Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
29 Sept 2022, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-61/2022-23 REPAIR/MAINT OF FLOOD LIGHT, SOLAR LIGHT AND ANNUAL MAINTENANCE CONTRACT FOR FIRE ALARM, AMR ELECTRIC ENERGY METERS AND OTHER MISC WORKS AT AF STATION PALAM UNDER GE (P) AF GURGAON
2022_MES_547659_1
GE (P) AF/Gur-61/2022-23
Open Tender
Miscellaneous Works
Item Rate
272 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹97,000
Yes
14 Oct 2022
25 Aug 2022
1 Oct 2022
25 Aug 2022
29 Sept 2022
8 Sept 2022
Amount
Comprehensive maintenance for single phase AMR meter software hosting, GPRS Charges, meter calibration testing with multimeter, RF network monitoring and trouble shooting and repair/replacement of meter parts with manufactruing defect complete all as specified and as directed by Engr-in-charge (AMC for 430 Meter/ per month for 09 Months).
Comprehensive maintenance for for three phase AMR meter software hosting, ,GPRS Charges, meter calibration testing with multimeter, RF network monitoring and troubleshooting and repair/replacement of meter with manufactruing defect complete all as specified and as directed by Engr-in-charge.(AMC for 74 Meter/ per month for 09 Months).
Comprehensive monthly maintence of auto fire alarm system installed in 13 BRD/16 BRD /27 ED AF Stn Palam. The detail scope of work consists of the following :- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge on monthly basis. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Material required for replacement shall be measured and paid separately under respective items of this schedule as 'Supply and fixing' and labour component for the same is not included in comprehensive maintanance contractor shall quote the rate accordingly. (vii) Testing of entire fire alarm system and rectification of fault complete to the entire satisfaction of engr-in-charge all as specified and directed .
Supply and fixing in replacement of gear and pinion system for high mast light fitting complete all as specified and directed.
Supply and installation in replacement of response indicator lamp complete all as specified and as directed.
S&F in replacement of addressable duct detector with multiple sensitivity level, programmable for timed automatic sensitivity and with base UL listed complete all asspecified and directed.
S&F in replacement of Analogue addressable control modules complete all as specified and directed.
S&F in replacement of Analogue addressable fault isolator module capable of monitoring shorted loop circuit and automatically restore communication when shorted conditions are re corrected complete all as specified and directed.
S&F in replacement of Addressable Dual tone electronic sounder / hooter enclosed in MS box with LED indication hooter complete all as specified and directed.
M&L 2x1.5sqmm+1x1sqmm PVC insulated unsheathed, FRL Smultistr and edcopper conductor cable,1100V grade asper IS1554 Part Idrawn through and including ERW steel conduitnot less than 20 mm dia duly painted complete all asspecified and directed.
M&L 2x4.0 sq mm +1x2.5 sq mm PVC insulated unsheathed, FRL Smultistr and edcopper conductor cable, 1100V grade asper IS1554 Part I dra wn through and including ERW steel conduit not less than 20mm dia duly painted complete all asspecified and directed.
S&F in replacement of 9 volts DC battery for wireless smoke detector complete all as specified and as directed.
S&F in replacement of hooter radio meter operating voltage 15 volts DC, indication alarm 85 db, complete all as specified and directed.make : AGNI Protection/Quatac/Honey well
S&F in replacement of MCP remote key of black colour including testing with battery complete all as specified and directed. Model no AP RE-920 of make : AGNI Protection/Quatac/Honey well
M&L in replacement of wire less smoke detector having 9 volt DC battery, smoke sencor temp range (10-70 ) degree centigrade, humidity range 20 % to 95 %, including testing complete all as specified and directed. Model no AP SD-900 of make : AGNI Protection/Quatac/Honey well
Supply and fixing in replacement of response indicator as per existing make and model complete all as specified and directed.
Supply and installation in replacement of 12 volt 7 AH battery complete all as specified and directed. Make - Exide /Amaron/ Luminous/ Amco
Taking down of old unserviceable optical type smoke detector and supply and testing of detectors complying with and type certified to EN-45 adjustable type smoke detector Photo electric / Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed . Make Cooper/Honeywell/Ravel/Apollo
Supply and fixing in replacement of mother board suitable for Fire alarm system complete all as specified and directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
Supply and fixing in replacement of Power Supply card suitable for Fire alarm system complete all as specified and directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
Supply and fixing in replacement of manual call point resettable type complete as directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
Supply and fixing in replacement of electronic sounder cum strobe complete all as directed.Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
Supply and fixing in replacement of Repeater Panel 08 Zone complete all as specified and directed. Make : Agni/Cooper/ Honeywell/ Ravel/Apollo
Supply and fixing in replacement of 1.5 sqmm three core PVC insulated sheathed ISI marked FRLS copper conductor multi stranded 1100 volt grade cable drawn through existing conduit connecting and testing all as specified and directed.
Supply and fixing in replacement of Heat Detector with Base complete all as specified and directed. Make : Apollo/ Honeywell/Ravel/ Copper
Supply, installing, connecting and testing in replacement of Three phase automatic change over switch of capacity TPN 63 Amps complete all as specified and directed. Make:- Havells Cat part No. DHACOTN8063 or equivalent out of make specified in list of make.
M&L in replacement of 4.0 sq mm 3 core PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade as per IS1554 Part I drawn through and including ERW steel conduit not less than 20 mm dia duly painted complete all asspecified and directed.
Comprehensive monthly maintence of 3 X 30 KVA UPS system installed in 13 BRD AF Stn Palam. The detail scope of work consists of the following :- (i) Execute diagnostics and physical checks. (ii) Examine, clean, test, all equipment as required and repair parts as and when required. (iii) Measurement of UPS parameters like input/output voltage, frequency, current, frequency, room temperature etc. (iv) Battery Parameters like voltage, current and other relevant parameters. (v) Ensure dust free and controlled temperature conditions. (vi) The corrective maintenance may require multiple visits to site (vii) Check all Equipment LED LCD display board if any fault found to be rectified in the same cost.(viii) Checking of servicibility of MCB/MCCB if found unserviceagle to be replace without any extra cost. (ix) Checking of UPS fuse. if found us to be replace.(x) Keeping of servicibility of UPS is the responsibility of the contractor for the entire contract period. Note : Response time should be not more than 24 hours from the time of receipt of complaint on any working day between 9 AM to 6 PM.
Supply and fixing in replacement of Bus Trunking having copper bus bar of cap 40 Amp 3L+N+PE, F 50HZ with insulator and tap off unit at each 0.5 mtr intervals all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Bus Trunking having copper bus bar of cap 60 Amp 3L+N+PE, F 50HZ with insulator and tap off unit at each 0.5 mtr intervals all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of Class II Three Phase Lightning & Surge Protection Device for Main Incoming Panel of Lab for giving Protection against LIGHTNING, SURGES, TRANSIENTS, ELECTRO MAGNETIC INTERFERENCE, RADIO FREQUENCY INTERFERENCE, THERMAL FUSING AND SHORT CIRCUIT FUSING with following specifications: a) SPD shall be suitable for a working voltage of 240/415V, 3 phase 4 wire systems and surface mount. b) Maximum continues operating voltage of the SPD shall be not less than 290V. c) SPD shall be compact and with flying leads of minimum 5 sqmm. d) SPD shall have Green , Red LED Status Indicator, Remote Signaling and Audible Alarm which triggers during fault. e) SPD must be rated for Maximum Surge Current of 80kA and a nominal discharge rating of 20kA (8/20 micro sec) . f) SPD must have a Short Circuit Current Rating of not less than 100kA Amperes Interrupting Current (AIC). g) The voltage protection rating for L-N,L-G and N-G shall be less than 1200V. h) SPD must have a filtering circuit with Max noise attenuation of -75dB for 100kHz to 100MHz to give a low residual voltage for the connected equipment during surge. i) SPD shall have ambient temperature limits of -40° C to +60° C with humidity of 95% RH (non-condensing). j) SPD shall be UL1449, 4th edition listed. k) SPD shall have EMC Compliance / BS EN: 60950: 1992; BS EN 61000-6- 2:1999 ANSI IEEE C62.45; ANSI IEEE C62.41. m) Warranty: 10 YEARS "No Fuss" Replacement.
Disconnect the unserviceable battery lead connections from 65 AH SMF battery of 30 KVA UPS and transport the us battery to work shop for reconditioning work by using dedicated battery regenerator. Sulfation on plates should be removed by using high powered pulses, replace the us battery terminals , replace the electrolyte and recharge the battery upto 24 to 36 hours to gain more than 12 volts. After completion of reconditioning work the battery will be refix at the same position including necessary testings complete all as specified and directed.
Disconnect the cable connection from unserviceable electric siren from site and refixing the same after completion of necessary repair work complete all as specified and as directed
M&L for opening of electric siren motor and , cutting the burnt winding from motor and rewinding the motor with super enamelled copper wire as per existing size and gauge with and including provision of insulating material varnishing with good quality varnish including replacement of all unserviceable parts such as safety pin, fan blade,bearings and three core copper wire etc complete all as specified and as directed by Engr-in-charge.
Repair/Servicing of Siren,horizontal double mounting, single phase,audible range 3.25 KM at 220/250 volt, 6000 rpm, 50 Hz, AC complete all as specified and directed.
M&L in replacement of 3 core copper conductor of size 2.5 sqmm cable 1100V grade complete all as specified and as directed by Engineer- in Charge.
Disconnect the cable connection from unserviceable single phase AMR meter from existing meter panel box and deposit to MES office complete all as specified and as directed
Disconnect the cable connection from unserviceable three phase AMR meter from existing meter panel box and deposit to MES office complete all as specified and as directed
S&F in replacement of unserviceable Single Phase AMR Meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyanconnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from billing software MAKE: Secure, L&T, Schnieder
S&F in replacement of unserviceable Three Phase AMR Meter with the following specifications: • AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyanconnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from billing software MAKE: Secure, L&T, Schnieder
M&L for repair of single phase AMR meter two wire LCD dispaly/ dial type any make 5-30 Amps complete all as specified and as directed by Engineer- in Charge.
M&L for repair of three phase AMR meter four wire LCD dispaly/ dial type any make complete all as specified and as directed by Engineer- in Charge.
Taking down unsv MCCBs from LT Panels distribution boards of any type and capacity , and removing the same from site and making necessary cable connections complete all as directed. Note : New MCCBs will be maeasured and paid separately in respective of BOQ item
S&F in replacement of MCCB 4 pole 125A, fixed type, breaking capacity 16KA fixed in bus bar or in LT panels, complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 4 pole, 250A, with Microprocessor release breaking capacity 36 KA fixed in bus bar or in LT panels, complete all as specified and as directed by Engr-in-charge.
S&F in replacement of MCCB 4 pole, 400A, with Microprocessor release breaking capacity 36 KA fixed in bus bar or in LT panels, complete all as specified and as directed by Engr-in-charge.
Taking down any type of street light /flood light fitting to any size and type from existing LT pole, bldg, complete for repair and refixing to existing position after repairing complete all as specified and directed by Engr-in-Charge. (spares required for repair shall be measured and paid separately).
S&F in replacement of 70 watt LED street light luminaries New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07,240 V AC suitable for pole mounting of bracket 60mm dia with all accessories and as directed by EIC. Make : Havells CAT Part No ENDURAPEARLNEOSL70WLED757PASYTOPC or equivalent of Bajaj/CG/HPL/GE / Eveready.
S&F in replacement of 90 watt LED street light luminaries New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07,240 V AC suitable for pole mounting of bracket 60mm dia with all accessories and as directed by EIC. Make : Havells CAT Part No ENDURAOMNIPLUSSL90WLED757SASYTOPC or equivalent of Bajaj/CG/HPL/GE / Eveready.
S&F in replacement of 100 watt LED street light luminaries New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07,240 V AC suitable for pole mounting of bracket 60mm dia with all accessories and as directed by EIC. Make : Havells CAT Part No ENDURAOMNIPLUSSL100WLED757SASYTOPC or equivalent of Bajaj/CG/HPL/GE / Eveready.
S&F in replacement of 150 watt LED street light luminaries New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07,240 V AC suitable for pole mounting of bracket 60mm dia with all accessories and as directed by EIC. Make : Havells CAT Part No ENDURAPEARLMAGNUMSL150WLED757PASYTOTGHO or equivalent of Bajaj/CG/HPL/GE.
S&F in replacemetn of 45/50 watt LED flood light energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power COB LEDs as light source, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. Make:- CAT Part No JETAQUANTOPLUSFLP50WLED757SYM of Havells or equivalent of Bajaj/CG/HPL/GE.
S&F in replacemetn of 150 watt LED flood light energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power COB LEDs as light source, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. Make:- CAT Part No JETAIRISFL150WLED757ARNBLTG of Havells or equivalent of Bajaj/CG/HPL/GE.
S&F in replacemetn of 200 watt LED flood light energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power COB LEDs as light source, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. Make:- CAT Part No JETAIRISMAXFL200WLED757PWBLTG of Havells or equivalent of Bajaj/CG/HPL/GE / Eveready.
S&F in replacemetn of 300 watt LED flood light energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power COB LEDs as light source, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. Make:- CAT Part No JETAIRISMAXFL300WLED757PNBLTG of Havells or equivalent of Bajaj/CG/HPL/GE / Eveready.
S&F in replacement of 2.5 Sqmm two core stranded PVC insulated copper conductor FRLS cable for connection of fittings complete all as specified and as directed by Engr-in-charge.
S&F in replacement of 32 Ah Li-ion solar battery suitable for 30 watt street light fitting as per sample complete all as specified and directed
Disconnecting and taking out 3 Phase forward and reverse motor of capacity 1.0/1.5 HP motor from existing highmast tower enclosure including rewinding with super enameled copper wire, replacement of neck rings, sleeves bushing , seal complete all as specified and directed.
Disconnecting and taking out forward and reverse motor of capacity 1.0/1.5 HP motor from existing highmast tower enclosure including Servicing , testing & commissioning at same place complete all as specified and directed.
Supply and fixing in replacement of Programmable Time Switch 24 Hour (SST - 15 min) outdoor/semi-indoor lights) for high mast tower controller panel same as per the sample in the existing High mast panel complete all as specified and directed. Make:- Nature switch or equivalent in HPL/L&T/EE.
Supply and fixing in replacement of steel wire rope for high mast light fitting complete all as specified and directed.
M&L for repair of electric meter single phase two wire LCD dispaly/ dial type any make 5-30 Amps complete all as specified and as directed by Engineer- in Charge.
M&L for repair of electric meter three phase four wire LCD dispaly/ dial type any make complete all as specified and as directed by Engineer- in Charge.
S&F ISI marked electric energy meter single phase two wire LCD dispaly 5-30 Amps complete all as specified and as directed by Engineer- in Charge. Make:- HPL/BENTEC/ Secure
S&F ISI marked electric energy meter three phase four wire LCD dispaly 10-60 Amps complete all as specified and as directed by Engineer- in Charge. Make:- HPL/BENTEC/ Secure
Notes:- (a) The amount of Rs 67674.00/- against Schedule of Credit shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) Any material required to be replaced for complaint rectification other than screws, PVC rawl plug, nuts & bolts, insulation tape, thimbles and as specified in complaint item shall be measured and paid seperately under respective supply only item. (c) The cost of attending complaints shall also include the cost of stationery required for recording complaint, complaint slips and its reports as directed by Engineer-in-charge. (d) All the complaint registered (except point wiring / sub-main wiring and connected S&F items) before 1000 Hrs of every day shall be rectified on same day upto 1700 Hrs. Any delay in complaint rectification a penalty shall be recovered @ Rs.100/ per complaint per day. (e) The items supplied by contractor as supply only shall be taken on charge by deptt. and shall be issued to contractor's trademen for incorporation against the complaints slips under item No 30 hereinbefore and proper records of same shall be maintained. (f) All T&P required by electrician for complaint rectification shall be provided by the contractor at his own cost. (g) Any desturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
Rajindera Enterprises
Sumit Enterprises
SM CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .