| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.0 L+₹1.2 L (8.16%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-AOC Being L2 |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
31 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE (I) (AF)/SHL/ OF 2021-22 PROVN OF EXTERNAL SERVICES FOR NFS INFRASTRUCTURE AT 792 SU, UNDER GE (I) (AF) SHILLONG
2021_MES_457166_1
8030/21/SHL/2021/22
Open Tender
Civil Works
Item Rate
180 days
SHILLONG
For Enlisted Contractors Class E Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) SHILLONG
₹27,000
Yes
18 Aug 2021
5 Jul 2021
2 Aug 2021
5 Jul 2021
31 Jul 2021
19 Jul 2021
5 Jul 2021 - 12 Jul 2021
60 days
Amount
B/R ITEMS Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loosed soil complete all as specified and directed.
Excavation over areas n. exc 1.5 mtr deep in soft/loose soil and getting out complete all as specified and directed
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and getting out in soft/loose soil complete all as directed. (8.25+10+24+20+72)
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick,complete, all as specified and directed. (4.75+6.00+10.62+10.5+6)
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point,complete, all as specified and directed . (5.75+24.00+8.00+13.38+9.5+66)
M & L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed. (6.98+12)
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. (1.18+12)
M&L for Plain Cement Concrete (PCC) 1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M & L for providing cement concrete 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains and benching including use and waste of formwork where necessary and finishing the exposed top surface of concrete even and smooth using extra cement complete all as specified and directed. (0.15+30)
M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in roof kerbs of mud stops, rounded or chamfered on edges and in lintels upto 1.5m clear span, steps, seismic and other similar bands copping/cills, bed block for embedding hold fast etc including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as directed . (4.8+0.20)
M & L providing precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces joint as directed and setting in CM 1:4 complete all as specified and directed. (Note :- Reinforcement shall be measured and paid for separately under respective items of the BOQ.)
M & L for precast cement concrete block masonry 1:3:6 Type C-1 using 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
M & L for Reinforced cement concrete M-25 (design mix) using graded stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5m clear span complete all as specified and directed.
M&L for pre-cast cement concrete block masonry 1:3:6 Type C-1 using 20mm graded stone aggregate with solid blocks, 10 cm thick and setting in cement mortar 1:4, complete all as specified and directed.
M & L for precast cement concrete block masonry 1:3:6 Type C-1 using 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
Supply only integral water proofing liquid complete all as directed.(0.5+0.6)
M & L for Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of curved formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, In opening complete all as per specifications and drawings as applicable to item 08095 given in SSR Part – II (2010).
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II.
S & F butt hinges, medium weight, colled rolled mild steel & ISI marked complete all as specified and directed for following sizes:-
100mm long.
S & F 100mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F 100mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
S & F chromium plated brass tubular towel rail 20 mm dia, D type 60 cm long between flanges complete all as directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers & binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F mild steel work in tubular trusses, purlins and posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed.
S & F for pre-painted galvalume aluminum zinc coating GI based trapizoidal profile steel sheet 0.50mm thick (overall) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instructions complete all as specified and directed.
M & L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as directed.
M & L for screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:4, for laying floor finishes complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for 60mm thick PVC moulded precast interlocking paving blocks factory casted using grey cement and pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 350 Kg/ Sqcm laid over and including 25 to 30mm thick layer of sand cushioning including filling the interstices with & including sand and interstices on edges filled with PCC 1:2:4 type B-1 finished even and smooth without using extra cement complete all as directed.
M & L for 75mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick masonry/ concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:3 on stone masonry surfaces or on other than fair faces of brick masonry surfaces mixed with WPC and finished even and smooth without using extra cement complete all as specified and directed. (Note :- Supply only WPC shall be measured and paid separately)
M & L for rendering 20mm thick in two layers on fair faces of brick masonry/concrete surfaces, first layer 15mm thick in cement mortar 1:6 and second layer 5mm thick in cement mortar 1:4 mixed WPC, finished even and smooth without using extra cement complete all as specified and directed. (Note :- Supply only WPC shall be measured and paid separately)
M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all specified and as directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1mm thick wall care putty complete all as directed. (Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.)
Material and labour for preparation of newly plastered surfaces of wall, applying a coat of 1mm thick wall care putty and applying two coats of weather proof acrylic paint over one coat of exterior grade acrylic primer complete all as specified and directed. Make-Apex Ultima of Asian, weather shield MAX of ICI/Dulux, weather coat long life of Beger, Acroguard 3X of Acro paint.
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed for following sizes:-
75mm bore
110mm bore
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed for following sizes:-
110mm bore
S & F PVC (SWR) bend of any radius with oval access door complete all as specified for following sizes:-
110mm bore
S & F PVC (SWR) 110mm branch piece, single (single Y) equal or unequal with oval access door complete all as specified and directed.
S & F PVC (SWR) vent cowl for 110 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) WC connector with lip ring for 110 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) floor trap 75mm dia outlet plain with Stainless steel grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as directed.
S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed for following sizes:-
15mm bore.
20mm bore.
M & L for provision and construction of Reinforced cement concrete (RCC) septic tank for 50 user all as per drawing No. AF/SHL/WD/01/ 2019, sheet No. 1/1 complete all as specified and directed. {Notes : Irrespective of whatsoever shown in drawing, depth of fluid level from bottom of RCC cover slab of septic tank shall be 1500mm. Contractor's quoted rate shall deemed to include for above stipulation. Any variation in depth from 1500mm (as stated above) shall be regularised through Deviation order as per Condition 62 of IAFW-2249.}
M & L for provision and construction of Soakage wells, of size 1.6m diameter & 3.0m depth all as per drawing No AF/TD/STRU/236 sheet No. 1/2 & 2/2 complete all as specified and directed.
S & F reinforced concrete pipes, class NP-2, laid and jointed complete with collars and tested complete all as specified and directed for following bore pipes:-
150mm bore pipe
M & L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in bedding to SGSW/NP-2 drain pipe including packing under and haunching against the sides of the pipes after they are laid and tested complete all as specified and directed for following bore (internal dia) pipes:-
150mm bore pipe
S & F chromium plated push tap screwed for iron pipe and fixed to urinal complete all as specified and directed.
S & F 15mm bore bib tap cast copper alloy fancy type chromium plated long body with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15mm bore stop valve cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F Pillar tap 15mm dia fancy type with capstan head chromium plated screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nut complete all as specified and directed.
S & F for gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia complete all as specified and directed.
S & F PVC connection pipe 15mm dia with PTMT nuts of length 600mm complete all as specified and directed.
S & F urinal spreader cost copper alloy, chromium plated complete all as directed.
S & F vitreous China urinals Half stall type, Model Aquaseal N of Parryware, Cat Part No C-0578 (outlet) or equivalent model of Make of Cera/Johnson/Prayag of size 305x305x440mm, white providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with & including PTMT grating and union for dishcharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified and directed.
S & F 500 litres capacity rotational moulded HDPE water storage tank tripple layer (Cylinderical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F vitreous china wash basin, white, flat back, size 550 x 400 mm including one No PVC waste pipe 25 mm dia and 75 cm long with 32 mm dia connector, 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed complete including cutting for and pinning in ends of bracket or erecting stand complete all as directed.
S & F white Vitreous china wash down water closet pan (pedestal pattern) with integral S trap including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe and fixing bolts (excluding flushing cistern) etc complete all as specified and directed. (Product Code & Make :- Cat Part No CNS-WHT-WH-10 of JAQUAR or equivalent model of other makes listed in list of makes).
S & F chromium plated 32mm size bottle trap (with internal partition) with 300mm & 190mm long wall connection pipes & wall flange complete all as specified and directed. (Product Code & Make :- Cat Part No ALD-769L300x190 of JAQUAR or equivalent model of other makes listed in list of makes).
S&F PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S&F glass shelf 500 x 125mm with decorative and ornamental side supports and front lining of chromium plated fixed with screws and glass with as shelf supported over frames all as specified and all as directed. (Product Code & Make :- Cat Part No. BEA-45 of Make Prayag or equivalent model of other makes listed in list of makes).
E/M AND WATER SUPPLY ITEMS M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS including sunk type pressed steel terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite sheet top cover for mounting switches, sockets, regulators, bell push etc, including 1.5 Sq.mm multistranded copper conductor with green PVC FRLS-H insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. )
One light point/fan point/bell point controlled by one, one way switch.
M & L for point wiring complete for 15 Amps socket outlet on independent board with 4 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable drawn through and including PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS, including 4 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H green colour cable as earth continuity conductor to common earth & connecting to earth dolly. Notes : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces.
M & L for modular metal flush box for the following modules :-
4 Module
M & L for modular white cover plate with frame for the following modules :-
4 Module
S & F modular switch, 1 way 6A, 240 Volts, 1 module complete all as specified and directed.
S & F, modular socket outlet for two in one, three pin combined, 6 & 16 Amp, 240 Volts, 2 Module type complete all as specified & directed.
S & F ceiling rose, three terminal, PVC / poly carbonate isolated body, complete all as specified and directed.
Supply and fix baton integrated LED tube light batten fitting, 18 Watt 230 V, 50 Hz with with all standard fittings etc pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Model/Make : Cat Part No BCLSB 18WH for Baton integrated tube light fitting of make Bajaj or equivalent model of makes listed in List of makes}.
Supply and fix LED tube light fitting, baton integrated LED channel 10 Watt 230 V, 50 Hz with with all standard fittings etc pre-wired including LED tube, colour temperature neutral white and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Model/Make : Cat Part No BCLSB 10 NW of make Bajaj or equivalent model of makes listed in List makes}.
Supply, Installation, commissioning and testing of LED street light fitting of 45 Watts rating enclosed in high grade aluminum pressure die-cast housing with High efficiency polycarbonate UV stabilized cover suitably gasketed including high power LEDs, Ingress protection IP-65/66, operating voltage range 140 V - 270 V, 50 HZ, AC heat/thermal management compliance & system light efficacy of fitting should not less than 110 lumen/Watt, easily adjustable for different mounting pipes, luminaire safety compliance to IS-10322, dust and water proof cabinet, Effeciency of driver electronic not less than 90%, power factor of complete fitting not less than 0.95 and connecting complete all as specified & directed. {Model/Make:- NEXUS+ Series Cat Part No. LSTP-45-CDL of make Crompton or equivalent model of list of makes as per Particular specification).
S & F sheet metal enclosure double door DB SPN 4 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal enclosure vertical type double door DB TPN 4 way suitable to accomodate MCCB FP, 415 volts upto 160 Amps rating, protection class IP-54 IK-09 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted as per IEC 61439-3, with copper bus bar of 250 Amps capacity for each phase, with two neutralbars, two Earth bars and cable ties for cable managementall as specified and as approved by Engineer-in-Charge. {Model/Make : Cat Part No 5077 50 of make Legrand or equivalent model of makes listed in List makes}. (Note: MCCB & MCBs shall be measured and paid separately)
S & F MCB SP 6 to 32 Amps, 240 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed. (2+12)
S & F MCB SP 40 Amps, 240 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F MCCB four pole 100 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 16 KA at 415 V AC , 50 Hz
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS-H cable 1100 Volt grade with 4 Sqmm copper multistranded conductor drawn through and including PVC conduit 20mm bore concealed in walls/ceilings/roofs including 4 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: - (i) Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only. (ii) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces.
Supplying, Fixing/laying, jointing and testing and commissioning, LT under ground cables, 1100 Volts grade, XLPE insulated, armoured heavy duty electric cable with stranded aluminuim conductors, laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe complete all as specified and directed of following sizes:-
3.5 core 95 Sqmm Notes :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ against B/R items. (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M & L for brick protection for UG XLPE cable with sub class 'B' bricks, old size laid dry and flat abutting each other with gaps between adjacent brick 10mm with width equal to length of brick in trenches across the cable complete all as directed.
S & F 40mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239 omplete all as specified and directed. (Note : Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ against B/R items).
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 15mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
M & L for Earth continuity conductor of 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as directed.
Supply and laying 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches in new alignment for following outer dia pipes complete all as specified and directed :-
63 mm outer dia
32 mm outer dia
S & F PP-R Gate valves (brass insert) screwed both ends for PPR pipes and fixed for following outer dia pipes complete all as specified and directed :-
63 mm outer dia
32 mm outer dia
M & L for cutting existing 100mm bore cast iron pipe in position for insertion of new tee, branches etc. complete all as specified and directed. Note :- Excavation and earth work shall be measured and paid separately under respective items
M & L for construction of brick masonary valve pit of size 45cm x 45cm x 45cm (Internal dimension) one brick thick wall in cement mortar 1:4 and 100mm thick PCC 1:4:8 type D2 in foundation and 15mm thick plastering. Providing valve pit cover made of 3 mm thick MS sheet/plate welded with 40x40x6mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC 1:2:4 type B1, including two coat of anticorrosive paint over a coat of red oxide primer and necessary earth work in soft/loose soil complete all as specified and directed.
kapoor and co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .