Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹2.9 CrAccepted-AOC | ₹2.9 Cr | 1st | Accepted-AOC 1st |
| 2 | 2nd₹3.5 Cr+₹60.3 L (20.8%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹3.5 Cr+₹60.3 L (20.8%) | 2nd | Rejected-AOC 2nd |
| 3 | 3rd₹3.6 Cr+₹65.3 L (22.5%)Rejected-AOC | ₹3.6 Cr+₹65.3 L (22.5%) | 3rd | Rejected-AOC 3rd |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
14 Sept 2023, 3:00 pmClosed
SANJEEV KUMAR TYAGI
EE PHE Division No. 1 Hisar
FOR AUGMENTATION OF WATER SUPPLY SCHEME
2023_HRY_305028_1
202374A92D4F A19D 4465 B225 DD1A0F9D7362564PUH
Open Tender
Civil Works
Works
270 days
Gangwa
FOR AUGMENTATION OF WATER SUPPLY SCHEME
3 documents required · 3 mandatory
₹20,000
Yes
₹7.2 L
Yes
8 Jan 2024
25 Aug 2023
14 Sept 2023
25 Aug 2023
14 Sept 2023
25 Aug 2023
25 Aug 2023 - 14 Sept 2023
Amount
Provision for providing and fixing flow meter with electronic display on delivery pipe inside pump chamber complete in all respects.
HT. ALLUMINIUM CABLE: Supply erection testing of standard make XLPE 3 core HT / 11 KV grade ISI marked Stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, innersheath of PVC, galvanised steel flat strip armoured, and overall PVC sheathed cable conforming to is 7098 (part-2) 2011 with up to date amendments for making following connection a) from G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect. Make: Indian Cables Ltd./ Polycab / RR Cables / CAPP / Finolex / Havells / Gloster / Universal / Fort Gloster Industries Ltd./ Indian Cable Co. / Asian Cables Corporation Ltd 35 Sqmm size
CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set forClear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked 3000 LPM x 45.00 M x 50 BHP
PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Pumping set a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Panel Board for motors having capacity of 50 BHP
COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd 35mm2 3core
LT CABLE ALLUMINIUM: Supply, erection, testing and commissioning of IS marked 3.5 core Cables, Solid Aluminum conductor up to 10sqmm and balance stranded conductor, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Aluminium wire for single core up to 70sqmm and balance Aluminium strip, Glavanised wire for cables up to2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip) extruded PVC type ST2 Outer sheathed, 650/1100V grade as per IS7098 (Part-1) 1988 with up to date amendments along with all accessories complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables / CAPP / Gloster / Universal / Fort Gloster Industries Ltd./ Asian Cables Corporation Ltd. 95 Sqmm size
H.T. METERING PANEL: Supply, erection, testing and commissioning of 11KV Indoor H.T Metering Panel complete with suitable CTs, PTs and 3 phase, 4 wire Digital Electronic KWH Meter with accuracy class of 0.5 as per requirement and approval of DHBVN, consisting of the Cubical Panel Box of minimum size 700mm x700mm x1500mm free standing, floor mounting type made out of 14 SWG CRCA sheet steel powder coated with epoxy coated channel iron base frame
Operation and Maintenance of water works for complete scope of work mentioned in the DNIT and of whole existing water supply scheme in the village Disinfection material supplied by the PHED as per schedule-IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the A/mtc estimate). complete in all respects as per approved NIT. 1) Operation and maintenance during defect liability period after 3 month trial run period ( operation only)
1st year Operation and maintenance
2nd year Operation and maintenance
3rd year Operation and maintenance
4th year Operation and maintenance
5th year Operation and maintenance
Bidder Name
Amount
M/S SAT NARAIN GUPTA CONTRACTOR(GSTN-06ABDFS4734R2ZK)
VINAY KUMAR CONTRACTOR(GSTN-NA)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
ROHTASH KUMAR CONTRACTOR
M/S SAT NARAIN GUPTA CONTRACTOR
ROHTASH KUMAR CONTRACTOR
VINAY KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .