Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹8.6 L+₹1.3 L (17.7%)Rejected-Finance 01 18 19 ANANDVAN ROW HOUSE LAM ROAD NASHIK ROAD NASH IK ROAD SAUBHAGYA NAGAR NASHIK MAHARASHTRA 422101 | NASHIK | MAHARASHTRA | 422101 | L2 | Rejected-Finance SINCE NOT L1 | |
| 3 | L3₹9.0 L+₹1.7 L (23.6%)Rejected-Finance 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L3 | Rejected-Finance SINCE NOT L1 |
Tender Value
Refer Docs
EMD Value
₹19,400
Closing Date
12 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEOLALI
GE DEOLALI, 422401
SPL REPAIR TO BLDG NO T 112 OR LIVING ACCN OF EQPT BTY/TECH SP REGT,UNDER THE AOR OF GE DEVLALI
2020_MES_399220_2
8918/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEOLALI
class E cat a i
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹19,400
Yes
21 Jan 2021
29 Dec 2020
14 Jan 2021
29 Dec 2020
12 Jan 2021
29 Dec 2020
60 days
Amount
Dismantling of manglore pattern roofing tiles laid dry etc complete all as specified and directed.
Dismantling of timber battens for tiles of any size including tilting fillets spaced exc 15cm centres etc complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position framed work etc complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E- 250) quality-A
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M& L for Terrazzo tiles 25cm x 25 cm x 22mm thick, with size of chips upto 6 mm; set jointed and pointed in neat cement slurry in floors with grey cement and no pigment and cut and polished laid over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
M& L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement plaster on brick masonry walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished Sand-faced complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) in copings as in adjoining to roof sheet and wall and like etc and finishing of exposed surfaces smooth etc including formwork if any complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) including cover filets etc omplete all as specified and directed.
S&F for powder coated aluminium alloy interlocking snap grid 605mm x 605mm consists of main tee runners of size 38mm x 25mm x 1.5mm and cross tee of size 25mm x 25mm x 1.5mm, spaced between the main tee at 600mm centre to centre to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 2mm fixed to wall perimeters at 450mm centres and shall confirm to IS 733, IS 1285 with and including hangers of 3mm dia G.I. (upto 12mm length and 1200mm centres) adjusting level fixed to roof steel members by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long etc complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement decorative building boards of approved design laid/inserted to aluminium framework fixed in ceiling flat or sloping complete all as specified and directed.
Demolition of plain cement concrete (un reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed.
M & L for PCC 1:3:6, type C2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete.
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M & L for preparation of new plastered surfaces of walls and apply two coats of oil bound distemper over a coat of 3mm (2mm +1mm) wall care putty complete all specified and directed.
M & L for preparation of new plastered surfaces of walls and apply two coats of cement base paint over a coat of 3mm (2mm +1mm) wall care putty complete all specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of 3mm (2mm +1mm) wall care putty all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered wall surfaces and applying two coats of cement base paint over a coat of white wash all as specified and directed.
Taking down unserviceable carefully copper/aluminium point wiring (light, fan, socket or power) complete with teak wood battens including fittings such as switches, socket outlets, ceiling roses, pendent brackets, holders etc. but excluding fan regulators, tube light fittings and sketch fittings and making good disturbed surfaces of walls, floor etc complete all as specified and directed.
Material and labour for point wiring with stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and directed. for :-
(a) One Light point controlled by one switch
(b) One fan point controlled by one switch
(c) One 5 pin socket outlet. 5 Amps on the same board.
(d) One 5 pin socket outlet. 5 Amps on the independent board.
All as item No- 28 above but One 15 A socket outlet independent with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and directed.
Supply and fix switch socket combination 5 pin 5 Amps flush type (multi purpose ) complete all as specified and directed.
Supply and fix switch socket combination 2 in 1, 5/6 pin, 5 and 15 amp flush type universal complete all as specified and directed.
Supply and fix ceiling rose of size 65 X 25 mm surface Bakelite three terminals complete all as specified and directed.
S & F in replacement of lamp angle/batten holder Bakelite with and including 5w LED Bulb complete all as specified and directed.
Supply and fix fan regulator 100 watts electronic type for ceiling fan of size 900 mm to 1400 mm sweep working on 230 Volts AC supply with all necessary connections etc complete all as specified and directed.
S & F in replacement double door sheet metal enclosures factory made DBs 4 way,240 volts,protection class IP-43, SUITABLE FOR FIXING OF MCBs,Isolators etc,confirming as per IEC 61439-3,Suitable for flush Mounting and surface mounting, With Neutral bar,Earthbar and cable ties for cable management,fully shrouded Neutral bars,prefitted masking sheet complete all as specified and directed.Make:-Legrang,Cat No:5076 10 or equilavent in Siemens/Hanger
S & F in replacement double door sheet metal enclosures factory made DBs 8 way,240 volts,protection class IP-43, SUITABLE FOR FIXING OF MCBs,Isolators etc,confirming as per IEC 61439-3,Suitable for flush Mounting and surface mounting, With Neutral bar,Earthbar and cable ties for cable management,fully shrouded Neutral bars,prefitted masking sheet complete all as specified and directed.Make:-Legrand,Cat No:5076 11 or equilavent in Siemens/Hanger
S&F MCBs Single Pole of 240 volts 5-32 Amps,10KA Capacity, 'C' Series of Make:-Legrand,Cat No: 4085-87 to 90,92,93,94,95 or eqivalent in Siemens/Hnger
S&F MCBs Single pole + Neutral 240 Volts,32-63 Amps,10KA Capacity 'C' SERIES OF MAKE:Legrand,Cat No : 4086-17 to 20 or equivalent in siemens/Hanger
M & L in replacement of sub main wiring with 2 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade incl 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note :-(i) Two run of copper cable and one run of earth wire shall be measured as one length. (ii) including conduit/PVC casing/caping
S&F Decorative ultra slim linear LED lighting with extruded polycarbonate,environment friendly,energy efficient E-LITE LED PRIDE PLUS 18W LED 6000K Make:-Havells Cat Part num:- LHEXBLP7PN1W018 or equivalent in Bajaj / Philips / Wipro
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground all as specified and directed (earth pit not less than 2.25m below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanized iron all as shown in Electrical Plate No. 3 connected to earth test point all as specified or indicated and testing on completion including necessary excavation and earth work in any type of strata, PCC pit and RCC cover, GI protection pipe 15mm bore light grade , watering pipe, wire mesh etc. all as specified and directed .
S&F LED Bldg Security light Endura City liner uber having long life versalite pressure die-cast aluminium IP66 roadway luminaries with high power 20W LED as light source with acrylic cover Make:-Havells LHEWEBP7PL6S020 or equivalent in wipro,Philips,Bajaj
M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S. nuts, bolts 75 mm long 12 mm dia -4 Nos & flat washer (3mm thick) 01 No. for each including preparation of steel surfaces and painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and directed.
S&F XLPE insulated armoured heavy duty electric cables with aluminium conductor,1100 volts grade, cross sectional area 10 sqmm 2 core
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L sand , filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Note: Amount of sch of credit of Rs.23,775.00/-will be deducted from total amount of BOQ.
M/S MANISH CONSTRUCTION CO
M/S SAMEER SUBHASH PATANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .