Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC AT AND P O DAKRA P S KHALARI DIST RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC The L1 bidder is techno-commercially qualified. The quoted rate has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹7.5 L+₹6,884.83 (0.93%)Rejected-Finance 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | - | Rejected-Technical Technically disqualified. |
| Sl No | Description | Qty | Unit | M/S KUMAR ENTERPRISES L2 | M/S DHARMENDRA KUMAR SINGH L1 |
|---|---|---|---|---|---|
| 1.00 | Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required | 180 | Kg | 160.23 ₹28,841.4 | 158.76 ₹28,576.8 Lowest |
| 2.00 | Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required | 6 | Set | 245.25 ₹1,471.5 | 243 ₹1,458 Lowest |
| 3.00 | Dismanting of fabricated lighting tower | 7 | Nos | 4,343.65 ₹30,405.55 | 4,303.8 ₹30,126.6 Lowest |
| 4.00 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 16.00 Metre and upto 20.00 Metre (Fabricated Tower). | 7 | Nos | 8,787.58 ₹61,513.06 | 8,706.96 ₹60,948.72 Lowest |
| 5.00 | Dismantling of fixed type lighting tower with control panel and other fittings | 1 | Nos | 11,948.58 ₹11,948.58 | 11,838.96 ₹11,838.96 Lowest |
| 6.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. | 31.2 | cum | 205.41 ₹6,408.79 | 203.53 ₹6,350.14 Lowest |
| 7.00 | Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation etc including form work etc as required. | 13.2 | Cum | 6,021.87 ₹79,488.68 | 5,966.62 ₹78,759.38 Lowest |
| 8.00 | Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding in all complete with mild steel and medium tensile steel bars | 95 | Kg | 81.97 ₹7,787.15 | 81.22 ₹7,715.9 Lowest |
| 9.00 | Providing and fixing of foundation bolt, G.I 15mm x 24 mm | 8 | Nos | 1,375.38 ₹11,003.04 | 1,362.77 ₹10,902.16 Lowest |
| 10.00 | Cutting of MS plate for base flange making with making of holes etc. | 3,935 | mm | 0.63 ₹2,479.05 Lowest | 0.63 ₹2,479.05 Lowest |
Tender Value
₹8.1 L
EMD Value
₹10,200
Closing Date
3 Jun 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM NK
GM OFFICE, NK AREA
(A) Shifting of lighting towers, fixing of lighting arrestor, replacement of damaged GOAB Switch (B) Treatment of 46 Nos. earthpits (C) earth fault, power leakage from OHL, bush cutting, trimming of branches of trees, surface dressing Dakra OCP,
2025_CCL_336003_1
GM (NK)/EnM/e-NIT/2025-26/40
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Dakra OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹10,200
25 Aug 2025
23 May 2025
4 Jun 2025
24 May 2025
3 Jun 2025
24 May 2025
24 May 2025 - 30 May 2025
Amount
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required
Dismanting of fabricated lighting tower
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 16.00 Metre and upto 20.00 Metre (Fabricated Tower).
Dismantling of fixed type lighting tower with control panel and other fittings
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation etc including form work etc as required.
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding in all complete with mild steel and medium tensile steel bars
Providing and fixing of foundation bolt, G.I 15mm x 24 mm
Cutting of MS plate for base flange making with making of holes etc.
Erection of fix type lighting tower with control panel and other fitting
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtrs long etc etc. with charcoal/coke and salt as required. (For High Mast Tower)
Fixing of Flood light on Tower with connection etc as required.
Provision of following materials for fixing of Lighting Arrestor. Copper Arrestor: Thickness of rod 16mm, Height of rod 30 Inch, Top finger of Ball 50 mm dia x 4 inch long
Earthing with G.I. earth pipe 4.5 Metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal / coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
GOAB Switch 11kV/800 Amp (Including fixing charge)
Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 (1 Cement: 4 coarse sand). For 46 Nos. earth pit.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required for 46 nos. Earth pit.
Earth pit treatment and repairing with charcoal, salt, GI nut bolt for 46 Nos. earth pit.
Cleaning jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. Two times.
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m: All kinds of soil.
Total impact of GST for the purpose of CTC
M/S KUMAR ENTERPRISES (BID ID -1156046)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .