Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.9 LAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | 2₹15.2 L+₹79,642.50 (5.53%)Rejected-Finance | 2 | Rejected-Finance Rejected due to not L1 | |
| 3 | 3₹15.9 L+₹1.5 L (10.7%)Rejected-Finance | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹18.4 L+₹4.0 L (27.8%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | 4 | Rejected-Finance Rejected being not L1 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
2 Oct 2024, 6:00 pmClosed
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
REPAIR AND MAINTENANCE OF STREET LIGHT FITTINGS LT POLES TIMER PANEL POLE BOX MCCBS AND CONNECTED ITEMS AT DK I AND II SHOOTING RANGE 8711 CERMONIAL BATTERY NICHOLSON RANGE LORRY ROAD AND NODEL PUMP HOUSE I AND ADJOINING AREA OF AGE U ELECT SU
2024_MES_671369_1
GE ELEC/D-49/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELEC SUPPLY
₹54,000
Yes
3 Dec 2024
4 Sept 2024
3 Oct 2024
4 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
Dismantling broken concrete/steel poles, any size complete all as specified and directed by Engr-in-charge.
Taking down of existing street light from item No 1 above and fixing on new poles complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level complete all as specified and directed by Engr-in-charge.
Returning filling in, including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engr-in-charge.
Supply & laying bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engr-in-charge.
All as per srl item No 7 here-in-before but using old bricks complete all as specified and directed by Engr-in-charge.
Material and labour for Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and directed by Engr-in-charge.
Material and labour for providing cement concrete 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) 50 mm Thick complete all as specified and as directed by Engr in charge.
Material and labour for disconnecting of damaged unserviceable underground cable and Supplying, laying, jointing testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engr-in-charge. of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
10 Sqmm 2 core
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes complete all as specified and directed by Engr-in-charge.
40 mm dia
ditto- but HDPE pipe suitable for 5 kgf/cm 2 working pressure with all fitting size of 40 mm dia
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by Engr-in-charge.. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armored heavy duty aluminum conductor 1100 Volts grade complete all as specified and directed by Engr-in-charge for the following sizes :-
16-25 Sqmm x 4 core
35-50 Sqmm, 3.5 core
Supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. NOTE:- 1.The unit rate in this item is deemed to be included the cost of ,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole . The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminum paint over a coat of red oxide complete all as specified and directed by Engr-in-charge. 2. Excavation, eath work and GI brackets will measured and paid separately under relevant item .
Supply & Fixing in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts, bolts and washers and painting on steel surfaces with two coats of aluminum paint complete all as specified and directed by Engr-in-charge.
Material and labour for Cutting / pruning of tree branches along security light pole around 2 mtr radius of security light and removing from site including arrangement of T&P (Axe, rope & ladder etc) complete all as specified and directed by Engr-in-charge.
Supplying and fixing in replacement MCB DP, 63 Amps,50 Hz,10 KA,240 Volts complete all as specified and directed by Engr-in-charge.
Supplying and fixing in replacement MCB SP , 6 to 32 Amps,50 Hz,10 KA,240 Volts complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement KIOSK box weather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red color on front face of KIOSK box body complete all as specified and directed by Engr-in-charge. Incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer.
Material and labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminum paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engr-in-charge.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supplying , drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
-diito- all as above but size of cable 3 core, 2.5 Sqmm
Supply & Fixing in repairs integral LED light fitting 45/60 watts comprising pressure die cast housing with power coated aluminum housing working as a heat shrink and toughened glass suitable for 32 mm OD pipe bracket IP-65 protection complete all as specified and directed by Engr-in-charge.
Supply and fixing Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminum IP66 LED flood light suitable for high lighting architectural façade and general purpose lighting of capacity 200/210 Watt LED complete all as specified and directed by Engr-in-charge.
Material and labour for disconnecting existing LED street lights/flood lights from PCC/GI poles for repairing of unserviceable LED street light fitting of any type / make of 45-60 watt capacity by replacing UNSV compact LED electronic driver, broken tempered glass, silicon gasket, led bulbs ,FMSPD suitable to operate on 150 to 277 Volt 50 / 60 Hz AC supply and reinstall at same location/place after repair work complete all as specified and directed by Engr-in-charge. Note:- Replacemnet of item no 28 to 31 are incorporated against item no 27 .
-ditto- all as above but Street Light of cap 72/75 watt
-ditto- all as above but Street Light of cap 120/125 watt
-ditto- all as above but Street Light of cap 190/200 watt
-ditto- all as above but flood lights 200 watt
Supply only compact LED electronic driver suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 40/60 watts complete all as specified and directed by Engr-in-charge.
-diito- all as above but cap of 72/75 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but cap of 190/200 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply only LED tempered glass suitable of cap 40/60 watts all as specified and directed by Engineer in charge.
-diito- all as above but cap of 72/75 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but cap of 190/200 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply only compact LED bulb set suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 40/60 watts complete all as specified and directed by Engr-in-charge.
-diito- all as above but cap of 72/75 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but cap of 190/200 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply only compact LED FMSPD suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 40/60 watts complete all as specified and directed by Engr-in-charge.
-diito- all as above but cap of 72/75 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but cap of 190/200 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply & fixing in replacemt of contactor 3 Pole power contractor, type MNX 110 having 2 NO +2 NC contacts complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacemt of contactor 3 Pole power contractor, type MNX 40 having 2 NO +2 NC contacts complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacemt of MCB 3 pole , 32 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacemt of Analog Time switch , 240 Volt AC , 50 Hz complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacemt of Digital Time switch , 240 Volt AC , 50 Hz complete all as specified and directed by Engr-in-charge.
Note for Sr item No. 25 to 36:- Contractor will make a identity (ie CANo. & firm name) using permanent paint marker pen on each component which will be replaced under repair of street light and he will be liable to change his new replaced item without any extra cost which become unserviceable due to any reason during execution period of CA and further up to defect liability period. It will be contractor responsibility to take the location of unserviceable street light fitting by MES rep at 9 AM at power house in every working day complete all as specified and directed by Engr-in-charge.
Material and labour for cleaning of existing LT panel by using blower machine and using CRC spray to remove all dust particle from LT panels ,and changing all burnt out LT thimbles of any sizes by removing of old one complete all as specified and directed by Engineer in Charge.
Material and labour for welding of existing LT panels doors by using Welding machine complete all as specified and directed by Engineer in Charge.
Material and labour for carrying out balance distribution of load on LT Lines by checking the existing load on the feeder (3 phase,4wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load. submit feeder wise report for before load balancing and after load balancing as per format given including maintenance of LT panel i.e. tinting of all nuts, bolts, washers, cleaning of LT panel dust etc complete all as specified and directed by Engr-in-Charge.
Material and labour for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to pole / main switch complete all as specified and directed by Engr-in-charge.
Material and labour for two coats of Aluminum paint of steel surfaces/fencing over a coat of red oxide primer including preparation of surfaces up to 20 sqm complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of Ammeter 0-400 Amp digital type per existing size complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement LT current transformer having ratio 630/5 Amp , 15 VA, Class 0.5. Complete all as specified and directed by Engr-in-Charge
All as per Srl item No.47 herein before but CT ratio 400/5 Amp
All as per Srl item No.47 herein before but CT ratio 315/5 Amp
All as per Srl item No.47 herein before but CT ratio 250/5 Amp
All as per Srl item No.47 herein before but CT ratio 200/5 Amp
Supply and fixing in replacement of cable gland for LT panel/feeder pilar up to 50 Sqmm cable complete all as specified and directed by Engr-in-charge.
All as per Srl item No.48 herein before but 70 sqmm cable to 185 Sqmm cable
All as per Srl item No.48 herein before but 240 sqmm cable to 400 Sqmm cable
Material and labour for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engr-in-charge.
Material and labour for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by Engr-in-charge.
All as per item No 50 above but of approx size upto 1.90 Sqm
Material and labour for disconnecting all electric LT Supply from timer panel of High mast and lowering down the high mast light fitting set by using motor/manually for repair/replacement work and change the unsv/worn out parts after repair works completed check the serviceability of high mast and remove all dust/nest and greasing the rope/motor/gear assembly for proper functioning before raising up in the the original position complete all as specified and directed by Engr-in-charge.
Supply only stainless steel rope 6mm dia complete all as specified and directed by Engr-in-charge.
Supply only D clamp including nut bolt and washers complete all as specified and directed by Engineer-in-charge
Supply only 6 Sqmm 5 Core flexible aluminum cable complete all as specified and directed by Engineer-in-charge
Supply only 1.5 HP motor 3 Ph 440 volt 50 hz AC supply for operating the stainless steel rope through gear assembly complete all as specified and directed by Engineer-in-charge.
Supply only gear assembly used for operating the stainless rope for lowering down the high mast fitting complete all as specified and directed by Engineer-in-charge.
Supply & fixing Timer switches astro type in having longitude and latitude of indian cities in memory 415 V, 3 phase 20 Amp rating with 415 V, 3 pole contactor fittedinside factory made 2mm thick steel enclosure duly powder coated paint complete all as specified and directed by Engineer-in-charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
Rajindera Enterprises (BID ID -3109928)
ALLIED CONSTRUCTION (BID ID -3113569)
Ridhi engineers and builders (BID ID -3112495)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .