Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.3 L+₹3.8 L (27.7%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC L2 | |
| 3 | L3₹18.3 L+₹4.8 L (35.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted wirh Appropriate Category |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Repair/Maintenance of summer and winter cooling appliance and central air cooling system at RMS Dholpur under GE Bharatpur
2023_MES_605597_1
8283/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹40,000
Yes
4 Oct 2023
26 Jun 2023
21 Aug 2023
26 Jun 2023
19 Aug 2023
5 Aug 2023
27 Jun 2023 - 16 Jul 2023
Amount
Taking out and servicing of window/split type air conditioner cap- 1.5/2.0 Ton incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete all as specified and as directed . Note: Spare parts shall be measrured & paid separately under respective items.
M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -410/R-22 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for folowing capacity split type air conditioner complete all as specified and as directed.
1.5 Ton Capacity
2.0 Ton Capacity
S & F in replacement of following items for window/ Split AC of any capacity:
Compressor for AC Capacity- 1.5 Ton for window/split AC (as per site requirement) as per existing Make of LG/Voltas/Carrier/Tecumesh
Compressor for AC Capacity- 2.0Ton for window/split AC (as per site requirement) as per existing make of LG/Voltas/Carrier/Tecumesh
Starting Capacitor 80-100 / 100-120 MFD, Make : TESLA/ Godrej or Equivalent make approved by GE.
Running Capacitor 36 MFD/ 45 MFD, Make : TESLA/ or Equivalent make approved by GE.
Screen filter of air conditioner of cap - 1.5 / 2.0 TR as per existing make.
Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make approved by GE
Thermostatic switch suitable for window/split type AC 1.5/2.0 Ton capacity of existing make.
Fan motor with fan blade unit suitable for 1.5 Ton capacity window /split type air conditioner of existing make.
Condenser's fan motor with blade suitable for split type air conditioner
Electronic panel board / PCB with display of Airconditioner cap- 1.5TR/2TR .
Plastic water drain hose pipe, 15mm dia and 2mtr long for spit type AC .
Remote control operating device for Window/Split type AC of 1.5/2.0 Ton of existing make with 02 Nos of pencil battery.
Pencil batteries for remote of split/window AC.Make: duracell
Copper tubes of size 4/8, 1/2 inch with aerofoam NBR rubber insulation tube .
Copper tubes of size 3/8,5/8, 1/4 inch with aerofoam NBR rubber insulation tube . (Note for Srl item No 5 to 5.2 here in before: Fixing shall be measured and paid under respective item)
stand for outdoor unit of existing size complete all as specified and directed.
S & F indoor unit complete of existing make and size for split AC 1.5 TR including taking out old unsv complete all as specified and as directed by Engr-in-charge
S & F outdoor unit complete of existing make and size for split AC 1.5 TR including taking out old unsv and complete all as specified and as directed by Engr-in-charge
Shifting of AC, any type, of AC capacity 1.5/2.0 Ton complete indoor & out door unit including taking out brackets, pipe line and fixing insulating pipelines including brazing of copper tubes, testing/commissioning complete, the shifting of service connection and voltage stabilizer to the new location complete all as specified and as directed Note: Rate for transportation, civil work and making good to the disturb surfaces deemed to be included in quoted rate.
Taking out and servicing of electric driven single phase water cooler of any cap incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air / water jet using detergent solution or chemical solution , leakage testing of refrigerant,storage tank leakage testing complete all as specified and as directed . Note: Spare parts shall be measrured & paid separately under respective items.
M & L for painting of water coolers of Cap - 80/120 Ltrs, with applying two coats of synthetic enamel paint of Make : Asian Paints Ltd ( Ist quality) /Berger/ Jansen and Nicholsen or equivalent, of approved colour by using spray painting technique to match with existing colour including cleaning old deteriorated exterior surface and necessary prepartion of surface by scrapping rust, grease, dirt etc, at existing location complete all as specified and directed by Engr in charge.
Ditto all as per Srl Item No 8 here in before but of Water cooler capacity 60/40 Ltrs.
M & L for flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-134a at appropriate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site for water cooler of cap 80/120 ltrs of Make : Bluestar/Usha/Voltas complete all as specified and directed by Engr in charge.
All as per serial item No-10 above but of Water cooler capacity 80/40 Ltrs.
S & F in replacement of following items for water cooler of any capacity:-
Compressor unit for water cooler 120/80 Ltrs of existing make or any other make apporved by GE as per List of Make.
Compressor unit for water cooler 60/40Ltrs of existing make or any other make apporved by GE as per List of Make.
Condenser fan motor with fan blade for water cooler of any Cap of existing make or any other make apporved by GE as per List of Make.
Capacitor 25/35 MFD, ISI marked.
Thermostat with knob as per existing size and make.
Relay with overload protection assembly
Magnetic rubber gasket of top cover as per existing size and make
Drain water tray of stainless steel by brazing/soldering the joints, vent pipes, outlet etc as per existing size and make
Pencil type strainer alongwith capillary tube suitable as per existing size and make.
Float valve PVC 15mm bore, heavy duty. (Make: Prayag, Surya)
chromium plated push cock size 15 mm suitable Make: Liberty/Onida/CSON
PVC flexible pipe size 40 mm dia with necessary clamping with jubli clips for drain water tray
PVC connection of size 15 mm dia 450mm long
M&L for storage tank leakage repair through brazzing/welding/silicon gel fiiling of any capacity water cooler complete all as specified
Taking out and servicing of electric driven single phase refrigerators and deep freezer of any cap incluiding cleaning/removing all dust / mud, oil and other foreign particle with compressed air/water jet using detergent solution or chemical solution ,leakage testing of refrigerant,freezer storage leakage testing complete all as specified and as directed . Note: Spare parts shall be measrured & paid separately under respective items.
M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -22/R-134a (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for Refrigerator / deep freezer of Cap - 170/190 Ltrs complete all as specified and as directed.
All as per serial item No. 15 here –in before but of capacity 265/280 Ltrs complete all as specified and as directed .
All as per serial item No. 15 here –in before but of capacity 300-400 Ltrs complete all as specified and as directed .
S & F in replacement of following items for refrigerator/deep frezer of any capacity :-
Compressor unit for Refrigerator of cap 165-195Ltrs of existing make or any other make apporved by GE as per List of Make..
Compressor unit for Refrigerator of cap 200-320Ltrs complete all as specified and as directed .
Compressor unit for Refrigerator/Deep freezer of cap 200-400Ltrs complete all as specified and as directed .
Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make approved by GE
Thermostatic switch auto defrost type with knob suitable for existing refrigerator complete all as specified and as directed .
Bulb inside the refrigerator suitable for existing refrigerator complete all as specified and as directed .
Magnetic rubber door gasket suitable for existing refrigerator complete all as specified and as directed .
Push type door switch suitable for existing refrigerator complete all as specified and as directed .
Door lock with two keys suitable for existing refrigerator complete all as specified and as directed .
Overload protector suitable for refrigerator . Make: INDFOSS/DANFOSS or equivalent make approved by GE
Strainer pencil type alongwith capillary tube suitable for refrigerator as per existing capacity complete all as specified and as directed .
Electronic PCB for 260-400 Ltr refrigerator /Deep freezer complete all as specified and as directed .
Taking out and servicing of desert cooler of any capacity i.e. checking of desert cooler fan motor, submersible pump, socket point, PVC connections,Fan blade, wooden chips etc including noting the complaints in compliant register complete all as directed by Engineer - in - Charge. Note: Spare parts shall be measrured & paid separately under respective items.
S & F in replacement of following items for desert cooler, of any capacity:-
Cutting burnt winding of fan motor of size upto 450mm sweep and rewinding with super enamelled copper winding wire and replacing gun metal bush shaft complete all as specified and directed.
M&L for painting of desert cooler inner and outer surface with spray gun using one coat of red oxide and two coat of anti corrosive synthetic enamaled paint of approved brand as directed by Engr-in-charge
S & F of Fan Motor copper wound 16/18" sweep, 3 Speed single phase 230V AC supply complete with Blade (Make: Khaitan/Crompton Greaves/Bajaj)
M & L for MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model cmplete all as specified and directed.
S & F of PVC submersible Pump complete single phase 230V AC supply for desert cooler, 1 meter head or suitable to existing desert cooler complete all as specified and directed. Make: Khaitan/Crompton Greaves/ Bajaj/ Summercool
M & L for Side panel/shutter made out of 20 SWG GI sheet as per existing design and approved including handles (2 Nos.) duly welded / riveted complete all as specified and as directed .
M & L for Bottam tank made out of 20 SWG GI sheet as per existing unserviceable tank complete all as specified and as directed .
M & L for Top of the Desert Cooler made of 20 gauge GI Sheet riveted /bolted to match with existing complete all as specified and as directed .
S & F of PVC water distribution cup with PVC elbow and pipe for any size of cooler complete all as specified and as directed.
S & F of Capacitor cap- 4/6 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan
S & F in repair of Piano switch 5 amps one way complete all as specified and as directed.
S & F in repair of 3 pin plug top 5 Amp complete all as specified and as directed.
M & L in repair for twin core 1.5 Sqmm copper conductor wire for internal wiring complete all as specified and as directed.
S & F in repair of Float valve PVC 15mm bore, heavy duty. (Make: Prayag, Surya)
S & F in repair of PVC connection 45 cm long. (Make: Prayag)
S & F in repiar of PVC connection 60 cm long. (Make: Prayag)
M & L for Wooden chips pad of suitale size for 03 side shutters of desert cooler min 600gm in weight complete all as specified and as directed..
M & L for PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 2.5 sqmm.
S & F of 3 pin plug top 15 Amp. Make : ANCHOR or equivaqlent make as per List of Make complete all as specified and as directed.
S & F of brass stop cock/ Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore pipes complete all as specified and directed.
S & F of brass stop cock Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 20 mm bore pipes complete
Taking out old unserviceable parts from Desert cooler and supply & fix new parts of desert cooler to make functioning of the same. (a) Desert ccoler body complete with front grill made out of GI sheet of overall dimension of desrt cooler 690X690X1020mm with mounting frame for fixing of cooler fan motor, Air grill of suitable size made out of 0.5mm PGI sheet including GSS arrangement with a knob for easy and smooth movement, Front & Side panel made out of 1mm thick PGI sheet of suitable size and shape, Water tank height should not less than 11 inch made out of 1mm thk PGI sheet, wooden chips pad for three side shutters,Service cord of 3 Core copper wire 1.5 Sqmm with plug top 5 Amp length not less than 2 metres, Electronic fan dimmer 1000 watts AC 230 Volt for controlling the fan speed complete all as specified and directed.
Supply & Fixing plywood 6mm thick with white mica sheet duly fixed in windows with screws for ventilation opening for desert cooler as per existing size complete all as specified and directed by Engr in Charge.
M&L for fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of cap 3000/4000CFM made out of angle iron section complete with two coats of synthetic enammled black paint over a coat of red oxide primer all as specified and directed by Engr in Charge.
S&F in replacement GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc incluiding necessary excavation and earth work complete for desert cooler/water cooler connections complete all as specified and as directed by Engr in charge. (Make: Surya/Prakash/Tata/Jindal)
Ditto all as per Srl Item No 23 here in before but of 20mm bore
S&F modular enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 25 Amps, 240 volts. Make- L&T, Havells, Legrand complete all as per specified by Engr-in-charge.
M&L concealed submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified and as directed.
M&L concealed submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified and as directed.
Taking down u/s air washer, cleaning and removing dust particles inside the chamber of air washer container, disconnecting all electrical wires with proper termination and insulating the naked wires if any, removing unsv FASD starters etc and refitting the all removed and items after repairing/replacing at site as per the existing position all as specified and directed by Engr-in-Charge
Dismantling the joints of each compartment of duct and cleaning of duct from air washer (Aier Handling Unit) outlet to cadet's room opening of any length by using anti scaling spray, scrapping the foreign materials deposited on internal wall of the duct, opening the outlet grills, blowing air with high pressure through duct to get the deposited foreign materials by using external heavy duty compressor, applying oil spray inside the duct to prevent the sheet from corrosion with very thin layer, connecting all the compartments as per existing position, replacing gasket at all joints, all as specified ans as directed by Engineer-in-Charge.
M&L for replacing insulating layer over the duct to prevent from heat or any extreme weather by using synthetic foam or synthetic rubber and wrapping with garnison net or square threaded net around the insulation by using suitable solvent or compound to stick permanenty after dismantling the old UNSV insulation layer and scrapping the surface and cleaning properly before applying the new insulation layer all as specified and as directed by Engineer-in-Charge
M&L for checking all the water pipeline connections, repairing leakages from PVC storage tank to air washer system storage tank, welding the cracks or hole or fabricating with new sheet for 40mm GI drain out pipes, replacing end plug of drain system and over flow system of bottom mount tank, checking the condition of float valves, cleaning the valve and refitting, leakage testing and rectifying in all respect in pipeline and existing tank and making fucntional complete all as specified and as directed.
S&F in repairing the following accessories of Air Washer (Air Handling Unit):
DOL Starter of capacity 5HP suitable for three phase 3HP motors complete with on off push buttons and over current relay complete all as specified and as directed. Make-Legrand/L&T or equivalent approved Make.
Rewinding 5HP motor of blower fan motor by using super enamelled copper conductor wire solid in nature, grade 1 quality, incl dismantling/assembling and transporting etc. and refixing after repairing and replacing of UNSV parts such as housing/nuts bolts etc complete all as specified and as directed and as directed.
S&F bearing of motor suitable for 5HP Make CG, in repairing incl taking out old UNSV , applying suitable grease and test run etc complete all as specified and as directed
Supply and fix in repair cassete filter of size 2x2 feet 50 mm thick complete all as specified and as directed
Supply and fix motor fan belt of suitable size genuine part from the Air systems complete all as specified and as directed.
Supply and fix in repairing compartment door of Mild Steel of size 27.5 inch x 55.5 inchx 1 inch, with AHU door locking arrangements, hand lock and key, painting of metal primer and two coat super enamel paint with existing colour and finish includng removing of UNSV door etc complete all as specified and as directed.
Supply and fix submersibble pump set of 32 watt of output 3200 L/H , 220V, 50 Hz for a height of 2.95 mtr all as specified and directed by engineer-in-charge
S&F PVC float valve of size 25mm/20mm as required on site including rod and ball in replacement of old UNSV one and testing all as specified and as directed by Engineer-in-Charge
S&F PVC pipe in replace ment of UNSV and broken of size 25mm with suitable compound for jointing over the pump outlet including all kind of accessorie all as specified and as directed by Engineer-in-Charge
S&F of PVC valve 25mm size along with PVC union in replacement of old UNSV one all as specified and as directed by Engineer-in-Charge
S&F in replacement of air filtration pad (compact honey pad), 1.22m x 1.22m corrugated, thin sponge layer consisting, of paper membrane as one layer, net cloth as second layer and foam as third layer suitable to filter the inlet air entering into the air washer system while running the plant of dimension 1.22m x 1.22m of thichness 8 inch or as per existing size suitable for air washer system including fixing pad, nuts bolts and accessories etc all as specified and as directed by Engineer-in-Charge.
S&F PVC float valve of size 15mm as required on site including rod and ball in replacement of old UNSV one and testing all as specified and as directed by Engineer-in-Charge
M&L for PCC 1:2:4, type B2 (using 40 mm graded stone aggergate) as in foundation and mass concrete for poles/Stay wires/ LT panel boards complete all as specified and as directed by Engr-in-Charge .
S&F Voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type, designed for input variation between 170V to 250V with output voltage stabilized at 230V, with accuracy +/- 2.5% of capcity 5KVA fixed on wall or any location as directed including connected accessories complete all as specified and as directed by Engineer-in-Charge.
S&F Voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type, designed for input variation between 170V to 250V with output voltage stabilized at 230V, with accuracy +/- 2.5% of capcity 4KVA fixed on wall or any location as directed including connected accessories complete all as specified and as directed by Engineer-in-Charge.
Labour only for day to day complaints of all cooling appliance AC,water cooler ,refrigerator,desert cooler,deepfreezer etc including servicing any type and size all as specified and directed by engineer-in-charge
Taking out old Existing U/S MCCB from LT panels/ Feeder piller of following capacity and replace with new MCCBs without damaging the LT panel board or any assets associated with the installation. Make Havells/L&T/ABB/Schneider.
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA complete all as specified and as directed by engineer-in-charge
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KAcomplete all as specified and as directed by engineer-in-charge
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 63 Amps with breaking capacity 36 KA complete all as specified and as directed by engineer-in-charge
Supply and fix MCCB 4 Pole, 415 V, with Microprocessor release 100 Amps with breaking capacity 36 KA complete all as specified and as directed by engineer-in-charge
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 50 Sqmm 3.5core for air cooling system complete all as specified and as directed by Engineer in Charge.
-ditto- as per Ser No-38 here-in-before but of size 25 sqmmx 4 core complete all as specified and as directed.
-ditto- as per Ser No-38 here-in-before but of size 16 sqmmx 4 core complete all as specified and as directed.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, and getting out in hard disintegrated layer complete all as specified and as directed.
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as specified and as directed.
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Supply and laying of unburnt Sub class B Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length complete all as specified and as directed by Engineer-in-Charge.
M &L local river sand for bedding and sand cushioning of all HT/LT UG cable complete all as specified and directed by Engr-in-Charge. (punned thickness of sand shall be measured.)
Labour for cleaning of solar plate(2x1m) complete all as specified and as directed by engineer-in-charge
M&L for top up of distilled water in battery complete all as specified and directed by engineer-in-charge
M&L pipe galvanized iron medium grade of 25 mm dia complete with all fittings and fixed complete to wall or ceiling or laid in floor jointed tested and commissioned compete all as specified and directed by engineer-in-charge
Material and labour for rotational moulded polyethylene water storage tank . Three layered, 1000ltrs (cylindrical vertical with closed top ) hoisted and fixed in position including float valve complete all as specified and as directed.
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars 400 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.00 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for base frame work.including change over 160amp.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings :- Incoming:- (a) MCCB TPN- 250 Amps ------ 01 Nos. (b) Bus bar Al TPN 400 Amps ------ 01set. Outgoing (b) MCCB TPN 160 AMP 25KA ------04 nos
PD GUPTA AND COMPANY
M/S MAKHIJA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .