending and perforation,and backed with a black Glass fiber acoustical fleece.
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks)
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long Dry Wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
PProviding and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25mm height, made of G I sheet having galvanizing of 100gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Flat surfaces
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Curved surfaces
Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling.
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
12 mm cement plaster of mix : 1:6 (1 cement : 6 Course sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 Course sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
Distempering with oil bound washable distemper of approved make and shade to give an even shade : New work (two or more coats) over a coat of approved make water thinnable priming coat with cement primer
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, ptimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.Cement concrete prepared with batch mixing machine
Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge).
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used 450 mm dia piles
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used 600 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 50 tonne and upto 100 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 50 tonne and upto 100 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 10 mm depth and 10 mm width
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in- Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. For horizontal surface Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : For vertical surface- Using rough Kota stone
Providing and placing in position suitable PVC water stops conforming to IS:12200 between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc complete. Serrated with central bulb (225mm wide,8-11mm thick)
Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding).
Supplying and laying of Uni-Axial Woven Polyster Geogrid conforming to MORTH 3100 and IRC113, as soil reinforcement/basal reinforcement including accessories like tie-strips, nuts & bolts and loops/lugs for joining reinforcing elements with the facia pannels, overlaps and other protective elements for synthetic geo-grids and all other activities required for reinforced soil walls, slopes etc complete as per design requirements, manufacturer specifications and as per direction of engineer-in- charge. Uni Axial Woven polyster geogrid of minimum tensile strength 80 KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
Providing and laying 125 micron thick Membrane of impermeable plastic sheeting
Providing and fixing approved brand and manufacture H type 1200mm Pull Handle with 32mm dia fixed with screws etc. complete in all respects as per manufacturers' specifications, architecture approved design & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock with key cylinder fixed fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture Stainless Steel 304 grade Godrej CYLINDRICAL LOCKS - CLASSIC LOCK Model no 5808. Complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and laying 18 mm thick leather finish black granite stone flooring in required design and patterns, in linear as well as curvilinear portions in building, footpath all complete as per the architectural drawings with over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Extra for pre finished nosing to treads of steps of Granite stone.
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre .
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. Flooring
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. Wooden flooring Skirting same as above
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. Floor strip on edges 20% of Wooden flooring
Providing and fixing machine cut, mirror/ eggshell 18mm thick leather finish steel grey granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.
Providing and fixing Granite stone gang saw cut (polished and machine cut) of thickness 18mm for wall lining, backing filled with a grout of average 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar with an admixture of pigment to match the granite shade etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.
Providing and fixing 30mm thick Lalitpur grey sand stone gang saw cut Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :
Supply and fixing of Glass Fiber Reinforced Concrete (G.F.R.C) Elements in approved size, pattern, design, thickness ( 25-30 mm internal , 35-40 mm External) and color of M/S Terra Firma make . The GRC element should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘Saint Gobain OCV , Neg Japan or equivalent, Super Plasticizers manufactured by ‘BASF’ , Nerolac Perma or equivalent, Polymers manufactured by ‘BASF’, Nerolac Perma or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing of GFRC Element work with Dry Fixing method using fasteners, and necessary hardware etc in Building Facade complete as per directed by Engineer-in-Charge In Glass Reinforced Concrete (G.R.C.) Element (COLUMN) as per design in approved size, pattern, thickness and shade.
Providing and fixing Single Glazing 6mm thick toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ≤ 0.45, U-Value ≤ (W/sq.m-K) 5.7W /M2K, Visible light transmittance ≥ 0.30)
Providing and installation of roofing tiles on pitched roof with following process in the sequence as detailed below: 1. MS TRUSS (separately paid) 2. Supply and Fixing of Cement Fibre board of 12mm thickens (Everest or equivalent) over MS truss with self drilling screws. 3. Supply and laying of 5 layers self sealing membrane for water tightness and thermal insulation 4. supply and fixing of MS perlins (battens) size 2" x 2" for fixing of Roofing tiles and Ridge tiles. 5. Supply and fixing of ITALIAN TOGNANA Clay Roof tiles (natural terracotta colour) profile "ROYAL COPPO or equivalent approved make size 42X25.6cm and weight 3.3Kg/per tile with coverage 13.8 tiles per SqM. 6. Supply and fixing of Ridge tiles on the Ridges/ hips, Supply and fixing accessories like metal valley sheets, with dry fixing method using Ridge vent membrane, ridge tree, ridge clips, tile clips etc. all complete as per Architectural drawing and as directed by the Engineer-in-Charge.
Providing and fixing Exterior Grade HPL Sheet (6 mm Thick) Color of HPL Boards-options : Plain/Woods/Abstracts of approved Make complete in all respects as per design / elevation as approved by AUTHORITY
Providing and fixing U Baffle Aluminium panel ceiling (M/s Hunter Douglas or Equivalent) consisting of Wood finish panel size 30 mm width X 100mm deep using 0.6mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be clipped to a baked enamelled Aluminium carrier of 30 mm wide x 47 mm high x 0.5 mm thick, Black Colour coated, one leg of the carriers with cut outs to hold the panels in a module of 150 mm. Panel carrier shall be suspended by means of threaded rod at a distance of 1.8 mtr c/c. Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, Exposed side with a full primer and finish coat on a Continuous Paint Line. Ceiling area above U Baffle to be painted in black colour before fixing this system (Cost of black paint shall be paid separately).
Providing Making & Finishing Second class teak wood Railing as per approved architecture design complete in all respect including T&P and as per directed & approved by Enfgineer-In-Charge
30 mm thick Tandur stone slab flooring (Antique Finish) over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
30 mm thick Tandur stone slab flooring (Short Blasted and Diamond Brushed) over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge.
Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge.
Supply and fixing of Mineral fibre Ceiling tiles duly paintable with 15mm thickness,in Size 595x595 mm square edge tiles with at least 0.5 NRC, 95% RH, Class A Fire retardent material along with 15mm gypsum board as per final design finalized complete with putti and paint job as required. Make - Armstrong/RK ceiling/Gyptech
Supply and fixing of Acoustical wall Paneling using MDF customize grooves & laminated Boards 12mm thick of size - 128 x 2440 mm as per acoustic design / Architects approval with final coat of wood varnish. Back frame made out of GI channel - Grid of 600x600 mm Stud 50mm ,Floor,parameter section and screws as required,wall linining to be filled with rockwool of thick 50 mm (48 kg/m3) density with black cloth supporting to be done from ground level up to 8 ft height. Make - Action tesa/Prolad /Anakon
Supply and fixing of Wood wool boards of 15 mm with fire rating of Class B-1, NRC of at least 0.65,RH > 70% breathable factory painted (color as per client’s choice) with profile lining made out of wood. Back frame made out of GI channel - Grid of 600x600 mm Stud 50mm ,Floor,parameter section and screws as required,wall linining to be filled with rockwool of thick 50 mm (48 kg/m3) density with wire chicken mesh/Black cloth supporting to be done at in all the four sides of the wall GI channel from 8ft level to ceiling height. Make - Durosound /prolad /Anakon
Supply and fixing of fabric wrapped acoustic wall panel Acoustical Fabric strech paneling with 12mm x 28mm thk Acoustical Fabric UPVC grippers with 50mm x 35mm x .5mm stud & floor channel & section G.I. frame work of 600 x 600m Center to Center(one side) & will be fixed to the wall with necessary fastners & screws with Chicken wire mesh. The frame work center to be filled with woodwool board . (design as per clients choice) with back frame of pine wood frame. Various sizes to be fabricated as per final design. The fabric should be flame retardent in nature with polyester wadding inside of at least 25 mm thick. Make - Durosound /prolad /Anakon
Supply and fixing of Wooden Procenium made out of 10mm ply fixed on MS pipe of 40x40 or 50x50mm structure erected on the stage front, duly grouted/fixed on surface complete with black paint as required. Make - Bhutani/Century Ply/Green Ply
Supply and fixing of Wooden Acoustical Doors 60mm Thick for STC 37 with necessary hardwares of the following specifications and as per the final drawings. The Door frame shall he of l35mmx70mm section Hard Wood, including making necessary grooves for fixing of hollow bulb type EPDM Gasket on the rebates. The core of the door shutter shall he made out of hardwood, ply and MDF, filled with resin bonded rockwool of 64kg/m3 density with 3mm thick sound dampening layer. Having Fire Retardant calcium cilicate boards and fire seals to comply 120 minuted fire rating as per BS-476 Part 20 & 22, along with fire rated 12 mm thick ply board for MICA Laminate finish. Shutter shall have wooden lipping Edge. Thickness of the shutter 60mm. The door assembly shall be fixed to the door frame with heavy duty stainless steel hardwares. Shutters shall be fixed with SS Hinges. The job shall include Provision of Hinges, Mortice Lock one side key and one side knob, Door Stopper & Drop Down Seal. All hardware as per approved by Architect and provide by client. Make - Customized Door
Supply and fixing of 6 mm Carpet Flooring (color and design as per client’s choice) duly fixed on finished floor using SR998 resin adhesive. Make - Kanak/Mohawk/Innovations
Supply and fixing 22" Push back high chairs to be grouted on the floor, fabric wrapped, color as per client's choice. Self Tip Up Cushions Centre distance (Arm-rest to Arm rest) shall be 22” as required. Housing for Cushion & Backrest FEP - Fiber Molded - FRP Cushion bottom and back rear panels of heavy duty Materials Sheet Metal: HRC sheet metal as per IS:1079 1994, All metal exposed & visible parts shall be painted Polyurethane: Density : 50 +/-5kg /M3 as per JIS K 6401. Make - Royal/Innovations /star furniture.
Providing construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine complete as per direction of engineer-in-charge.
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm
Fine dressing of the ground
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 60 cm dia, and 60 cm deep.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 45 cm dia, and 45 cm deep.
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge.
Providing and Displaying Euphorbia milli hybrid variety with multi branch, full bloom, with fresh and healthy well developed having 30 to 45 cm ht. in 35 cm Cement Pots as per direction of the officer-in-charge.
Providing and stacking of Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
Providing and stacking of Chlorophytum-variegated, full of leafy suckers in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ipomea (Golden leaves),with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Juniperus prostrata with 5 to 6 latral branches and green foliage in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ophiopogon jaburan (variegated ), full of variegated leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Portulacaria afra (Jade ) with 5 to 6 branches in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Schefflera green, having 3 to 4 branch, ht. 30 to 45 cm well developed with fresh & healthy in 20 cm size of Earthen Pot/ Plastic Pot as per direction of the officer-in-charge
Providing and stacking of Setcreasea purpurea full of variegated leaves in 15 cm size of Earthen Pot/Plastic Pot as per direction of the officer-in-charge
Providing and stacking of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge.
Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.
Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and displaying of Areca Palm having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Dracaena Marginata having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Livistona palm having ht. 60 cm to 75 cm, well developed with 8 to 10 leaves, fresh & healthy foliage in 30 cm size of Earthen pot/Plastic pot. as per direction of the officer-in-charge.
Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.
Providing and Displaying Cycus revoluta in 35 cm challi, specimen plant, having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge.
Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Phoenix roebelenii palm well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Washingtonia filifera palm well developed 90 to 105 cm ht. having 5 to 6 straight fresh and healthy leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and stacking of Fishtail palm of ht. 150-180 cm bottom girth 15- 20 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.
Providing and stacking of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Alstonia scholaris of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bassia latifolia (Mahua) of height 90-105 cm. in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Chukrassia tabularis of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus elastica Decora (Rubber ) of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus infectoria (Pilkhan) of height 150-165 cm. in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Grevillea robusta (Silver Oak) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Heterophragma adenophyllum (Marore fali) of height 150-165 cm. in Big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Kigelia pinnata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Lagerstroemia flosreginae of height 150-165 cm.in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Magnolia grandiflora of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Melia azedarach of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Millingtonia hortensis of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Peltophorum species of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Spathodea campanulata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.
Providing and displaying of Raphis palm having ht. 75 cm to 90 cm with 12 to 15 equal suckers, well developed, full of fresh & healthy leaves from bottom to top in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multi branched in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Euphorbia caracasana (bronze colour leaves) of height 60-75 cm. with 2-3 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Jatropha multifida (red colour) of height 60-75 cm. multibranched in p.bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Largerstroemia indica of height 90-105 cm. multibranched in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge.
Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Plumbego capensis well developed with fresh and healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge.
Providing and stacking of Putranjiva roxburghii of ht. 45-60 cm in bag of size 15 cm as per direction of the officer-in-charge.
Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 75-90 cm. with 5-6 branches in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and Stacking of Ficus panda plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge
Providing and stacking of Roystonea regia of bottom girth 15- 20 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cyrtostachys renda (Lipstic Palm) of bottom girth 15- 20 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Agave desmettiana of bottom girth 15- 20 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Agathis robusta of height 210 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Erythrina crista-galli of height 240 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Saraca asoca of height 210 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Terminalia mantaly of height 150 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Artocarpus altilis of height 150 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Gmelina arborea of height 150 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Toona cilliata of height 180 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Morus alba of height 150 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Terminalia chebula of height 180 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Artocarpus heterophyllus of height 150 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mesua ferrea of height 180 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Dipterocarpus tubinatus of height 120 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Dipterocarpus macrocarpus of height 120 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus long island of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Ixora chinensis of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing, Fabrication, Erection and Installation of Bronze statue 125 feet height over 25 feet high RCC pedestal ( Total Height of Statue and Pedestail 150 feet ) Statue of Lachit Borphukan consisting of Bronze skin of average 8 mm thick cladded on steel armature of stainless structure steel for the statue space frame members supporting the exterior cladding as per technical specifiaction and vetted design and model, with commissioning with all incidental expenses such as wind tunnel test (consisting of wind climate analysis, proximity model and structure wind load study through RWDI or equivalent agency) complete in all respect with complete mechanism of maintenance and monitoring etc. The Bronze Statue also Includes. a) Artist Sculpture Design & Modelling charges for 125 feet statue og Lachit Borphukan b) SS Steel structure to support 125 feet High statue . c) Installation charges of Bronze parts at site , d) Transportation charges of any kind. , e) Providing & Fixing Double Scaffolding system , f) Hire Charges of Tower Crane , g) Cost of Wind Tunnel test , h) Preparation of 1:1 scale statue in thermocol, i) Bronze casting of statue panels. , f) Welding of 1:1 scale bronze statue in Foundry., g) Final finishing of bronze statue at site., h) Final painting with PU paint (metallic bronze shade). Note : Contractor need to verify and analyse the quantities as per design intent before quoting the price . Statue work to be treated as desingn build with wind tunnel test and all incidental expenses if any required to complete the statue complete to be included in the quoted price. Nothing extra will be paid other than quoted one job price. Payment will be regulated as per percentage weightage as indicated below. During execution of work, running bill payment will be regulated on prorata basis. Cost of pedestal will be paid separatly as per tendered item. Persentage weightage for cost of Bronze Statue . 1- Bronze skin (125 Feet Bronze Statue of Lachit Borphukan) of average 8 mm thickness - 37% , 2- Stainless Steel Armature Structure- 50% , 3-Cost of Artist, Sclupture Design & Modelling Charges of 125 Feet Bronze Statue of Lachit Borphukan - 13% Micro Pyment schedule to be submitted within weightage after award of work by successful bidder with documentary prof
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc, exceeding 80mm dia but not exceeding 300mm dia
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 70 m Head
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 180 LPM at 70 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads. 900 LPM at 35 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads. 450 LPM at 35 m Head
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves,chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing & reinforcement with1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of Grade Fe-500D or More.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. -150 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :- 150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : -100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : -150 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : - 80 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : - 100 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : - 150 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. - 150 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Providing and fixing trap of self cleansing design with screwed down or hinged with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. 100 mm diameter pipe
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for nstantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 32 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 50 mm dia. nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 50 mm dia. nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 25 mm nominal dia Pipes
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 32 mm nominal dia Pipes
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 40 mm nominal dia Pipes
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50 mm nominal dia Pipes
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 65 mm nominal dia Pipes
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 80 mm nominal dia Pipes
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 65 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 80 mm nominal dia Pipes
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.52m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.52m internal dia (at bottom) beyond 2.30m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. HD-20 circular shape 560 mm internal diameter.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. - 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. - 200 mm diameter
Constructing bricks masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes including bed concrete as per standard design. - 250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes including bed concrete as per standard design. - 300 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : -250 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : -300 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : -450 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : -500 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : -600 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. - 100mm dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. - 150mm dia
Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil - 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil - 400 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 700mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 1000mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. - 1200mm
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 70 m Head
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. - 65 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. - 80 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. - 100 mm dia
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing and fixing of white vitreous china wall hung European type water closet of approved shape and size with inside glazed P trap, with concealed flushing cistern dual flush capacity of 2.1 / 4.2 LPF including soft close anti-bacterial seat & cover infused with nano silver ions (AG+) for 99.9% bacteria protection along with hinges & rubber buffers, CP brass screw, washer with all associated accessories with side gap filled with silicon sealant wherever required complete including cutting and making good the walls, floors, slab wherever required complete. Wall Hung WC with seat cover Make Kohler Model No K-26998IN-0 + Concealed Flushing Cistern Make Kohler Model No K-26352IN-M-NA + Face Plate for Cistern Make Kohler Model No K-75891IN-M-CP + W.C Pan Connector Make Kohler Model No K-1046327-S + W.C Chair Bracket Make Kohler Model No K-1225108-0 or Equivalent.
Providing and fixing of white vitreous china wall hung European type water closet of approved shape and size with inside glazed P trap, with concealed flushing cistern dual flush capacity of 2.1 / 4.2 LPF including soft close anti-bacterial seat & cover infused with nano silver ions (AG+) for 99.9% bacteria protection along with hinges & rubber buffers, CP brass screw, washer with all associated accessories with side gap filled with silicon sealant wherever required complete including cutting and making good the walls, floors, slab wherever required complete. Wall Hung WC with seat cover Make Kohler Model No K-72987IN-SR-0 + Concealed Flushing Cistern Make Kohler Model No K-26351IN-M-NA + Face Plate for Cistern Make Kohler Model No K-75891IN-M-CP + W.C Pan Connector Make Kohler Model No K-1046327-S + W.C Chair Bracket Make Kohler Model No K-1225108-0 or Equivalent.
Providing and fixing white vitreous china wash basin of approved shape and size with special fabricated brackets duly painted white, faucets as required, 32 mm C.P. brass waste.32 mm C.P. brass bottle trap & pipe to wall with rubber adopter for waste connection and C.P. brass wall flange complete in all respects including cutting and making good the walls where required. Counter Top Wash basin Make Kohler Model No K-2660IN-1-0, 32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP, or Equivalent.
Providing and fixing white vitreous china wash basin of approved shape and size with special fabricated brackets duly painted white, faucets as required, 32 mm C.P. brass waste.32 mm C.P. brass bottle trap & pipe to wall with rubber adopter for waste connection and C.P. brass wall flange complete in all respects including cutting and making good the walls where required. Under Counter Wash basin Make Kohler Model No K-2215IN-2-0 , 32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP, or Equivalent.
Providing and fixing white vitreous china wash basin of approved shape and size with special fabricated brackets duly painted white, faucets as required, 32 mm C.P. brass waste.32 mm C.P. brass bottle trap & pipe to wall with rubber adopter for waste connection and C.P. brass wall flange complete in all respects including cutting and making good the walls where required. Flat back Wash basin Make Kohler Model No K-30520IN-0, 32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP, or Equivalent.
Providing and fixing white vitreous china urinal of Make Kohler Model-K-16321IN-SS-0,with integrated sensor including fixing to wall with suitable brackets, ,32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP or Equivalent. complete including cutting and making good the walls and floors where required.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink single bowl with single drain board 1220 x 510mm, bowl depth 200mm with mat finish Make Jayna Model-SBSD 05 (RR) , Sink Mixer Make- Kohler Model-K-37313IN-4-CP or Equivalent.
Providing and fixing Stainless Steel Waste pipe for sink including waste fittings complete. 40 mm dia.
Providing and fixing brass toilet paper holder Kohler Model. No. K-25346IN-BN or Equivalent. including cutting and making good the walls wherever required.
Providing and fixing C.P. brass 15 mm nominal bore two way bib cock Kohler Model.K-16094IN-4-CP or Equivalent
Providing and fixing C.P. brass 15 mm nominal bore one way bib cock Kohler Model.K-20073IN-4-CP or Equivalent.
Providing and fixing C.P. brass 15mm nominal bore angle valve Kohler Model. K-80154IN-4-CP or Equivalent.
Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws Kohler model. No. K-25073IN-CP or Equivalent.
Providing and fixing health faucet with 1 m long flexible tube and wall hook including all fittings Kohler model No.K-12925IN-CP or Equivalent. .
Providing and fixing 15mm C.P. copper connecting pipe 450mm long with C.P. brass nuts, washers complete in all respects. Make Jaquar Model. No.ALD-801B or approved equivalent.
Providing and fixing fully automatic Hand dryer Kohler Model-K-5486T-2-0P or equivalent. including all fittings complete in all respect.
Providing and fixing liquid soap dispenser including all fittings complete.Make Euronics Model-ES18 or equivalent.
Providing and fixing Aerosol Perfume Dispenser including all fittings complete.Make Euronics Model-EA03 or equivalent.
Providing and fixing Paper Dispenser including all fittings complete.Make Euronics Model-EP08S (AC) or equivalent.
Providing and fixing Swing Grab Bar Jaquar Model No. WAC-SAP-BG0800CS including cutting and making good the walls wherever required.
Providing and fixing Hand Rail Jaquar Model No. WAC-WHT-BR0750, Satin including cutting and making good the walls wherever required.
Providing and fixing 40 litre/ hr. cooling and 80 Litres storage capacity,fully stainless steel electric storage type water cooler (Blue Star model No. SDLX 480 or equvalant) with inlet hose connection inbuilt float valve. 2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy compressor and wire up to socket, 3 pin plug etc complete in all respect.
Supplying, installation, testing and commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 50 litres / hour designed at a minimum Flux at inlet complete as required.
Providing and fixing of C.P. brass 600 mm size towel rail Kohlar Model. No. K-5630IN-CP or equivalent fixed with C.P. brass screws complete in all respects.
Providing and fixing of C.P. brass Soap Dish Make Kohlar Model. K-5634IN-CP or equivalent) fixed with C.P. brass screws complete in all respects.
Providing and Fixing of C.P. Brass Shower set comprising of : One No. CP brass shower mixer. Make Kohler Model No. K-98754IN-4-CP or approved equivalent. Including cutting and making good the walls wherever required. Shower set as described above.
Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). Capacity 25 Litres Venus Model 25 GV
Providing and fixing 15mm C.P brass Single Lever Basin Mixer for Wash Basin with aerator complete with 1.5m braided hose pipe mounting rubber gasket including cutting and making good the walls wherever required. Make Kohler Model No K-27479IN-4ND-CP or Equivalent.
Providing and fixing 15mm C.P brass Soft press auto closing Pillar Faucet for Wash Basin with aerator complete including cutting and making good the walls wherever required. Make Kohler Model No K-20747IN-8-CP or Equivalent.
Providing & fixing Centrifugally Cast (Spun) Iron Hubless Pipes & Fittings as per IS-15905, (plain or door of LH/ RH/ Rear as required as per site) e.g. bends, junction, offsets, end caps, including Stainless Steel (SS-304) Coupling with Electrometric Gasket (EPDM) as per ISO-6594 / DIN-19543 / ASTM / IS-15905 Standards, suitable joints with nuts and bolts, including cutting chase or holes in walls and floors and making good the same wherever required. 100 mm dia.
Providing & fixing Centrifugally Cast (Spun) Iron Hubless Pipes & Fittings as per IS-15905, (plain or door of LH/ RH/ Rear as required as per site) e.g. bends, junction, offsets, end caps, including Stainless Steel (SS-304) Coupling with Electrometric Gasket (EPDM) as per ISO-6594 / DIN-19543 / ASTM / IS-15905 Standards, suitable joints with nuts and bolts, including cutting chase or holes in walls and floors and making good the same wherever required. 150 mm dia.
Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. 150 mm dia.
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 20 mm Pipe
Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical soil, waste, vent and rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. For 100 mm Pipe
Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint. 100 mm dia
Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint. 150 mm dia
Providing and fixing in position 100x50 mm dia GI reducing elbow including fix to floor with cement mortar.
Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar.
Providing and fixing 100 mm dia GI inlet fitting/ Extension Piece with 2 or 3 inlets of 32 to 50 mmdia, fixed to CI trap with lead joint and set in cement concrete as per drawing complete.
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. - 20 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. - 25 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. - 32 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. - 40 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. - 50 mm nominal bore
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 25 mm Pipe
Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia.
Providing and fixing threaded end brass digital water meter complete in all respect. - 32 mm dia.
Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves,necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. - 32 mm dia.
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098 including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. -160 mm OD
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098 including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. -200 mm OD
Providing and fixing 80 mm dia. GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
Supply, Lowering, installation & testing of KSB make submersible pumping set with 7.5 HP motor 4 stage pump suitable for 20/26/30/38/40/45/50 m3 hr. at 42/38/36/32/29/25/20 mtr. Head respectively. With Three Phase. (Model: 273/4)
Providing & fixing cable 6 sq.mm. From submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. 80mm dia
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 16 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required. -80mm dia
Providing, installing, testing and commissining of variable speed (VSPS) hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, dedicated variable frequency drive for each pump, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 60 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects, including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required. The entire Hydropneumatic system shall be factory fitted. Hyd. System for Domestic Water Supply at Pump Room Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 3.0 LPS Head 40 M. HP 3.0 HP Approxi.
Providing, installing, testing and commissining of variable speed (VSPS) hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, dedicated variable frequency drive for each pump, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 60 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects, including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required. The entire Hydropneumatic system shall be factory fitted. Hyd. System for Flushing Water Supply at Pump Room Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 3.0 LPS Head 40 M. HP 3.0 HP Approxi.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. (Pumps shall be installed in a set of two pumps One working and One standby) Pump Room Drainage Pumps (Pumps to be suitable to handle solids upto 12 mm size) Capacity - 4.0 LPS (Each) Head - 15 M H.P. - 1.5 HP Approx.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. \ Sewage Sump Pumps (Pumps to be suitable to handle solids upto 40 mm size) Capacity - 4.0 LPS (Each) Head - 15 M H.P. - 2.0 HP Approx.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. Irrigation Pump in Pond (Pumps to be suitable to handle solids upto 12 mm size) Capacity - 5.0 LPS (Each) Head - 40 M H.P. - 5.0 HP Approx.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required. For Water Supply Pump: To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required. For Sump Pumps: To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. - 50 mm dia
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. - 65 mm dia
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. - 80 mm dia
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. - 100 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. - 50 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. - 65 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. - 100 mm dia
Providing & fixing dual plate CI water type check valve tested to a pressure of 16 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required. -65 mm dia
Providing & fixing dual plate CI water type check valve tested to a pressure of 16 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required. -80 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm. -50 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm. -65 mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. - Power cable Copper 3 core 6 sq.mm
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. - Power cable Copper 3 core 4 sq.mm
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. - Control cable copper 2 core 1.5 sq.mm
Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete including CC foundation of suitable size. Dual Media Filter For Domestic Water Supply Capacity- 7200 LPH Filtration rate- 14000 LPH/Sqm. Filter dia approx. - 800 MM Working pressure: 3.0 Kg/sq cm. Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 200 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-12 lph, complete in all respects. Chlorination of Domestic Water
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. -100 mm dia.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. -80 mm dia.
Providing and fixing MS partly glazed double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 1.20 m x 2.1m )
Providing and fixing of Weather proof hose cabinets fabricated from 14 g M.S. Sheet with full glass door and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 m x 0.25 m).
Supply, Installation, Testing & Commissioning of double flanged vertical air vessel fabricated shell from 10 mm thick & dished ends 12 mm thick M.S.plate, suitable for working pressure of 18 kg/cm2 and test pressure of 27 kg/cm2, 450 mm dia and 2.00 m high for fire pumps complete with four nos dual setting pressure switches to operate jockey and main pumps at drop of pressure as given in the specifications.
Providing & fixing 150 mm diameter MS Class ‘C’ for diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the diesel engine. The pipe shall be provided insulation with fibre glass wool and wraped with 24g. aluminium sheet complete with all respect.
Providing and fixing of gun metal fire Brigade Suction Hose coupling (Draw-out Connection) with nut for female coupling as per IS:902- 1974 complete with 100 mm dia. G.I. Suction pipe and 100 mm dia. 1No. C.I. Foot valve flanged (to be connected to static water tank).
Providing and fixing heavy duty Fire'men Axe.
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. - 80 mm dia
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. - 100 mm dia
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. - 150 mm dia
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Power cable 3 core 16 sq mm aluminium conductor armoured cable.
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Power cable 3.5 core 120 sq mm aluminium conductor armoured cable
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas) Capacity 4.5 Kg.
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas) Capacity 6.0 Kg.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25mm dia
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B(Type-IV & Above)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, 2 Way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300sq. mm
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
REPEATER PANEL Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
PHOTOTHERMAL (MULTITECH) DETECTOR Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Below False Ceiling
PHOTOTHERMAL (MULTITECH) DETECTOR Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Above Fasle Ceilling
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 A
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. - 450 mm width X 50 mm depth X 2.0 mm thickness
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 50 sq. mm (35 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 95 sq. mm (45 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 120 sq. mm (45 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 150 sq. mm (50 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 3½ X 300 sq. mm (70 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 4 X 10 sq. mm (25 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. - 4 X 16 sq. mm (28mm)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, laying, installation, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required. - 2 Core x 2.5 Sq.mm Cable
Supplying, laying, installation, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required. - 4 Core x 2.5 Sq.mm Cable
Supplying, laying, installation, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required. - 10 Core x 2.5 Sq.mm Cable
Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required. - 2 Core x 2.5 Sq.mm Cable
Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required. - 4 Core x 2.5 Sq.mm Cable
Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required. - 10 Core x 2.5 Sq.mm Cable
Supplying and fixing following rating, 'C' series, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 amps
Supplying and fixing following rating, 'C' series, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 amps
Supplying and fixing following rating, 'C' series, Double pole, 240 volts, RCBO (30mA, 10KA) in the existing MCB DB complete with connections, testing and commissioning etc. as required. (SPN DB Incomer)- 40 amps
Supply of 20W COB LED downlight recess mounting luminaire with high performance LEDs with suitable wattage as per design, suitable for mounting with Armstrong/Grid ceiling, Aluminium powder coated white after phosphochromate treatment. LED module is mounted on FR4 with system lumen efficacy of >100lm/W to enhance the lumen output to ensure better uniformity.Powered by an SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. Lumen Output of 2000 lumens.CRI >80, Color temperature 5700K, THD <10% and PF >0.95,IP20,Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV.
Deep Recessed adjustable (UGR<19) LED Downlighter 15W . Fixture to be made of Albumin ADC12 housing in white color with mirror finished aluminium reflector mounting kit for light control 15°/24°/32°/50° Beam Angle and 38° shielding angle. LED Used shall be COB type with system Lumens 1410 lm ±10%, fixture Life of : 50k hours L80B50, CCT of 3000K (SDCM≤3), IP20, CRI >90 for high quality light output. power factor >0.90 an operating Voltage Range of 220 - 240 VAC with Operating temperature range - 20 C -+45C. Fixture should comply with EMC / EMI with flicker free operations ripple <5%, BIS certification is required for LED Driver & Luminaire along with Class I classification The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should have separate BIS approval.
Supply, Installation, Testing and Commissioning of IP 20 IK03 LED Downlighter 12W LED, system lumen ≥ 100 Lm/w having PC Housing Body, CRI >80, THD <10%, CCT 5700-6500K, Surge Protection >2.5KV. Life 50000 Hrs. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, Testing and Commissioning of IP 20 IK05 Surface Mounted Batten 20W LED, system lumen ≥ 100 Lm/w having Aluminium Extrussion Housing Body, CRI >80, THD <15%, CCT 5700-6500K, Surge Protection >2.5KV. Life 50000 Hrs. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of 10 Watt LED Bracket light and minium system efficacy of 100lm/w. The luminare should have color temperature of 6500K and CRI>70. The luminaire shall meet IP65 rating HPF and The luminaire housing should made of pressure die-cast aluminium. The luminaire has the features of Input voltage: AC220-240V, 50/60Hz Voltage HPF High Surge Protection : 3KV Long life of LEDs 50,000* BH (L70) Confirmed to IEC Safety Standard (IEC60598, IEC61347) integrated LED Driver offers comfortable softlight, high durability.
Supply, Installation, Testing and Commissioning of 10W LED Mirror light including connections etc as required.
Supply, Installation, testing and Commissioning of 450mm dia exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supply, Installation, testing and Commissioning of Stylish, Robust & reliable in UP-Down light with aluminum housing offers uniform light distribution with IP 67 protection suitable for 15W LED gives nominal system lumen output of 800lm .The luminare should have beam angle of 24 Deg with a color temperature of 4000K and CRI>70. The luminaire shall meet IP67 rating HPF and The luminaire housing should made of pressure die-cast aluminium. The luminaire has the features of Input voltage: AC220-240V, 50/60Hz. High Surge Protection : 4KV Confirmed to IEC Safety Standard (IEC60598, IEC61347).
Supply, Installation, testing and Commissioning of Decorative 25 LED with 3.0 M pole aluminium housing offers uniform light distribution with IP65 Protection with 30 W LED will gives minimum system efficacy of 100lm/W.CCT 4000K and CRI>70. and The luminaire housing should made of pressure die-cast aluminium with glass diffuser and specially designed heat sink for better heat dissipation. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Decorative & cylindrical shape LED Bollard 8W LED nominal system lumen output of 400lm The luminare should have color temperature of 4000K and CRI>70. The luminaire shall meet IP65 rating HPF and The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Decorative & cylindrical shape 8 W LED Gate light nominal system lumen output of 400lm The luminare should have color temperature of 4000K and CRI>70. The luminaire shall meet IP65 rating HPF and The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Robust and reliable LED Narrow beam uplighter with aluminum housing offers uniform light distribution, high durability and IP67 Protection 4W LED with system lumen output of 40lm with a color temperature of 4000K and CRI>70. The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Design, fabrication, loading, unloading as directed by Engineer-in-Charge, supply of LT Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel 'T' irons and/ or flats wherever necessary, 16 gauge CRCA sheet steel shall be used for final distribution panels. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of zinc chromate primer and final approved shade of enamelled paint. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels. ACB: LSIG (Microprocessor Based) releases shall be used for incoming feeders such as Transformers and DG Sets & LSI releases for outgoing breakers. MCCB: MCCBs of above 250A Microprocessor Based and upto 250A thermal Magnetic releases. Breaking capacity mentioned is Ics value. This BOQ to be read in conjunction with technical specifications and Single Line Diagram (attached for reference). If any discrepancy occurs that should be brought to the notice of Client/Consultant before quoting the price otherwise stringent condition will be deemed to have been considered. All MCCBs shall be provided with rotary operating handle and ON/OFF lamps backed by 2Amp control MCB. All meters shall be digital type (unless otherwise specified) Multi-function meter to be provided as required to cover all the parameters as mentioned. All current/voltage transformer shall be cast resin type. All indicating lamps shall be LED type. Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus bar is after considering all derating factors. (Bus bar sizing calculation to be submitted for approval.) All internal control wiring shall be heat resistant type. All incoming breakers in Main LT panel shall be electrically interlocked. Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. All feeders shall be provided with door interlocked with door defeat, pad lock facility. Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. Spare contacts of ACBs/ MCCBs/ Relay/ Contactor shall be wired upto terminal block. 20% spare control terminal to be provided. All MCCBs shall be provided with variable O/L & S/C releases. Incoming MCCB shall be provided with E/F releases also. All incoming/outgoing cables shall be terminated on links/terminals. 3-phase Digital Energy Meters with RS -485 Port (Dual Source) with necessary CTs. 1.0 Main LT Panel : Main LT Panel shall Comprise of the following: a) Incomings: One (1) Nos. 1600 Amps, 415 V, 35kA four pole draw out, Electrically operated ACB, with ON/OFF/TRIP circuit healthy/Spring Charged indication lamp and TNC control switch, under voltage & shunt trip release, anti pumping protection microprocessor based O/C, Time Delayed S/C, Instantaneous S/C, E/F protection etc. complete as required for Transformer Supply Feeder. One (1) Nos. 800 Amps, 415 V, 35KA, 4 pole drawout type electrically operated ACB with ON/OFF/TRIP/Trip Ckt. healthy/Spring Charged indication lamp, TNC control switch, under voltage & shunt trip release, anti pumping protection, microprocessor based O/C, Time Delayed S/C, Instantaneous S/C, E/F protection etc. complete as required for DG Supply Feeder. b) Metering & indication for Transformer Supply incoming breakers: Each Breaker shall be provided with : i) One(1) No. multifuction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (Schneider EM6400NG or Equivalent make). ii) One (1) set 3 Nos. CTs of ratio 1600/5A,15VA, Class 1.0 as required. iii) One (1) set of 1600/5 A, C.L 1.0 CTs for input to APFC relay. iv) One set (3 Nos) phase indication lamp with backup SP MCB 2Amp. c) Protection Relays & Interlocking for transformer breaker: Each Transformer breaker to be provided with : i) One (1) no. REF (CAG14) or equivalent relay with stabilising resistance for transformer REF protection with 4 nos. 1600/1A,CL-PS CTs of suitable VA and knee point voltage. ii) One (1) Set of Numerical, Multifuntional protection relay suitable for Under voltage (27), overvoltage (59), Trip Circuit supervision (95) and Master trip relay (86) protections. d) Metering & Indication For DG supply breakers: Each Breaker shall be provided with:- i) One(1) No. multifuction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency,hour run, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (Schneider EM6400NG or Equivalent make). ii) One (1) set 3 Nos. CTs of ratio 800A,15VA, Class 1.0 as required. iii) One set (3 Nos) phase indication lamp with backup SP MCB 2Amp.. e) BUS BARS: 2000Amp., 35kA, TPN, Aluminium Bus bar with colour coded, heat shrinkable sleeves. (with 100% neutral). Separate earth Bus of 65 x 8 mm Aluminium shall be provided. f) Outgoing: Each outgoing feeder shall be provided with ON/OFF/Trip indication lamps,shall be provide with Dual source Energy meter with RS 485 port with one set of suitable ratio, 15VA, class 1.0 CTs. The Number of outgoing feeders shall be as follows. No energy meters shall be provided in spare feeders. i) 1 Nos. 630 A, 35 KA, TP MCCB (for Capacitor Banks, without Energy Meter). ii) 1 Nos. 630A, 4P, MCCB. iii) 3 Nos. 400 A,4P MCCB. iv) 2 Nos. 250 A,4P, MCCB. v)2 Nos. 160 A,4P, MCCB. vi) 7 Nos. 100 A,4P, MCCB. Main LT Panel, described as above (from a to f).
Supply, Installation, Testing and commissioning of Cat6 23 AWG Solid Copper Conductor UTP LSZH Cable roll of 305 Mtr, in accordance to IEC 60332-2-33, ANSI/TIA 568 C.2, UL 444, IEC 60754 -1,2 & 3, IEC 60134-2 and ISO/IEC 11801–2nd Edition, 250 Mhz tested and UL & ETL Listed Cable, Grey, RoHS Certified for Connectivity of Hub room to End Point.
Supply, Installation, Testing & Commissioning of CAT6 UTP JACK, Universal (tool/toolless), As per ANSI/TIA 568 A/B wiring system, UL & ETL Verified- Blue for Camera at user end.
Supply, Installation, Testing & Commissioning of loaded 12-Port 1U loaded Universal Modular Straight Patch Panel, pre loaded with cable support Bar, Individual port transparent shutter and labelling point, Preloaded earthing plug for surge protection. UL & ETL Verified. CRC Metal with Black Powder Coated. RoHS Compliant, in accordance to ANSI/TIA-568-C.2, ISO/IEC 11801:2002/AMMD.2:2010, YD/T 926.3-2009, ISO/IEC 60603-7 standards. Saftey parameters as per UL 94V-0, at rack end.
Supply, Installation, Testing & Commissioning of loaded 24-Port 1U loaded Universal Modular Straight Patch Panel, pre loaded with cable support Bar, Individual port transparent shutter and labelling point, Preloaded earthing plug for surge protection. UL & ETL Verified. CRC Metal with Black Powder Coated. RoHS Compliant, in accordance to ANSI/TIA-568-C.2, ISO/IEC 11801:2002/AMMD.2:2010, YD/T 926.3-2009, ISO/IEC 60603-7 standards. Saftey parameters as per UL 94V-0, at rack end.
Supply, Installation, Testing & Commissioning of Cat6 UTP 24AWG, Stranded Flexible, LSZH Jacket, in accordance to ANSI/TIA 568C.2 Patch Cord, Complying to UL94-V-0 BLUE 1 Mtr for rack side switch to jack panel connectivity.
Supply, Installation, Testing & Commissioning of Cat6 UTP 24AWG, Stranded Flexible, LSZH Jacket, in accordance to ANSI/TIA 568C.2 Patch Cord, Complying to UL94-V-0 BLUE 2 Mtr for rack side switch to jack panel connectivity.
Supply, Installation, Testing & Commissioning of 1/2/ 4 Port British Style Spring Shutter Face Plate with elegant 2 Piece design ABS-UL94-V2, 86x86x12.8 (mm). Straight white for I/O fixing at user side.
Supply, installation, testing and commissioning of Dome Camera , Resolution upto 5 MP , Quad stream with each stream support H.265 + compression simultaneously , fixed focal lens 3.6mm, 1/2.8" CMOS sensor Min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265+ ,H.265 ,H.264+ H.264 , frame rate : Main stream upto 5MP@25fps , substream upto 2MP@25fps , third and fourth stream upto VGA@25fps . Edge analytics :Motion Detection, Perimeter Intrusion, Line Crossing, Stationary Object, Face detection (deep learning), Cross counting, Pedestrian detection ,Inbuilt IR LED, IR distance upto 30 mtrs ,IP 66 , POE ,ONVIF profile S, G& T. UL, CE, FCC Certified.
Supply, installation, testing and commissioning of Bullet Camera , Resolution upto 5 MP, Quad stream with each stream support H.265+ compression simultaneously, fixed focal lens 3.6mm, 1/2.8" CMOS sensor Min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265+ ,H.265 ,H.264+ H.264 , frame rate : Main stream upto 5MP@25fps , substream upto 2MP@25fps , third and fourth stream upto VGA@25fps . Edge analytics :Motion Detection, Perimeter Intrusion, Line Crossing, Stationary Object, Face detection (deep learning), Cross counting, Pedestrian detection ,Inbuilt IR LED, IR distance upto 30 mtrs ,IP 66 , POE ,ONVIF profile S, G& T . UL, CE, FCC Certified.
Supply, installation, testing and commissioning of 8 channel NVR, ONVIF compliant , recording bandwidth 640 Mbps, output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16ch in/ 4ch out , 1 X RJ45 ethernet , iOS smartphone support, 8 HDD support , each HDD slot support upto 8 TB HDD, RAID support , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR . Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000 ,A.I maximum captured quantity 200,000. UL,CE,FCC certified.
Supply, Installation, Testing & Commissioning of 4TB Surviellance Hard Disk.
Supply, Installation, Testing and Commissioning of Full HD 32" LED Professional Display Panel.
Supply, Installation, Testing and Commissioning of Rack Mounted Industrial 12 port L2+ Managed switch having 24*10/100/1000Base-T POE ports, 4*100/1000Base-X uplink SFP ports, 1*RS232 Console port. Forwarding Rate @ 64 byte 38.69Mpps .Operation TEMP/ Humidity -40~+85°C.
Supply, Installation, Testing and Commissioning of Rack Mounted Industrial 12 port L3+ Managed Access switch having 24*10/100/1000Base-T POE ports, 4*100/1000Base-X uplink SFP ports, 1*RS232 Console port. Forwarding Rate @ 64 byte 38.69Mpps .Operation TEMP/ Humidity -40~+85°C.
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest.
UPS SYSTEM 1- Design, manufacturing, assembly, testing at works, supply, receiving at site, erection, testing and commissioning of true-online double conversion VFI Technology UPS, 1Ph/3Ph. AC input & 3Ph/1Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1% , PF 0.8 as required as per specification and consisting of following: a) Input range should be 320V AC-460V AC, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added. b) IGBT Rectifier Modules to achieve less than 2% Input Current distortion and greater than 0.98 PF at Input at all loads. c) Fully microprocessor based with diagnostics capability. d) Dual Input (Separate Input for rectifier and separate input for Bypass) e) Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per SLD. f) Design, manufacturing, testing at works, supply, erection, testing and commissioning of One sets of SMF VRLA battery with each UPS capacity as mentioned below, having back up time as mentioned below at full load, with interconnecting cables, cabinets and standard accessories as per specification and as required for the UPS system. (12V Cells) g) Battery shall be external type with rack and suitable for 15 minute backup on 100% load. Battery to be included in UPS cost 1 x 30 KVA UPS.
UPS SYSTEM 1- Design, manufacturing, assembly, testing at works, supply, receiving at site, erection, testing and commissioning of true-online double conversion VFI Technology UPS, 1Ph/3Ph. AC input & 3Ph/1Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1% , PF 0.8 as required as per specification and consisting of following: a) Input range should be 320V AC-460V AC, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added. b) IGBT Rectifier Modules to achieve less than 2% Input Current distortion and greater than 0.98 PF at Input at all loads. c) Fully microprocessor based with diagnostics capability. d) Dual Input (Separate Input for rectifier and separate input for Bypass) e) Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per SLD. f) Design, manufacturing, testing at works, supply, erection, testing and commissioning of One sets of SMF VRLA battery with each UPS capacity as mentioned below, having back up time as mentioned below at full load, with interconnecting cables, cabinets and standard accessories as per specification and as required for the UPS system. (12V Cells) g) Battery shall be external type with rack and suitable for 15 minute backup on 100% load. Battery to be included in UPS cost 1 x 60 KVA UPS.
Supply, Installation, Testing & Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved. Hooters Circuit.
Supply, Installation, Testing & Commissioning of Isolator Module for Isolating short/ dewired/ loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
Supply, installing, testing and commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved.
Supply, installing, testing and commissioning of 2 way communication Fire Fighter's Telephone Jack.
Supply, Installation, Testing & Commissioning of 1X100W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. 100 Watts
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 300 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 240 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 185 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 150 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 120 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 95 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 70 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 50 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 4 X 25 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 3½ X 35 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 4 X 16 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 4 X 10 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 4 X 6 sq. mm
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: -50 x 6 mm strip
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: -25 x 3 mm strip
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: -8 SWG wire
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. CU. Earthing Strip/Wire: 25 x 6 mm strip
Design, manufacture, loading, unloading, supply, Supervision of Installation testing and commissioning on location as desired by project manager or as shown in layout plan of 1000 KVA, oil filled 11 KV/433V, 3 phase, 50 Hz, delta/star connected with additional neutral of LT winding brought out to separate bushing terminal for earthing, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent, ON LOAD Tap changer with +5% & -15% tappings in steps of 2.5%, diagram & rating plate, oil temperature indicator, winding temperature indicator and buccholtz relay with wiring upto marshalling box, lifting lugs, first filling of oil, and weather proof 11KV HT cable box, LT cable chamber minimum 8mm thick non magnetic gland plate etc. complete as per specification and as per IS : 1180 latest amendment upto date. (The transformer shall be subject to all test specified in specification and test certificates shall be produced). The Transformer shall comply to IS: 1180, Losses shall be as per Level-II. Core shall be of prime metal grade CRGO with boltless design. Provision for CTs for REF protection shall be provided (CTs shall be provided loose as free issue item by the LT Panel Manufactrure to be fixed by Transformer Manufacturer either at site or works as the case may be) Voltage Ratio : 11 / 0.433 KV Vector Group : Dyn11 Tap Range [ON Load] : +5% to -15% step of 2.5% (As per IS : 1180) Insulation Class : 'A' Temperature rise of OIL by thermometer method @ 50 deg C over ambient (Shall bear as per IS : 1180) Temperature rise in winding by resistance method @ 55 deg C over ambient (Shall bear as per IS : 1180) Impedance : 5.0 % Terminal arrangement (HV) : 3C x 300 Sqmm 11 KV Terminal arrangement (LV) : 3.5C x 300 Sqmm Al ,XLPE Cable 1000 KVA Transformer as described above
Design, manufacturing ,testing at works and Supply Installation testing and commissioning of Radiator Cooled DG sets of following capacity (rating in kVA) compact packaged silent type, with Outdoor type Acoustic Enclosure to reduce the noise level as per requirements of central pollution control board, (72 db from 3 mtrs.) 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with Electronic Governer Suitable for Auto Load Sharing and Auto Synchronizing System complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), hospital silencer, common bed plate, anti vibration isolation pads, extended cable termination box, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 24 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. 500 KVA DG Set
Supply of HT Cable Supply of following sizes of 11 KV cables conforming to the data given below: Guaranted Technical Particulars for 11 KV Cables Conductor : a) Core/Size : 3 b) Material : Aluminium c) Shape : Circular d) Type : Stranded Insulation : e) Material : XLPE Inner Seath: f) Material : PVC(ST1/ST2) Type : Extruded g) Armour: Material : GI Type : Flat h) Outher Sheath: Material : HR PVC Type : ST 2 FRLS : Not required. Drum Length : As per Site requirement 3 C x 300 Sq.mm XLPE HT cable (Earthed)
6m-7mm Tall Aluminium Poles: Tech Specs MOC : Al Alloy grade 6063 using Billets of virgin Metal and tensile strength 145-186 mPa. All embellishments shall be used with GDC Aluminium LM6. Fe 410 grade steel to be used for pole base plate and Yst 240 Grade steel shall be used for pole tubes. M 16 Grade Foundation bolts shall be provided. V-Groove technique with MIG welding process shall be used between pole sections. Pole is to be provided with a surface mounting base plate, (steel of grade E250 to IS 2062 2011) and welded at the bottom of the pole with supporting gussets. The mounting plate shall be provided with elongated holes for alignment of the pole to suit M16 Bolt at CC 180. Hot dip GI foundation bolts and nuts (Grade 4.6 to IS 1367) shall be supplied with the poles. Once erected the Pole shall withstand the wind speed of 100 KMPH as per IS 875. PAINT : The base plate shall be hot dip galvanized (7 Stage process) as per IS 2629 before the coating of epoxy primer. The pole must be powder coated with a UV stabilised Zinc rich primer and baked at 200 degree C and then a second coat of the required colour TBC. The thickness of the painting shall be 90 microns (Primer -45 Microns + Painting - 45 Microns). Poles should be processed through an in-house process of shot blasting to remove all residual impurities on surfaces ELECTRICS : pole JB shall consist of 10A MCB with built in terminals for housing 3.5 Core 25 Sq. MM cable and diecast aluminium service door and safety chain. The pole shall be provided with built in 3 core. 2.5 Sq. MM cable from Pole Junction box to the luminaire. The brackets shall be a single piece assembly and should be capable of orientation in any direction and secured with stainless steel 304 grade allen grub screws.
High-performance floodlight. With symmetrically focused light distribution and reduced diffuse light percentage. LED, 270 W Luminaire connected wattage, Luminaire luminous flux 7935 lm, half beam angle 5∞, colour temperature 3000 K. Colour rendering index (CRI) > 80. With replaceable LED module with overheating protection and an expected service life of at least 50,000 operating hours. 20 years warranty of availability of LED module and wear parts. With LED power supply unit, DALI controllable or dimmable 1-10 V, 220-240 V, 0/50-60 Hz. Integrated changeover switch for the limitation of the luminous flux to 70 % ∑ 50 % ∑ 30 %. Protection class IP 67. Luminaire made of cast aluminium, aluminium and stainless steel , colour graphite. Safety glass. Reflector made of pure anodised aluminium. With : Highly efficient and low-loss light distribution, thanks to reflector and optical lens. One cable gland for power connecting cable up from ¯ 7.5 - 15 mm. Stainless steel mounting bracket with one centre hole 22 mm in diameter and two holes 9 mm in diameter, spaced 80 mm apart, and two holes 11.5 mm in diameter, spaced 200 mm apart. Dimensions: 500 x 530 x 220 mm.
10-12.0 M Octagonal streetlight Pole, single/ double arm long with Pole bracket shall be 60 mm diameter heavy duty galvanized iron pipes. A stopper shall be provided with 3 nos., holes at 120 degrees for proper fixing of the bracket on the pole top with rain cap., with following technical details Material of construction- Pole shaft - S355JO & Base Plate-MS-IS-2062 Metal protection Treatment both external and internal Side - H.D. GALVANISED-70 micron Avg. Thickness of Galvanisation - as per BSEN ISO 1461 Thickness of sheet - 3 mm Thickness of Base plate - 12 mm Bottom Diameter - 150 mm Top Diameter - 70 mm Number of foundation bolt - 4 PCD of Foundation bolt - 200 x 200 mm Bolt Diameter - 12 mm Foundation Bolt Length - 450mm J bolt Door Height (cut out) - 500mm Door Elevation - 500mm
Supply, Installation, Testing and Commissioning of IP68 underwater surface mount projector with spot/flood/wide/Elliptical beam angle. Installation depth upto 5meter. Fixture made up of stainless steel type316L, marine grade with crystal clear tempered glass. Fixture suitable for chlorine and saline environment with galvanic current protection. Fixture to be with thermal fold back technology. Vendor to provide all glare reduction accessories like snoot. Protection class IP 68 Dust-tight and protection against strong water jets, Impact strength IK10. Module connected wattage ranging from 3W-21W, Colour temperature 2700K/3000K/4000K/RGB, Colour rendering index CRI>85, SDCM<=3, Luminaire luminous flux ranging from 250lm-1500 lm, Luminaire luminous efficiency 84 lm/W, Service Life of LED: 60,000h (L80B50), Dimensions Dia: 38mm-104mm, W: 95mm-133mm,H:90mm-137mm Colour Finish: Stainless Steel.
Recessed ceiling and wall luminaire. Asymmetrical light distribution. LED, 6.5 W Luminaire connected wattage, Luminaire luminous flux 566 lm, colour temperature 3000 K. Colour rendering index (CRI) > 80. With LED power supply unit, DALI controllable?, 220-240 V, 0/50-60 Hz. With replaceable LED module with overheating protection and an expected service life of at least 50,000 operating hours. 20 years warranty of availability of LED module and wear parts. Protection class IP 65. Luminaire made of cast aluminium, aluminium and stainless steel , colour graphite. Safety glass, clear. Two cable entries for through-wiring power connecting cable up to 7-10.5 mm in diameter, 5 G 1,5 qmm. Dimensions of cover frame: 190 x 190 mm. Luminaire for installation in a recessed opening whose dimensions are 175 x 175 x 105 mm, or in installation housing or Installation housing for EWIS external wall insulation systems.
Recessed wall luminaire. Floodlight with adjustable light distribution. LED, 1.4 W luminaire connected wattage, 24 V DC, luminaire luminous flux 133 lm, colour temperature 3000 K. Colour rendering index (CRI) > 80. Without power supply unit. Protection class IP 68 20 m, safety class III. Luminaire made stainless steel, Steel grade no. 1.4301. Installation sleeve made of polyamide. Safety glass, anti-glare. Reflector surface made of pure anodised aluminium. With fixed, waterproof connecting cable 05RN8-F 2 x 1 qmm, length 3 m. Dimensions dia. 50 x 75 mm. Luminaire for installation in a recessed opening whose dimensions are dia. 45 x 100 mm, or in installation housing.
Spike or surface mount LED spot projector with color temperature of 3000K, 4000K or as per architect request with Luminous flux minimum 700lm. Fixture should have body in die-cast aluminium and glass sealed optical chamber. Fixture head should allows for 305° rotation and 135° tilt. Fixture should have wattage of 7W . Fixture CRI should be > 85 .Fixture should have atleast Lumen maintenance of 60,000 hrs at L80 B50 or heigher. Fixture should have symmetric beam distribution of 10-15°. Fixture should be compatible with honeycomb louvre as well as coloured ring, snoot, visor and adjustable elliptical lens accessory to get the desired lighting effect and minimum glare. IP rating of the fixture should be IP66 rated minimum. Fixture dimension should be 60mm (Dia) X 97mm (Length) X 130mm (Complete Height) or lesser.
Ceiling-mounted compact downlight. Symmetrical wide beam light distribution. Highly efficient and low-loss light distribution by means of reflector and optical lens. LED, 19.3 W Luminaire connected wattage, Luminaire luminous flux 2220 lm, half beam angle 39∞, colour temperature 3000 K. Colour rendering index (CRI) > 80. With replaceable LED module with overheating protection and an expected service life of at least 50,000 operating hours. 20 years warranty of availability of LED module and wear parts. With LED power supply unit, DALI controllable, 220-240 V, 0/50-60 Hz. Protection class IP 65. Luminaire made of cast aluminium, aluminium and stainless steel , colour graphite. Safety glass, clear. Reflector surface made of pure anodised aluminium. Two cable entries for through-wiring power connecting cable up to 10.5 mm in diameter, max. 5 x 1.5 qmm. Luminaire diameter 130 mm, height 135 mm.
Wall luminaire. Light emission on two sides. One light emission with narrow beam light distribution. Half beam angle 14∞ . One light emission with broad spread light distribution. Half beam angle 70∞ . LED, 39 W Luminaire connected wattage, Luminaire luminous flux 3064 lm, half beam angle 14/70∞, colour temperature 3000 K. Colour rendering index (CRI) > 80. With replaceable LED module with overheating protection and an expected service life of at least 50,000 operating hours. 20 years warranty of availability of LED module and wear parts. With LED power supply unit, DALI controllable, 220-240 V, 0/50-60 Hz. Protection class IP 65. Luminaire made of cast aluminium, aluminium and stainless steel , colour graphite. Safety glass panels. Reflector surface made of pure anodised aluminium. 2 screw cable glands with strain relief for through-wiring of the mains supply cable from ¯ 7-12 mm. Dimensions: 145 x 245 x 190 mm.
Supply, Installation, Testing and Commissioning of Recessed Mount grazer with 12x48 deg beam distribution. Luminaire with semi translucent / clear sealed encapsulation and Antiglare optics for optimal visual comfort. In combination with latest LED packages a thermal resistivity should be achieved for an optimal heat dissipation. Luminaire made up of anodised aluminium with tempered glass. Consistent light intensity all along the luminaire length should be obtained with active current regulation operated by dedicated integrated circuits (ICs) on each step. Protection class IP 67 Dust-tight and protection against strong water jets, Impact strength IK06.Luminaire connected wattage ranging from 18W-24W, Colour temperature 2700K/3000K/4000K, Colour rendering index CRI>80, Luminaire luminous flux ranging from 2067lm, Luminaire luminous efficiency 80 lm/W, LED psu: 50,000h LED module: 100,000h (L90B50). Dimensions L: 1000 W:20mm-28mmH: 30mm-35 mm. Length to be continuous as per drawings.
On-ground luminaire. Light emission 180∞. LED, 13.8 W Luminaire connected wattage, Luminaire luminous flux 604 lm, colour temperature 3000 K. Colour rendering index (CRI) > 80. With replaceable LED module with overheating protection and an expected service life of at least 50,000 operating hours. 20 years warranty of availability of LED module and wear parts. With LED power supply unit, DALI controllable, 220-240 V, 0/50-60 Hz. Protection class IP 67. Luminaire made of cast aluminium, aluminium and stainless steel , colour graphite. Crystal glass. Highly efficient and low-loss light distribution, thanks to reflector and optical lens. With fixed waterproof connecting cable 07RN8-F 5 G 1 qmm, length 1,8 m, with integral water stop and 1.2 m PVC conduit. With mounting plate for bolting onto a foundation or onto the connection housing. Dimensions: 210 x 150 mm.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. - 25 mm Dia
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. - 32 mm Dia
Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required. Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required. Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish 19mm thick closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Providing & Fixing in position the mercury in glass with industrial type thermometers.
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately.supported on rigid supports duly painted/buried in ground.excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from.minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 150 mm dia.
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately.supported on rigid supports duly painted/buried in ground.excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from.minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 125 mm dia.
Supplying, fixing, testing and commissioning of BUTTERFLY VALVE with CI body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified. - 150 mm dia.
Supplying, fixing, testing and commissioning of BUTTERFLY VALVE with CI body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified. - 125 mm dia.
Supplying, fixing, testing and commissioning of BUTTERFLY VALVE with CI body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified. - 50 mm dia.
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095 , with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. - 100mm dia.
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. - 65 mm Dia
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. - 50 mm Dia
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - Thickness 0.80 mm sheet
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. 65 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. 50 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. 25 mm dia. (19 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. 125 mm dia. (32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. 100 mm dia.(32 mm thick insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building & at terrace (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40-55 Kg / cu m density, insulation material shall be resistant to growth of Fungus as per ASTM C 1338 and resistant to growth of Bacteria as per ASTM E 2180,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation,with reinforced 7 mil woven glass fiber covering in and applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. 80 mm dia. (32 mm thick insulation)
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damper
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 125 mm dia Lever Type
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 100 mm dia Lever Type
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 65 mm dia Lever Type
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butter fly Valve(Manual) with CI body SS Disc,Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot water circulation as specified. 50 mm dia Lever Type
Supplying, fixing, testing and commissioning of BALANCING VALVE with built in measuring facility with C I body flanged construction with EPDM Coated disc with long pitch with protded out pipe insulation & PN 16 pressure rating as specified. - 125 mm dia.
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Balancing Valve with built in measuring facility with CI body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 100 mm dia
Non Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. It shall be of wafer type preferably with flanged ends. It should be tested for required hydrostatic pressure for shell & seat as per OEM & shall be suitable for maximum working temperature of 80 degree C (approx.).- 100 mm dia
Supplying, fixing, testing and commissioning of NON - RETURN VALVE with dual plate of CI body, SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. 125 mm dia.
Supplying, fixing, testing and commissioning of Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. - 125 mm dia.
Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified. - 100 mm dia
Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified. - 65 mm dia
Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified. - 50 mm dia
Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 4C- 6 sq mm
COOLING TOWERS Supplying, installing, testing and commissioning of CTI/JCI Certified Induced Draft FRP Cooling tower with VFD for fans of 90 TR 335160kcal/hr heat rejection capicity with FRP Water basin, PVC Filling with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor VFD controlled, efficiency class IE3 efficient, the cooling tower shall be compitable with suction screen, make-up, quick fill arrangement, overflow and drain connections with necessary valves, suitable inspection ladder, access arrangement for cooling tower interior, mesonary supporting structure, anti-vibration mountings etc. complete as per specifications and as reqd. The scope of work shall include Lifting, shifting & positioning of cooling tower at location shown on drawing. Ambint temperature Summar- 90 ⁰F DB, 82⁰F WB Monsoon- 82 ⁰F DB, 78 ⁰F WB Inlet temperature of Condenser- 90 ⁰ F Outlet temperature of Condenser- 97.5 ⁰ F Capacty-90TR (2w+0s)
Condenser Water Pumps Set Supply, installation, testing and commissioning of Inline Pump Vertical (close/long coupled) / Horizontal split casing, back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8)/ bronze impeller, high strength steel shaft (prefarably SS304) and MS fabricated base plate.The pump motor shall be suitable for 415±10% volts,50 cycles,3 phase AC power supply of minimum IE3 efficiency class. Motor shall be squirrelcage, Class F insulation,1500RPM (Max.) for above 450GPM &3000 RPM for lesser 450GPM. Pump, base, coupling and motor shall be factory assembled. adjustable & compleet in all resepct as per directions of E-I-C. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.)withplaster, Antivibration arrangement of cushy footmountigs are deemed to be included in this item cost. Suction guide to be provided by pump manufacturar for unit. Pump curves & loss calculations shall be furnished during approval from competant authority. Pumps shall be BMS compatible. Pump rating shall be PN 16 preferably. Contractor to submit proposed pump data with duty curve. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Water flow rate : 300 USGPM Head : 22m Efficiency(Min) : 75 % or nearest as per OEM Pumps complete in all respect (2 working+1 standby )
Primary Chilled Water Pumps Set Supply, installation, testing and commissioning of Inline Pump Vertical (close/long coupled) / Horizontal split casing, back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8)/ bronze impeller, high strength steel shaft (prefarably SS304) and MS fabricated base plate.The pump motor shall be suitable for 415±10% volts,50 cycles,3 phase AC power supply of minimum IE3 efficiency class. Motor shall be squirrelcage, Class F insulation,1500RPM (Max.) for above 450GPM &3000 RPM for lesser 450GPM. . Pump, base, coupling and motor shall be factory assembled. adjustable & compleet in all resepct as per directions of E-I-C. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.)withplaster, Antivibration arrangement of cushy footmountigs is deemed to be included in this item cost. Suction guide to be provided by pump manufacturar for unit responsability. Pump curves & loss calculations shall be furnished during approval from competant authority. Pumps shall be BMS compatible. Pump rating shall be PN 16 preferably. Contractor to submit proposed pump model with duty curve. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Water flow rate : 180 USGPM Head : 14m Efficiency(Min) : 75 % or nearest as per OEM Pumps complete in all respect (2working+1 standby )
Secondary Chilled Water Pumps Set With VFD Supply, installation, testing and commissioning of Inline Pump Vertical (close/long coupled) / Horizontal split casing, back pull out flexible coupled End Suction Pump mounted on a common base with electric motor for re-circulation of water for the central air conditioning system. The pumps shall be flexible coupled protected by OSHA complaint coupling guard, with CI casing, SS (CF8)/ bronze impeller, high strength steel shaft (prefarably SS304) and MS fabricated base plate.The pump motor shall be suitable for 415±10% volts,50 cycles,3 phase AC power supply of minimum IE3 efficiency class. Motor shall be squirrelcage, Class F insulation,1500RPM (Max.) for above 450GPM &3000 RPM for lesser 450GPM. . Pump, base, coupling and motor shall be factory assembled. adjustable & Pump motor shall be with VFD as per following pump capacity.and complete in all repect for operation. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Minimum efficiency of pump shall be as mentioned below. Cost for pump foundation, suitable support/Mounting Arrangement including making connection of inlet & outlet with fittings including nut, bolts, packing etc.) with plaster. Pumps Shall be BMS & VFD compatible. Suction guide to be provided by pump manufacturar for unit responsability. Contractor tosubmit proposed pump model with duty curve. Pump rating shall be PN 16 The entire work shall be complete as per specifications & as per directions of Engineer-in-charge. The chilled water pumps shall also includethe cost of thermal insulation. Secondary chilled water pumps shallbe suitable for operation on variable frequency drives & conforming tothespecifications of variable speed pumpingsystem. The capacity of motor shall be at least 10% in excess of BHP requirement of pump. Secondary Chilled water pumps Water flow rate : 180 USGPM Head : 24m Efficiency : 75 % or nearest as per OEM Pumps complete in all respect (2 working+1 standby )
Variable Speed Pumping System controller for Secondary Chilled Water /Hot water Pump Supply, installation, testing and commissioning of VSPS (variable Speed Pumping System) consisting of suitable variable frequency drive (VFD) for above menstion pump having IP 54/IP-55 enclosure with heat sink suitably interfaced with other system components, hand / auto macro designed for pumping application, . dedicated microprocessor based pump logic controller, parallel pumping software duly downloaded, Differential Pressure Sensor / Transmitters (or as required to meet the functional requirements), interfacing amongst all components and compatibility of I/O signals etc. complete with other accessories as required. It should be BMS compatible complete with other accessories as required. It should be complete as per manufacturer's Specifications & as directed by Engineer-in-charge. Suitable For operate 3 No.Secondary Chilled Water Pumps at same time(2w+1S)
Supply, installation, testing and commissioning of closed expansion tank system. Tank will be of M.S. construction with interchangeable EPDM-BUTYL rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations.the tank shall be fabricated as per IS 2825-1969 for non fire pressure vassel/ASME boiler section-8. For chilled water application, it will be insulated with 50 mm thick insulation to the specifications and cladded with 26G-aluminum cladding. The capacity of tank shall be 200 Liters
Pressurisation unit shall be with 2 nos. (1 working + 1 stand by) horizontal/vertical multi-stage pumps of suitable rating & capacity, as indicated hereunder, factory mounted on a steel frame along with interconnected piping, valves, strainer, pressure gauge, pressure transmitter, flow meter to measure the make-up water quantity, control panel with duty cycling and dry-run protection, electrical relays/contactors and interconnecting wiring:The unit shall be capable of Pressurising the system to the required pressure with suction from a break-tank located at least 1m above pump level. Flow 2CMH (60mwc)
Supply, installation, testing and commissioning of automatic control for Units for 2 pipe system ( cooling) consisting of snap acting digital thermostat, which will have provision of setting of room temperature, setting off on speed (High, Medium, Low). The quoted price of thermostat shall include the cost of 20mm MS conduits, control cabling, MS Box etc. as required. It shall include all accessories, mountings, wiring be tween thermost at & unit, terminations etc. (BMS Compatibility to be provided).
Providing and fixing in position the following Ball Valves duly insulated as per specifications and drawings. Ball valve shall be screwed type brass/bronze lever operated, quarter turn ball valve (screwed type) of full flow with bronze /forged brass hard chrome plated ball with setting & gland of superior quality of preferably PN 16 rating. 25 mm dia
Providing, fixing, testing & commissioning of resilient rubber lined double arch vibration eliminator expansion bellow suitable for raw water up to 45 deg. C temperature to provide relief from stresses at pipe flanges. It should be complete as per manufacturer's specifications & as directed by Engineer- in-charge.(PN 16 rating) - 100mm dia
Providing and fixing Auto air vents (Brass MOC) of following size
Providing and fixing in position the following water flow switch as per specifications:
FCU Kit (Valves Station) Fan coil Kit , suitable for 2 pipe installations for HVAC terminal units in cooling systems. Complete with: pressure independent control valve, three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports and filter cartridge.. Maximum working pressure 25 bar. Maximum differential pressure with actuator 5 bar. Nominal working Δp range 25–400 kPa. Working temperature range -10–120 °C. Ambient temperature range 0–50 °C. Strainer mesh size 800 μm. Medium: water and glycol solutions; maximum percentage of glycol 50 %. Dezincification resistant alloy body and adjustment headwork; stainless steel strainer mesh; EPDM diaphragm, obturator and seals. To be fitted with ON/OFF or Modulating actuators as per the requirement. 25 mm dia
Air - Dirt Separator Supply installation testing and commisioning of Deaerator-dirt separator. Flanged connections, complete with Brass drain valve 1” F (from DN 50 to DN 150), 2” F (from DN 200 to DN 300). complete with a set of concentric metal mesh surfaces to create the swirling motion required to facilitate the release of micro-bubbles and dirt to the surfaces. Epoxy resin coated steel body. Brass automatic air vent valve body. Stainless steel internal element. PP float. Brass float guide and stem. Stainless steel float lever and spring. EPDM hydraulic seals. Medium water and non-hazardous glycol solutions excluded from the guidelines of EC directive 67/548; maximum percentage of glycol 50%. Maximum working pressure 10 bar. Working temperature range 0–110°C. Particle separation rating down to 5µ. Working temperature range 0–100°C. Floor brackets as per site requirement. 125mm dia
Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. - 25 mm Dia
Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. - 32 mm Dia
Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. - 40 mm Dia
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately.supported on rigid supports duly painted/buried in ground.excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from.minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 80 mm dia.
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately.supported on rigid supports duly painted/buried in ground.excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from.minimum 7mm thick MS sheet for pipes of 400 mm dia and above. - 50 mm dia.
Supplying, fixing, testing and commissioning of POT-STRAINER of MS fabricated flanged ends with stainless steel strainer as specified. - 150 mm dia.
Supply, Installation, testing and commissioning Bellows type rubber expansion joints for water piping located at Pump inlet & exit. Complete with double bellows, tie rods, MS flanges, necessary hardware and gaskets etc., with insulation of following sizes: 125 mm dia.
Supply, Installation, testing and commissioning of Flow Switch with accessories as required.
Providing and fixing in position the following GI medium class cutto required length and installed with screw joints including the necessary fittings (bends, tees, unions, sockets etc) duly insulated with 6 mm thick aluminium cladded nitrile rubber tublar insulation as per specifications. - 50 mm dia
Providing and fixing in position the following GI medium class cutto required length and installed with screw joints including the necessary fittings (bends, tees, unions, sockets etc) duly insulated with 6 mm thick aluminium cladded nitrile rubber tublar insulation as per specifications. - 80 mm dia
Supply, installation, testing & commissioning of 100 mm depth vinyl fabric flexible duct connector with 25mm flange suitable for medium temperature and fire/smoke resistance. Meets the requirement of NFPA 701. Measured in surface area. - 100mm
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh bird screen as per specifications. Fresh air louvers (with dampers)
Supply and fixing of acoustic lining of supply air duct and plenum with 13 mm thick with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 and Class 1 Fire Performance and with antimicrobial protection and should pass Fungi Resistance as per ASTM G 21 and Bacterial Resistance as per ASTM E 21 complete with manufacturer's recommended Rubber based Adhesive in a blend of solvents etc complete as required.
Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 3C- 35 sq mm
Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 3C- 16 sq mm
Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 3C-2.5 sq mm
Supply of following size of 1.1KV grade multicore Copper conductor XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 2C-1.5 sq mm
Supply, installation, testing and commissioning of ducted Inline Fans of GSS construction duly powder coated (rectangular box type for upto 20 mm WG SP and circular type for 10 mm WG SP) with centrifugal blower and motor encased in sheet metal casing, canvas connection etc. The Fan motor shall be suitable for operation on 220 V± 10%, 50 Hz, 1 phase AC supply. The Fan assembly shall conform to specifications and in accordance with requirements of drawings and Schedule of Quantities. Air Quantity : 800 CFM Static Pressure : 10 mm wg Motorrating : As Required
Supply, installation, testing and commissioning of ducted Inline Fans of GSS construction duly powder coated (rectangular box type for upto 20 mm WG SP and circular type for 10 mm WG SP) with centrifugal blower and motor encased in sheet metal casing, canvas connection etc. The Fan motor shall be suitable for operation on 220 V± 10%, 50 Hz, 1 phase AC supply. The Fan assembly shall conform to specifications and in accordance with requirements of drawings and Schedule of Quantities. Air Quantity : 600 CFM Static Pressure : 10 mm wg Motorrating : As Required
Supply, installation, testing and commissioning of ducted Inline Fans of GSS construction duly powder coated (rectangular box type for upto 20 mm WG SP and circular type for 10 mm WG SP) with centrifugal blower and motor encased in sheet metal casing, canvas connection etc. The Fan motor shall be suitable for operation on 220 V± 10%, 50 Hz, 1 phase AC supply. The Fan assembly shall conform to specifications and in accordance with requirements of drawings and Schedule of Quantities. Air Quantity : 500 CFM Static Pressure : 10 mm wg Motorrating : As Required
Supply, installation, testing and commissioning of AMCA certified for sound and air performance (FEG) Tube Axial fan complete with tube casing in MS standard construction powder coated, aluminium impeller with adjustable blade angles, vibration isolator and directly coupled to TEFC Sq.cage induction motor, suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. The complete fan assembly shall be BSEN-1210-3-2002/UL listed for 250 Deg C 2 hours in accordence with power ventilator for smoke control systems etc as per specification complete as required. Air Quantity : 30000 CFM basement Static Pressure : 25 mm wg Duty : Fresh/Exhaust
Factory Fabricated Double Skin Air Washer Supply, Installation, Testing and Commissioning of package type air cooling unit having minimum efficiency of 90% saturation with double skin casing of 0.8 mm thick inner/outer sheet powder coated and 25 mm thick PU insulation. Fan section shall be DIDW forward curved centrifugal blower with V-belt driver TEFC type induction motor with IP-55 protection suitable for operation an 415 ± 10% voltage 3 phase 50 Hz and 1450 RPM. Wet section shall consist of 1.2 mm thick SS tank, CELDECK fill 200 mm thick. The tank shall have water strainer suction and drainer connection. 2 Nos. water circulation pump set mono bloc (1W+1S) with PVC piping for water distribution and 4 bend PVC water eliminators. Pump motors shall be suitable for 230/1/50 Hz /415/3/50 Hz. Air intake felling of metallic wire mesh 50 mm thick with mounting frames. 2500 cfm capacity with 45 mm static pressure for kitchen
Supply, Installation, Testing and Commissioning of dry type Ceiling/Floor mounted Scrubber comprising electrostatic section multi cell type with 16 G powder coated galvanised steel sheet housing of 16 G (1.4 mm) thick system, bottom drain and metallic mesh filter. The electronic air cleaner shall be the two- stage dual voltage plate type cells and efficiency of 90% as per ASHRAE test Standard for dry particulate. Ionizing- collecting cell of one-piece construction. Power supply shall be 100% solid state. on 200 to 240 VAC, 50HZ, 1Phase input with an LED light indicating the performance status. All unit shall be with factory fitted UV lamp as per specification etc complete as required. 3000 cfm capacity for kitchen
Supply, installation, testing and commissioning of Suitable SISW Backward /Forward Curved Exhaust Air Fan in double skin construction complete with TEFC Induction Motor, Drive Assembly, Base Frame, Vibration Isolators and other accessories etc as per specification complete as required. Capacity - 3000 CFM, 35 mm St. Pr.
16 gauge MS duct work welded construction. Duct shall have fire rated coating compound. Fire rated coating compound used forconstruction of fire rated duct work shall be protected with minimum 0.7mm to 1mm nominal thickness tested to properties as per the requirements of BS 476: 6 & amp; 7, including non-combustibility Class O and fire propagation - Class 1 surface spread of flame & amp; materials in accordance with building regulations.
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh bird screen as per specifications. Exhaust air louvers (without volume control dampers)
Supply, Installation and testing of GI back draft gravity damper for fan in accordance with the approved shop floor drawings and specifications, and shall also confirm to the BIS specifications.
Providing, fixing, testing & commissioning of fountain equipments & Features Such As Header, Nozzles, pump, inlet & outlet fittings, drain, filters, valves,pipes, pool cleaning kits lights & control panel etc. all Complete in all respect including T&P as per detail drawing and approved by department and Engineer-In-Charge.
AUDITORIUM SOUND & PROJECTION, STAGE FURNISHING Two-Way Line-Array Loudspeaker System with 1x12" / 2x8" LF & ≥2 HF components on constant curvature waveguide; for Passive or Bi-Amplified Operation, as per specifications (4+4+4 for L-C-R) Prefered Make : JBL/ Martin Audio/ EV or equivalent
Dual 18” Compact Bass-reflex Subwoofer at 600W, as per specifications. Prefered Make : JBL/ Martin Audio/ EV or equivalent
Two-Way Stage Monitor System with 15" LF , as per specifications Prefered Make : JBL/ Martin Audio/ EV or equivalent
Two-Way Monitor System for Control Room and Green Room as per specifications. Prefered Make : JBL/ Martin Audio/ EV or equivalent
Front fill loudspeakers, 2 way system with peak power 150W. Prefered Make : JBL/ Martin Audio/ EV or equivalent
Cinema Surround Speaker ; 50 Hz to 20 kHz Frequency Range; High Sensitivity, 95 dB SPL, 1 W, 1 m (3.3 ft); High Power Handling Capability: >140 watts continuous pink noise Prefered Make : JBL/ Martin Audio/ EV or equivalent
Power amplifier for line array speakers, subwoofers and stage monitors with 2000W @ 4 ohms per channel power output; as per specifications Prefered Make : Crown/ EV/ Martin Audio or equivalent
Power amplifier for control room and green room monitors with 200W @ 4Ohms per channel power output; as pper specifications Prefered Make : Crown/ EV/ Martin Audio or equivalent
Dual channel cinema amplifier with 500W at 4 ohm Prefered Make : Crown/ EV/ Martin Audio or equivalent
24-Channel 7- bus achitecture Digital Audio mixing console frequency response 20Hz- 20kHz,+0/-1dB,THD XLR input to Direct output <0.007%@ 1kHz, XLR input to mix output <0.008%@ 1kHz, Noise mic input <-128dBu, Mix <-85dBu, Crosstalk @ 1khz, input channel muting >98dB, mix routing cutoff 98dB, Aux send off <-94dB, Impedances Mic inputs 2k ohm, Line inputs > 10k ohms. Prefered Make : Soundcraft/ Yamaha or equivalent
2x6 Loudspeaker Management System w/ Display,RTA mic phantom voltage15v DC, Impedance 120 ohms, sample rate 48kHz, THD 0.002%, Prefered Make : DBX/ Bosch or equivalent
Dual 31-band Graphic Equaliser 1/3 octave bands, ISO frequency centers, +/- 12 input gain range and switchable 40Hz/18 dB per octave low-cut filters Prefered Make : DBX/ Bosch or equivalent
Advanced feedback suppression processor with 24 filters per channel . Prefered Make : DBX/ Bosch or equivalent
12 analog mic/line input, 8 analog output, networked signal processor with fault-tolerant bus . Prefered Make : BSS/ EV or equivalent
Dolby 7.1 Processor Prefered Make : Denon/ Onkyo or equivalent
Dynamic Vocal Microphone, polar pattern Cardiod, Frequency Range 70-20000 Hz, Sensitivity2.5mV/Pa, Impedance <600 ohms Prefered Make : AKG/ Shure or equivalent
Dynamic Vocal / Instrumental Microphone, polar pattern Cardiod, Frequency Range 60-20000 Hz, Sensitivity1.8mV/Pa, Impedance <600 ohms Prefered Make : AKG/ Shure or equivalent
50cm gooseneck cardioid Microphone, polar pattern Cardioid, Frequency Range 70-18000 Hz, Sensitivity18mV/Pa, Impedance >2000 ohms Prefered Make : AKG/ Shure or equivalent
Cordless Lavalier Microphone with UHF frequency, comprising of : Lapel mic, bodypack transmitter and receiver Bodypack Transmitter: Carrier Frequency 660 to 865 MHz, Audio Bandwidth 35Hz - 20 kHz, THD @ 1kHz 0.7% typ., RF output 10mW typ. (ERP), Detachable belt clip, interchangeable labels, Rugged mini XLR connector, Soft-touch Finish, On-Mute-Off switch. Diversity Receiver: Carrier Frequency 660 to 865 MHz, Audio Bandwidth 35Hz - 20 kHz, THD @ 1kHz 0.7% typ., Swiveling Antenna, On/off switch, LED metering, Metal case, unbalanced TS output jack, Professional balanced XLR Audio output Lavalier Microphone: Polar pattern Cardioid, Frequency range 15Hz - 18kHz, THD 118dB, Equivalent Noise Level 34dB-A, 3-pin mini XLR Prefered Make : AKG/ Shure or equivalent
Boundary Layer Microphone Prefered Make : AKG/ Shure or equivalent
Microphone Cables: High grade, professional, low-noise, 2-Core High conductivity PVC insulated in PVC jacket,shielded, copper cable with di-electric insulator with XLR male/female connectors of following lengths: 5 meter Prefered Make : Imported Cable with XLR connectors.
Microphone Cables: High grade, professional, low-noise, 2-Core High conductivity PVC insulated in PVC jacket,shielded, copper cable with di-electric insulator with XLR male/female connectors of following lengths: 10 meter Prefered Make : Imported Cable with XLR connectors.
Microphone Stands: Telescopic type Boom mic. Stand Small stand Make : K &M
Microphone Stands: Telescopic type Boom mic. Stand Big stand Make : K&M
Micrphone Connector Stage Junction Box: M.S. sheet made connector box, screw openable lid finished in stove enamelled paint accomodating connectors as detailed below Female XLR (Panel mount)
Micrphone Connector Stage Junction Box: M.S. sheet made connector box, screw openable lid finished in stove enamelled paint accomodating connectors as detailed below Female Speakon + Female XLR
PATCH CORDS ( for SYSTEM INTERCONNECT ) High grade, professional, low-noise, 2-Core High conductivity PVC insulated in PVC jacket,shielded, Copper Cable with di-electric insulator with XLR male/female connectors / EP Jacks / RCA Jacks.
WIRING SYSTEM : Microphone Lines: High grade, professional, low-noise, 2-Core High conductivity PVC insulated in PVC jacket, shielded, Copper Cable with di-electric insulator one end terminating into Stage junction box and other end with connectors. Preferred Make : Klotz
WIRING SYSTEM : Speaker Lines: 2-Core, High definition Speaker Cable, 2 x 2.5 sq. mm., PVC insulated in PVC jacket laid in existing conduits Prefered Make : Klotz or equivalent
WIRING SYSTEM : Speaker Lines : 2 core High definition speaker cable 2x 4Sqmm Prefered Make : Klotz or equivalent
MAIN CONTROL SYSTEM RACK M.S. Rack with Power indicator, power sockets and isolator fitted duly prewired to accommodate Control Room equipments e.g. Amplifiers, Controller, Equalizer etc.
Array Frame for Suspending up to 6 Line-array speakers Enclosures with 10:1 Design Factor. Includes 4 x Quick Release Pins, 2 x Shackles, 2 x Drop Levers. Prefered Make : JBL/ Martin Audio/ EV or equivalent
Installation, Testing & Commissioning
VIDEO PROJECTION SYSTEM DLP 3-chip Projector 9500+ ANSI Lumens , wide XGA Projector Prefered Make : Barco/ Christie-WX 10K-M or equivalent
VIDEO PROJECTION SYSTEM Long Throw Projection Lens Prefered Make : Schneider/ OEM or equivalent
VIDEO PROJECTION SYSTEM Motorised screen ( 24' x 18 ' ). Prefered Make : DRAPER or equivalent
VIDEO PROJECTION SYSTEM Video-Data Switcher cum scaler with 8 inputs ( 4 Data / 4 Video) with corresponding audio. Prefered Make : Kramer / Extron or equivalent
VIDEO PROJECTION SYSTEM Touch Control System with Wired Touch Control Panel of 15" , Emitter Probes ( as per requirment) , Button Designer Pad ( 1no.) complete with all accessories.. [ Touch control system to control audio-video equipments including screen movement.] Prefered Make : CRESTRON/AMX or equivalent
Video Conferencing System with ISDN/IP Compatability , Multipoint Station Connectivity , 2 external camera inputs. Including 4 PTZ cameras (Canon/ Sony) Prefered Make : SONY/ Polycom or equivalent
DVD Recorder Preferred Make: SONY/ SAMSUNG or equivalent
Supply & running of RGBHV Cable in meters/ Video
Installation, testing and commissioning
MAIN CURTAIN made out of velvet curtain cloth with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement & motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (L&T/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering.
CENTER CURTAIN made out of glazed cotton curtain cloth with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangements & motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1HP motor (Crompton) 2nos. air breaker contactors (L&T/SIEMENS), 2 nos. micro switches for auto stop, 3nos. push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering.
REAR CURTAIN made out of glazed cotton cloth with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel rope wire, 1HP motor (Crompton) 2 nos, air breaker contactors (L&T/SIEMENS), 2 nos. micro switches for auto stop, 3 nos. push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm. The curtain should be stitched in double gathering.
CYCLORAMA CUM SCREEN :- Providing and fixing cyclorama screen in plastic perforated material. The screen to be fixed on tubular frame made out of 35mm dia MS pipe. Appx. Size:-
WINGS :- Providing and fixing cloth wings made out of black glazed cotton cloth fixed on overhead pivote track
FRILLS :- Providing and fixing average frills made out of double gathering glazed cotton cloth to be installed above the stage on 28mm dia GI pipe.
50mm dia B class GI pipe to be hung from existing grid or roof structure for side wings, lighting bars.
50mm dia B class GI pipe grid at 1000mm c/c in both directions, suspended from roof truss as per drawing.
SITC of Pabble Convex spot light 2500W 230V/240V Lens Type 150mm dia, pebble-convex, Reflector 100mm dia. Aluminium, Colour Gel Dimension 185x185mm, Throw 2-17m, Beam angle 8degree-60degree Type: TONOPC 2000 Plus of LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
1000W, 240 Volt, PAR Sealed Beam Light with CRC Sheet Metal and aluminum die casting, mat black color/aluminum & yoke. Type: PAR-64 (With Lamp) Make: DTS/ Selecon/ ETC or equivalent
SITC of Pabble Convex spot light 1000W 230V/240V Lens Type 150mm dia, pebble-convex, Reflector 100mm dia. Aluminium, Colour Gel Dimension 185x185mm, Throw 2-17m, Beam angle 8degree-60degree Type: ARIA-PC1000 Plus of LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
SITC of 1200W profile light with Double condenser & zoom, 68mm dia. Glass reflector, 185 x185mm colour frame, narrow beam angle, GX9.5 lamp base, 5-25m throw, 14,3 Kg net weight in 10853020 Black colour. Type:NOTA 8/22 of LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
SITC of Lens Type 150mm dia. Fresnel, Reflector 100mm dia. Aluminium, Colour Gel Dimension 185x185mm, Throw 2-15m, Beam angle 10degree-56degree. Type: ARIA-F1000 PLUSof LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
650/1000/1250W flood light with aluminum Asymmetrical reflector, double pole micro switch, 290x270mm color frame, R7s lamp base, 2-10m throw, 5,3 kg weight in 10806050 Black, (10806051) white/ (10806052) Silver color. Type: INNO A 1000 of LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
SITC of Lens Type 150mm dia. Fresnel, Reflector 100mm dia. Aluminium, Colour Gel Dimension 185x185mm, Throw 2-15m, Beam angle 10degree-56degree. Type: ARIA-F1000 PLUSof LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
650/1000/1250W flood light with aluminum Asymmetrical reflector, double pole micro switch, 290x270mm color frame, R7s lamp base, 2-10m throw, 5,3 kg weight in 10806050 Black, (10806051) white/ (10806052) Silver color. Type: INNO A 1000 of LDR or equivalent models in Selecon/ ETC Make: LDR/ Selecon/ ETC or equivalent
6 Channel Splitter Make: Modern Stage Service/ Canara / Effectron
Ladder M.S. Pipe Ladders to be provided on sides of the Stage to be fixed on the existing GI pipe or top grid. Made of 50mm x 25mm MS pipe of following Size: -
Dimmer and Controller Electronic Dimmer Rack with 192 nos single phase 2 KW electronic dimmers to be distributed in 3 phases with suitable bus bar arrangement housed in sheet metal enclosure. Digital output, output light indicator, local controls etc. Make: Modern Stage Service/ Canara / Effectron or equivalent Type: Type: XL-10-192 of Modern Stage Services
Inter connection wiring for Dimmer to Control Room with required connectors.
Points Wiring
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid