Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 528 PREETI NAGAR 125001 | HISAR | HARYANA | 125001 | Admitted-Finance |
Tender Value
₹2.0 L
EMD Value
₹4,000
Closing Date
10 Mar 2021, 4:00 pmClosed
XEN/CMD-I, RGTPP, HISAR
XEN/CMD-I, RGTPP, HISAR
Construction of Centralized Control Room for CCTV Surveillance Systems installed on the periphery wall of RGTPP, Khedar
2021_HBC_158254_1
NIT No.30/XEN/ CMD-I/RGTPP/2020-2021 dt01.02.2021
Open Tender
Civil Works
Works
45 days
RGTPP HISAR
AS PER PQR AND NIT DOCUMENTS
2 documents required · 2 mandatory
₹1,180
Yes
₹4,000
Yes
30 Apr 2021
1 Feb 2021
13 Mar 2021
1 Feb 2021
10 Mar 2021
1 Feb 2021
Amount
Dismantling reinforced cement concrete with cleaning and straightening and cutting of bars if required
Earth work in excavation in foundations, trenches etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres.
Steel reinforcement TMT bars FE-500 /FE-500D grade or more for RCC work ,where no included in the complete rate of RCC including straighting,bending,binding,wastage,overlap,welded joints,spacer bar,chairs,stays,hanger and annealed steel wire etc. and placing in position complete in all respects for all heights/depths/storeys/basements etc.
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in Position, complete in all respects.
Laying of first class ash brick laid in cement sand mortar 1:4 in the first storey upto 4 meter above the plinth level including loading, unloading, stacking, carriage within lead of 4 km ( fly ash brick to be provided by HPGCL
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering, laid in position complete in all respects.
12 mm thick cement plaster 1:5
15 mm thick Cement Plaster 1:4 on the rough side of single or half brick wall
Wrought iron and mild steel (using angles, flats, square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors open able or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position.
Applying priming coat with metal primeron new steel or iron work includingpreparation of surface.
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or astered or concrete surfaces to give an even Shade
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work.
Providing two coats of exterior acrylic emulsion paint 1st quality
Base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling.
Precast terrazzo tiles of 20 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and ladings including rubbing and polishing.
Precast terrazzo tiles of 12.5 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 10 mm thick cement coarse sand plaster 1:3 and jointed with neat cement slurry in skirting, dado and risers of steps, including rubbing and polishing complete.
Miniature Circuit Breaker and Isolator.Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
Bakelite angle / straight button holder large size.( For ( bracket Lights & Mirror Lights )
Ceiling rose flush / surface type . (For Ex-Fans )
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire.Size 1.50 sqmm ( 48 / 0.20mm).
PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe.Fan Point- Long
PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe.Light Point- Long.
PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe.3 pin 5 amp. plug point including earthing the 3rd. pin etc with 2.5 sq mm PVC insulated copper conductor cable.- Short point.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.Size 1.5 sqmm (3 / 0.81mm).For earthing/misc wiring .
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. 25 mm dia
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp. 1 way switch
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp. Socket
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. Fan regulator
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. Blinking Plate
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material requiered to complete the job in all respect. 4 Modules (for Misc )
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material requiered to complete the job in all respect. 8 Modules
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes , iron hooks, cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. PVC pipe of 32 mm dia
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes , iron hooks, cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work. PVC pipe of 40 mm dia
TANUJ AGARWAL CONTRACTOR
Infinity Construction and Engineers
DHANSU JANGU COOP LC SOCIETY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .