Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹86.1 L
EMD Value
₹1.7 L
Closing Date
3 Dec 2026, 5:30 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MS PRIYANKA SHARMA(DFLT)
CHIEF ENGINEER ( TENDER CELL)
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-13-M-54 District- Raigarh
204230
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-13-M-54 District- Raigarh
RESTRICTED TENDER
WORKS
PERCENTAGE
6 days
CHIEF ENGINEER ( TENDER CELL)
Required Past Technical Experience: As per Tender document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
15 documents required · 15 mandatory
Panchayat and Rural Development (PARD)
WORKS
MS PRIYANKA SHARMA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
CHIEF ENGINEER ( TENDER CELL)
TENDER CELL
CGRRDA RAIPUR
90
06
No
1
204230
3 Dec, 2026 5:30:00 PM IST
7 Dec, 2026 6:05:46 PM IST
18 Nov, 2026 7:30:00 PM IST
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-13-M-54 District- Raigarh
NIT 1226 PMGSY Road Renewal Maintenance PKG No CG-13-M-54 District- Raigarh
172000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
8609000.00
2
7 Dec, 2026 5:30:33 PM IST
8609000
AS PER NIT
AS PER NIT
As per Tender document
5000.00 INR
14d 21h 29m
15 documents required · 14 mandatory · 1 optional
₹5,000
₹1.7 L
18 Nov 2026
18 Nov 2026
7 Dec 2026
18 Nov 2026
7 Dec 2026
90 days
Detail of Maintenance Work's Package
PIU-1, CGRRDA, Raigarh CG 13 M-54
S .No. Circle Dist. PIU Block Vidhansabha Pkg. No. Name of Road Length of Road (In Km.) Cost of Maintenance Work's for Five Year's (Amount in Lacs) Add 18 % GST Total Amount Remark's
Initial Rehabitation Work's A Annual Routine Maintenance B Renewal Work's C Total A+B+C+D
1 Raigarh Raigarh Raigarh Raigarh Raigarh CG 13 M-54 Loing to Kotarlia 2.5 4.888712 4.47 63.6 72.958712 13.13 86.088712
Executive Engineer
PIU, CGRRDA, Raigarh
Detail of Maintenance Work's Package
PIU-1, CGRRDA, Raigarh CG 13 M-54
S .No. Circle Dist. PIU Block Vidhansabha Pkg. No. No. of roads Length of Road (In Km.) Cost of Maintenance Work's for Five Year's (Amount in Lacs) Add 18 % GST Total Amount Remark's
Initial Rehabitation Work's A Annual Routine Maintenance B Renewal Work's C Total A+B+C+D
1 Raigarh Raigarh Raigarh Raigarh Raigarh CG 13 M-54 1 2.5 4.888712 4.47 63.6 72.958712 13.13 86.088712
Executive Engineer
PIU, CGRRDA, Raigarh
ESTIMATE OF I.R. Work
Type of CD - Proposed FCW AT RD 350M.
Name of Road :- Package No. :-
S. No. SSR Item No. Description Quantity Unit Rate Amount Remark
1 2.5 B Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of cement concrete including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. B Cement Concrete
Particular No Length Width Depth
2 9.1 A Excavation for Structures Earthwork in excavation for foundation of structures as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, sortingout servicible & unservicible materials and disposal of all materials upto 1000 m lead and backfilling with approved material. Ordinary soil
Particular No Length Width Depth
Protection wall (1.5+1.8)/2 2 5 1.4
11.4 (I) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10
Particular No Length Width Depth
Protection wall 2 5 1.4 0.15
11.4 (II) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15
Particular No Length Width Depth
Protection wall (1.2+0.4)/2 2 5 2.4
12.9 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Particular No Length Width Depth
7.3 B Granular Sub-base Construction of granular sub-base by providing well graded material, spreading in uniform layers with appropriate equipment on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with 8-10 t static roller to achieve the desired density, complete as per Technical Specification Clause 401 for gradings mentioned in table 400.1 (CBR 20 or more) B River born materials
Particular No Length Width Depth
7.5 Cement Concrete Slab Construction of un-reinforced and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and construction joints, applying debonding strips, primer, sealant, approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,
Particular No Length Width Depth
12.10 Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (I) Granular material
Particular No Length Width Depth
Team Leader Sub Engineer Assistant Engineer Executive Engineer
Sai Enterprises, Camp Betul PIU-1, CGRRDA, Raigarh PIU-1, CGRRDA, Raigarh PIU-1, CGRRDA, Raigarh
BILL OF QUANTITY
Name of Road : Loing to Kotarliya Package No. : CG 13 M-54
Block : Raigarh Length 2.50 km.
S.No. SSR Item No. Description Quantity Unit Rate Amount Remark
1 11.12(III) Cutting of branches of trees shrubs and trimming of grass and weeds.Trimming of grass and weeds from the shoulder/berms and disposing off the same to suitable locations as per technical specification clause 1914. 8250 SQM 3 24750
2 11.1 (i) Restoration of Rain Cuts Restoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment, level and slopes as per drawings and technical specifications Clause 1902 249.558875 CUM 273 68129.572875
3 11.1 (i) Scarifying Existing Granular bituminous Surface to a Depth of 100 mm Scarifying existing granular/bituminous surface upto a depth of 100 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. 8250 sqm 13 107250
4 3.12(b) (b) Construction of subgrade and earthen shoulders with approved material (Granular material having CBR not less than 10) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.(To be used for side shoulder WBM) 1527.8999999999999 sqm 223 340721.69999999995
5 4.8 Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406 1407.65625 sqm 1887 2656247.34375
6 5.1 Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 8497.5 sqm 62 526845
7 11.14 (1) (i) Tack Coat (i) Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.225 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. 8497.5 Sqm 21 178448
8 11.14 (1) (II) (ii) 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm size @ 0.18 cum per 10 sqm & 11.2 mm size @ 0.09 cum per 10 sqm aggregates using penetration grade/modified bitumen @ 14.6 kg/10sqm to required line, grade a II) Bitumen (VG-30) 8497.5 Sqm 166 1410585
9 11.14 (1) (IV)Case II Type B (ii) Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 Case - II : Type B II Bitumen (VG-30) 8497.5 Sqm 60 509850
10 9.16 Providing and Fixing 'PMGSY Sign board' and 'Logo' of PMGSY Project B PMGSY Logo Board Providing and fixing Logo Board of PMGSY size 600×600mm diamond shape with 1 plate of size 900×250 mm made of 16 gauge sheet over frame of angle iron 25×25×3mm as per PMGSY specifications & drawing, painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 2 Sqm 6626 13252
11 9.8 Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 (A) 200 m stone (precast)
Kilometre Stone 3 Each 2292 6876
200 m stone 10 Each 660 6600
12 9.2(A) Cautionary, mandatory, informatory, direction and place indentification signs Semi-Reflective Traffic signs up to 0.90 sqm size board Providing and erecting cautionary, mandatory, informatory, direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 9 Sqm 5285 47565
13 9.2 (B) Cautionary, mandatory, informatory, direction and place indentification signs Semi-Reflective Traffic signs up to 0.90 sqm size board Providing and erecting cautionary, mandatory, informatory, direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 2.7 Sqm 5756 15541
14 9.17 Reinforced cement concrete M15 grade grade Guard stone of size 200 mm * 200 mm * 800 mm fixing in position including painting and printing etc as per drawing, Technical Specification and as per direction of engineer incharge. 155 Each 525 81375
15 9.19 Speed Braker Providing and laying rounded hump type of Speed Breaker confirming to IRC – 99 and as per guidelines and drawings of NRRDA circular no. DO No. P-17019/6/2006/PII Dated 16 Sept 2009, including providing, laying and compaction of GSB, G II, G III, OGPC, Seal Coat Type B, as per specifications and appended drawing on both the sides of carriage way up to formation width maintaining rounded hump type shape with bituminous mix material i/c providing and painting of black and white strips, providing and fixing of two no. 600mm equilateral semi reflecting sign boards, i/c cost of all materials, labour T & P & Machinery etc complete and as directed by engineer in charge as per relevant clauses of MORD specifications. 4 Sqm 22547 90188
16 9.18 Road marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.) 440 Sqm 627 275880 63.09
17 9.15 (A) Maintenance Board Providing and fixing 'Citizen Information Board' of PMGSY Project(A) Providing and fixing of typical " PMGSY Citizen Information Board" with Logo as per MoRD specifications & drawings, made of 75 mm square or 75 mm dia circular steel tube of 12 SWG 3.2 m height and cross member 2 nos 1m long, fixed with angle iron 50x50x5 mm MS angle on the back 1 Each 14010 14010
18 9.14 (B) Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 1 Each 18610 18610
19 3.8(i) Construction of unlined surface drains of average cross sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m average lead 25 m) as per Technical Specification Clause 307. 380 Rm 99 37620
20 7.10 (ii) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 M-15 nominal mix 1:2.5:5 91.2 cum 4576 417331.2
21 11.13 White washing of parapet walls of CD work and tree truncks White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc as per technical specification clause 1915. 50 sqm 26 1300 4.52 72.08 85.05439999999999
Add 18% GST Say 1232815 0
TOTAL RENEWAL COST 8081789.816625
For Routine maintenance
Routine maintenance for 1st year after Renewal of BT Road 2.2 Km 22000 48400.00000000001
CC Road 0.3 Km 20500 6150
Routine maintenance for 2st year after Renewal of BT Road 2.2 Km 24000 52800.00000000001
CC Road 0.3 Km 20500 6150
Routine maintenance for 3st year after Renewal of BT Road 2.2 Km 29000 63800.00000000001
CC Road 0.3 Km 20500 6150
Routine maintenance for 4st year after Renewal of BT Road 2.2 Km 44000 96800.00000000001
CC Road 0.3 Km 20500 6150
Routine maintenance for 5st year after Renewal of BT Road 2.2 Km 70000 154000
Add 18% GST Say 80379 0
TOTAL MAINT. COST 526929
GRAND TOTAL (RENEWAL COST + MAINTENANCE COST ) WITH GST 8608718.816624999
SAY IN LAKH 86.08718816624999
Sub Engineer Assistant Engineer Executive Engineer
PIU, CGRRDA, Raigarh PIU, CGRRDA, Raigarh PIU, CGRRDA, Raigarh
CG 13-100 Renewal of BT Road Period Wise
PIU-1, CGRRDA, Raigarh
ESTIMATE OF I.R. Work
Type of CD - RD - 1500m. Ex. CC Both Side Paved Shoulder Length = 30m.
Name of Road :- Package No. :-
S. No. SSR Item No. Description Quantity Unit Rate Amount Remark
1 3.4 Excavation, Carting i/c Removal of Soil with Disposal upto 1000 m Excavation of embankment, sub-grade and drain consisting of excavation, removal and satisfactory disposal of all excavated materials including hauling to sides of embankment and subgrade construction as also the disposal of materials in specified manner and the trimming and finishing of the road to the specified dimensions i/c all lifts, lead upto 1000 meters including dewatering, shaping and excavation in marsh and complete disposal of all muck as per clause 302. for all types of soil i/c moorum gravel etc. as directed by the Engineer-in-charge
Particular No Length Width Depth
Shoulder 2 30 0.95 0.3
4.1 A Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1) Construction of granular sub-base by providing well graded material having CBR >= 20, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Technical Specification Clause 401 for gradings mentioned in table 400.1 A Crushed stone materials
Particular No Length Width Depth
11.4 (I) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10
Particular No Length Width Depth
PCC for Wall 2 30 0.3 0.1
Shoulder 2 30 1 0.1
11.4 (II) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15
Particular No Length Width Depth
Shoulder 2 30 1 0.1
Team Leader Sub Engineer Assistant Manager General Manager
Sai Enterprises, Camp Betul M.P.R.R.D.A. PIU-1, Betul M.P.R.R.D.A. PIU-1, Betul M.P.R.R.D.A. PIU-1, Betul
ESTIMATE OF I.R. Work
Type of CD - Proposed FCW AT RD 350M.
Name of Road :- Package No. :-
S. No. SSR Item No. Description Quantity Unit Rate Amount Remark
1 2.5 B Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of cement concrete including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. B Cement Concrete
Particular No Length Width Depth
2 9.1 A Excavation for Structures Earthwork in excavation for foundation of structures as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, sortingout servicible & unservicible materials and disposal of all materials upto 1000 m lead and backfilling with approved material. Ordinary soil
Particular No Length Width Depth
11.4 (I) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10
Particular No Length Width Depth
11.4 (II) Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15
Particular No Length Width Depth
12.9 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Particular No Length Width Depth
7.3 B Granular Sub-base Construction of granular sub-base by providing well graded material, spreading in uniform layers with appropriate equipment on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with 8-10 t static roller to achieve the desired density, complete as per Technical Specification Clause 401 for gradings mentioned in table 400.1 (CBR 20 or more) B River born materials
Particular No Length Width Depth
7.5 Cement Concrete Slab Construction of un-reinforced and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and construction joints, applying debonding strips, primer, sealant, approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,
Particular No Length Width Depth
Team Leader Sub Engineer Assistant Manager General Manager
Sai Enterprises, Camp Betul M.P.R.R.D.A. PIU-1, Betul M.P.R.R.D.A. PIU-1, Betul M.P.R.R.D.A. PIU-1, Betul
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
1588435723018103103_159177_1278507194557121433_80616_Guidelines to Bidders.pdf
NIT • 0.13 MB
3267424462656044226_204230_NIT 1226 Tender Document Renewal Maintenance.pdf
NIT • 1.77 MB
5477196928080721169_204230_Raigrh BOQ CG 13 M-54.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .