Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹46.1 L+₹2.7 L (6.12%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED | |
| 3 | L3₹46.4 L+₹2.9 L (6.74%)Rejected-AOC VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC NOT ACCEPTED | |
| 4 | L4₹46.9 L+₹3.4 L (7.84%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED | |
| 5 | L5₹48.8 L+₹5.3 L (12.3%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹96,960
Closing Date
26 Dec 2020, 6:00 pmClosed
GE (SOUTH) UDHAMPUR
GE (SOUTH) UDHAMPUR C/O 56 APO
SPL REPAIR TO STAGING AND CAGING OF WATER TANK FOR SINGLE LIVING ACCN PROVN OF STORE ROOM NEAR BLDG NO P-110 TOILET NEAR BLDG NO CP-04 OF CP COLONY ADDN/ALTN TO BLDG NO T-78 (EXAM CUM LECTURE HALL) OF HRDC ROOF AND CERTAIN MISC WORK IN BLDG NO NP-37
2020_MES_398818_1
GE/S(U)-52/2020-21
Open Tender
Civil Works
Item Rate
240 days
HQ NC HRDC CP COLONY NCCIU
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (SOUTH) UDHAMPUR
₹96,960
Yes
10 May 2021
27 Nov 2020
28 Dec 2020
27 Nov 2020
26 Dec 2020
12 Dec 2020
27 Nov 2020 - 7 Dec 2020
Amount
Surface dressing not exceeding 15 cm deep in hard/dense soil and removal of surplus material out side MOD land complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation in any type of soil complete all as specified and directed.
Anti-termite treatment of bottom and sides of excavation at the rate of 5 ltr of emulsion per square metre of surface area complete all as specified and directed by Engr-in-Charge.
Anti-termite treatment of the top surface of filled earth at the rate of 5 ltr of emulsion per square metre of surface complete all as specified and directed by Engr-in-Charge.
Anti-termite treatment of the soil under plinth protection at the rate of 5 ltr of emulsion per square metre of surface complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated soil to a distance exceeding 50 m and not exceeding 1.50 km out side defence land complete all as specified and directed by Engr-in-Charge.
PCC 1:4:8 type C-2 (using 40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and directed.
Reinforced cement concrete (nominal mix) type B-1, 1:2:4 (using 20 mm graded aggregate) in footing, foundation beams, plinth beam, roof beam, lintel band and similr work etc. complete all as specified and directed.
Reinforced cement concrete (nominal mix) type B-1, 1:2:4 (using 20 mm graded aggregate) in columns, pillars and similar work etc. complete all as specified and directed.
RCC type B-1 1:1 1/2:3 (using 20 mm graded aggregate) for slabs supported on walls beams and columns in floors, roof, landing, balconies, canopies slabs and in shelves and the like complete all as specified and directed.
RCC type B-1 1:1 1/2:3 (using 20 mm graded aggregate) for chajjas complete all as specified and directed.
Form work to edges of concrete flat slats sides of RCC/PCC bands etc in walls horizental or slopping exceeding 10 cm but not exceeding 20 cm wide rough finished surfaces complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, landing and similar work not exceeding 200 mm thick complete all as specified and directed.
Form work to chullahah hoods chajjs, trought and similar items rough finished surfaces of concrete complete all as specified and directed.
Form work to sides and soffit of floor or roof beams, lintels beam, coloumn and similar work etc. complete all as specified and directed.
Mild steel TMT bars 8 mm dia and over and over cut to length bent to shape required including cranking, bending spirally including mild steel wire not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Mild steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binder TMT bars cut to length bent to shape required including cranking, bending spirally including mild steel wire not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Brick work with sub class 'B' brick, straight or curved on plain exceeding 6 m Mean radius built in type CM 1:6 complete all as specified and directed.
Rendering 15 mm thick in CM 1:6 on brick work/ stone work and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15 mm thick in CM 1:4 on brick work/ stone work and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5 mm thick in CM 1:3 on ceiling and exposed surface of concrete finsihed even and smooth without using extra cement complete all as specified and directed.
Preparing new plaster surface of walls and applying two coat of oil bound distempers over one coat of primer and two coats of wall care putty complete all as specified and directed.
Preparation of new plaster surfaces applying two coats of cement base paint and over one coat of primers complete all as specified and directed.
Preparation of new plaster surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Hard core of guage not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
75 mm thick PCC 1:4:8 type B-2 (using 40mm graded aggregate) as in sub base of floor etc complete all as specified and directed.
15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surface in CM 1:4 on vertical surfaces/backing coat complete all as specified and directed.
All as per ser item No 30 above but in vertical surfaces such as skirting/dado etc complete all as specified and directed.
Cement concrete 1:3:6 type C-1, 75 mm thick (using 20 mm graded stone aggregates) as in plinth protection finished fair and even with using extra cement complete all as specified and directed.
Framed work such as grill, gratings etc. with ends of bars shouldered and/or riveted or forged in to spikes, framed guard bars, barred iron doors ladders framed balusters and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
Preparation of new steel surfaces and applying two coats of synthetic enamel complete all as specified and directed.
Sheet glass 3 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in Each pane complete all as specified and directed.
105 x 60 mm pressed steel frames for doors with one or more rebate including necessary fixing lugs, hinges lock strike plate etc complete as specified including a coat of shop coat zinc chrome primer complete all as specified and directed.
Factory made 35 mm thick 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick complete, all as specified and directed by Engr-in-Charge.
100 mm size mild Steel butt hinges medium weight cold rolled complete all as specified and directed.
300 mm long aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
Floor door stoper (140 mm length) of aluminium alloy body complete all as specified and directed.
150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
150 mm length aluminium handles fabricated type anodised complete all as specified and directed.
Preparation of new wooden surfaces of any description, not other wise described over 10 cm width or girth applying two coats of synthetic enamel paint over a coat of primers complete all as specified and directed.
2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, puttogether with glue pinned at joints, 2nd class HW complete all as specified and directed.
18/19 mm thick block board, grade 2 quality, interior grade, commercial type fixed with screws to timber frame work/iron frame work (Termite treated/water proof) complete all as specified and directed. Make : Green Ply/Kit ply.
0.9 mm thick decorative choice of lamination type-1 of surface finish, colour and pattern as approved adhesive as per manufacturers instructions complete all as specified and directed.
2nd class HW plain fillets squre, rectangular or triangular in section clean sawn, secured with nails or brads exceeding 3 sqcm but not exceeding 6 sqcm complete all as specified and directed.
Hasp & staple 100 mm size aluminium anodised fixed with screws complete all as specified and directed.
Stain less steel catcher of superior quality complete all as specified and directed.
50 mm stain less steel pivoted type hinges of superior quality and complete all as specified and directed.
75 mm long aluminium alloy handles, fabricated type, anodised (ISI Marked) all as approved and complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
110 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
Hard core broken stone or boulders of gauge exceeding 63 mm but not exceeding 100 mm, deposited spread and levelled in layers not exceeding 15 cm thick watered and rolled/ ramed to a true surface complete all as specified and directed.
100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded aggregate) as in sub base to floor complete all as specified and directed.
15 mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:4 complete all as specified and directed.
Cement concrete colored chequered tiles machine pressed with imported pigment finish (gloosy finish) of size 300 mm x 300 mm x (30 to 40 mm) thick set and jointed with neat cement slurry complete all as specified and directed.
Kerb stone of size 300 mm x 300 mm x 100 mm thick made of precast cement concrete 1:2:4 type B-0 (using 12.5 mm grated crushed stone aggregates) including earth work for laying kerb stone complete all as specified and directed by Engr-in-Charge. Make : Ruchi or equivalent in performance of makes as specified in PS.
Applying two coat of rubber chlorinated high build coating synthetic enamel paint on concrete surfaces over a coat of primer including necessary preparation complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in bed block, hold fast and similar work complete all as specified and directed.
Taking up or down GI tubing 15 mm dia complete all as specified and directed.
GI tubing of 15 mm bore medium grade with all fittings completely fixed to walls or laid in floors etc. complete all as specified and directed.
Taking up or down GI tubing 20 mm dia complete all as specified and directed.
GI tubing of 20 mm bore medium grade with all fittings completely fixed to walls or laid in floors etc. complete all as specified and directed.
Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and complete all as specified and directed.
Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 15 mm bore and complete all as specified and directed.
Disconnecting existing tanks of exceeding 250 but not exceeding 500 ltr capacity setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc. complete all as specified and directed.
Disconnecting existing tanks of exceeding 500 but not exceeding 1000 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc. complete all as specified and directed.
Disconnecting existing tanks of exceeding 1000 but not exceeding 2000 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc. complete all as specified and directed.
Dismantling of 1000 ltrs capacity water tank of any description including all connection and removing from site complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 Ltr capacity (cylindrical veritcal with closed top) with threaded cap hoisted and fixed in position complete all as specified and directed.
Ball valves 20 mm size high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 20 mm bore pipe and fixed (Minimum weight 210 gms) complete all as specified and directed.
Dismantling of 500 ltrs capacity water tank of any description including all connection and removing from site complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical veritcal with closed top) with threaded cap hoisted and fixed in position complete all as specified and directed.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washingg down with water to remove dust etc including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete all as specified and directed.
PCC 1:2:4 type B-1 (using 12.5 mm graded aggregate) as in level course on roof surface 25 mm thick etc complete all as specified and directed.
Rendering 10 mm thick in CM 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas, finished the surface fair and even with out using extra cement complete all as specified and directed. Note : Supply of water proofing compound will be measured and paid separately.
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in base of water tank on roof surface complete all as specified and directed.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Minimum weight of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm including two coats of bituminious aluminium paint complete all as specified and directed. Note : Certain places to water tank staging area to consider.
Brick work with sub class 'B' brick straight or curved on plan exceeding 6 m radious in CM 1:4 as in brick work/brick pillars etc. complete all as specified and directed.
Plates (Plain or chequered) channels, square cut or notched (oridinary and counter sunk) forming holes, without any attatchment confirming Fe 410 W (Gde-E-250) qty A complete all as specified and directed.
Rolled Mild steel sections as in frame work for water staging, main and cross beams hip and jack rafters, purlines fixed independently including welding with MS butt hinges and also bldg height G+2 complete all as specified and directed by Engr-in-Charge.
4 mm dia galvanised steel wire mesh (25 mm x 25 mm) made up in to matresses or cages etc complete all as specified and directed by Engr-in-Charge.
MS flat iron for water staging and similar work including securing bolts etc complete all as specified and directed.
Preparation of new steel surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Dismantling asbestos corrugated or semi corrugated sheets as in roof covering including ridge etc. complete all as specified and directed.
Dismantling timber scantling over 40 sqcm in section in any position complete all as specified and directed.
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick crimpted/tapard at the external end slop of any colour having tansile strength 550 Mpa as in roof covering fixed with self tapping screws and caps etc complete all as specified and directed.
Plain galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick in ridges, hips, valley gutters at the external end slop of any colour having tansile strength 550 Mpa as in roof (ridges) covering fixed with self tapping screws and caps etc complete all as specified and directed.
Providing false ceiling GI frame work for seamless ceiling comprising of GI perimerter channel 0.55 mm thick with two unwqual flages of 20 to 30 mm and web of 27 mm fixed to surrounding wall using screws at 452 mm C/C channel 0.9 mm thick having two wqual flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm C/c with GI cleat and steel expansion or sutable hanging from soffits \ trusses \ bracking supporting hanger compressing of GI wire complete all as sepcified and directed by Engr-in-Charge.
4 mm thick 600 x 600 mm size E-boards designer ceiling (Make; Everest of equvalent), fixed to GI grid work with screws and applying new surfaces two coat of distempers and one coat of primers complete all as specified and directed.
Providing 50 mm thick cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) as in plinth protection finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Taking down frames with shutters (without taking off shutters from the frame) area not exceeding 1.5 Sqm Each including iron mangery complete all as specified and directed.
Taking down shutters of any description exceeding 1 square metre not exceeding 2 square metre each complete all as specified and directed.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per ser item No 96 as above here in before but without glazing bar complete all as specified and directed. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
3 mm thick glass sheet oridinary quality in steel or wooden frames complete with fixing materials such as putty, glazing pins, wooden beads etc. complete all as specified and directed.
Galvanished mild steel wire cloth 0.56 mm nominal dia of wire and average width of apperature 1.18 mm complete all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fasterinings and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
Rolled mild steel work of angle iron as in frames of doors, Cup boards, grid framed work and any discription etc confirming to grade Fe 410-O or Fe 310-O complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed.
PCC 1:3:6 type D-2 (using 20 mm graded stone aggregate) as in sub base of floor mass concrete or similar work complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Preparation of new/old plastered surfaces of wall applying two coats of oil emulsion distemper over one coat of primer including complete all as specified and directed.
Two coats of cement base paint over a coat of alkali resistant priming paint inluding preparation of newly plastered surfaces complete all as specified and directed.
Screed bed or bedding layers of 20 mm thick cement mortar 1:4 for laying floor finishes complete all as specified and directed.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slabe including rubbing and mirror polishing complete all as specified and directed.
Machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing with 15 mm thick of CM (1:3) screed bed including taking down cement plaster complete all as specified and direceted by Engr-in-Charge.
Steel locking bolt with mild steel electro galvanised plate and bright bolt not less than 10 mm dia 100 mm size complete all as specified and directed.
Complete removal of existing treatment walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
Preparation of old surfaces and applying one coat of internal emulsion distember on walls complete all as specified and directed.
Preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Damp proofing course to horizantal or vertical surface including form work in PCC 1:2:4 type B-1 25 mm thick complete all as specified and directed.
75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base floor complete all as specified and directed.
75 mm thick for PCC 1:3:6 (using 20 mm graded aggregate) as in plinth protection using extra cement complete all as specified and directed.
Non skid ceramic coloured tiles 400 x 400 x 7 mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Glazed ceramic tiles in vertical surface but 600 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Preparation of new plaster surfaces wall surface applying three coats of white wash complete all as specified and directed.
RCC type B-1 1:1 1/2:3 (using 20 mm graded aggregate) for for lintals bends and roof bends complete all as specified and directed..
TMT bars 10 mm dia and over and cut to length bent to shape required including cranking, bending, hooking ends and bending with MS wire not less than 0.9 mm dia or securing with clips quality confirming complete all as specified and directed.
Solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour sheet reinforced with MS square tube all as per specififcation and drawing and complete all as specified and directed by Engr-in-Charge.
Factory made solid PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom railsMS frame shall be coverred with heat moulding plain colour PVC C channels having a PVC sheets strips of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail ,laock rail & bottom rail on either side &as gap insert for top rail & bottom rail panelling of plain colour PVC sheets to Be fitted in the MS frame welded/sealed to the stiles & rails with suitable complete all as specified and directed.
100 mm size butt hinges extruded aluminium alloy with galvanised with galvanised mild steel hinges pin anodised type B-2 complete all as specified and directed.
200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
Steel Ventilators with top hung shutters including hinges steel peg stay complete all as specified and directed.
GI tubes 15 mm dia medium grade laid in trenches or fitted on walls complete all as specified and directed.
GI tubes 20 mm dia medium grade laid in trenches or fitted on walls/floor complete all as specified and directed.
110 mm PVC (SWR) branch piece, (singal T) equal or unequal with access door complete all as specified and directed.
110 mm PVC (SWR) vent cowl complete all as specified and directed.
75 mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete all as specified and directed.
75 mm PVC (SWR) pipes single socket in any lenth with rubber ring joints fixed to wall complete all as specified and directed.
75 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
PVC (SWR) gully trap 110/125 mm, settting and jointing with solvent cement in repair complete all as specified and directed.
Vitreous china ware wash down water closet pan, (pedestal pattern) coloured including connection to drain and to flushing pipe, anti syphonage pipe etc. complete all as specified and directed.
10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve float and handle complete all as specified and directed.
Vitreous china white wash hand basin (flat back or angle back type) size 550 x 400 mm white including brackets, pedestal, wast fittings brass chromium plated, CP waste cupling, 32 mm dia, waste pipe, PVC connection 15 mm bore with PTMT nuts of length including 15 mm dia CP piller tap fancy type complete all as specified and directed.
CP Bib taps cast copper alloy with crutch or butterfly handle two bay, screwed for iron pipe of dia 15 mm, fancy type fixed complete all as specified and directed.
CP angle valves cast copper alloy, fancy type, with iong shank and cup, bore 15 mm fixed complete all as specified and directed.
125 mm dia brass chromium plated shower rose with swivel joints complete all as specified and directed.
600 mm long tubular tower rail brass chromium plated 20 mm dia, D type 60 cm long fixed with two plugs (Gutties) of 2nd class hard woodembeded in cement mortar 1:3 with MS screws complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation or manholes etc. and area not exceeding 10 Sqm on plan and getting out in any type soil complete all as specified and directed.
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete type D-2 (1:4:8) for 150 mm dia pipe complete all as specified and directed.
SWG drain pipe grade 'A' of 150 mm internal dia laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed.
Cement concrete type D-2 (1:4:8) (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4) complete all as specified and directed. Note :- reinforcement will be measured and paid seperately.
MS flat iron as in wind ties etc. confirming to fe 410-0 or Fe 310-0 including clamps complete all as specified and directed.
Rolled section as in main and cross beams , purlins, rafters, posts where connected to common rafter and running rails,eves board framing work, tank staging work etc. confirming to Fe-410-W complete all as specified and directed.
1.25 mm thick plain black mild steel sheeting in ridges hip, valley gutters drip and gutters and straight flashings (Length and girth as fixed) in repair complete all as specified and directed.
Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members, frame etc. complete all as specified and directed.
20 mm ball valve high pressure with polythylene float valve and fly nut complete screwed for iron pipe PTMT complete all as specified and directed.
10 mm thick rendering in cement mortar (1:6) on other than fair face of brick/stone or concrete surface complete all as specified and directed.
Two coats of distemper oil emulsion over a coat of primer including preparation of new plstered surfaces of walls over a two coat of wall putty complete all as specified and directed.
Preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint (APEX Aultima or equivalent) over a two coat of wall care putty complete all as specified and directed.
Complete removal of existing treatment (using removal machine) including preparing surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX Aultima or equivalent) over a two coat of wall care putty etc. complete all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bound distemper over a coat primers with two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
Providing 75 mm thick cement concrete (1:2:4) type B-1 (using 20 mm graded aggregate) as in plinth protection finished surface even and fair without using extra cement complete all as specified and directed.
Applying two coats of oil bound distamper on new surfaces of desired finish as approved and complete all as specified and directed by Engr-in-Charge.
Applying two coats of cement based paint over a coat of chalk whiting including preparation of new plastered surfaces complete all as specified and directed.
One coat of cement base paint on old plastered surfaces including preperation complete all as specified and directed.
Dismantling of PVC Pipes of dia 75/110 mm complete all as specified and directed.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round stays including bolt and nuts and securing ends of stays to wall or rod for 110/150 mm bore PVC pipe upto G+1 complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in any type of soil complete all as specified and directed.
75 mm thick PCC type C-2 1:3:6, (using 40 mm graded crushed stone aggregate) as in sub base for receiving floor finishes finished even and fair complete all as specified and directed.
25 mm thick PCC type B-1 (using 20 mm graded crushed stone aggregate) as in sub base for laying floor finishes complete all as specified and directed.
Coloured Chequered tiles lacquer finish of size 30 cm x 30 cm x 20-25 mm thick, set jointed and pointed in neat cement slurry as in path with white cement and pigment etc complete all as specified and directed.
200 mm dia reinforced concrete pipes, class NP-2 laid and jointed complete with collars complete all specified and directed.
PCC type B-1 (1:2:4) (using 20 mm graded cushed stone aggregate) as in coping, benching, lintel bands and cutting hole in bricks the like including form work complete all as specified and directed.
Precasted RCC jallies 45 to 50 mm thick (measured solid) including all mouldings but excluding frames conforming to type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
Cutting holes in brick wall exceeding half brick but not exceeding one brick built in cement mortar or cement lime morter and stone wall built in lime morter and making good with dismantled portion in CM 1:3 or cement concrete 1:2:4 type B-0 complete all as specifed and directed.
Collapsible gate, consisting of channel pickets, pivoted flat bars. Top and bottom runners brass handles etc. as specified, erected in position and securing runners with hold fasts and brackets complete all as specified and directed.
1.25 mm thick laths Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; gear operated type with bevel gear box and crank handle complete all as specified and directed.
Preparing new or old plastered surfaces of wall surfaces and applying two coats of cement base paint over coat of prime complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in level course on floor etc complete all as specified and directed.
Vitrified ceramic tiles (Double charge), area of each tile not exceeding 0.36 sqm, 10 mm thick (square or rectangular) of superior quality as in floor surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
Backing coat of cement mortar 10 mm thick in 1:3 to receive tiles in vertical surfaces complete all as specified and directed.
All as per ser item No 179 but skairting/dado complete all as specified and directed.
MS Steel screw bolts (machine made) with hexagonal or square heads at one and screwed at other or screwed both ends each screwed and to be fitted with washer and one hexagonal or square nut, exceeding 16 to 20 mm dia of neck and not exceeding 15 cm long complete all as specified and directed.
MS Steel screw bolts (machine made) with hexagonal or square heads at one and screwed at other or screwed both ends each screwed and to be fitted with washer and one hexagonal or square nut, exceeding 12 to 20 mm dia and exceeding 15 cm not exceeding 30 cm long complete all as specified and directed.
Providing 50 mm thick cement concrete (1:3:6) type D-2 (using 20 mm graded aggregate) as in sub base for hard paved area complete all as specified and directed.
Point wiring for one light/fan/bell point controlled by one switch using 1.5 Sqmm FRLS copper conductor cables (multistranded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with Modular metal flush boxes thickness (1.25 mm) & PVC back plate for mounting modular type in adequate module of switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts copper conductor cable 1.5 Sqmm as earth wire stranded and conected to earth dolly complete all as specified and directed.
All as per ser item No 184 but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 184 but for 1 Pin 15 Amps socket outlet independent with cable 2.5 Sqmm including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
All as per ser item No 184 but for 3 pin 6 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire and connected to earth dolly complete all as specified and directed.
Switch Piano flush type 6 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed.
Switch Piano flush type 16 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed.
Socket combined 2-in-1, 3 Pin 6 Amps (Modular Type) with outer strip complete all as specified and directed.
Socket combined 2-in-1, 3 Pin 6 & 16 Amps (Modular Type) with outer strip complete all as specified and directed.
Ceiling rose surface bakelite 3 terminals complete all as specified and directed. Make : Legrand/Anchor/Havells.
Exhaust fan Ventil Air - DB 300 mm including louver & making hole for Exhaust fan works complete all as specified and directed. Make - Havells/Polycab/Bajaj.
Hanging Ceiling fan 1200 mm sweep complete set without regulator including connecting to ceiling rose with twin twisted flexible cooper cable and provisioning of suitable fan hook/ down rod including all accessories as per site requirement Model :- XP-390 complete all as specified and directed. Make :- Havells or equivalent to Bajaj/ Philips/Crompton.
Electronic step type fan regulator 120 watt 230 volts 50 C/S deluxe modular type complete all as spcified and directed.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
MCB Single Pole, 230 Volt, Raiting 6 to 32 Amps complete all as specified and directed. Cat Part No : 811015, Make : Indoasian
MCB Single Pole and Neutral, 230 Volt, Raiting 35 to 63 Amps complete all as specified and directed. Cat Part No : 811037, Make : Indoasian
New E-Lite LED Curve, with wide angle profile. High lumen batten with efficacy of 100 lumens in 20 W LED 6000K Make- Havells Cat Part No LHEXBXPNIN1W020 or equivalent to Polycab/ HPL/Bajaj complete all as specified and directed by Engineer-in-Charge.
Replacement of LED bulk head luminaire, 10 W (ENDURA RUGBY) Cat Part No. LHEOAOP7UZ6W010 230 Volts wall/surface mounted complete with with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
36W LED edge-lit luminaire suitable for armstrong/rigit ceiling complete with separate electronic driver complete all as specified and directed. Cat Part No - LHECDIL6PP1W036 Make : Havells
LED Street light 30W including angle arms (Bracket) with 25 mm dia GI pipe complete all as specified and directed by Engineer-in-Charge. Make - Wipro Product Code- D923065 or equivalent to Havells/HPL/Bajaj
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2 x 6 Sqmm FRLS in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 1 x 4 Sqmm FRLS as earth lead complete all as specified and directed. Including taking down old sub main wire.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.30 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead 4 mm dia by means of bolts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and indicated and testing on completion including excavation earth work drilling holes for electrode PCC pit & cover, funnel, water pipe lugs GI pipe medium grade protection pipe for earth lead up to DBs complete all as specified and directed.
Taking down carefully, copper/aluminum point wiring (light, fan, socket or power/LED Light fittings) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed. Keeping the LED lights in safe custody.
20 Watt E-Lite LED PRIDE PLUS NEO, ultra slim square profile LED Lighting fixture with extruded polycarbonate, enviornmental friendly, energy efficient ready to use pack complete all as specified and directed by Engineer-in-Charge. Make- Havells Cat Part No LHEXACP7IN1W020 or equivalent to Polycab/HPL/Bajaj
1 x 40 W Candle E14 wall mounted fancy light, SS finish fixture with opal glass diffuser suitable for 40W incandescent candle lamp complete all as specified and directed. Cat Part No : LHJE03104499 Make : Havells or equivalent to Philips/Bajaj/C&S
Replacement Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-I angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed.
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 4 core size complete all as specified and directed. Make - KEI, Finolex & Polycab. Note : Earth work and other connected work shall be measured & paid sperately.
Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and directed. Note : for payment purpose punned thickness shall be measured
Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed.
GI tubing light grade 25 mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and directed.
Point wiring for one light/fan point controlled by one switch using 1.5 Sqmm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with sunk Cl/Pressed steel terminal boxes with 3 mm thick laminated sheet cover including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sqmm as earth wire stranded and conected to earth dolly complete all as specified and directed.
All as per ser item No 214 but for 3 Pin 15 Amps socket outlet independent with cable 4.0 Sqmm including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
Switch piano flush type 5 Amps single pole one way complete all as specified and directed. Make : Anchor/kinjal
Switch socket combination 2-in-1, 3 pin 5 & 15 Amps flush type complete all as specified and directed. Make : Anchor/kinjal
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 04 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, Make- Havells/Legrand/L&T, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately. Make: Havells Cat Part No-DCDKSHODCW08 or equevalent C&S/Legrand
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 10 Sqmm x 2 core size complete all as specified and directed. Make - KEI, Finolex & Polycab. Note : Earth work and other connected work shall be measured & paid sperately.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable in and including not less than 2.00 mm thick 20 mm dia and over Non metallic Rigid PVC surface/Concealed Conduit (ISI marked) with and all accessories 1.5 mm thick mild steel terminal boxes concealed on walls, painting the same inside and out side with one coat of black bitumen paint with 3 mm thick hylam brand bakelite sheet cover for fixing of piano switches/sockets/regulator etc along with PVC insulated and unsheathed FRLS 1.00 sqmm multi stranded copper conductor cable (green color) as earth lead & connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification complete all as specified and directed by Engr- in-Charge. Make - KEI or equivalent make in polycab/finolex
All as per ser Item No 220 here-in-before but for one 3 pin 5 Amp socket outlet point controlled by one push button on same board complete all as specified and directed. Make- Anchor or equivalent make in polycab/Havells
All as per ser Item No 220 here-in-before but for one 3 pin 5 Amp socket outlet point controlled by one push button on independent board, cable 2.5 Sqmm including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
All as per ser Item No 220 here-in-before but for one 3 Pin 15 Amps socket outlet independent with cable 4.0 Sqmm including copper PVC insulated PVC unsheathed 2.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5A, 240 Volt in repair complete all as specified and directed.
Switch socket combination 5 Amps 2-in-1, 5 Pin flush type, 230 volts in repair complete all as specified and directed.
Single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator of make wipro/equivalent in Havells /Bajaj complete all as specified and directed.
Replacement of New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 5 W complete all as specified and directed by Engineer-in-Charge. Make - Havells, Cat Part No LHEXBXPNIN1W005 or equivalent to Polycab/ HPL/Bajaj
Replacement of Maple 40 W gate light post top for 360 degree indirect light with IP 65 protection resistant to impact and corrosion glare-free and better uniformity complete all as specified and directed by Engineer-in-Charge. Cat Part No : LPTO-40-CDL, Make - Crompton or equivalent to Polycab/HPL/Bajaj
Replacement of wall mounting, SS finish fixture with opal PC diffuser suitable for 40W incandescent including 7W LED candle lamp complete all as specified and directed by Engr-in-Charge. Cat Part No : LHJE01104499, Make - Havells or equivalent to Polycab/HPL/Bajaj
Re-fixing only Ceiling fan/Exhaust fan/Energy Meter and cable of existing fans complete all as specified and directed by Engineer-in-Charge.
GI tubing light grade 40 mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc. for holdining of GI pipe alongwith poles complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed.
paras ram pachiala
KALSOTRA CONSTRUCTION CO
RAJ MOHD
s l sharma and sons
RAMAN CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .