Shri RK PARASHARI AGE(I) AF MEMAURA
Office -AGE(I) Air Force Stn Memaura
CERTAIN MISC B/R WORKS AT 505 SU AT AF STN MAMAURA.
2020_MES_399468_1
8164/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN MEMAURA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I AF MEMAURA
₹19,000
29 Jan 2021
30 Nov 2020
28 Dec 2020
30 Nov 2020
26 Dec 2020
14 Dec 2020
60 days
Amount
Cleaning of OH water tank upto 500 ltrs capacity including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc dewatering with tools/machines/ submirsible, sludge removal and rubbing with mineral acid/ bleaching powder and:anti bacterial spray with clorine water or KMNO4 (Potassium permanganate), after completion of cleaning writing letters of minimum 100 mm height each ("Cleaned on "Month" and "Year") with spray paint through appropriate stencil sheet cutting (white or black) on the tanks and removal of existing date and year marking if existed on the PVC tanks complete all as specified and directed.
Description all as per item No. 01 above but more than 500 ltrs upto and including 1000 ltrs capacity -ditto -
Supply and fixing of galvanised iron ghamela/tasla, round shaped, of dia not less than 585 mm and weight not not less than 2.85 kg each for fixing over the lids of PVC over head water tanks, fixed with MS bolts and nuts and washers by making holes, complete all as specified and directed. (Note:- Nuts, bolts and washers will be measured and paid seperately)
Supply and fixing of mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with four washers in each and three hexagonal or square nut, length of bolt exc 10cm and n.exc 15 cm long and diameter of neck 11 to 15 mm, fixed complete all as specified and directed.
Supply and fixing 15 mm bore tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floors of any length including taking down of old u/s tubes and removal from site complete all as specified and directed. Make : JINDAL/PRAKASH/TATA
Description all as per item No 5 above but for 20 mm dia
Laying only galvanised iron tubes 15mm bore with all new fittings fixed complete to walls and ceiling or laid in floors including taking down old u/s tubes complete all as specified and directed.
Description all as per item No 7 above but for 20 mm dia.
Supply and fixing in repair PVC ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for 15mm bore pipes all as specified and directed.Make : Symet Prayag
Description all as per item No 9 here-in-before but for 20mm bore pipe.
Roughening to surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0Kg of cement per sqm complete all as dierected.
M&L for 15mm thick screed bed in CM 1:4 in coarse sand mixed with water proofing compound as per manufacturer instruction , laying over green concrete or old roughened surfaces, finishing the surface even and smooth with out using extra cement , complete all as specified and directed. (WPC measured separately)
Supply only liquid water proofing compound, complete all as specified and directed.
M&L for applying a coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm on concrete or plastered surface to make the surfaces water proof complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and as directed.
M & L for hard core, broken bricks to gauge n exc 63 mm complete all as specified and directed.
M & L for 75mm thick PCC 1:5:10 type E-2, (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigment laid vover sand cushion complete all as specified and directed. (Note : sand cushion will be measured seperately)
M & L for providing, cement concrete 1:2:4 type B0, (using 12.5 mm graded stone aggregates) as in kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed.
M&L for cleaning /removal of old sealing compound, all foreign materials, dust etc from any type of joint and of any thickness and any depth of helipad / taxi track with a "Raker" and coir brush, Fine particles cleaning to the concrete faces shall be removed with the help of an Air Compressor and preparing it for refilling as per IRC 57-1974 and removing all retrieved materials to a distance not exceeding 500m or as directed bby Engineer-in-charge. M&L applying one coat of primer (Ralliprime 190 or pidi prime-A or Dr Fixit) as approved to the both sides of the cleaned joints with 20-25mm wide painter`s brush with light pressure to penetrate the primer into the pores of concrete or with spray gun machine. Allow it (Ralliprime-190 or Pidi prime-A or Dr Fixit) to dry for 10 minutes to 1hour depending on ambient conditions, care should be taken to avoid ponding of primer in base of joint, if it left unsealed for longer than 4 hour during the same working day repriming should be done. After priming, back up material (closed cell polyethylene Rod/Sheet) shall be put in the joint which should be 25% more in the diameter that the actual joint size Soon after the primer is applied and back up material the sides of the joints are to be covered with 10-15cm wide self adhesive paper strips so that spill over sealant can be easily removed. Finally polyurethane joint sealant (confirming to BS 5212 of make Rallithane-862 or Pidiseal PS 43 of Dr Fixit) components to be mixed in required proportion as per manufacturers instruction and poured into the joint opening in such a manner that the material does not spill over the exposed surfaces of the concrete. And tooling the applied sealent to maintain the recess and to give aesthetics. Spill over material if any, shall be scraped off, complete for the joint of average size 30x20mm
All as per item No 21 above here-in-before but for size of joint 45x30mm
All as per item No 21 above here-in-before but for size of joint 40x20mm
M & L for providing and laying 1.5 mm thick thermoplastic road marking paint white/yellow colour in uniform thickness with glass beads as per clause No 803 of MORTH specification incl cleaning of surface, heating the material within specified temperature limitas marking with all arrangement required for proper completion of work all as directed.
Disconnecting existing OH tanks, upto 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
M/S ALOK SRIVASTAVA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .