Ex. Engineer Electrical SKIMS
Ex. Engineer Electrical SKIMS Soura
Fresh Electrification which includes providing and fixing of LED Luminaries Fans and safety Devices etc in existing Mechanical Sub Division at SKIMS MCH Bemina necessitated due to addition alteration by Civil Division
2020_SKIMS_96883_1
eNIT SIMS HEE EET 17 of 2020-21 Dt.15.05.2020
Open Tender
Electrical Works
Item Rate
10 days
SKIMS MCH Bemina
Please refer Tender documents.
6 documents required · 6 mandatory
₹100
Yes
CAO SKIMS MCH Bemina
Yes
15 Sept 2020
16 May 2020
15 Jun 2020
16 May 2020
11 Jun 2020
18 May 2020
270 days
Amount
Providing, making of fresh lighting point, ceiling fan ,exhaust fan and 6 amp socket out let points (5-6 amp) exposed,using PVC in double locked PVC channel 25x1.6 mm thick or PVC conduit 1" dia 1.5 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) (Havells/Finolex/ Polycab/Paramount make FR) complete with P/F of switch 5/6 amps F/T (SSK/Havell's Reo/Anchor penta pc make) to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point.
Wiring to be carried out for fresh heating point in surface manner through pvc Channel of 25 x1.6 mm using multi strand 3 x 2.5 mm.sq pvc insulated copper wire (Havells/Finolex/ Polycab/Paramount make FR) complete with P/F of switch socket combine 15/16 amps 5 pin F/T ( SSK/Havell's /anchor penta pc make) to be fitted on Bakelite sheet suitable size, M.S/Wooden box, rowel plugs & screws etc. complete Point with civil work .
Wiring to be carried out for 16 amps socket outlet and circuit wire for light points along with earth wire of following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed in thePVC conduit or PVC cassing as required at site and complete with civil work at site (excluding the cost of conduiting /Casing ).
2.5 sq.mm copper wire multistrand PVC insulated P+N+E for light points ( 04 ckts ) of 3x2.5 mm2( Single wire)
1x 4 sq.mm copper wire multistrand PVC insulated for heating points 4 nos.
Providing fixing double locked medium duty pvc channel 25x 2mm. ((Flair/ Ravindra/Atul make)
Providing and fixing of 16 amps socket out let 5 pin Havell's Reo/ SSK make.
P/F of Socket 5/6 A 5 pin F/T for system Havell's Reo/ SSK make.
P/ F of Apollo hanging light (fancy type light)
Providing and fixing of Led 1200 mm long batten 6000/6500k Light having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 85 with minimum sytem lumens 2000 and maximum wattage 22 including connection with multistrand copper conductor 3 core cable etc as required at site.( Philip's/ Havel's/Wipro/ Trilux make )to be installed in four roors and corridor
provinding and fixing of ceiling fan copper wound heavy duty 1200 mm sweep (Havells / crompton/ Bajaj make).
provinding and fixing of iron fan hooks/ fan box of suitable size complete as required.
provinding and fixing of Fan regulater stepped type one way complete as required.
provinding and fixing of exhaust fan 250 mm shutter type plastic (Havells / crompton/ Bajaj make).
Providing fixing of ply board 12 mm thick suitable size for above mentioned exhaust fans ( 15"x 15") with central hole and screws etc. complte with civil work.
providing and fixing of bakelite sheet 3 mm thick of various sizes. As required at site. For 16 amps socket out let's, 6 amps socket and inspection boxes.
Supplying and fixing 10 way, single pole and neutral, sheetsteel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required (SSK /Havells/Indo Asian/Schneider make)
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load of following poles in the above MCB DB complete with connections, testing and commissioning etc. as required. (Legrand/Schneider acti -9/Siemens Hager make)
P/F of MCB Double pole 63 A 240/415 volts "C" curve 10 KA as main to be fixed in above DB .
P/F of MCB SP 10A to 32A for lighting and heating points to be fixed in above mentioned DB's
M/s Skyline Builders
AL BURJ CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .