Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC RANGAPAHAR RAILWAY CROSSING GATE NO 1 DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹33.4 L+₹2.4 L (7.69%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹34.0 L+₹2.9 L (9.50%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹34.0 L+₹3.0 L (9.72%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹34.2 L+₹3.2 L (10.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 869 EWS
GE 869 EWS PIN-913869 C/O 99 APO
COMPREHENSIVE MAINT TO BLDGS OF GROUP II UNITS LOC AT INF BN TEMP LOC IFSU ARIVIDAM COMPLEX CENTRAL SECTOR RSA AND R O FLT NON TECH ASSETS AT LEIMAKHONG MIL STN
2024_MES_651867_1
8585/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹60,000
21 Jun 2024
1 May 2024
23 May 2024
1 May 2024
22 May 2024
15 May 2024
Amount
Schedule 'A'
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed. Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account.
Supply only intergral water proofing compound complete all as specified and directed
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5mm thick on fair face of brick work or concrete surface wall or ceiling in CM 1:3 finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of surfaces plastered or unplastered new surface on wall and applying two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of surfaces plastered or unplastered new surface on ceiling and applying three coats of white washing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick thickness below or above ground level complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and includig 15 mm thick screed bed in CM 1:4 complete all as specified and directed
M&L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in levelled course finish even and fair for tile finishes complete all as specified and directed by Engr in Charge.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engr in Charge
M & L for Glazed Coloured Ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick set and joint in neat cement slury and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:4 as backing coat to receive tiles complete all as specified and directed.
M & L for Non skid coloured ceramic tiles 7 to 8mm thick of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including rendering 10 mm thick on fair faces of brick work in CM (1:4) for receving vertical dado tiling complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each including easing and adjusting and also refixing builder hardware as required including renewal of unserviceable screw and necessarry materials refixing shutter in same opening complete all as specifeid and directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and as directed.
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and as directed.
S&F 75mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm long alumiunium handles cast type anodised complete all as specified and directed.
S&F 50mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M&L for 2nd class hard wood plain fillets, square, rectangular or triangular in section, sectional area exc 3 Sqcm & n. exc 6 sqcm clean sawn, secured with nails or brads complete all as specified and directed.
Dismantling of framed timper scantling 40 sq .cm and over in section,in any position complete all as specified and directed.
Ditto all as per item No 29 here-in-above but in fillets in framed work under 40 sq.cm in section complete all as specified and directed
M&L for second class clean sawn hard wood in scantling wrought, timber framed & fixed complete all as specified and directed.
Preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and directed
S&F 18/19 mm thick block boards, grade 1 quality, exterior with decorative face veneer on both faces grade, fixed with screws to timber frame work complete all as specified and directed
S&F 2nd class HW weather boarding, clean sawn, plainl 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed.
Hacking out old brocken glass (any thickness, size,quality or description) from wooden frames or steel frame, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for MS work as in framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sucnk) forming holes with any attachement Fe 410W (Gde-E-250) Quality A complete all as specified.
S&F rolled mild steel Fe-410w (Gde-E-250) quality 'A' Roof trusses (framed) , trussed, purlins, crane gantries , rails and fastening and havy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified.
All as per item No 42 here-in-above but fixing only complete all as specified and directed (Note :-serviceable Roof trusses (framed) , trussed, purlins, crane gantries, etc obtained from under relavant items)
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair water closet (Squating pattern) of vitreous china squatting pan of "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) incl connection to trap and flushing pipe and anti syphon pipe etc complete incl trap set in and incl concrete bedding complete all as specified and as directed
S&F in repair, light coloured Vitreous china wash basin, white oval shape, size 550 x 400 mm excl taps, waste chain and plug and porcelain stopper but incl brackets, waste pipe & CP waste coupling complete all as specified and as directed.
S&F in repairs Pillar taps, 15mm dia cast copper alloy, with capstan heads, chromium plated, but fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F PVC (SWR) floor trap with grating with incl jointing to waste pipe fixed in cement concerete (1:2:4) Type B1 diameter of outlet pipe 75mm complete all as specified and directed.
S&F in repair PVC connection 15x600mm long with PTMT nuts & bolts complete all as specified and directed.
S & F in repairs bore bib taps, ISI marked cast copper alloy, chromium plated fancy type screwed down, screwed for iron pipe or for brass ferule for 15 mm bore dia of pipe complete all as specified and directed.
S&F in repair fancy type Chromium plated with long shank and cup (concealed type) stop valve cost copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore complete all as specified and as directed.
S&F in repairs brass chromium plated shower roses 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union any colour for fixing with 15mm pipe complete all as specified and directed.
S&F in repairs brass chromium plated, 600mm long between flanges tubular towel rail , 20mm dia, D type. fixed with and including chromium plated brass screws and wooden plastic cleats, complete all as specified and directed.
S&F as in replacement stainless steel plate rack of size 24" x 36" x 10" complete all as specidfied and directed.
S & F in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
S & F in repairs fancy type Harrison rails, andodised aluminium alloy with fixing brackets, stops, rollers etc, of 20mm dia for window and doors with curtain rings and decorative doom holders fixed to wall with screw complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coveringscomplete all as specified and directed
S&F Pre-Painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified.
S&F Pre-Painted galvantume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified.
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'J' type hook bolt and washer or self tapping screws in roof, wall etc.with grade of zinc coating 275 complete all as specified.
S&F 0.63mm thick, plain galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed
M&L for preparation of new zinc (or galvanised) surfaces to receive painting including washing and cleaning by coating with mordant solution including washing and cleaning and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation oards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 25 x25 x0.35mm and main/cross tee of size 24 x38 x0.70mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed.
Taking down copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors etc complete all as specified and directed.
Material and labour for point wiring concealed type in existing concealed PVC conduit with 2 single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable with using new sunken type Pre - coated GI sheet pressed steel box including modular frame with cover plate for mounting modular switch socket etc incl all accessories and using single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. One light point controlled by one/way switch complete all as specified and directed.
One ceiling/exhaust fan point controlled by one way switch
One socket outlet 5 Amps 3 pin on same board with other switch
One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm size complete all as specified and directed
All as per item No. 68 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
All as per item No. 68 here-in-above but with cable size 4 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 4 Sqmm complete all as specified and directed.
Material and labour for point wiring concealed type with 2 single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable in concealed PVC conduit (medium grade) of 20mm dia all as specified and directed with using new sunken type Pre - coated GI sheet pressed steel box including modular frame and cover plate for mounting modular switches, sockets and fan regulators etc incl all accessories and using one single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. One light point controlled by one/way switch complete all as specified and directed
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 3 pin on same board with other switch
One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm size complete all as specified and directed
One bell point controlled by one way switches complete all as specified and directed.
All as per item No.74 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
All as per item No.74 here-in-above but with cable size 4 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 4 Sqmm complete all as specified and directed.
M&L for point wiring with two single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable and incl PVC casing and capping of suitable size fixed on surface all as directed with using new sunken type precoated GI/ pressed steel box/terminal boxes including modular frame and plate for mounting fittings/junction boxes incl all accessories and using one single core 1.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable as in earth wire connected to commen earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii) Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ One light point controlled by one one/way switch
One ceiling/exhaust fan point controlled by one, one way switch
One socket outlet 5 Amps 3 pin on same board with other switch
One socket outlet 5 Amps 3 pin on independent board with cable of 1.5 sqmm size complete all as specified and directed
One light point controlled by two way switches complete all as specified and directed
One bell point controlled by one way switches complete all as specified and directed.
All as per item No.81 here-in-above but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
All as per item No.81 here-in-above but with cable size 4 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand PVC insulated copper earth continuity conductor of size 4 Sqmm complete all as specified and directed.
S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed.
S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed.
S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed.
S&F modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
S&F Bell push switch Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed
S&F Modular step type regulator 120W, 2 module ,heavy duty, 240 volts complete all as specified and directed
S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type including one lamp complete all as specified and directed.
S&F in repair for submain wiring with single core 6.0 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 6.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed. (Note : Two run of single core cable and one run earth wire will be measured as one length)
S&F in repair for submain wiring with single core 4.0 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed. (Note : Two run of single core cable and one run earth wire will be measured as one length)
S&F in repair Concealed Galvanised (GI) metal flush Boxes Modular 3 module concealed including frame, cover plate and making the disturbed surface good by using white cement complete all as specified and directed.
S&F in repair Concealed Galvanised (GI) metal flush Boxes Modular 4 module concealed including frame, cover plate and making the disturbed surface good by using white cement complete all as specified and directed.
S&F in repair Concealed Galvanised (GI) metal flush Boxes Modular 6 module concealed including frame, cover plate and making the disturbed surface good by using white cement complete all as specified and directed.
Supply and fix in repair socket outlet, 3 pin, flush type, 5 Amps, complete all as specified and as directed.
Supply and fix in repair socket outlet, 3 pin, flush type, 15 Amps, complete all as specified and as directed.
S & F in repair 15 Amps Switch flush type complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt complete all as specified and directed
S&F in repair switch socket combination 3 pin 16 Amp flush type complete all as specified and directed
S&F in repair switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed
S & F in repair switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed
S&F in repair modular switch piano, 6 Amps, single pole, one way complete all as specified and directed.
S&F in repair modular switch piano, 16 Amps, single pole, one way complete all as specified and directed.
S & F in repair modular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed
S & F in repair modular bell push way 6 Amps 1 module 240 Volts complete all as specified and directed
S & F in repair modular socket outlet 6Amp 3 pin 2 module 240 Volts complete all as specified and directed
S & F in repair modular socket outlet 6/16 Amp 5 pin 2 module 240 Volts complete all as specified and directed
S&F in repair Modular step type regulator 120W, 2 module ,heavy duty, 240 volts complete all as specified and directed
S&F in repair Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.
S&F in repair bell Buzzer , Ding Dong Type , AC 230 Volts single pole complete all as specified and directed.
S&F in repair Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F in repair of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator flush type, 230 Volt, 5 speed control complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type white/warm with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repair sheet metal enclosure DB, TPN, IP 43 protection, double door, 240 volts, Vertical Type 4 way with copper bus bars suitable for mounting MCBs of minimum 415 Amps rating complete all as specified and directed.
S&F in repair sheet metal enclosure for MCB’s distribution board, 240 Volts, 12 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door Type for breaking capacity 10 KA complete all as specified and directed.
S&F in repair sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door Type for breaking capacity 10 KA complete all as specified and directed.
S&F in repair sheet metal enclosure for MCB’s distribution board, 240 Volts, 4 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door Type verticle for breaking capacity 10 KA complete all as specified and directed.
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps 10 KA complete all as specified and directed.
S&F in repair MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in repair MCB single pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in replacement of MCB single pole and neutral 40 to 63 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in replacement of MCB/ Isolator single pole and neutral 100 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in replacement MCB Isolator four pole 80 Amp 415 Volts complete all as specified and directed.
S&F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
All as per serial item No.132 here-in-above but for size 175x100x50 mm deep complete all as specified and directed.
All as per serial item No.132 here-in-above but for size 200x150x50 mm deep complete all as specified and directed.
All as per serial item No.132 here-in-above but for size 250x200x50 mm deep complete all as specified and directed.
All as per serial item No.132 here-in-above but for size 350x200x50 mm deep complete all as specified and directed.
S&F in repair single phase electronic meters temper proof LCD display with polycarbonate cover 230 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
S&F in repair of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories including such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed
S & F in repair LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type white/ warm with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as directed by Engr-in-charge.
S & F in repair LED lights fitting 1x 20W, 220V, AC decorative box type white/ warm with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.
S & F in repair LED lights fitting 1x 20W, 220V, AC LED Batten with Opal Diffuser, IP20, Inbuilt Motion Sensor based Auto Dim/Brightness decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.
S&F in repair LED builidng security light fitting 25 Watt 230 V, AC out door type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S & F in repair round/ square shape 6 watt 220 volt AC resessed/ surface mounted white/ warm type with high effciency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair round/ square shape 12 watt 220 volt AC resessed/ surface mounted white/ warm type with high effciency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED bulb Lamp 09/10 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.
Taking down and dismantling of storage type water geysers of 25 ltrs capacity any type any make, any model, from its existing location, transportation to work shop for repairs and transportation back and reinstallation of geyser as per technical instructions and as directed by engr-in-charge and including the following:- (a) Dismantling complete geyser and carrying out complete overhauling i.e; disconnecting electric supply and opening the heating plate, inner assembly, descaling complete assembly including heating element or otherwise. Replacement of defective heating element inlet and outlet tubes and refixing the assembly with gasket of good quality and tightening the nuts properly, reassembling geyser with all safety devices as specified in technical instructions and as directed by Engineer -in- Charge complete. Notes:- (i) Spare parts, safety devices with its required accessories shall be measured and paid seperately .
All as per serial item No. 147 here-in-above but for capacity 50 ltrs complete all as specified and directed.
Supply only following spare parts of geysers 50/25 Ltrs capacity (149.01) Heating element 1.5/2 KW suitable for operation on 230V AC 50Hz
(149.02) Thermostat 40 to 90 degree centigrade varying capactiy for 25/50 Ltrs capacity Geyser.
(149.03) stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.
(149.04) Indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.
(149.05) Syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.
(149.06) Geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.
S&F in repair 15 Amp plug top complete all as specified and directed.
S&F in repair earth industrial plug top for socket for industrial socket metal glad suitable for 16 Amps metal glad MCB DB complete all as specified and directed.
S&F in repair industrial socket metal glad suitable for 16 Amps 240 volts metal glad MCB DB complete all as specified and directed.
S&F in repair 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances complete all as specified and directed.
S&F in repair 23/.0076 sqmm 2 core flexible copper cable for maintenance of light/ fan etc complete all as specified and directed.
M&L for attending complaint of ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/dismantling/loose connection etc complete all as specified and directed
S&F in repair of BLDC fan driver suitable for any make , type & sweep BLDC ceiling fan complete all as specified and directed.
S & F in repair capacitor of 2.5 MFD of ISI marked complete all as specified and directed.
M&L in repair of rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling including taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M & L in repair of rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling including taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M & L in repair of rewinding Exhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling including taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M&L in repair of fan bearing 6201/6202 of ceiling fan of any capacity any size complete all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.
M&L in repair of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size complete all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.
S&F in repair exahust fan louvers of 300mm sweep with locking nut complete all as specified and directed
M&L in repair for repairing/servecing/welding/brazzing/reinsulating and cladding of hot water tank all as specified and directed.
S&F in repair collecter glass (toughned) of solar water heater complete all as specified and directed
S&F in repair CPVC pipe 1" dia including elbow, union, socket,bend etc complete all as specified and directed
S&F in repair CPVC pipe 1.5" dia including elbow, union, socket,bend etc complete all as specified and directed
S&F in repair CPVC Non Return Valve 1" dia all as specified and directed.
S&F in repair CPVC Non Return Valve1.5" dia all as specified and directed.
S&F in repair CPVC union 1" dia all as specified and directed.
S&F in repair CPVC union 1.5" dia all as specified and directed.
M/s Nongmaithem Construction
M/S Apple constructions
Manipur Steel Industries(INDIA)
Ms SATISH CHAND AGARWAL
M/S PRADEEP CONSTRUCTION
MANI PRASAD GUPTA
M/S MANGANG RENOVATIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .