Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹23.3 L+₹81,220 (3.61%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹24.3 L+₹1.8 L (7.89%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹24.5 L+₹2.0 L (8.76%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹24.6 L+₹2.1 L (9.56%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹22.3 L
EMD Value
₹44,600
Closing Date
2 May 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF 02 X HIGH MAST LIGHT AT 58 WEU AT GANESHBARI UNDER GE DINJAN
2022_MES_517974_1
C/8413/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE DINJAN
₹44,600
Yes
8 Jul 2022
12 Apr 2022
4 May 2022
12 Apr 2022
2 May 2022
25 Apr 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil all as specified and as directed.
Excavating in trenches not exceeding 1.5 metre wide and exceeding 1.5 metre & not exceeding 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
M&L for cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:2:4) type C-1 using 20 mm graded stone aggregate as in coping of pole and stay etc including necessary form work for fair finish surfaces complete all as specified and directed
M&L for 150 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in footpath, plinth protection, etc, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc. inciuding 15 mm thick cement mortar (1:6) screed bed or bedding layer set and joined in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Supply & installation testing and commissioning of symmetric type galvanized steel high mast lighting system of 16 meter in length in two section, 3 mm & 4 mm section thickness, top dia 150 mm, bottom dia 360 mm, with AISI 3161 steel wire rope 7/19, 6 mm dia system 2 for wich and 3 for lantern carriage, including LED flood light 08 Nos 350 Watts, timer pannel, Complete all as specified and as directed including following :- (a) Sustain upto wind speed of 180 Kmph (b) Non Flame Proof integral Motor. (c) Movable lantern carriage. (d) Double drum Winch. (e) 6 mm 316 Grade S S Hoisting Ropes of 7/19 construction. (f) Trailing Cable –1 per mast (5 Core 2.5 Sq mm) (g) Lightning Finial , Anchor Plate & Template. (h) LED Aviation light. Model: GLN 703 (i) 350W LED Flood light 8nos Model: CFS-501-350-57-60D-SL-GL-NGG (j) Accessories like Plug and Socket, GI Nut bolt with double washer,wiring cable for fixture, flexible conduit, copper lug, PVC tape, Cable tie etc (k) Foundation Bolt & Nuts T & P for fixing with its allied accessories as per OEM. System is suitable for loading 08 nos 350 w LED lights (l) Installation, Testing & Commissioning, Casting of foundation for High Mast & Panel @10T/sqm soil bearing as per OEM. (m) Earthing for High Mast & Panel, Power Supply up to the Panel & Cable laying, Providing Power Cable from High Mast to Panel. Note: Installation should be complete in presence of OEM Rep Make & Model HM-16A-LM-ACC of Crompton /Havells /Phillips / Bajaj.
Supply only astral flood light 350 W made of pressure die cast housing with toughened glass and indivdual high pwer LEDs with secondary optics PC with IP66 protection and impact resistance of IK07 protection complete including multistrand copper conductor cable with suitable length for fixed to high mast light as spare etc complete all as specified and as directed
S&F for MCCB, AC, 415 Volts, 63 Amp, breaking capacity 16 KA, 4 Pole, with fixed thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed. Make : Cat No TABBASIX1063D4P of HPL /Havells/Legrand/L&T.
S&F for bus bar panel out door type for cable of size 25 sqmm 4 core with MCB protection of suitable size all as specified and as directed.
M/S CHANDAN ENTERPRISE
M/S AUTOMOTIVE WORLD
M/S Karen Enterprises
M/s GANDHESWAR PHUKAN
STANDARD ELECTRIC WINDERS
M/S BORAH BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .